Computer controlled I NSTANT R ESPONSE ™ system provides safer and more precise electrosurgery. TM.

Slides:



Advertisements
Similar presentations
Effect of Electricity on Living Tissue
Advertisements

New! KENTAMED RF-B 4MHz surgery 4 MHz radiofrequency surgery
T1 and T2 Values 0.5T Tissues FAT LIVER WHITE M GRAY M CSF
BIOPOTENTIAL AMPLIFIERS
Sensors Interfacing.
KENTAMED Radio B is a cutting-edge technology 4MHz radiofrequency surgery unit. It combines the well-known tissue spearing effects of the radiofrequency.
Surgical Diathermy Machine
Kenny Low Dec 2009 Urology registrar Thursday teaching
EE 4BD4 Lecture 25 Electrosurgery Biomedical Device Technology: Principles and Design, Charles C. Thomas Publisher 2007 Anthony K. Chan 1.
Shortwave and Microwave Diathermy part(2). Induction Electrodes (Drum Electrode) One Or More Monopolar Coils Rigidly Fixed In A Housing Unit May Use More.
Physics 2112 Unit 21  Resonance  Power/Power Factor  Q factor  What is means  A useful approximation  Transformers Outline:
Electrical Surgical Unit
Externally Tested Scan Circuit with Built-In Activity Monitor and Adaptive Test Clock Priyadharshini Shanmugasundaram Vishwani D. Agrawal.
Equivalent Circuits - Resistors Resistor noise is dominated by thermal noise: Noiseless Resistor Noisy Resistor Noise Source.
Electronic Instrumentation Experiment 1 * Part A: Circuit Basics, Equipment, Sound Waves * Part B: Resistors, Circuit Analysis, Voltage Dividers * Part.
This presentation may contain some forward looking statements, particularly regarding operational prospects in 2008 and beyond, which involve a number.
1 Complex Gain: Basic amplifier concepts Q: What is a Phasor? A Phasor is an ac voltage or current that maintains the same phase with respect to a standard.
What is a Watt? Everything you ever wanted to know about Electrosurgery. Fahad bamehriz, MD.
What is electrosurgery?
Diathermy.
Anatomy & Incisions General Surgery. Incisions A variety of incisions are used The type chosen is dependent on a number of factors Access desired Procedure.
Promed Supply Company LTD. Introduction. Agenda Corporate mission Corporate overview Corporate culture & Business ethics Our products 1.PROMED PB400 generator.
Without reference, identify principles about Electrosurgical Units with at least 70 percent accuracy.
PSST 10819_11/2008 Arrhythmia in Practice Today ™ Content provided by Boston Scientific September 2008 Lessons in Lesions.
BJTs. Transistor The transistor is the main building block “element” of electronics. A transistor is a semiconductor device used to amplify and switch.
Vertical deflection system: * The function of the deflection system provides an amplified signal of the proper level to derive the vertical deflection.
470KHz RF LESION GENERATOR Product Name : ThermoCon Model No : TC-50.
BASICS OF ELECTROSURGERY
Electrosurgery & Gyn Surgery: Get the Point Across
Hysteroscopy: General knowledge overview
Operational Amplifiers and Other Integrated Circuit Usage Jimmie Fouts Houston County Career Academy.
Argon Enhanced Electrosurgery. Characteristics of argon gas (helium, neon, freon etc. also possible, but.....) inertnon-explosive heavier than air not.
Equipment Source- Alexander’s Care of the Patient in Surgery Patty Pavlikowski RN CST MA.
RC Circuits Chapter 10 Thomas L. Floyd David M. Buchla DC/AC Fundamentals: A Systems Approach.
PREPAIRED AND PRESNETED BY: DR.HASAN AL-SHEHRI GS RESIDENT UNDER SUPERVISION OF : PROF : MOHMMED ALAM GS CONSULTANT PRINCIPLES AND COMPLECATIONS DIATHERMY.
Electro surg i cal unit  PURPOSE ESU are used for surgical cutting and for controlling bleeding by causing coagulation “ hemostasis ” at the surgical.
Electro surgery in Gynaecology
This presentation may contain some forward looking statements, particularly regarding operational prospects in 2009 and beyond, which involve a number.
Linear Power Supplies, Switched Mode Power Supply
RDT Hospital, Dept of Gen Surgery
Electrosurgical Unit.
A New Dual Current-Mode Controller Improves Power Regulation in Electrosurgical Generators Friedrichs, D. A., Erickson, R. W., & Gilbert, J.
Radio Frequency Osc.. 2- RADIO-FREQUENCY OSCILLATORS Radio-frequency (RF) oscillators must satisfy the same basic criteria for oscillation as was discussed.
BIO POTENTIAL ELECTRODES. ELECTRODES What is an electrode? Device that converts ‘ionic potentials’ into ‘electronic potentials’ They are employed to pick.
AUDIO OSCILLATORS An audio oscillator is useful for testing equipment that operates in the audio-frequency range. Such instruments always produce a sine-wave.
Electrosurgery Units ELECTROSURGICAL UNITS (ESUs)
SAFE USE OF DIATHERMY RACHEAL AFOLABI, RN, RM, H. Dip. PERI-OPERATIVE NURSING, H.Dip. HEALTH SYSTEM MANAGEMENT.
Chapter 2-1 Voltage and Current Sources Resistors Ohms Law.
Laparoscopic surgery Meaning of Laparoscopy Laparoscopy is minimally invasive technique for viewing the internal structure of the abdominal cavity. The.
Average Inductor Current Sensor for Digitally Controlled Switched-Mode Power Supplies Rodríguez, M., López, V. M., Azcondo, F. J., Sebastián,
BME 312 BIOMEDICAL INSTRUMENTATION II LECTURER: ALİ IŞIN LECTURE NOTE 7 Electrosurgical Devices BME 312-BMI II-L7- ALİ IŞIN 2014 FACULTY OF ENGINEERING.
Electro surgical unit.
Energy Efficient Motors and Variable Speed Drives
Biomedical Instruments Design Biopotential Amplifiers
SMPS.
DIATHERMY MISS HIRA JABEEN.
Electrosurgical/Surgical Diathermy Units
ELECTROSURGERY IN LAPAROSCOPY
Operational Amplifiers
CHAPTER 4 RESONANCE CIRCUITS
Voltage and Current Sources Resistors Ohms Law
ELECTROSURGERY IN ENDOSCOPY
SURGICAL DIATHERMY.
SURGICAL DIATHERMY.
Diathermy and its safe use
Agenda Introduction of Protective Relays
Biomedical Instruments Design Biopotential Amplifiers 1.
Biopotential amplifiers
Fundamental Use of Surgical Energy
Presentation transcript:

Computer controlled I NSTANT R ESPONSE ™ system provides safer and more precise electrosurgery. TM

Tissue Response Technology Tissue Impedance INPUT Computer Controlled OUTPUT

Computer Controlled Tissue Response Technology Responds instantly to changes in tissue impedance/resistance. Maintains clinical effect over a wide range of tissue impedances/resistances.

The computer circuit is: Automatically invoked All cut modes All bipolar modes Not applied to coag modes Fulguration capabilities Tissue Response Generator

Tissue types vary in impedance/resistance Effective over a wide range of tissue impedances/resistances Tissue Response Generator The computer circuit senses tissue impedance/resistance

Approximate Tissue Impedance/Resistance Ranges Buzz Hemostats Desiccate - stop bleeding Prostate in nonconductive solution Muscle, Eye, Skin, Kidney, Pancreas Oral Cavity, Liver Gall Bladder Bowel, Brain Gray Matter, Adipose, Spleen Mesentary, Brain White Matter, Omentum Lung, Scar, Adhesions resistance when bloody resistance when dry KEY Resistance in Ohms at Radio Frequency when Cutting or Desiccating Increasing tissue impedance/resistance

Provides instant response to changes in tissue impedance/resistance Produces consistent tissue effect Controls maximum output voltage Reduces capacitive coupling and video interference Minimizes sparking Tissue Response Generator Computer controlled output is automatically adjusted

Thermal Damage Standard ESTissue Response Average thermal spread =.35 mmAverage thermal spread =.14 mm 50% reduction in thermal spread Tissue response produces equivalent tissue effect at lower power settings

Capacitively Coupled Current Measured on a Metal Cannula Tissue Response Standard ES Impedance (ohms) Current (mAmps) Coag at 120 Watts

Peak to Peak Voltage Generator Technology Comparison in Pure Cut Volts Tissue Response Generator

Output Power vs Resistance Tissue Response Pure Cut Mode vs Conventional Pure Cut Modes Resistance in Ohms Output Power in Watts Tissue Response Generator Generator Setting 300W Increasing tissue impedance/resistance

Output Power vs Resistance Tissue Response Generator Tissue Response Blended Cut Mode vs Conventional Blended Cut Mode Resistance in Ohms Output Power in Watts Generator Setting 200W Increasing tissue impedance/resistance

Advantages in Monopolar Provides computer controlled output in: Cut Mode Less thermal damage to adjacent tissue Lower power settings required to achieve desired effect Less sparking Ý reduced stimulation of nerves and muscles Reduced drag Spray Coag Mode Wide area of effect with less spot penetration Tissue Response Generator

Advantages in Bipolar Provides computer controlled output in: Low Delicate tissue Fine control of desiccation Low voltage Ý prevents sparking Med Standard tissue application Low voltage Ý prevents sparking Macro Higher resistance tissue Higher voltage available Designed to function with new generation of laparoscopic instruments Tissue Response Generator

Standard ESTissue Response High voltage causes sticking and charring Reduces power to slow coagulation Reduces power into high impedances to limit cut capability Voltage is limited to reduce sticking and charring Maintains power to speed coagulation Maintains power in high impedance tissue to reduce drag Bipolar Coagulation Macrobipolar

Incorporates previous technology safety features Isolation Return electrode monitoring Functions with other technologies Argon enhanced electrosurgery Accepts current accessories Monopolar electrodes and footswitches Bipolar electrodes and footswitches Tissue Response Generator

Surgical Applications General Laparotomy incision Mastectomy Urology TUR Prostate GYN Orthopedics Plastic Tissue Response Generator Skin Fat Muscle Fascia Peritoneum