MSmcDESPOT A Brief Summary April 2, 2009. The Technique mcDESPOT (multi-component driven equilibrium single pulse observation of T1/T2) is a quantitative.

Slides:



Advertisements
Similar presentations
VBM Voxel-based morphometry
Advertisements

MRI preprocessing and segmentation.
Gordon Wright & Marie de Guzman 15 December 2010 Co-registration & Spatial Normalisation.
Journal Club: mcDESPOT with B0 & B1 Inhomogeneity.
Statistical Parametric Mapping
Introduction to Functional and Anatomical Brain MRI Research Dr. Henk Cremers Dr. Sarah Keedy 1.
Basics of fMRI Preprocessing Douglas N. Greve
OverviewOverview Motion correction Smoothing kernel Spatial normalisation Standard template fMRI time-series Statistical Parametric Map General Linear.
Coregistration and Normalisation By Lieke de Boer & Julie Guerin.
Preprocessing: Coregistration and Spatial Normalisation Cassy Fiford and Demis Kia Methods for Dummies 2014 With thanks to Gabriel Ziegler.
Introduction to Functional and Anatomical Brain MRI Research Dr. Henk Cremers Dr. Sarah Keedy 1.
More MR Fingerprinting
All Hands Meeting 2005 MRI Calibration Update Morphometry BIRN.
Diffusion Tensor MRI And Fiber Tacking Presented By: Eng. Inas Yassine.
Relaxometry & Image Processing Technical Update Clinical Findings/Product Need Competitive Info Recommendations T1 (DESPOT1 and LL) parameter fitting via.
MSmcDESPOT A look at the road behind and ahead October 30, 2009.
ISMRM 2010 Quantitative Imaging and MS. N. D. Gai and J. A. Butman, NIH T1 Error Analysis for Double Angle Technique and Comparison to Inversion Recovery.
Introduction: The lesion-centered view on MS __________________________________________________________________ RRI/TUD/StanU – HH Kitzler Specific Aims:
MSmcDESPOT: Follow-Ups November 1, Where We Are Baseline cross-section conclusions: – DVF is sensitive to early stages of MS where other measures.
Declaration of Conflict of Interest or Relationship I have no conflicts of interest to disclose with regard to the subject matter of this presentation.
The structural organization of the Brain Gray matter: nerve cell bodies (neurons), glial cells, capillaries, and short nerve cell extensions (axons and.
Automated Labeled Cortical Distance Mapping Pipeline for Analyzing Regional Structures Rodd Pribik 1, Kathryn Alpert 2, Nikhil Mohan 1, JaeHo Sohn 1, Carey.
Analysis of Differential Expression T-test ANOVA Non-parametric methods Correlation Regression.
MSmcDESPOT: Baseline vs. 1- year Diagnosis. N008 Baseline SPGR.
Multimodal Visualization for neurosurgical planning CMPS 261 June 8 th 2010 Uliana Popov.
Preprocessing II: Between Subjects John Ashburner Wellcome Trust Centre for Neuroimaging, 12 Queen Square, London, UK.
Voxel Based Morphometry
Whole Brain Myelin Imaging with mcDESPOT in Multiple Sclerosis
MNTP Trainee: Georgina Vinyes Junque, Chi Hun Kim Prof. James T. Becker Cyrus Raji, Leonid Teverovskiy, and Robert Tamburo.
Progress in hyppocampal box extraction (MAGIC5 Lecce)‏ Marco Favetta on behalf 1.Code Reorganization (LE – Done)‏ 2.Code Optimization (LE - Work in progress)‏
7T Thalamus and MS Studies Jason Su Sep 16, 2013.
ISMRM2012 Review Jun 4, 2012 Jason Su. Outline Parametric Mapping – Kumar et al. A Bayesian Algorithm Using Spatial Priors for Multi-Exponential T2 Relaxometry.
Brain Mapping Unit The General Linear Model A Basic Introduction Roger Tait
Coregistration and Spatial Normalisation
Trade-offs between Angular and Spatial Resolution in High Angular Resolution Diffusion Imaging Liang Zhan 1, Neda Jahanshad 1, Alex D. Leow 2,3, Matt A.
J OURNAL C LUB : Lankford and Does. On the Inherent Precision of mcDESPOT. Jul 23, 2012 Jason Su.
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
Diffusion Tensor Imaging: The Nitty Gritty Brought to you by: Meenal and Erica November 2, 2010.
Medical Image SBIA.UPenn Christos Davatzikos Director, Section of Biomedical Image Analysis Professor, Radiology,
I271B The t distribution and the independent sample t-test.
National Alliance for Medical Image Computing Segmentation Foundations Easy Segmentation –Tissue/Air (except bone in MR) –Bone in CT.
J OURNAL C LUB : Deoni et al. One Component? Two Components? Three? The Effect of Including a Nonexchanging ‘‘Free’’ Water Component in mcDESPOT. Jan 14,
Voxel-based morphometry The methods and the interpretation (SPM based) Harma Meffert Methodology meeting 14 april 2009.
Statistical Parametric Mapping Lecture 11 - Chapter 13 Head motion and correction Textbook: Functional MRI an introduction to methods, Peter Jezzard, Paul.
National Alliance for Medical Image Computing Core What We Need from Cores 1 & 2 NA-MIC National Alliance for Medical Image Computing.
Spatial Smoothing and Multiple Comparisons Correction for Dummies Alexa Morcom, Matthew Brett Acknowledgements.
SPM Pre-Processing Oli Gearing + Jack Kelly Methods for Dummies
NA-MIC National Alliance for Medical Image Computing Evaluating Brain Tissue Classifiers S. Bouix, M. Martin-Fernandez, L. Ungar, M.
Statistical Analysis An Introduction to MRI Physics and Analysis Michael Jay Schillaci, PhD Monday, April 7 th, 2007.
Handout Six: Sample Size, Effect Size, Power, and Assumptions of ANOVA EPSE 592 Experimental Designs and Analysis in Educational Research Instructor: Dr.
MultiModality Registration Using Hilbert-Schmidt Estimators By: Srinivas Peddi Computer Integrated Surgery II April 6 th, 2001.
MPRAGEpre – Image Quality Quality is fairly consistent throughout subjects but there are a couple notable outliers: P003 & P025.
P025 MPRAGE Pre-Contrast. P025 MPRAGE w/ Z-Score < -4.
J OURNAL C LUB : S Magon, et al. University Hospital Basel, Switzerland “Label-Fusion-Segmentation and Deformation-Based Shape Analysis of Deep Gray Matter.
Segmentation with Corrected MPRAGE Scans and FSL Jason Su.
Date of download: 5/28/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Large, Nonplateauing Relationship Between Clinical.
A CCELERATED V ARIABLE F LIP A NGLE T 1 M APPING VIA V IEW S HARING OF P SEUDO -R ANDOM S AMPLED H IGHER O RDER K-S PACE J.Su 1, M.Saranathan 1, and B.K.Rutt.
Submitted by :- Sridev Shyam K.V. Problem Definition.
Baseline and longitudinal patterns of brain atrophy in MCI patients, and their use in prediction of Short- term conversion to AD: Results from ADNI Xuejiao.
Restriction Spectrum Imaging in Multiple Sclerosis
Statistics in MSmcDESPOT
ISMRM 2011 E-Poster #4643 mcDESPOT-Derived MWF Improves EDSS Prediction in MS Patients Compared to Atrophy Measures Alone J.Su1, H.H.Kitzler2, M.Zeineh1,
Computational Neuroanatomy for Dummies
MRI of articular cartilage in OA: novel pulse sequences and compositional/functional markers  Garry E. Gold, Deborah Burstein, Bernard Dardzinski, Phillip.
Brain Fraction and SPM Normalized Penumbra
BSSFP Simulations The goal of these simulations is to show the effect of noise on different pcSSFP reconstruction schemes Further examine the uniformity.
Voxel-based Morphometric Analysis
Anatomical Measures John Ashburner
DISCO-mcDESPOT Nov. 6, 2011 Jason Su.
Presentation transcript:

MSmcDESPOT A Brief Summary April 2, 2009

The Technique mcDESPOT (multi-component driven equilibrium single pulse observation of T1/T2) is a quantitative MR technique that characterizes many of the key parameters relevant to MRI A series of spoiled gradient echo (SPGR) and phase- cycled steady-state free precession (SSFP) scans are collected at different sets of flip angles The signal from a single voxel across all these scans is modeled as the combination of two different pools of water, a fast and slow pool in exchange with each other

The Technique

Comparison of acquired data and single- and two-component SPGR and bSSFP signal intensity vs. flip angle curves in four different brain regions (shown by the box outlines). Plotted data points correspond to the mean values obtained from the ROI, and the error bars represent 1 SD. In all regions, the two-component model is observed to more closely agree with the acquired multiangle SPGR and bSSFP data. A fitting algorithm (stochastic region of contraction) computes the optimal set of parameters that characterizes the observed signal at each voxel in the brain

The Technique The final result is a set of 10 maps defining MR parameters throughout the entire brain: – Fast pool T1, T2, and residence time – Slow pool T1 and T2 – Single pool T1, T2, and M 0 – this is when we do not model each voxel as the sum of two pools – B0 off-resonance – Fast volume fraction – this is how much each pool contributes to a voxel’s signal or alternatively, what fraction of a voxel is occupied by each pool We attribute the fast pool to water trapped between the lipid bilayers of the myelin sheath, while the slower-relaxing species is believed to correspond to the less restricted intra- and extracellular pools – This needs further histological verification but we will continue under this premise – Thus we rename the fast volume fraction to the “myelin water fraction” (MWF), our key parameter of interest

The Study Given this technique, which we believe can characterize myelination in the brain, we move our sights to examine a disease that is characterized by demyelination: multiple sclerosis 23 normals + 2 pending 25 MS patients, 5 in each of 5 classes (low-risk CIS, high-risk CIS, RR, SP, PP) Each scanned at 1.5T to avoid B1 inhomogeneity and flip angle inaccuracy: – mcDESPOT protocol at 2mm 3 isotropic – 32-direction DTI sequence at 2.5mm 3 – T2/PD FSE at 0.43mm 2 in-plane and 6mm slice resolution – FLAIR at 0.86 mm 2 in-plane and 3mm slice resolution – MPRAGE pre and post Gd constrast for patients at 1mm 3

Preprocessing for mcDESPOT Prior to running the fitting algorithm, we must run the SPGR and SSFP images through a preprocessing pipeline Using the FMRIB Software Library (FSL) 1.Linear coregistration – so that each voxel across all the images is the same piece of physical tissue 2.Brain extraction from skull– to reduce computation time

Preprocessing DTI Similarly, the diffusion weighted images must also be coregistered for eddy current correction and brain extracted

Processing Now that the data is all prepared, it is run through the parameter fitting program The mcDESPOT volumes are processed with our own code The diffusion volumes are fitted with FSL’s dtifit

mcDESPOT Maps

mcDESPOT Maps - MWF

DTI Maps Fraction AnisotropyMean Diffusivity

Postprocessing Postprocessing involves bringing these various maps and scans into a standard space so that they can be compared with each other on a voxel per voxel basis We use the 2mm 2 MNI152 T1 standard space template

Postprocessing – mcDESPOT The mcDESPOT coregistration target for each subject is nonlinearly registered to the MNI brain and this warp field is in turn applied to the 10 mcDESPOT maps The warp field is found with FSL’s FNIRT using an 8mm 3 warp resolution

Standard Space Reg. – SPGR Target MNI MNI152 2mmmcDESPOT SPGR FA 13 Registration Target

Postprocessing – DTI The DTI FA map for each subject is nonlinearly registered to the FMRIB58 map Alternatively, we could register it to the mcDESPOT target and use the already computed warp field

Standard Space Reg. – FMRIB58 FA

Standard Space Reg. – DTI FA

Postprocessing – Clinical Each clinical scan for each patient is linearly registered to the mcDESPOT target Then the target->MNI warp is applied

Analysis Initially, whole brain MWF, z-score based thresholding Wanted to move onto tissue-specific MWF study, particularly these types: WM, GM, NAWM (normal-appearing white matter), NAGM, and lesions only This brings us to the tricky issue of segmentation

Segmentation Difficulty of needing both lesion and tissue classification SPM gives WM/GM from MPRAGE but noisy Lesion pre-selection through a voxel-based FLAIR analysis – Defined two lesion classes: lesion cores and penumbra/DAWM Fairly extensive manual editing

Tissue Segmentation Initial issues with using mcDESPOT SPGR target as segmentation Tried permutations of multi-component segmentation (SPGR, FLAIR, T2, PD) Discussed with Allan Reiss’s group – 2mm 3 too low res., 1mm 3 MPRAGEs better but more noisy – Homogeneity correction with SPM

P018 Uncorrected MPRAGE

P018 Corrected MPRAGE

Tissue Segmentation – Raw WM

Tissue Segmentation – Filtered WM

Tissue Segmentation – Edited WM

Tissue Seg. – WM Comparison FAST WM vs. Edited SPM WM I don’t think FAST does as bad a job as the Reiss group suggested

Lesion Seg. – Core Pre-selection

Lesion Segmentation – Edited Cores

Lesion Seg. – Penumbra/DAWM

More Analysis With these tissues defined, we can now analyze more complex compartments: – WM – NAWM = WM – lesion penumbra – cores – DAWM = lesion penumbra – cores – Lesion cores, focal demyelination

P018 mcDESPOT – Edited SPM WM

P018 mcDESPOT – NAWM

P018 mcDESPOT – DAWM

P018 mcDESPOT – Lesion Cores

P018 mcDESPOT – MWF

Correlation with EDSS

Statistical Methods We intend to use the Wilcoxon rank sum test as our workhorse for statistical comparison This is essentially a non-parametric version of t-test, comparing medians instead of means Unsure about the distribution of MWF and hard to determine with such small sampling

Preliminary Statistical Results These is are old statistics using old tissue classes (i.e. whole brain only) p-values from Wilcoxon rank sum test, reject null hypothesis if <.05 First 6 rows compare patient populations vs normals Significant results: – Demyelinated voxel volume can identify CIS patients – No difference between low and high-risk CIS patients according to these measures Demyelinated Voxel Volume Brain Fraction (WM+GM)/ (WM+GM+ CSF) All Patients Low-Risk CIS High-Risk CIS All CIS SPMS PPMS RRMS vs. SPMS Low vs high- risk CIS

Open Questions and Future Work Other interesting measures – ROI Histogram-based: peak location, skewness, kurtosis – Spatial distribution, true voxel-based analysis Further statistical analysis – Multiple variable regression (ANOVA) – worried about normality constraints – Model selection