Location of installation *Install the detector so that the majority of target activity is across the detection pattern. *The mounting height should be.

Slides:



Advertisements
Similar presentations
HWg-Juno HW group is a manufacturer of IP-based sensors from Prague, Czech republic. HWg delivers remote monitoring & control solutions.
Advertisements

Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
AXIS New Innovations October AXIS Product Naming Structure.
Wireless Ready Products Battety operated High-Tech OPTEX detection.
HX-40/40AM 3.0m high mount outdoor detector HX-40: standard model HX-40AM: HX-40 with active IR anti-masking model confidential.
1 CCTV SYSTEMS CAMERA MOUNTS AND ENCLOSURES CAMERA MOUNTS AND ENCLOSURES.
PICNIC Demo Module 2 IP-based utility outlets 陳育瑋、方煒 台大生機系.
Remote Monitoring and Management Solutions ®
Checker 200 Series Training Presentation. CONFIDENTIAL The Checker 200 Series Versatile, multicolor lighting provides high contrast Small: 67x36x70 mm.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Presents The Next Generation Outdoor Perimeter Electrostatic Field Sensor.
5-15. UTP Cables/Connectors/Devices for use on New Technology Analog and IP Systems.
Surveillance camera in terms of business. Index *surveillance systems * Types of control systems * Elements of control systems * Types of monitoring camera.
DUE Security and Fire Alarm Systems LEARNING OUTCOME 7B Describe design overview and location considerations.
POE-E101 Copyright © PLANET Technology Corporation. All rights reserved. IEEE 802.3af Power over Ethernet Extender.
IEEE 802.3at Power over Gigabit Ethernet Extender
1 INTRUSION ALARM TECHNOLOGY DETECTION DEVICES. 2 INTRUSION ALARM TECHNOLOGY Detection devices can be either passive or active. Passive devices typically.
Security Devices A modern security system, with its array of electronic components, is designed to sense, decide, and act. The security system senses events.
INTRUSION ALARM TECHNOLOGY
Date: Nov 17, 2011 Presenter’s Name : Ray Chuang Presenter’s Title : Product Manager MD8562/62D Product Announcement.
STT Condigi Smart-Caller ’CareCom’ Nurse- Call System Combines with
Introduction - IP8151 SUPREME Night Visibility Best choice for Day/Night Security.
Date: Nov. 8th, 2011 VIVOTEK Product & Marketing Team IP8133/33W Product Announcement Confidential.
Laser Scan detector RLS-3060 Basic information & installation of Laser Scan detector Basic information & installation of Laser Scan detector OPTEX CO.,
The special unit for special tasks.  Installation possibilities Private area Special object Industrial park.
Hybrid Wind & Solar Generation Project
Multiple Function Security System. INTRODUCTION & APPLICATION ● 4 functions in on system: – Light Detector – Contact Detector – Motion Detector – Pressure.
High Sensitivity Smoke Detection
Developments in the IntelliFIBER ™ Fiber Optic Fence Sensor
SuperSleuth Wise. Marketing and Sales Presentation/Training.  Complete video surveillance system in the palm of your hand.  Proven video motion Detection.
1.Overview 2. Hardware 3. Software Interface 4. Triggering 5. Installation 6. Configuring.
THE Reference in Traffic Video Detection 1 Video Detection Sensor for Vehicle Presence Basic Principles, Selection, Installation & Configuration.
Intelligent Outdoor Detector Atsumi Electric Co.,Ltd. TriWatcher SIR10S.
The Detection Series to Envy.
Choosing a Network Camera The top 10 factors for making the right choice.
Beath High School - Int 1 Physics1 Intermediate 1 Physics Electronics Glossary AND gate to device digital signals to inverter LDR to logic circuit logic.
Home Automation Network Solution. 2 Platform Application Cloud 3 rd Party Software iBuilding iPower & Energy iEnvironment iHome e-Home Devices & Sensors.
Home Automation Network Solution. 2 Platform Application Cloud 3 rd Party Software iBuilding iPower & Energy iEnvironment iHome e-Home Devices & Sensors.
Electronic. Analog Vs. Digital Analog –Continuous –Can take on any values in a given range –Very susceptible to noise Digital –Discrete –Can only take.
GVC3200 Video Conferencing System. Conference Room Setup Prepare below equipment before setup: Display Device (e.g., HDTV), with power adapters GVC3200,
Industrial Ethernet active portfolio All models available in standard temperature variants 0°C to +60°C and extended temperature variants -40°C to +75°C.
Introduction to IP Cameras Over Coax. Replacing Analog Cameras With IP Cameras Over Coax Analog Camera RG59U Coaxial Cable 18/2 Power Cable Low Voltage.
Ethernet Line Extensions Gigabit PoE Unmanaged Switches M12 Unmanaged Switches.
FEATURES USER’S MANUAL COLOR BOX CAMERA SDB-BAW SDB-BAW/T 1/3 " SONY 960H Dual Scan CCD High Resolution of 800TV Lines Min. Illumination of Lux at.
VIVOTEK Surveillance Cabinet Solution
Digital-watchdog.com DWC-MF10M36TIR DWC-MF10M8TIR DWC-MF10M28T Presenter’s Name Title | Rev : 04/15 Product Overview 720P Network.
Fire Fighting Robotic Vehicle. Introduction:  It is designed to develop a fire fighting robot using RF technology for remote.
Home Automation Network Solution
Vigilant NetStream Series Overview 12/1/2011. Private & Confidential. Copyright Vigilant Technology 2007 Vigilant NetStream Series IP Cameras Video Encoders.
Vicon MegaPixel & Specialty Network Cameras by Mark Leedy.
Motion Sensors By Elva S. Agbon ICS 30 B MOTION SENSORS A sensor specifically designed to detect a gentle or sharp up and down or side to side motion.
Overview Presentation MKT-DSRV-P- 001E. Product Overview Network based video transmission product with on-board digital recording Allows analogue fixed/PTZ.
DESCRIPTION The DV-IP Encoder is a single channel encoder designed to increase the flexibility of NetVu Connected CCTV networks. Its versatility allows.
Detect Range : 5×5m Detect Angle : 110 Degree Bus Port : HDL-BUS(485bus) Detect distance( sensitivity ): Adjustable via Software, from 1 to 100 Dimension.
Home Automation Network Solution
XBee Based Industrial And Home Security System
Viper Family.
CMS:Children Monitoring System
2N® Helios IP Force.
Motion Sensors By Elva S. Agbon ICS 30 B.
2N® Access Unit Touch Keypad
HX-40/40AM 3.0m high mount outdoor detector HX-40: standard model
Long Range PoE+ Solutions
Intelligent Outdoor Detector
Plug and Play NVR Solution
Home Automation Network Solution
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
2N® Access Unit Touch Keypad
Customer Presentation
2N Access Unit 2.0 Multi-technology access control readers.
Presentation transcript:

Location of installation *Install the detector so that the majority of target activity is across the detection pattern. *The mounting height should be between 2.3m to 4.0m (7.6 to 13ft.). *Mount the unit on a wall or other solid surface. An unstable installation could be a cause of false alarms. Do not install on poles or fences where it is unstable. *Direct or reflected sunlight on the face of the detector can cause false alarms. Set the detection area so it is not effected by direct sunlight, or use the optional Sun hood (SIP MINIHOOD or SIP MIDIHOOD) to help avoid this problem. *Install the REDWALL SIP series away from objects which can block the detection areas. Confirm the detection area can be covered by a camera *Mismatching the detection area and camera views means that operators can not see the crucial image on the monitor screen. The detection area should be within camera view. Basic hints for better system design for Redwall PIR detector

Building Entrance Back door Gate for delivery Gate Vegetation Compressor unit Fence Parking lots Truck yard Basic hints for better system design for Redwall PIR detector 1 To reduce miss alarm Select the installation location so that intruder may cross the detection area. PIR’s are more sensitive to movement made across it’s field of view, and is less sensitive to movement made toward or away from the detector/field of view. Installation location should be selected accordingly. Building Entrance Back door Gate for delivery Gate Vegetation Compressor unit Fence Parking lots Truck yard Detection area Top-view Less sensitive More sensitive Protection for gate, entrance, gate for delivery and back door:

Building Entrance Back door Gate for delivery Gate Vegetation Compressor unit Fence Parking lots Truck yard Basic hints for better system design for Redwall PIR detector 2 To reduce false alarms: Select proper detector which has the same or less detection area to be protected area. Avoid locations where the detector looks towards the object which make extreme sudden temperature change (e.g air- conditioner compressors) and moving objects (e.g. trees, bushes, flags, wildlife trails, etc.). Building Entrance Back door Gate for delivery Gate Vegetation Compressor unit Fence Parking lots Truck yard Over-spilling! The detector watching the compressor! The detector watching the vegetation! If the protection zone is too small for the detector selected, it may cause the unit to “overspill” the detection area. It will create unwanted false alarms. If there is vegetation or objects which create temperature differences, it will result false alarm, too.

Basic hints for better system design for Redwall PIR detector 3 To reduce the risk of tampering or vandalism: Do not install the detector so that the intruder can access the detector from outside its detection area. Install the detector at proper installation height. Do not install the unit too high! The detector should be installed at 7.6 to 13ft. (2.3 to 4m). If the unit installed too low, an intruder can access the detector easily. When this exists, the unit should be installed at a higher position within the rated range. If the unit is installed too high, there will be dead spots which could result in missed alarms. For example, if the SIP-5030 is installed at 26ft. (8m), there will be some dead spots where the unit can not detect people. Also, at a too low position, the detector will be too sensitive (objects appear larger to the detector) and will cause false alarms. Bad! 26ft. 0 50ft.100ft.150ft.

Matching Camera Views If the camera’s field of view can not cover the whole detection area, add another camera to cover the complete zone. Basic hints for better system design for Redwall PIR detector 4

Camera Lens Guide Camera angle Detection angle Basic hints for better system design for Redwall PIR detector 5

Flexible and cost effective installation 1.POE/IP connection 2.Alarm I/O connection with Pre-installed camera (either analog or IP)

System diagram 1 – POE/IP connection Milestone PoE Switch SIP Series Redscan Series AMS Series Connector for alarms Connector for powers Redwall Event Code + PoE PIE-1 Redwall Event Code IP camera PIE-1 Fiber Sensys products PIE-1

PoE Plus splitter functions IEEE 802.3at / IEEE 802.3af compliant DC outputs (24vDC at 0.8A) DC outputs (12vDC at 0.1A) Ethernet converter / Pass-through selectable Ethernet converter Signals can be converted into Redwall Event Codes via TCP/IP or UDP Programmable 5-input NC/NO 10Base-T Note: PoE Transceiver for non-IP Optex sensors

Power supply 12VDC/24VAC Analog IP camera Video Management Software or Network Video Recorder Switch SIP detector ALARM Output TCP/IP ALARM Input Battery version SIP-3020/4010/404 WF series or System diagram 2 – Pre-installed camera connection or Analog camera