RICH Detectors for Particle ID 1 F. Sabatie Bochum Meeting CLAS12 JLab: Base configuration: 2 sectors ~1 m 2 photon detector per sector Extension.

Slides:



Advertisements
Similar presentations
Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY.
Advertisements

Andrej Studen, Karol Brzezinski, Enrico Chesi, Vladimir Cindro, Neal H. Clinthorne, Milan Grkovski, Borut Grošičar, Klaus Honscheid, S. S. Huh, Harris.
PHENIX Decadal Plan o Midterm upgrades until 2015 o Long term evolution after 2015 Dynamical origins of spin- dependent interactions New probes of longitudinal.
Generic Detector R&D for an Electron Ion Collider Advisory Committee meeting Dec , 2012 T. Ludlam
CLAS12 – RICH PARAMETERDESIGN VALUE Momentum range3-8 GeV/c  /K rejection factor Not less than 500  /p rejection factor Not less than 100 Angular coverage5.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
Medical Imaging Mohammad Dawood Department of Computer Science University of Münster Germany.
The Tagger Microscope Richard Jones, University of Connecticut Hall D Tagger - Photon Beamline ReviewJan , 2005, Newport News presented by GlueX.
Instrumentation for medical physics applications Barbara Camanzi, PPD/RAL Instrumentation for radiotherapy Imaging: 1. Fast Time Of Flight PET 2. Electron.
Beam Test Results for a Large-area GEM Detector Read Out with Radial Zigzag Strips Aiwu Zhang, V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger Dept. of.
STAR and meRHIC James Dunlop 1. Heavy Flavor Tracker (2013) Tracking: TPC Forward Gem Tracker (2011) Electromagnetic Calorimetry: BEMC+EEMC+FMS (-1 ≤
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
Update on Silicon Photomultipliers Yi Qiang (Hall-D) Jefferson Lab S&T Review May 10, 2011.
Unique Capabilities – Det./Elect.Missed Opportunities – Det./Elect. Novel detectors and instrumentation for particle detection and beam diagnostics Calorimeters.
Response of the sensors to different doses from tests in Israel Radiotherapy is used as a treatment in around 50% of cancer cases in the UK. Predominantly,
Medical Image Analysis Dr. Mohammad Dawood Department of Computer Science University of Münster Germany.
Possibility for Double DVCS measurement in Hall A Alexandre Camsonne SBS Meeting June 4 th 2013.
EIC Detector – JLab – 04/June/2010 Cisbani / HERMES RICH 1 HERMES: Forward RICH Detector Evaristo Cisbani / INFN-Rome Sanità Group Most of the slides from.
POETIC 2012 Indiana University R. D. McKeown 12 GeV CEBAF.
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
Cancer Therapy and Imaging Cancer Therapy and Imaging Rob Edgecock STFC Rutherford Appleton Laboratory.
CLAS12 – RICH PARAMETERDESIGN VALUE Momentum range3-8 GeV/c  /K rejection factor Not less than 500  /p rejection factor Not less than 100 Angular coverage5.
HEALTH Novel MR-compatible PET detectors for simultaneous PET/MRI imaging FP7-HEALTH-2009-single-stage The focus should be to develop novel.
HPS Beamline: Background Rates, Sensitivity to Field Uncertainties M. Ungaro1HPS Collaboration Meeting, JLAB, May Concrete Wall thickness Study.
Forward photon measurement and generic detector R&D Y. Kwon Yonsei Univ.
Paolo Beltrame ER at CERN since April 2009 Advanced Photodetectors No details… only descriptions and feelings.
16. January 2007Status Report On Compton Imaging Projects 1 Status Of Compton Imaging Projects Carried Out In The CIMA Collaboration HPD Brain PET Meeting.
Latifa Elouadrhiri Jefferson Lab Hall B 12 GeV Upgrade Drift Chamber Review Jefferson Lab March 6- 8, 2007 CLAS12 Drift Chambers Simulation and Event Reconstruction.
Enhancing InBeam PET with single Photon (Compton) Detection CERN September 2nd 2008 VALENCIA GROUP, IFIMED José M. Benlloch (PET hardware, speaker) José.
F.-H. Heinsius (Universität Freiburg) on behalf of the COMPASS collaboration Gluon polarization measurements at DIS 2004, Štrbské Pleso,
 The zigzag readout board is divided into eight η-sectors; each sector has a length of ~12 cm and comprises 128 zigzag strips; zigzag strips run in radial.
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Future Possibilities for Measuring Low Mass Lepton Pairs in Christine Aidala for the Collaboration Quark Matter 2002, Nantes.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
ESTAR Upgrade Ming Shao USTC. eRHIC – the future of RHIC STAR Regional Meeting, Weihai, /24/2012.
Early Career Internal Review Upgrade and development for calorimetry for Deeply Virtual Compton Scattering Alexandre Camsonne November 18 th 2011 VI. Nuclear.
A. G. Argentieri 1), E. Cisbani 2), S. Colilli 2), F. Cusanno 2), R. De Leo 1), R. Fratoni 2), F. Garibaldi 2), F. Giuliani 2), M. Gricia 2), M. Lucentini.
The 12 GeV equipment Hall D – Hall D – GLUEx detector for photoproduction experiments Hall B – Large acceptance detector CLAS12 for high luminosity measurements.
Calorimeters Design Issues and Simulation Needs C.Woody Physics Department Brookhaven National Lab EIC Simulation Workshop Oct 9, 2012.
EPHENIX for eRHIC 1 Mostly from Sasha’s Presentation from DIS.
July 27, 2002CMS Heavy Ions Bolek Wyslouch1 Heavy Ion Physics with the CMS Experiment at the Large Hadron Collider Bolek Wyslouch MIT for the CMS Collaboration.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Jin Huang Brookhaven National Lab. eRD14 meeting Jin Huang 2 ~ →2020~2025Time Current PHENIX sPHENIX (+fsPHENIX) An EIC detector  14y+ operation.
RICH studies for CLAS12 L. Pappalardo1 Contalbrigo Marco Luciano Pappalardo INFN Ferrara CLAS12 RICH Meeting – JLab 21/6/2011.
Transverse Spin Physics with an Electron Ion Collider Oleg Eyser 4 th International Workshop on Transverse Polarisation Phenomena in Hard Processes Chia,
Simulations in Medical Physics Y. TOUFIQUE*, R.CHERKAOUI EL MOURSLI*, M.KACI**, G.AMOROS**, *Université Mohammed V –Agdal, Faculté des Sciences de Rabat,
Technology and R&D Summary and next steps Burkhard Schmidt.
Instrumentation for radiotherapy Imaging: 1. Fast Time Of Flight PET
CLAS12 – RICH RICH - TECHNICAL PARAMETERS PARAMETER DESIGN VALUE
FINAL YEAR PROJECT 4SSCZ
Advances in Imaging Instrumentation for Nuclear Cardiology
EUDET JRA3, Activity Obninsk State University
Prospecting for Gold: Particle Detectors
SiD Calorimeter R&D Collaboration
At HSTD8 in The Special Session In Honour Of Prof. Takashi Ohsugi
Summary of the Compton-PET project
Next-DIS Program Innovative PID solutions based on Cherenkov detectors
HARPO: Gamma ray telescope and polarimeter in MeV-GeV range Philippe GROS LLR, École Polytechnique for the HARPO collaboration 04/12/2015 Atelier accéleration.
Application of Nuclear Physics
Particle Identification in LHCb
Preparation of the CLAS12 First Experiment Status and Time-Line
A multichannel compact readout system for
Function and Structure in
T. Bowcock University of Liverpool For the LHCb Collaboration
ASPID (Application of Silicon Photomultipliers to Imaging Detectors)
Assist. Prof. Dr. Ilker Ozsahin Oct
Nuclear Medicine Technologies
Background Concept Results Conclusions
PHYS 3446 – Lecture #18 Monday ,April 9, 2012 Dr. Brandt Calorimeter
Presentation transcript:

RICH Detectors for Particle ID 1 F. Sabatie Bochum Meeting CLAS12 JLab: Base configuration: 2 sectors ~1 m 2 photon detector per sector Extension to additional sectors only possible with cost-effective photon-detectors Semi-inclusive DIS to study 3D nucleon structure and hadronization; Hadron ID for flavor sensitivity RICH technology to cover few-GeV forward hadron momenta Typical EIC:        p (GeV) Similar RICH requirements -> development of JLab applies to EIC

T = -25 o 2 Cost-Effective Photon Detectors Micro-channel Large-Area Picosecond Photon-Detectors (in collaboration with JLab, USA) Project goal: cost-effectiveness, compact size, excellent time resolution, good tolerance to magnetic field F. Sabatie Bochum Meeting Performance comparable to a MA-PMT Based on novel devices undergoing rapid evolution in performance gain and cost reduction Silicon Photomultipliers (in collaboration with manufacturers, e.g. FBK, Italy) Rapid evolution of the technology needs extensive characterization and dedicated readout electronics

3 Application: Medical Imaging Compton Camera: 3D imaging without tomography by gamma tracking (in collaboration with Italian Health Institute, ISS) Project goal: large area coverage to limit and control the patient assumed dose F. Sabatie Bochum Meeting 0.1 MeV Compton Arc Tracker/Sc atterer Adsorber + Photon Detector Potential Benefits: -Higher efficiency than SPECT -No intrinsic limit to spatial resolution (e.g. positron range in PET) -Broad applicability broader set of radionuclides than PET real-time dose control in radiotherapy Complex, no clinic system in operation yet Perfect application challenge for HPH detector R&D activities Proof-of-principle use of cost-effective devices: GEM or micro-megas as tracker SIPM or LAPP as photon detector

4 Description of Work F. Sabatie Bochum Meeting Deliverables: Tasks and subtasks: