KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association INSTITUT FÜR EXPERIMENTELLE KERNPHYSIK www.kit.edu.

Slides:



Advertisements
Similar presentations
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association Institut für Experimentelle Kernphysik
Advertisements

1 of 17 LUKAS PÜLLEN New prototypes for components of a control system for the new ATLAS pixel detector at the HL-LHC New prototypes for components of.
Epitaxial Silicon Detectors for Particle Tracking Overview on Radiation Tolerance at Extreme Hadron Fluence G. Lindström (a), E. Fretwurst (a), F. Hönniger.
Experimental studies of low energy proton irradiation of thin vacuum deposited Aluminum layers T. Renger, M. Sznajder, U.R.M.E. Geppert Chart.
IAP-PAI 25/05/20051 CMS Si Rad. Hardness Introduction Damage in Si Neutron tests => Beam => Irrad. Setup.
New approach to simulate radiation damage to single-crystal diamonds with SILVACO TCAD Florian Kassel, Moritz Guthoff, Anne Dabrowski, Wim de Boer.
128 September, 2005 Silicon Sensor for the CMS Tracker The Silicon Sensors for the Inner Tracker of CMS CMS Tracker and it‘s Silicon Strip Sensors Radiation.
LHC Experiments at Liverpool E2V Visit – Nov 2005 Introduction Si Technology Upgrade/Maintenance Summary.
Irradiation Workshop - KarlsruheA. Dierlamm, IEKP 1 Irradiation with Protons - IQC Karlsruhe IEKP - Universität Karlsruhe (TH)
The LHCb Inner Tracker Marc-Olivier Bettler SPS annual meeting Zürich 21 February 2007.
The performance of LHCf calorimeter was tested at CERN SPS in For electron of GeV, the energy resolution is < 5% and the position resolution.
Planning for Electromagnetic Irradiation Studies of Silicon Strip Sensors at SLAC/SCIPP Viltaliy Fadeyev, Spencer Key *, Donish Khan *, Tom Markiewicz,
Tracker Week April 2002IEKP 1 Irradiation of one CMS ceramic hybrid from Dorazil in Karlsruhe Frank Hartmann IEKP - Universität Karlsruhe (TH)
ATLAS detector upgrades ATLAS off to a good start – the detector is performing very well. This talk is about the changes needed in ATLAS during the next.
TCT+, eTCT and I-DLTS measurement setups at the CERN SSD Lab
October 2001General Tracker Meeting IEKP - Universität Karlsruhe (TH) 1 Results on proton irradiation tests in Karlsruhe F. Hartmann IEKP - Universität.
The SLHC and the Challenges of the CMS Upgrade William Ferguson First year seminar March 2 nd
Status of the PiN diodes irradiation tests B. Abi( OSU), R. Boyd (OU), P. Skubic (OU), F. Rizatdinova (OSU), K.K. Gan (Ohio State U.)
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association Institut für Experimentelle Kernphysik
Semi-conductor Detectors HEP and Accelerators Geoffrey Taylor ARC Centre for Particle Physics at the Terascale (CoEPP) The University of Melbourne.
Status and possibilities for the irradiation facility in the PS East Hall Michael Moll, Maurice Glaser 10 March 2010 – IRRAD Working Group - some notes.
SEE effects in deep submicron technologies F.Faccio, S.Bonacini CERN-PH/ESE SEE TWEPP2010.
Radiation Tolerant Electronics New Policy? Ph. Farthouat, CERN.
High Dose Irradiation of Possible FCAL Sensors at the S-DALINAC Ch.Grah Physics and Detector Meeting DESY HH,
Developments on power transfer at CERN (DC-DC converters) Philippe Farthouat CERN.
The T506 Experiment: Electromagnetically-Induced Radiation Damage to Solid-State Sensors Test Facilities Users Workshop SLAC, September Bruce Schumm.
Diamond Detector Developments at DESY and Measurements on homoepitaxial sCVD Diamond Christian Grah - DESY Zeuthen 2 nd NoRHDia Workshop at GSI Thursday,
Background Simulations for the LHCb Beam Condition Monitor Overview: ● The LHCb Beam Condition Monitor (BCM) – Purpose, Design and Function – Implementation.
A. Macchiolo, 13 th RD50 Workshop, CERN 11 th November Anna Macchiolo - MPP Munich N-in-n and n-in-p Pixel Sensor Production at CiS  Investigation.
Initial Results from the SLAC ESTB T-506 Irradiation Study International Workshop on Future Linear Colliders University of Tokyo, November 2013 Bruce.
3rd NoRDHia 1 TITLE INVESTIGATION OF DIAMOND SAMPLES UNDER HIGH DOSES OF ELECTROMAGNETIC IRRADIATION (at S-DALINAC) Wolfgang Lange, DESY Zeuthen.
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
15 February 2007Dirk Wiedner / LHCb1 Radiation Monitors for LHCb.
Introduction to Irradiation Facilities 1. Challenges at LHC and Why we need Irradiation Facilities (Mar CAPEANS) 2. PH Department Proton and Neutron Facilities.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
3D sensors for tracking detectors: present and future applications C. Gemme (INFN Genova) Vertex 2013, Lake Starnberg, Germany, September 2013 Outline:
15/09/20111 ATLAS IBL sensor qualification Jens Weingarten for the ATLAS IBL Collaboration (2 nd Institute Of Physics, Georg-August-Universität Göttingen)
The LHCb Vertex Locator Lars Eklund LHCb VELO Group of the LHCb Collaboration CERN (Geneva), EPFL (Lausanne), NIKHEF (Amsterdam), University of Glasgow,
Ideas for Super LHC tracking upgrades 3/11/04 Marc Weber We have been thinking and meeting to discuss SLHC tracking R&D for a while… Agenda  Introduction:
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
Radiation Damage Studies for Si Diode Sensors Subject to MRaD Doses Bruce Schum UC Santa Cruz July
Radiation Damage Studies for Si Diode Sensors Subject to MRaD Doses Bruce Schum UC Santa Cruz June
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association INSTITUT FÜR EXPERIMENTELLE KERNPHYSIK
Charge Collection, Power, and Annealing Behaviour of Planar Silicon Detectors after Reactor Neutron, Pion and Proton Doses up to 1.6×10 16 n eq cm -2 A.
1 Giuseppe G. Daquino 26 th January 2005 SoFTware Development for Experiments Group Physics Department, CERN Background radiation studies using Geant4.
The T506 Experiment: Electromagnetically-induced Radiation Damage to Solid-State Sensors Test Facilities Users Workshop SLAC, September Bruce Schumm.
Run II preparations Test beam plans Moving from 156 to 169 DT-LHCb coordination meeting June 2, 2015.
Giulio Pellegrini Actividades 3D G. Pellegrini, C. Fleta, D. Quirion, JP Balbuena, D. Bassignana.
KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association Institut für Experimentelle Kernphysik
1/20 LHCb upgrade, Jeroen van Tilburg Nikhef Jamboree, 14 Dec 2015 Preparing for the LHCb upgrade.
Proton and neutron irradiation facilities in the CERN-PS East Hall Maurice Glaser and Michael Moll CERN- PH-DT2 - Geneva - Switzerland 6 th LHC Radiation.
RD42 Status Report W. Trischuk for the RD42 Collaboration LHCC Meeting – June 12, 2013 Development of CVD Diamond Tracking Detectors for Experiments at.
Upgrade of the irradiation facilities in the PS East Hall Maurice Glaser, Michael Moll 30 April 2010 – PH-DT steering board meeting activities are part.
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
Investigation of the effects of thickness, pitch and manufacturer on charge multiplication properties of highly irradiated n-in-p FZ silicon strips A.
Pixel 3D Sensor Test Beam Analysis
KIT TA Status Felix Bögelspacher, Bärbel Bräunling, Wim de Boer, Alexander Dierlamm Prof. Dr. Max Mustermann | Name of Faculty.
FBK / INFN Roma, November , 17th 2009 G. Darbo - INFN / Genova
Plans for Radiation Damage Studies for Si Diode Sensors Subject to 1 GRaD Doses SLAC Testbeam Workshop March
National Research Center” Kurchatov Institute”
IBL Overview Darren Leung ~ 8/15/2013 ~ UW B305.
Sep th Hiroshima Xi’an Test-beam evaluation of newly developed n+-in-p planar pixel sensors aiming for use in high radiation environment.
TCAD Simulations of Silicon Detectors operating at High Fluences D
(with R. Arcidiacono, A. Solano)
LHCb VErtex LOcator For precision measurements of CP-violation at CERN (GENEVE) HALF of DETECTOR Si strip detector Read-out electronics Secondary vacuum.
LHCb VErtex LOcator ENGINEERING DEPARTMENT
Status of CMS-PPS timing detectors
Forward-bias operation of FZ and MCz silicon detectors made with different geometries in view of their applications as radiation monitoring sensors J.
PERFORMANCE OF THE METAL RADIATION MONITORING SYSTEMS
Radiation damage in Diamond
Presentation transcript:

KIT – University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association INSTITUT FÜR EXPERIMENTELLE KERNPHYSIK Status Report on Irradiations at KIT (WP 7 TA) Alexander Dierlamm and Wim de Boer

A. Dierlamm Institut für Experimentelle Kernphysik AIDA Annual Meeting - WP Irradiation Summary 18 projects with a total of hours of beam time 45 users No visitors We mainly had high fluence irradiations of 1e15 – 1e16 n eq /cm² Beam time per experiment (in hours)

A. Dierlamm Institut für Experimentelle Kernphysik New projects in the last reporting periode AIDA Annual Meeting - WP

A. Dierlamm Institut für Experimentelle Kernphysik AIDA Annual Meeting - WP AIDA-KIT Title: Irradiation of prototype eBoards for the ATLAS nSQP upgrade Group leader: D. Münstermann, CERN, CH Beam time: 0.9h (done) The new Service Quarter Panel (nSQP) project has built replacement services for the ATLAS Pixel Detector. In system tests, it was found that the optical components could safely be replaced by passive elecrical extension boards, so-called eBoards. To ensure long-term reliability, industry standard production methods should be applied. These involve acrylic resins which are generally not rad-hard up to the required TID of 50MRad. It is therefore necessary to conduct irradiation studies of prototype boards. Irradiation of 2 industry standard acrylic eBoards and 2 CERN-made epoxy-based eBoards to a TID of 50 MRad (Si)

A. Dierlamm Institut für Experimentelle Kernphysik AIDA Annual Meeting - WP AIDA-KIT Title: Irradiation of Single Crystal CVD Diamonds Group leader: R. Wallny, Zurich, CH Beam time: 0h (not started yet) Irradiated single crystal CVD diamonds used as particle sensors have exhibited decreasing signal size with increasing incident particle rates. This effect is attributed to polarization of charge within the diamond due to defects near the diamond surfaces. In order to attempt to remove these defects, material has been removed from the surfaces of diamond sensors by reactive ion etching (RIE).

A. Dierlamm Institut für Experimentelle Kernphysik AIDA Annual Meeting - WP AIDA-KIT Title: Irradiation of silicon detectors for AFP experiment Group leader: P. Sicho, CERN, CH Beam time: 0h (not started yet) The AFP experiment is future ATLAS Forward Detector and is foreseen to be installed in the LHC tunnel about 220m far from the centre of the ATLAS detector. AFP silicon detectors will be hit by scattered protons coming from ATLAS interaction point. The detectors will be exposed very nonhomogenously and only small fraction of the sensor area will be exposed to the fluence of ~ pcm -2 /100fb -1. The goal of KIT irradiation is to simulate radiation condition expected at the real experiment and test the behaviour of nonhomogenously irradiated silicon sensors.

A. Dierlamm Institut für Experimentelle Kernphysik AIDA Annual Meeting - WP Publications found so far Dierlamm, A. Silicon sensor developments for the CMS Tracker upgrade. Journal of Instrumentation 7, C01110–C01110 (2012). Da Vià, C. et al. 3D active edge silicon sensors: Device processing, yield and QA for the ATLAS-IBL production. NIM A 699, 18–21 (2013). Grinstein, S. Overview of the ATLAS insertable B-layer (IBL) project. NIM A 699, 61–66 (2013). Rubinskiy, I. Irradiation and beam tests qualification for ATLAS IBL Pixel Modules. NIM A 699, 67–71 (2013). Nagai, R. et al. Evaluation of novel KEK/HPK n-in-p pixel sensors for ATLAS upgrade with testbeam. NIM A 699, 78–83 (2013). Bernard-Schwarz, M. Future silicon sensors for the CMS Tracker Upgrade. NIM A 699, 89–92 (2013). Auzinger, G. Analysis of testbeam data of irradiated silicon prototype sensors for the CMS tracker upgrade. NIM A doi: /j.nima La Rosa, A. et al. Novel silicon n-in-p pixel sensors for the future ATLAS upgrades. NIM A doi: /j.nima Gallrapp, C. Planar pixel sensors for the ATLAS tracker upgrade at HL- LHC. NIM A doi: /j.nima

A. Dierlamm Institut für Experimentelle Kernphysik AIDA Annual Meeting - WP Theses found so far Hoffmann, K.-H. Development of new Sensor Designs and Investigations on Radiation Hard Silicon Strip Sensors for the CMS Tracker Upgrade at the High Luminosity Large Hadron Collider. PhD thesis, KIT, IEKP-KA/ (2013) Frech, S. Einfluss von Strahlenschäden auf Siliziumstreifensensoren aus unterschiedlichen Grundmaterialien, diploma thesis, KIT, IEKP- KA/ (2012) Altan, L. Untersuchung zur Ladungsmultiplikation an hoch bestrahlten Siliziumstreifensensoren, diploma thesis, KIT, IEKP-KA/ (2012)

A. Dierlamm Institut für Experimentelle Kernphysik AIDA Annual Meeting - WP Outlook for Expect application for additional CMS studies soon (~10h) For applications AIDA-KIT and AIDA-KIT I expect about 3h of beam time So we have about 40h (of 160h total) remaining for further projects

A. Dierlamm Institut für Experimentelle Kernphysik AIDA Annual Meeting - WP Backup

A. Dierlamm Institut für Experimentelle Kernphysik AIDA Annual Meeting - WP The Karlsruhe Proton Cyclotron KAZ Run by private company ZAG We are customers and have to pay per beam time Proton energy at extraction: 25.3MeV Energy at samples: ~23MeV in first layer Typical proton current: 1.5µA Temperature in box: ~ -25°C Beam spot ~ 7mm (varying) Flux ~ 2.5e13 p/(s·cm²) FWHM~7mm Sample box on XY-stage with beam line Man placing LN 2 boxControl room

A. Dierlamm Institut für Experimentelle Kernphysik AIDA Annual Meeting - WP Scanning Procedure Samples are scanned in 1mm spaced rows Edge regions are inhomogeneous and a margin of ~1cm is used Proton fluence is calculated by: The proton current I P is always measured at the last beam stop At the nominal values of I P =1.5µA and v x =115mm/s we generate 1.5e13n eq /cm² per scan Autoradiographic image of a large Ni-foil scanned in the described procedure. The white area is a cut out for further dosimetry.

A. Dierlamm Institut für Experimentelle Kernphysik AIDA Annual Meeting - WP Energy at Target 25.3MeV is the energy in the beam line Protons have to pass several materials until they hit the samples SRIM gives us a proton energy entering the samples of about 23.8MeV and on average in the sample: 22.9MeV Samples covered by Nickel foils see lower energy ~22.8MeV SRIM