Experts in Chem-Feed and Water Treatment beta Metering Pumps 1.

Slides:



Advertisements
Similar presentations
Product Overview. Diaphragm Pumps – Basic Features Self-Priming Abrasives/Slurries High Viscosity Fluids No Electric Motor Run Dry Capability Variable.
Advertisements

Prescient II Extinguishing Control Panels
Variable Frequency Drives Bypass Options
Sequential Process Control
Purpose of a VPA Filling & Metering Pump… Imagine having an employee who constantly measures out a precise dose of liquid whenever it’s needed.
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
OFFICINE MECCANICHE GALLARATESI
Datasheet System Conquest 6_ _01 1/9 CONQUEST 6 Electronic control system for whirlpool Product datasheet VALANTIS SARL CH – 2610 ST-IMIER.
4Identifying Leakage Source (Mech/ Elec) 4Mechanical Air Leak- Down 4Mechanical Air Leak- Up 4Electronic Drift- Up/ Down 4Load Cell Operation 4Understanding.
Metering Pumps and Pump Systems
Clean Air Box Usage & Care CABs RAMs CO Monitors.
Linkage Connecting system components. Allows configuring automatic actions Triggering outputs based on specific inputs Used for removing human reliance.
Bmd Crossvent 3.
DP Cabinet.
LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps.
1 The ProMus Pump A New Direction in ProMinent Metering Pumps.
Actuators.
battery care  Proteggono le batterie  Ne esaltano le prestazioni  Ne preservano la durata nel tempo I Carica Batterie cambiano filosofia.
AccuMax Multi-Point Injection Mechanics
Experts in Chem-Feed and Water Treatment General Hydraulics Fluid Mechanics.
Pump Application Interface. 30 October 2006 Overview Increases the functionality of the soft starter for pumping applications - four additional trip inputs.
Logic Functions OR Operation
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
Lease Automatic Custody Transfer
1 Light OP 504 ex – Project Presentation Luca Invernizzi Design.
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
Water Handling Operations
Features: ERTL TESTED  Displays distance to leak location in meters.  Indicates Cable break condition.  Modbus Output for BMS Monitoring.  Operates.
Northvale Korting Fluid Jet Theory and Applications of Eductors By Patrick Belcher.
Experts in Chem-Feed and Water Treatment An Overview of Possibilities Dulcometer Disinfection Controller ( DDC )
Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.
4 May I/O Control. 4 May What is I/O Control? A Doors feature that allows you to program input events to drive output responses – for example:
Hydraulic Symbols. Piping and Tubing Symbols Normal working line Flexible working line Pilot line Drain line Enclosure outline Direction of flow.
Mazzei Injector Company, LLC
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
Your Connectivity Partner. Locations Main Office: High Tech Products Lallio, Italy USA Office: HTP Connectivity Parsippany, NJ.
June 1999ProMinent Fluid Controls1 alpha Series Metering Pumps ProMinent noelt: NEW CI noelt: NEW CI.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
Experts in Chem-Feed and Water Treatment Solenoid versus Motor-driven.
Customer: Fermin Reyegadas, Fundacion Cantaro Azul Faculty Mentor: Sarah Brownell Background: Cantaro Azul is a non-profit dedicated to helping people.
Experts in Chem-Feed and Water Treatment Delta Presentation.
Engineer Training UV Electrical Cabinet (1-15) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 1-15)
Experts in Chem-Feed and Water Treatment Where Are The Opportunities & What Are The Applications.
Training Session August 11, Nitro Express Features Probe or probeless operation from the same unit Compact splash resistant ABS enclosure Pre-wired.
Makro Series Metering Pumps
Experts in Chem-Feed and Water Treatment Specialty Metering Pumps and Feed Equipment ProMinent Orlita.
Electro Eye-Hye System II
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Experts in Chem-Feed and Water Treatment EXtronic Explosion-Proof Pump.
New Product Developments World Leaders in Combustion Management Solutions Mk7 Expansion PCB Mk7 Expansion PCB.
ADT490 TroubleShooting Locating Opens A. 2 Introduction Breakdown in Circuit Integrity -> Trouble Metallic continuity interrupted an “ open ” occurs System.
CUE – Make Any Pump an E-Pump
Hydro Multi-B – (2) or (3) CME Pumps in Parallel
Service Section Technical Training December 2005.
0-10V Ballast Dimmer HDL-MRDA HDL-MRDA channel 10A DC0 - 10V output module is a multifunction control module. It has 6 channel relay.
BUrners TRAining CEntre GAS BURNERS N 120, 200, 400 N 120, 200, 400 series.
Automating Your Water Treatment Program Presented by:
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
TYPE “HOS” 6” Stroke Compressor & Ancillary Equipment
REACH 1 REACH REACH Introduction Capacity range 0.28 l/h, 4 bar
Quick Start Guide for Flex Flow Pump
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
HIGH PERFORMANCE PRESSURE SYSTEMS.
ME444 ENGINEERING PIPING SYSTEM DESIGN
Lesson 14: Introduction To Sequential Control
MINNY 16 TROUBLESHOOTING Doc THE MACHINE DOES NOT START
ET 438B Sequential Control and Data Acquisition
CONCEPT® plus Solenoid Dosing Pump.
Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.
WEMCO® Hydrogritter® II Complete Grit Removal Package
Presentation transcript:

Experts in Chem-Feed and Water Treatment beta Metering Pumps 1

Experts in Chem-Feed and Water Treatment 2  Microprocessor-based and available in two drive (solenoid) sizes: beta/4 and beta/5.  Maximum capacity for the beta/4 is 5.3 gph; the beta/5 is 8.4 gph.  Features include:  Continuous stroke length adjustment  Stroke frequency adjustment  LED fault indicators  Convex diaphragm  Auto-degassing liquid end  External access to relay outputs

Experts in Chem-Feed and Water Treatment beta Features 3 Stroke Length Adjustment Knob LED Fault Indicators Level Switch Port Multifunction Switch Power Input (detachable) External Control Port

Experts in Chem-Feed and Water Treatment Stroke Length Adjustment  Stroke length (fluid displacement per stroke) is manually adjustable using the stroke length knob.  The scale is from 0% to 100% of the maximum stroke length at a ratio of 10:1. 4

Experts in Chem-Feed and Water Treatment Multifunction Switch  The multifunction switch has settings for manual stroke frequency, external pulse contact, stop and test modes.  Stroke frequency control is adjustable in 10% increments from 10 to 100%.  External pulse is a voltage-free on/off contact. The Stop setting will stop the pumping. The test setting is used for priming the pump. It overrides any of the pump settings and strokes at 100% of the pump frequency 5

Experts in Chem-Feed and Water Treatment LED Indicators  The 3 LED’s indicate the pump’s operating status:  The green LED flashes with each pump stroke indicating normal pump operation.  The yellow LED lights when the liquid level drops below the first float switch triggering level.  The red LED lights in the presence of faults such as low tank level (with option float switch) 6

Experts in Chem-Feed and Water Treatment 7 Cable Signals A 5-wire control cable is used for external control. Close brown and black to run, or open them to pause the pump. Use brown and black together for remote pause or pulse signals. Pause: brown External (+): white Not configured: blue Reference potential: black Auxiliary frequency: gray

Experts in Chem-Feed and Water Treatment Relay Outputs  An external panel in the base of the pump enables optional relays to be installed on-site.  The Relay Output can provide fault annunciation, pace a slave pump or allow stroke counting on an external counter.  The SPDT relay is available for collective fault indication as either pulling in or dropping out (which also alarms on loss of power). 8

Experts in Chem-Feed and Water Treatment Liquid End Options  Liquid end materials include:  Polypropylene (Viton or EPDM seals)  PVC (Viton or EPDM seals)  Acrylic (Viton or EPDM seals)  Carbon-filled Teflon-PTFE (PTFE seals)  316 Stainless Steel (PTFE seals)  Liquid ends are available with or without a bleed valve. An auto- degassing liquid end is also available for fluids that outgas.  Some liquid ends are interchangeable between the beta/4 and beta/5 versions. 9

Experts in Chem-Feed and Water Treatment 10 Liquid End w/o Bleed Valve Discharge Valve Suction Valve

Experts in Chem-Feed and Water Treatment 11 Liquid End with Bleed Valve Discharge Valve Bleed Valve Suction Valve Acrylic liquid end shown. Polypropylene and PVC bleed valves are on the side of the liquid end.

Experts in Chem-Feed and Water Treatment 12 Auto-degassing Liquid End Auto-degassing Port (discharges back to tank) Discharge Valve Suction Valve The auto-degassing liquid ends for beta pumps automatically evacuate gas bubbles entrained in the solution to prevent the pump from becoming airlocked. The pump can self- prime against system pressure so it does not lose prime.

Experts in Chem-Feed and Water Treatment 13 beta/4 Capacities VersionPSIGGPHml/strkStrk/minConnectorsSuction Lift (ft) /4 x 3/ /4 x 3/ /4 x 3/ /2 x 3/ /2 x 3/ /2 x 3/ /2 x 3/8 6.5 Auto-degassing Liquid Ends VersionPSIGGPHml/strkStrk/minConnectorsSuction Lift (ft) /4 x 3/ /4 x 3/ /2 x 3/ /2 x 3/ /2 x 3/ /2 x 3/86.5

Experts in Chem-Feed and Water Treatment 14 beta/5 Capacities VersionPSIGGPHml/strkStrk/minConnectorsSuction Lift (ft) /2 x 3/ /2 x 3/ /2 x 3/ /2 x 3/ /2 x 3/8 6.5 Auto-degassing Liquid Ends VersionPSIGGPHml/strkStrk/minConnectorsSuction Lift (ft) /2 x 3/ /2 x 3/ /2 x 3/ /2 x 3/8 8.2

Experts in Chem-Feed and Water Treatment Features  High Viscosity Liquid Ends  PVDF  With valve springs  Viscosity up to 3000 Centipoises  Types 1005/1605, , 0413/0713 and 0220/0420  Low Voltage Version  VDC and 24 V AC/DC  Available for all pump types  Auto-degassing Liquid Ends 15