Similar presentations
Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
Advertisements

Philip Anderson National Sales Manager System Sensor Canada.
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
© ABB Group September 1, 2014 | Slide Turbidity Systems Accurate, reliable turbidity measurement.
Modelling and Simulation 7. September 2014 / Dr. –Ing Naveed Ramzan 1 Instrumentation and control Department of Chemical Engineering, U.E.T. Lahore Pakistan.
TM No.1, 6 th Street, Dr. Subbarayan Nagar, Kodambakkam, Chennai India. Ph. No. : +91 – 044 – Fax No.: +91 – 044 –
SS/L-TRXXXX 20 April Capacitance Manometer Transducer Bryn Asher October 19, 2009.
Spark Detection and Extinguishing System. Spark Detection – markets Initiative from Finnish insurance companies  Need for technically competitive and.
Prepared by Farid Khalaf.  Protect the worker.  Protect the sample being analyzed.  Protect the environment.
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
SAE AS9100 Quality Systems - Aerospace Model for Quality Assurance
Remote sensing in meteorology
AN INTRODUCTION TO THE CIRRUS PRO RANGE OF FIRE DETECTION DETECTORS
Gas Sensor and Transmitter
1 INTRUSION ALARM TECHNOLOGY DETECTION DEVICES. 2 INTRUSION ALARM TECHNOLOGY Detection devices can be either passive or active. Passive devices typically.
Carbon Monoxide and Carbon Dioxide Detector Lab Methods Day June 25, 2013 Taylor Myers.
Ultima® X Series Gas Monitors
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Iris Range : «Unconventional» conventional detectors.
RPC «REGMIK» 15582, Ukraine, Chernihiv region, Rivnopillya, Gagarin Street, 2B phone.: +38 (0462) , , , , +38 (050)
1. Footer Date CPP OWS and Filters Chicago Pneumatic People. Passion. Performance.
Computer Process Control Application. Computer process control In computer process control, a digital computer is used to direct the operations of a manufacturing.
SCADA and Telemetry Presented By:.
Introduction to Thermo Electron Instruments Robert Kinsella Sky Patton Thermo Electron.
Tel: +44 (0) Turbidity Application and Product Data.
Fire Detection Presentation
1 © Red Lion Controls Inc. Introducing the RAM 9000.
ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION. I. -
Enea Detectors Range.
ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION. I. -
High Sensitivity Smoke Detection
MAGNETO OPTICAL CURRENT TRANSFORMER Presented By: Shivankit Bansal Final Year Electrical Deptt.
Continuous Particulate Monitoring Using Light Scatter Photometers.
Laser- based smoke detectors
GCS 300 System Operation Application – Level 1.
Buildings and Structures 2 Fire Detection Systems.
MICE Hydrogen Control System MICE Collaboration Meeting CM33 27 th July 2012 PJ Warburton – STFC Daresbury Lab.
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheWorkshop European Standards Requirements of.
Basic Awareness Training for all Staff
Gas Coordination Panel 24/08/2004 Flammable Gas Installation Requirements, Interlocks, etc. F.H.
1 an eye that never blinks. 2 Refrigerant Monitoring  Checking for excess moisture in the refrigerant  Checking for low charge or loss of refrigerant.
Industrial Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
1 Daya Bay RPC Gas Safety System - Gas Cabinet Test Report Changguo Lu, Kirk McDonald Princeton University (October 11, 2009)
The D50 Is a state of the art environmental monitor using only the best quality components available. It offers multiple sensors in a single unit with.
E VERY L IFE H AS A P URPOSE… Ultima ® XI Gas Monitor.
“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise.
I & C.
HP SURVEY INSTRUMENT CALIBRATION AND SELECTION PRINCIPLES OF RADIATION DETECTION AND QUANTIFICATION January 13 – 15, 2016 TECHNICAL MANAGEMENT SERVICES.
Air Cleaning Technology Laboratory at UIC  ASHRAE 52.2 Compliant Test Loop for Particulate Air Cleaning Devices Testing specifications Testing specifications.
Balances The balance is an instrument which measures the mass of a body or substance using the gravity force which acts on that body At present, there.
Hygrometry Part 2.
What can the Aerospace Industry Contribute to Very Early Fire Detection? Presented by: Stephen Lederer Marketing Manager, Honeywell, Inc.
50% LBNE Concept Design WCD Infrastructure. Mechanical.
Farms, sensors and satellites. Using fertilisers Farming practice are changing Growing quality crops in good yields depends on many factors, including.
 Market Survey  Design, supply, delivery and installation of a Clean Room Facility  at the entrance of the LAr detector tank,  used for the storage.
Standards Certification Education & Training Publishing Conferences & Exhibits ISA SP12 Standards Related to Equipment in Hazardous Locations.
Introduction of Laser Evaluating Technology to Street Leak Surveys Ashraf Salha APA Group Gas Speak Colloquium September 2015.
Fire Detection Equipment and Systems in Dubai
MULTI-FILTER INSTRUMENT (IRPC)
Gas Detection in Water Treatment
National Laboratory Association
Energy Audit Instruments
Company MIAB - Mölnbacka Industri AB of Deje, Sweden was established in MIAB provides equipment protecting the environment by removing solvent vapours.
The FG series of explosive and toxic gas detectors and panels
Developing Standards and Linkage to IECEx
Turbidity - “A Quantum Leap in Technology” Southwest Section AWWA
Remote sensing in meteorology
PLC Front Panel.
Presentation transcript:

The Theory of Near Light Scatter Scattered light has components due to diffraction, refraction and reflection For low detection angles, scattered light is dominated by the diffraction and refracted components The particulate reflective properties and colour have minimal effect on instruments response Diffracted and refracted intensities are small

Microdust Photometer layout

Clean air condition Infrared beam is focused onto the light stop No forward scattering effect Zero signal intensity seen by detector

Particulate introduced to sample volume Beam is scattered due to the effects of diffraction, refraction and reflection Intensity of Infra red signal is measured by detector

Concept

ADR 1500

PDR 1100

ADR 1500

Principle of Operation What airborne pollutants can be measured Data Ram responds to all particulate matter that is airborne. It is however optically configured to produce optimal response to particles in the range 0.1 – 10.0 µm, achieving a correlation to gravimetric measurements. Output Data Ram produces an analog 4-20 mA powered loop and a 0-5 V output signal. It also has a selectable Alarm digital output. Software Data Ram is supported by pDR-COM custom software, however this is aimed at short-term personal monitoring and is not suitable for continuous long term fixed-point operation. The PDR-1100 output signal is normally fed into the “Backbone” system of the mine, all reporting and data logging is configured by the end user.

Applicability (surface, underground, plants) PDR1100 was developed specifically for underground use where dust loading is typically high and consequential contamination of sensing devices and other components are a reality. PDR1100 does therefore not employ a pump. Air is induced at low velocity which entrains the smaller particles and reduces contamination.

Ex certification SANS 60079-: “Electrical apparatus for explosive gas atmospheres”; Part-0: 2009 “General Requirements”; and Part-11: 2007 “Equipment protected by intrinsic safety ‘I” Approved explosion protection rating: Ex ib I Inspection Authority Certificate: MASC M/10-259X  

Installation PDR1100 is supplied with two steel suspension Eye Bolts. A directional arrow indicates the mounting position in relation to the mine airflow. The electrical installation is a simple 3-wire connection. When power is applied, the instrument switches on and starts transmitting automatically.

“Backbone Requirements” Power supply: 12-24 V DC (“IS” for Fiery Mines) Output: 4-20 mA or 0-5 V

ADR 1500 SOLAR PANEL

Maintenance requirements Annual Calibration – This is carried out at our Roodepoort facility. The process includes cleaning and inspection of the Sensor Lenses and other internals. The zero process is done on a certified Clean Air Bench which uses Hepa Filters. The Span calibration is carried out in a Ventilated Dust Chamber using Arizona Road Dust - ISO SAE Fine. Field Calibration – This is essentially a zeroing function which resets the zero point above the background level of accumulated dust in the measuring chamber. The PDR1100 is equipped with ports which aspirated to remove accumulated dust from the Measuring Chamber.

Supplier support network Locally manufactured or imported Data Ram is manufactured by Thermo Fisher Scientific in Franklin, Massachusetts USA. The outer housing and ancillaries are manufactured locally. Our HQ AMS Haden Instrument Service are based in Allen’s Nek, Roodepoort. All sales and technical support is provided from this centre.

OEM Training and support AMS Haden provide on-site user training on all aspects of PDR deployment. The company also provides a comprehensive repair and calibration service from our Roodepoort facility.

PDM 3700

The End