Fordham Place Bronx, NY Aric Heffelfinger Structural Option Spring 2006.

Slides:



Advertisements
Similar presentations
8621 Georgia Avenue Silver Spring, MD
Advertisements

Outline CH1.Introduction CH2.Preliminary Design CH3.3D Model.
ASHA National Office Building 2011 AE Senior Thesis Ryan Dalrymple 5 th year Structural Option BAE/MAE Advisor: Dr. Thomas Boothby Photo Courtesy of Boggs.
Reinforced Concrete Design-8
Lecture 9 - Flexure June 20, 2003 CVEN 444.
Lecture 33 - Design of Two-Way Floor Slab System
Abstract This project is a structural analysis and design of a residential building located in JENIEN City, The building is consisted of 7 floors. The.
Jeremiah Ergas AE 482 – 5 th Year Senior Thesis Structural Option April 15 th, 2008 Faculty Consultant: Dr. Ali Memari Northside Piers – Brooklyn, NY Structural.
A Medical Office Building For The Primary Health Network Daniel Goff I Structural Option Dr. Thomas Boothby l Faculty Advisor Sharon, Pennsylvania Source:
Penn State Hershey Medical Center Children’s Hospital Hershey, Pennsylvania Matthew Vandersall Structural Option AE Senior Thesis Dr. Richard Behr.
The University Sciences Building Northeast, USA Final Presentation Chris Dunlay Structural Option Dr. Boothby.
University Health Building Thesis Final Presentation
Footings.
Composite Beams and Columns
Crocker West Building State College, Pa Eric M. FosterStructural OptionSpring 2009.
Courtesy of Holbert Apple Associates Georgia Avenue Building Introduction Statistics Gravity System Lateral System Problem Statement & Solution.
Samuel M. P. Jannotti Structural April 14, 2008 American Eagle Outfitters Quantum III: South Side Works.
LOCKWOOD PLACE BALTIMORE, MARYLAND Monica Steckroth- Structural Option.
Reading Structural Drawings
Rockville Metro Plaza II Rockville Pike John Vais | Structural Option PSU AE Senior Thesis 2014 Faculty Advisor – Dr. Hanagan Rockville, Maryland
Hershey Research Park Building One Jonathan Krepps Structural Option Senior Thesis 2013 Faculty Advisor: Dr. Hanagan.
Nick Szakelyhidi Structural Option Office Building Washington, DC Nick Szakelyhidi Structural Option.
GARY NEWMAN STRUCTURES OPTION ADVISOR: DR. HANAGAN SENIOR THESIS PRESENTATION SPRING 2008.
AMERICAN EAGLE OUTFITTERS Quantum II Corporate Headquarters Michael Sandretto Spring – 2007 Structural Option.
Southeast View of IRMC West View of IRMC. Presentation Outline Introduction Existing Structure Thesis Goals Structural Depth Lighting Breadth Conclusion.
BRYAN DARRIN SENIOR THESIS PRESENTATION MILLENNIUM HALL DREXEL CAMPUS PHILADELPHIA, PA.
Structural System Redesign Existing Conditions Proposal Gravity Design Lateral Design Cost Comparison Schedule Impact Conclusions.
Final Thesis Presentation Washingtonian Center Lee ResslerApril 15, 2008 Faculty Advisor: Dr. Memari.
Duquesne University Forbes Expansion
The Odyssey Condominium Aaron Snyder Arlington, Virginia
SEAN BEVILLE STRUCTURAL OPTION ADVISOR: PROF. BOOTHBY APRIL 13, 2009 TEMECULA MEDICAL CENTER “STRUCTURAL SYSTEM OPTIMIZATION” THE DEPARTMENT OF ARCHITECTURAL.
300 North La Salle Liam McNamara BAE / MAE Senior Thesis April 13 th, 2010.
The Towers at the City College of New York Robin Scaramastro - Structural Option - Advisor: Dr. Memari Senior Thesis Final Presentation – Spring 2007.
URS – ARENA DISTRICT OFFICE BUILDING DAVID LEE STRUCTURAL OPTION.
Third Avenue NY, New York Michelle L. Mentzer Structural Option.
Dan Donecker BAE/MAE – Structural Option Senior Thesis Project 35 West 21 st Street New York, New York.
Howard County General Hospital Patient Tower Addition Columbia, MD Kelly M. Dooley Penn State Architectural Engineering Structural Option.
Welcome to Daniel Painter’s Architectural Engineering Senior Thesis Presentation of Two Freedom Square April 16, 2003 Pennsylvania State University.
Jonathan Goodroad Structural Option 2005 Thesis Penn State AE Delaware State University Administration and Student Services Building.
Brad Oliver – Structural Option Advisor – Professor Memari.
Oklahoma University Children’s Medical Office Building Oklahoma City, Oklahoma AE Senior Thesis Final Report April 14, 2014 Jonathan Ebersole Structural.
Justin Purcell Structural Option Advisor: Dr. Hanagan.
Computer Associates International, Regional Office
Park Potomac Office Building “E” Kyle Wagner l Structural Option AE Senior Thesis l Spring 2010 Faculty Consultant l Prof. Kevin Parfitt.
Eastern USA University Academic Center Alexander AltemoseIStructural Option.
SteelStacks Performing Arts Center Sarah Bednarcik | Structural BAE/MAE Faculty Advisors: Dr. Linda Hanagan & Dr. Ali Memari Spring Thesis 2013Bethlehem,
James C. Renick School of Education PSU AE Senior Thesis 2006 Mick Leso - Structural North Carolina A&T State University - Greensboro.
Chagrin Highlands Building One Beechwood, Ohio Branden J. Ellenberger - Structural Option Senior Thesis 2004.
Michael A. Troxell Structural Option Senior Thesis 2006 The College of Business Administration Northern Arizona University Flagstaff, Arizona.
Practical Design of PT Buildings
Biobehavioral Health Building The Pennsylvania State University Daniel Bodde Structural Option Advisor – Heather Sustersic.
THE NORTHBROOK CORPORATE CENTER Redesign of the Lateral Load Resisting System.
John Pillar Hampton Inn & Suites National Harbor, Md Advisor: Dr. Memari Distinguished Speaker Series, Spring 2007.
William W. Wilkins Professional Building Columbus, Ohio Michelle Benoit Senior Thesis Presentation Spring 2007 Structural Option.
Hunter Woron Spring 2012 Structural Professor Parfitt.
Design of One Way Slabs CE A433 – RC Design T. Bart Quimby, P.E., Ph.D. Spring 2007.
CBD Chemical Production Building Virginia, USA Christina DiPaolo │ Structural Option.
R. Bryan Peiffer– Structural Option AE Senior Thesis 2011 Three PNC Plaza, Pittsburgh Pa.
Pearl Condominiums Philadelphia, PA
An-Najah National University Faculty of Engineering
786 Design of Two Way floor system for Flat Plate Slab
Outline: Introduction: a ) General description of project b) Materials
Advisor: Professor M. Kevin Parfitt
Agricultural Hall and Annex Easting Lansing, MI
Slender Columns and Two-way Slabs
Lecture 39 - Design of Two-Way Floor Slab System
Ryan Johnson - Structural Option
Outline CH1.Introduction CH2.Preliminary Design CH3.3D Model.
North Shore at Canton The Pennsylvania State University
Mitre III Building McLean VA Debra Schroeder Structural Option.
Presentation transcript:

Fordham Place Bronx, NY Aric Heffelfinger Structural Option Spring 2006

Presentation Outline  Building Introduction  Existing Structure  Proposal / Goals  Structural Redesign  Breadth Work  Conclusion / Recommendations

Building Introduction  Owner Acadia Realty  Construction Manager Acadia Realty  Architect Greenburg Farrow  Structural Engineer M.G. McLaren  Mechanical Engineer Greenburg Farrow

Building Introduction  Size  15 Stories  174,000 SF  Cost  $34.8 Million  Retail Ground – 2 nd floor  Community 3 rd – 9 th floor  Office 10 th – 15 th floor

Presentation Outline  Building Introduction  Existing Structure  Proposal / Goals  Structural Redesign  Breadth Work  Conclusion / Recommendations

Existing Structure  Design Codes Building Code of New York City  Floor System  Composite Concrete Slab & Steel beams  6 ¼” Lightweight Slab (115 pcf)  A992 Grade 50 Steel  3” Composite Galvanized Metal Deck

Existing Structure  Columns  Grade 50 W14 Shapes  Splice every 3 rd Floor  13.5 ft typical unbraced length  Lateral System  Eccentrically braced Chevron Frames  12 x 12 x ½ HSS bracing members  A500 Grade B Steel  Fy = 46ksi  Fu = 58ksi

Existing Structure  Foundations  150 ton Group piles (4-13)  45 – 50 ft Deep  A992 Grade 50 Steel W shapes  Enclosure  Brick Façade up to 6 th floor  Glass Façade 6 th – 15 th floors

Presentation Outline  Building Introduction  Existing Structure  Proposal / Goals  Structural Redesign  Breadth Work  Conclusion / Recommendations

Proposal / Goals  Viable Structural Systems  Effects the new floor system had on other building systems  Lateral System  Columns  Foundations  Compare Constructability & Cost  Examine pros / cons of each systems  Determine which floor system is more efficient in NY area

Presentation Outline  Building Introduction  Existing Structure  Proposal / Goals  Structural Redesign  Breadth Work  Conclusion / Recommendations

Structural Redesign  Design Codes  ASCE 7 – 02  ACI 318 – 02  Floor System  Two Way Slab with Drop Panels  Normal Weight Concrete  f’c = 4ksi  Designed using ADOSS

Structural Redesign  Design Process  Column size estimate  ACI to get minimum floor slab thickness, drop depth, and width  Determine column strips  Input into ADOSS  Make Adjustments as necessary  Determine reduced gravity loads and moments on columns  Input Into PCA Column

Structural Redesign  Design Process  Check column size assumption  Select slab and column Reinforcement  Determine critical lateral load  Design shear walls  Select shear wall Reinforcement  Consider special areas throughout building

Structural Redesign  Column size estimate  24” x 24”  Clear span = 28’ – 2’ = 26’  Floor slab depth  ℓn/36 = 26/36 = 8.67”  use 9”  Drop panel  Projection = ¼ t slab = 2.25”  try 3.5”  Width = 1 / 6 span = 1 / 6 (28’) = 4’-8”

Structural Redesign  Column strip width  Width = least of 0.25 ℓ 1 or ℓ 2

Structural Redesign  Input into ADOSS  NW concrete (150 pcf)  f’c = 4ksi  Reinforcing steel fy = 60ksi  Minimum rebar spacing = 6in  Minimum rebar size = #4  Loads  Dead = 30psf  Live = 80psf  Geometric properties as determined in previous slides

Structural Redesign  Adjustments  Drop projection  Increase to 5.5”  High shear stresses at columns  Excessive reinforcement at columns  Reduced Live loads  L = L o [ (15/√(K LL A T )]  L o = 80psf  A T = Tributary Area  K LL = Live load element factor

Structural Redesign  Input into PCA Column  f’c = 4ksi  Biaxial Column  steel reinforcement fy = 60ksi  24” x 24” with increment of 2”  Equal reinforcement  Cover = 0.75” to ties  Min / Max bar size = 8 / 11  Column Heights = varies  Moments from ADOSS  Reduced axial loads

Structural Redesign  Check Column Size Assumption  Actual Size = 26” x 26”  Conservative compared to 24” x 24”  Selection of Slab Reinforcement  Column Strip  Positive Reinforcement  As ≅ 0.3 in 2 /ft ̣ ˙ ̣ ρ =  12”  Negative Reinforcement  As ≅ 0.55 in 2 /ft ̣ ˙ ̣ ρ =  50% long, 50% short  12”

Structural Redesign  Selection of Slab Reinforcement  Middle Strip  Positive Reinforcement  As ≅ 0.2 in 2 /ft ̣ ˙ ̣ ρ = ρ min =  50% long, 50% short  12”  Negative Reinforcement  As ≅ 0.3 in 2 /ft ̣ ˙ ̣ ρ =  12”

Structural Redesign  Selection of Column Reinforcement  Longitudinal  Maximum = 20 - #11  As = 29.7 in 2 ̣ ˙ ̣ ρ =  Minimum = 12 - #8  As = 9.48 in 2 ̣ ˙ ̣ ρ = > ρ min = 0.01  Transverse  Spacing = least of the following:  16 x d longitudinal bar = 16(1”) = 16”  48 x d tie bar = 48(.375”) = 18”  0.5 x column dimension = 0.5(26) = 13”  use 12”  12” with #8 longitudinal bars  12” with #11 longitudinal bars

Structural Redesign  Determine Critical Lateral Loads  Seismic now controlled over wind  1.2D + 1.0E + L + 0.2S  Design Shear Walls  Treated as a huge cantilevered beam  12” thick based on drift limits  Shear Design  Reinforcement  12” for first third of building height  24” for second third  No reinforcement required for last third

Structural Redesign  Design Shear Walls  Flexural Design  Reinforcement  A s = 53.7in 2  Flanged shear walls  1ft flanges on each end to help fit steel  36 - #11’s  A s = 56.2in 2

Structural Redesign  Design Shear walls  Drift Limit  Most severely loaded shear wall  ∆ Limit = h/400 = 6.07in  ∆ Actual = Pb 2 ((3L – b) / (6EI) = 5.32in  Where P = Force on wall  b = Distance from base to force  L = Height of wall  E = Modulus of elasticity of concrete  I = Moment of Inertia of cross section  Used method of superposition

Structural Redesign  Special Cases  Floor Opening  Atrium space below  Mezzanine floor below  Large unbraced length  26” x 12” beams to support columns  minimum reinforcement in beams  f’c = 8ksi  20 - #11’s

Structural Redesign  Special Cases  Slab  Large clear span = 30’-0”  ℓ n /36 = 30/36 = 10” > 9”  Only two locations per floor  Continuous drops  Middle strip positive reinforcement depth  Designed normally but with 14.5” slab

Structural Redesign

Presentation Outline  Building Introduction  Existing Structure  Proposal / Goals  Structural Redesign  Breadth Work  Conclusion / Recommendations

CM Breadth  Cost of Superstructure  Composite steel  $1.74 Million  All Concrete  $2.42 Million  140% Composite steel  Difference  $2.42 – $1.74 = $680,000

CM Breadth  Durations  Composite steel  40.2 calendar weeks  All Concrete  78.3 calendar weeks  Primarily formwork  195% Composite steel  Difference  78.3 – 40.2 = 38.1 weeks

Presentation Outline  Building Introduction  Existing Structure  Proposal Goals  Structural Redesign  Breadth Work  Conclusion / Recommendations

Conclusions / Recommendations  Comparison of each system  Composite Steel is a better floor system

Acknowledgements  Special Thanks To:  Penn State AE Faculty  M.G. McLaren  Acadia Realty  AE Class of 2006  Family

QUESTIONS? ?

Structural Redesign  Edge Beam  26” x 12”  Tu = 133 k-ft  Torsion Threshold  Tu = 4.93 k-ft  Reduced Torsion  Tu = 4 x 4.93 = 19.7 k-ft  ФTn ≥ Tu  Tn = 2(A o )(A t )(f yv )cos(θ)/s  Use #4 bars, A t = 0.2  s = 12.3in

Structural Redesign  Edge Beam  Extra Longitudinal Reinforcement  Al = (At)(pn)(fvy)cot 2 (θ)/(s)(fyl) = 1.01in 2  Use 4 - #5’s