HYDRAULICS & PNEUMATICS

Slides:



Advertisements
Similar presentations
Introduction to Pneumatic Components Build a Working Pneumatic Circuit
Advertisements

Pneumatic Valves Lesson 4.
Module 3 Practical Tasks
For power, motion and control
For system diagrams and component identification
HYDRAULICS & PNEUMATICS
For system diagrams and component identification
Basic Pneumatic Circuitry
principle.components.structure.application.circuit.h118/1d
Fluid Power Symbols.
Unit Ten Directional Control Valves
Pneumatics Pneumatik By Clifford Mayhew St Helens College
Pneumatic Systems (Part 2)
Discrete Control Logic 1. Pneumatic circuits - Low forces - Discrete, fixed travel distances - Rotational or reciprocating motion Main components: compressor,
Simple Pressure Control Valves
Development of single actuator circuits
Exercise 1 Feeding Workpieces from a Gravity Feed Magazine New Components: 3/2-Way Valve Single Acting Cylinder Service Unit.
Pneumatics technology 4. lesson
Presented by Jon Pannell
For precision and control
Standard Grade Technological Studies Pneumatic components: Five port, two state valves.
Pneumatics technology 5. lesson
HYDRAULICS & PNEUMATICS
Pneumatics.
Direct and Indirect Control
Actuators.
Valves Non-return valves Flow control valves Pressure control valves
Pneumatic Logic Sensors and Actuators
HYDRAULICS & PNEUMATICS
HYDRAULICS & PNEUMATICS
Logic Operations in Electro-Pneumatics
Electro-Pneumatics Module 1
Basic Principles of Hydraulics
Hydraulic Symbols. Piping and Tubing Symbols Normal working line Flexible working line Pilot line Drain line Enclosure outline Direction of flow.
Pneumatics.
Standard Grade Technological Studies
Pneumatic and hydraulic actuation system (cont.)
Fluid Power Control.
Actuators and Control, Part 3 Grant Agreement No LLP UK-LEONARDO-LMP Project acronym: CLEM Project title: Cloud services for E-Learning.
MECH1300 Pneumatic Components Topics Pneumatic Cylinders Pneumatic Motors Other Pneumatic Actuators Pneumatic Directional Control Valves Pneumatic Flow.
Air Cylinders Convert the energy contained in the compressed air
TSM363 Fluid Power Systems Valves Tony Grift
Fluid Power Control.
Basic Pneumatic Circuitry For control and automation.
Unit Twelve Pilot Operated Pressure Control Valves At first glance the diagram would appear to show three different valves but the box surrounding the.
Discrete Control Logic
Double Acting Cylinder
For system diagrams and component identification
PNEUMATIC CIRCUITS.
HYDRAULIC & PNEUMATIC CIRCUITS
HYDRAULICS & PNEUMATICS
HYDRAULICS & PNEUMATICS
Directional control valves
CNC CONTROL SYSTEM AND PART PROGRAMMING
Cylinder Cushioning mechanism
Pneumatics Module 9 Time delay valve.
Logic Functions Pneumatics Module 7.
Basic principles of hydraulic symbols
Actuators and directional control valves
Actuators & Directional Control Valves
Pneumatics Pneumatik By Clifford Mayhew St Helens College.
Industrial Electronics
IENG 475: Computer-Controlled Manufacturing Systems
Device Photographs.
Industrial Automation
The CASCADE Method similar to that for electromechanical devices.
Module – 4: Single Acting Cylinder
Actuators & Directional Control Valves
Introduction to Electro-pneumatic
Fluid Power System Electrical Control
Presentation transcript:

HYDRAULICS & PNEUMATICS Basic Pneumatic Circuits (2) Presented by: Dr. Abootorabi

Three position valves

5/3 Valve 5/3 valves have a third mid position. The valve can be tri-stable e.g. a detented lever operator or mono-stable e.g. a double air or double solenoid with spring centre. There are three common configurations for the mid position: All ports blocked Centre open exhaust Centre open pressure The majority of applications are actuator positioning and safety. 2 4 1 5 3 14 12 14 12 2 4 1 5 3 14 12 2 4 1 5 3

5/3 Valve actuator control The valve illustrated has “all ports blocked” in the mid position. Whenever the mid position is selected the pressure conditions in the cylinder will be frozen. This can be used to stop the piston at part stroke in some positioning applications. 2 4 1 5 3 14 12

5/3 Valve actuator control 4 2 4 2 4 2 14 12 14 12 14 12 5 1 3 5 1 3 5 1 3

5/3 Valve actuator control This version of a 5/3 valve is “centre open exhaust”. The supply at port 1 is isolated and the cylinder has power exhausted when this centre position is selected. The version illustrated shows a mono-stable version double pilot operated spring centre. The cylinder will be pre-exhausted when changing from the mid position. 14 4 2 12 5 1 3

5/3 Valve actuator control This version of a 5/3 valve is “centre open pressure”. The supply at port 1 is connected to both sides of the cylinder and the exhaust ports isolated when this centre position is selected. Can be used to balance pressures in positioning applications. The version illustrated is mono-stable, double solenoid, spring centre. 14 4 2 12 5 1 3

Logic functions for poppet and spool valves

Logic AND To obtain the output Z both plungers X AND Y must be operated and held. If X only is operated the air will be blocked at port 1 in valve Y. If Y only is operated there will be no pressure available at port 1. If either X or Y is released the output signal Z will be lost. Z 2 12 10 Y 3 1 2 12 10 X 3 1

Logic AND Z Z Z 2 2 2 12 10 12 10 12 10 Y Y Y 3 1 3 1 3 1 2 2 2 12 10 12 10 12 10 X X X 3 1 3 1 3 1

Logic AND This method must not be used as a two handed safety control. It is too easy to abuse e.g. one of the buttons could be permanently fixed down and the system operated from the other button only. Use the purpose designed two handed safety control unit. Z 2 12 10 Y 3 1 2 12 10 X 3 1

Logic OR Use of an ‘OR’ function shuttle valve: Source X and Y can be remote from each other and remote from the destination of Z. When X or Y is operated the shuttle valve seal moves across to prevent the signal Z from being lost through the exhaust of the other valve. Z 1 2 3 12 10 Y 1 2 3 12 10 X

Logic OR Z Z 2 2 12 10 12 10 Y Y 3 1 3 1 2 2 12 10 12 10 X X 3 1 3 1

Logic NOT A logic NOT applies to the state of the output when the operating signal is present (the output is simply an inversion of the operating signal). The valve shown is a normally open type (inlet port numbered 1). When the signal X is present there is NOT output Z. When X is removed output Z is given. Z 2 12 10 X 1 3 Z 2 10 12 X 1 3

Logic MEMORY A logic MEMORY allows the output signal state (ON or OFF) to be maintained after the input signal has been removed. Any bi-stable valve is a logic MEMORY. With this lever detented valve, once the lever has been moved X direction or Y direction it can be released and will stay in that position. Z X 12 10 3 1 Y

Logic MEMORY A bi-stable double pilot valve can be set or reset simply by a pulse (push and release) on buttons X or Y. Z 12 10 3 1 2 12 10 Y 3 1 2 12 10 X 3 1

Logic MEMORY II I Z Z Y Y X X 12 10 12 10 3 1 3 1 2 12 2 10 12 10 3 1

Logic MEMORY I II Z Z Y Y X X 12 10 12 10 3 1 3 1 2 2 12 10 12 10 3 1

Logic MEMORY (latch) A popular memory circuit is the latch. Will not re-make after pneumatic power failure. A pulse on X operates the pilot / spring valve to give output Z. A feedback from Z runs through the normally open valve Y to latch the operation of Z when X is released. A pulse on Y breaks the latch and Z is exhausted. Z 1 3 Y 12 10 2 12 10 3 1 2 12 10 X 3 1

Logic MEMORY (latch) Z Z Y Y X X 1 3 1 3 12 10 12 10 2 2 12 10 12 10 3

Logic MEMORY (latch) Z Z Y Y X X 1 3 1 3 12 10 12 10 2 2 12 10 12 10 3

Logic arrangements for fully balanced spool valves

Logic circuits (spool valves) NO / NC 5/2 OR Selection / Diversion Single pulse control Latch Air conservation OR, AND, NOT Double flow Single pulse maker Slow pressure build Pre-select

3/2 NO / NC A fully balanced valve allows pressure on any pot or combination of ports. A single valve can be used normally open or normally closed. 2 12 10 3 1 2 1 3 12 10

3/2 Valve selection / diversion Selection of one of two supplies connected to ports 1 and 3 can be different pressures. 12 10 3 1 2 12 10 3 1 Diversion of one supply to one of two outlets. If it is required to exhaust the downstream air a 5/2 valve is required. 3 1 12 10 2 3 1 12 10 2

OR, AND, NOT z OR 2 12 10 A single 3/2 pilot operated spring return valve can be use for any of these logic functions: x OR y gives output z x AND y gives output z. x gives NOT z 3 1 x y z AND 2 12 10 3 1 x y z NOT 2 12 10 3 1 x

Single pulse maker Converts a prolonged signal x into a single pulse z. Signal x must be removed to allow the valve to reset then x can be applied again. The duration of the pulse can be adjusted with the flow regulator. 1 2 3 12 10 x z

Slow initial pressure build up Choose a 3/2 pilot spring valve with a relatively high operating force e.g. 3 to 4 bar. When the quick connect coupling is made, the output at port 2 is controlled at the rate of the flow regulator setting. When the pressure is high enough to operate the valve full flow will take over. 2 12 10 3 1

5/2 OR function The valve at position ‘a’ is reversed connected and supplied from the valve conventionally connected at position ‘b’. The cylinder can be controlled from either position ‘a’ ‘OR’ position ‘b’. 4 2 12 a 14 5 1 3 4 2 12 b 14 5 1 3

Double flow Where a larger 3/2 valve is not available. 4 2 1 3 12 14 5 Where a larger 3/2 valve is not available. Two flow paths in a 5/2 valve each with a separate supply can be arranged to give double flow or supply separate devices. Ensure the tube size to the cylinder is large enough to take the double flow. 4 2 1 3 12 14 5

Feedback methods

Time delay A signal is restricted to slow the rate of pressure build up on a pressure switch (3/2 differential pressure operated valve). When the pressure switch operates a strong un-restricted output is given. A reservoir provides capacitance to allow less fine and sensitive settings on the flow regulator making it easy to adjust. Output 2 12 10 3 1 Signal in

Time delay Manual remote start of a double acting cylinder with a time delay in the outstroked position before automatic return: 2 1 4 5 3 14 12 10 + - A a1

Time delay Problem:

Time delay Solution:

The end. سعدی (علیه الرحمه):