Radiation Sources in medicine diagnostic Radiology

Slides:



Advertisements
Similar presentations
Advanced Biomedical Imaging Lecture 3
Advertisements

Technique Guidance Systems
X-Rays In Medicine Noadswood Science, 2013.
Veterinary Radiation Safety 4 Students Radiation Safety MA Law requires that persons who perform diagnostic radiology procedures on animal patients be.
Radiographic Quality Chapter 5.
Topic 3 Selection of kV High kV scattered radiation is energetic. Angle of rays is same as those of primary beam and is not deflected very much. Follows.
Radiation Sources in medicine diagnostic Radiology
Resident Physics Lectures
Analyzing the Image Density. Density Overall blackening of the image.
IAEA International Atomic Energy Agency Responsibility for Radiation Safety Day 8 – Lecture 4.
Bisecting angle technique patient holds the film or sensor with his finger short cone  magnified apexes.
Industrial Radiography
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Radiation Sources in medicine diagnostic Radiology
TIMERS.
Radiation Exposure and Risk John Hamaty. Evaluation of Radiation Exposure Levels in Cine Cardiac Catheterization Laboratories American Association of.
IAEA International Atomic Energy Agency Regulations Part I: Role and Structure of Regulations Day 8 – Lecture 5(1)
Radiographic Grids I By Professor Stelmark.
Quality Control Rad T 110.
x Critical care solutions delivered full circle Dramatically Reduce Risks from.
Control of Scatter Radiation
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.03: Optimization of protection in Mammography.
Radiographic Dosimetry
Current UK legislation and guidelines for radiation protection of patients and staff Prepared by: Dr D. Mladenova.
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
Spot Filming Cinefluorography Fluoro Room Shielding Radiation Areas.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
IAEA International Atomic Energy Agency Interventional Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(3)
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
IAEA International Atomic Energy Agency Dental Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 2(2)
Equipment Design for Radiation Protection
Mammography Questions and Answers
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Inspection Part II.
CT Instrumentation and X-ray system
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
Preparing Variable kVp Technique Charts By Prof. Stelmark.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Historical Review and Modalities in Diagnostics
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.07: Optimization of protection in Mammography.
Radiographic Quality Visibility and Sharpness
Radiographic Equipment
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 15.8: Optimization of protection in radiography.
Part No...., Module No....Lesson No
Radiation Sources in medicine diagnostic Radiology
Radiographic Grids I By Professor Stelmark.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
Doses in Fluoroscopy factors influencing patient doses Colin Martin and David Sutton.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 15.4: Optimization of protection in radiography.
Stacy Kopso, M.Ed., R.T.(R)(M).  Xray photon loses energy and changes direction  Responsible for most of the scatter that fogs the image  Related to.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.04: Optimization of protection in Mammography.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
IAEA International Atomic Energy Agency Fluoroscopy Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(2)
Optimizing The Image RVT: Chapter 7
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 12.1 : Shielding and X-ray room design Practical.
Technique Guidance Systems By Prof. Stelmark. Anatomic Programming Anatomic programming, or anatomically programmed radiography (APR), refers to a radiographic.
Diagnostic Radiology II X-ray Tubes. Anode angle Anode angle defined as the angle of the target surface with respect to the central ray in the x-ray field.
RADIATION PROTECTION 04/12/2016.
Optimisation of Patient Protection for Radiography
Pediatric Radiology By Dr. Wambani, J.S. Chief Radiologist
Radiation protection for paediatric patients
Radiation Protection in Dental Radiology
Resident Physics Lectures (Year 1)
Pediatric Fluoroscopy
Resident Physics Lectures (Year 1)
Pediatric Fluoroscopy
Pediatric Fluoroscopy
Presentation transcript:

Radiation Sources in medicine diagnostic Radiology Pediatric Radiology Day 7 – Lecture 2(3)

Objective To become familiar with the specific devices used in pediatric radiology. To know the specific radiation risk concerning children.

Contents Description of specific equipment and auxiliary devices used for children; Knowledge of appropriate exposure factors in pediatrics; Equipment malfunction affecting radiation protection; Criteria of acceptability and quality control.

Pediatric Equipment Because of their longer life expectancy and their greater sensitivity to radiation, the risk of late radiation effects is greater in children than in adults. In view of this increased radiation risk in younger age, the radiological examination of children (0-15 years) merits special consideration and specific recommendations for pediatric equipment and procedures. Pediatric radiology is a recognised sub-speciality within diagnostic radiology and specific education and training should be obligatory for pediatric radiology practitioners.

Pediatric Equipment (cont) The basic criteria for x-ray equipment used in pediatric radiology are the same as for general purpose equipment. However, additional performance and design requirements are necessary because of the small size of the patients and the special conditions required for many examinations (such as dealing with movement of a child). These include: very short, accurate and reproducible exposure times; collimators adjustable to dimensions that may be smaller than some simple general purpose x-ray equipment may provide. The design and appearance of x-ray rooms are also important to improve the co-operation of children.

Pediatric Equipment (cont) Consequently: powerful generators are necessary for the very short time exposure times required (only 12-pulse or medium-high frequency generators should be used to ensure suitable accuracy and reproducibility); where mobile x-ray equipment must be used (although not advisable), medium or high frequency generators are preferred; low x-ray tube voltages should be avoided whenever practicable. Higher x-ray tube voltages and appropriate additional filtration are recommended;

Pediatric Equipment (cont) a nominal focal spot size of between 0.6 mm and 1.3 mm is desirable; the x-ray beam must be carefully restricted to the area of clinical interest by the use of accurate light beam collimation; additional protective shielding must be adapted to children and available in a range of sizes; low attenuation materials between the x-ray tube focus and the image receptor (e.g. table top, cassette, anti-scatter grid) will contribute to dose reduction;

Pediatric Equipment (cont) In infants and younger children, the use of an anti-scatter grid may not always be necessary. Therefore, anti-scatter grids in pediatric equipment must be easily removed by the operator. Some automatic exposure control (AEC) systems may not function satisfactorily due to the wide range of body thickness and proportion in children. Specially designed pediatric AECs have a small mobile detector for use behind a lead-free cassette.

Pediatric Equipment (cont) Careful manual selection of exposure factors may result in lower radiation doses. The selection of faster intensifying screen-film systems, and image intensifiers with high conversion factors, will result in lower radiation doses. Proper patient positioning and immobilisation are essential: immobilization devices must be easy to use without stressing the patient.

Special Equipment for Pediatric Examinations Pediatric Equipment (cont) Special Equipment for Pediatric Examinations

Malfunctions affecting radiation protection Basically the same as for general x-ray systems (see previous lectures) but the tests performed and the measuring instruments used shall be adapted to pediatric equipment. Quality control programmes are especially important in pediatric radiology services.