RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY

Slides:



Advertisements
Similar presentations
Advanced Biomedical Imaging Lecture 3
Advertisements

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Quality Control in Diagnostic Radiology
Radiation Sources in medicine diagnostic Radiology
International Atomic Energy Agency Angiography Equipment L 4.
DESIGNING FOR RADIATION PROTECTION. TUBE HOUSING  REDUCES LEAKAGE TO LESS THAN 100 mR PER HOUR AT A DISTANCE OF ONE METER FROM HOUSING  One meter is.
CVT 102.  Time  Distance  Shielding.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Radiation Sources in medicine diagnostic Radiology
Talking about Radiation Dose
Radiographic Grids I By Professor Stelmark.
3/2003 Rev 1 II.2.9b – slide 1 of 40 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Part IIQuantities and.
Physics of Radiography
ADC PRE-PATIENT COLLIMATION POST-PATIENT COLLIMATION.
Quality Control Rad T 110.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
International Atomic Energy Agency IAEA Patient Dose Management L 5a.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.03: Optimization of protection in Mammography.
Radiographic Dosimetry
DMI 261 Radiation Biology AndProtection. Unit 2 RADIATION Electromagnetic Spectrum –The frequency range of electromagnetic radiation and the photon wavelength.
HABIS X-RAY PRODUCTION AND EXPOSURE FACTORS X-RAY PRODUCTION AND EXPOSURE FACTORS PREPARED BY PREPARED BY Dr fahad albadr radiology chairman radiology.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
IAEA International Atomic Energy Agency Interventional Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(3)
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
IAEA International Atomic Energy Agency Dental Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 2(2)
Characteristic Radiation in Tungsten Targets Shel l # of electrons Binding energy L Char M Char N Char O Char P Char Eff X-ray Energy.
Part No...., Module No....Lesson No Image Quality and Patient Dose
Fluoroscopy Q&A Robert L. Metzger, Ph.D..
Intervention for Chronic and Emergency Exposure Situations Assessment and Response during Radiological Emergency Dose Assessment Overview Lecture IAEA.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
Paediatric patient dose surveys Colin Martin and David Sutton.
Understanding radiation units L02
Historical Review and Modalities in Diagnostics
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.07: Optimization of protection in Mammography.
Radiation Sources in medicine diagnostic Radiology
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 15.8: Optimization of protection in radiography.
Part No...., Module No....Lesson No
Diagnostic reference levels in Medical Imaging. Concept and practice
Radiation Sources in medicine diagnostic Radiology
Radiographic Grids I By Professor Stelmark.
Fluoroscopy. Real-time imaging Most general-purpose fluoroscopy systems use TV technology, operating at 30 frames/sec May be recorded (barium swallow.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY L13: Occupational Radiation Protection IAEA Training.
Doses in Fluoroscopy factors influencing patient doses Colin Martin and David Sutton.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 15.4: Optimization of protection in radiography.
Course Title : Image Recording
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.04: Optimization of protection in Mammography.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
Introduction By Dr. Nimer Khraim DVMS,BVMS,MVSc.
Basis of Mammography F. Milano Dept. Clinical Physiopathology University of Florence
Medical Physics College Trieste Mammography Quality Control (QC) Franco Milano Dept.Clinical Physiopathology University of Florence
Radiology. The Cathode… Provides a source of electrons and directs the electrons towards to anode. The cathode has a coiled wire filament that emits electrons.
IAEA International Atomic Energy Agency Fluoroscopy Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(2)
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Need for a Regulatory program.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 12.1 : Shielding and X-ray room design Practical.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Optimisation of Patient Protection for Radiography
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
David Sutton or Colin Martin But Borrowed from Jerry Williams
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
Fluoroscopic Image Intensifier Image production
Mobile Fluoroscopy Based on:
Mobile Fluoroscopy Based on:
Pediatric Fluoroscopy
Fluoroscopic Image Intensifier Image Production
Mobile Fluoroscopy.
Test tool for assessing lead equivalence in protective lead apparels
Writing Committee Members et al. JACC 2018;j.jacc
Presentation transcript:

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part No...., Module No....Lesson No Module title IAEA Training Material on Radiation Protection in Diagnostic and Interventional Radiology RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 16.1: Optimization of protection in fluoroscopy Practical exercise Part …: (Add part number and title) Module…: (Add module number and title) Lesson …: (Add session number and title) Learning objectives: Upon completion of this lesson, the students will be able to: … . (Add a list of what the students are expected to learn or be able to do upon completion of the session) Activity: (Add the method used for presenting or conducting the lesson – lecture, demonstration, exercise, laboratory exercise, case study, simulation, etc.) Duration: (Add presentation time or duration of the session – hrs) Materials and equipment needed: (List materials and equipment needed to conduct the session, if appropriate) References: (List the references for the session) IAEA Post Graduate Educational Course in Radiation Protection and Safe Use of Radiation Sources

Part No...., Module No....Lesson No Module title Overview To become familiar with quality control tests in fluoroscopy. To measure the standard entrance dose rate to the patient To assess the patient thickness variation effect on scattered radiation Lecture notes: ( about 100 words) Instructions for the lecturer/trainer 16.1: Optimization of protection in fluoroscopy IAEA Post Graduate Educational Course in Radiation Protection and Safe Use of Radiation Sources

Part 16.1: Optimization of protection in fluoroscopy Part No...., Module No....Lesson No Module title IAEA Training Material on Radiation Protection in Diagnostic and Interventional Radiology Part 16.1: Optimization of protection in fluoroscopy Measurement of standard entrance dose rate Part …: (Add part number and title) Module…: (Add module number and title) Lesson …: (Add session number and title) Learning objectives: Upon completion of this lesson, the students will be able to: … . (Add a list of what the students are expected to learn or be able to do upon completion of the session) Activity: (Add the method used for presenting or conducting the lesson – lecture, demonstration, exercise, laboratory exercise, case study, simulation, etc.) Duration: (Add presentation time or duration of the session – hrs) Materials and equipment needed: (List materials and equipment needed to conduct the session, if appropriate) References: (List the references for the session) IAEA Post Graduate Educational Course in Radiation Protection and Safe Use of Radiation Sources

Fluoroscopy - Standard Dose Rate Purpose : Measurement of dose rate at the entrance of patient for different thickness Effect on scattered radiation Method : Use different water equivalent absorber (acrylic, 20 cm for a standard patient) or copper sheets (2 mm for a standard patient Place dosimeter on input (x-ray tube side) of absorber 16.1: Optimization of protection in fluoroscopy

Set-up for measurement of standard dose rate. 16.2: Optimization of protection in fluoroscopy

The ionization chamber should be protected pressure and possible malfunctioning. It should be in contact with the acrylic to include backscatter in the measurement. 16.2: Optimization of protection in fluoroscopy

Use 10 cm thickness of acrylic to simulate a thin patient Use 10 cm thickness of acrylic to simulate a thin patient. The table to intensifier distance is 35 cm (this distance will be kept constant for the different patient thicknesses) 16.1: Optimization of protection in fluoroscopy

The chamber is easily centred using the fluoroscopic image 16.1: Optimization of protection in fluoroscopy

The entrance dose rate is 1.78 mGy/min. 16.1: Optimization of protection in fluoroscopy

The phantom thickness is now 20 cm. 16.1: Optimization of protection in fluoroscopy

The chamber now reads 8.85 mGy/min. 16.1: Optimization of protection in fluoroscopy

The patient entrance dose rate will increase. If the distance between the input screen of the intensifier and the entrance of the patient is increased, i.e., extra 20 cm. The patient entrance dose rate will increase. 16.1: Optimization of protection in fluoroscopy

Note: the chamber looks magnified (the intensifier is further away from the patient). 16.1: Optimization of protection in fluoroscopy

Before (intensifier-table distance: 35 cm) Now (intensifier-table distance: 55 cm) 16.1: Optimization of protection in fluoroscopy

The entrance dose rate with the intensifier at 55 cm from the table is 17.9 mGy/min (to be compared with the previous value of 8.85 mGy/min). 16.1: Optimization of protection in fluoroscopy

Now the phantom thickness is increased up to 30 cm of acrylic. 16.1: Optimization of protection in fluoroscopy

24.8 mGy/min (the reading was 8.85 with 20 cm thickness). The patient entrance dose rate at the surface of the phantom increases to 24.8 mGy/min (the reading was 8.85 with 20 cm thickness). 16.1: Optimization of protection in fluoroscopy

The dose rate due to scatter radiation also increases with the patient thickness. For 30 cm acrylic, 3 mGy/h is measured close to the phantom. 16.1: Optimization of protection in fluoroscopy

7 mGy/h. The patient entrance dose rate is now 59.6 mGy/min. With the high contrast mode the dose rate for scatter radiation (30 cm acrylic), increases to 7 mGy/h. The patient entrance dose rate is now 59.6 mGy/min. 16.1: Optimization of protection in fluoroscopy

With 10 cm acrylic the dose rate due to scattered radiation is 0.2 mGy/h. 16.1: Optimization of protection in fluoroscopy

With 20 cm acrylic the dose rate due to scattered radiation is 1 mGy/h. 16.1: Optimization of protection in fluoroscopy

With 30 cm acrylic the dose rate due to scattered radiation is 3 mGy/h. 16.1: Optimization of protection in fluoroscopy

Note that with the extra thickness the image quality is extremely poor (the border of the chamber is hardly visible) 16.1: Optimization of protection in fluoroscopy

Fluoroscopy - Standard Dose Rate Analysis : should be < 25 mGy/min Frequency : acceptance, tube change generator repair intensifier repair 6 monthly 16.1: Optimization of protection in fluoroscopy

Where to Get More Information Quality Control in Diagnostic Imaging, Gray JE, Winkler NT, Stears J, Frank ED. Available at no cost. http://www.diquad.com/QC%20Book.html 15.3: Optimization of protection in radiography