1 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Dishwasher Wash System Upgrade Benefits Sound Reduction Less Water Consumption.

Slides:



Advertisements
Similar presentations
GE Standard Dishwasher 2007 series
Advertisements

The Pay Me Game.
HVAC523 Heat Sources.
Kenmore Front Load Washer & Dryer
Chapter 9 Choosing Kitchen Appliances
New Type C & D Straight line wiper options.
GENESIS WASHER Patented Dual Drive Technology, when combined with the Shower Wash system, results in significantly higher washability than leading brands.
Mini Jet Sample Dyeing M/C Daelim Starlet Co., Ltd.
CAGE AND RACK WASHER LEADER is a professional manufacturer Backed up by 30 years experience in the Asia area of laboratory, pharmaceutical and medical.
Monthly Update: Training Center BSH Internal Communication Introducing the NEW 800 Series Bosch Dishwasher…. For any additional questions on this new dishwasher,
The DB In-Line Pumpout Unit Easy-to-use control panel with one switch to run the unit. 15 AMP reset fuse. 115 AC External water pump and tank drain have.
"AIR COOLER" Heat Exchanger
© LWTL Faculty Team Living with the Lab Pump Performance Testing.
Walter G Bischoff Brunswick station Duke Energy
Dakota Nickerson, Kyle Pflueger, Adam Leschber, Andrew Dahlke M.E. Undergrad 1.
1. Pump down the chamber from the atmosphere pressure 2. Using RHEED to obtain diffraction images 3. Open the RHEED chamber or venting from high vacuum.
Saving Energy and Money at Home and on the Road
By : Theresa & Sade..  Showers that go on too long.  Using a hose instead of a broom to sweep your garage/driveway.  Using washing machines & dishwashers.
1 Tankless Water Heaters – Deemed Savings Issues May 7, 2002.
DL – Liquid Filling System The DL – Liquid Filling System is just one example of the equipment we design and manufacture for specialty applications.
Hydronic Mechanical Controls
Mechanical for Oil Heat
Hydraulics For The Long Term
Pesticide and Fertilizer Bulk Storage. Buying in bulk.
Water Pumps.
Water Quality Testimonials: Veterans Home of California-Barstow Hobart Water-Softening System (WS-213) Franklin County Correctional Facility Hobart WS-C208.
How does Pollution Effect the Water We Drink? TEKS § (b)(6)(c) Anne M. Berry.
Deposition of Solder Paste into High Density Cavity Assemblies
ENERGY STAR ® SALES ASSOCIATE TRAINING Dishwashers (Updated: September 2010)
INSTALLING NAECA III PRODUCT IN CONFINED LOCATIONS Brought to you by: NAECA III.
Edison would be pleased. 2 / Edison secured a spot in history, igniting a company built on innovation and leadership 1879 – Incandescent Lamp 1949 – Jet.
By: Kristen McKnabb. Step 1: Aquarium and Aquarium materials Wash the aquarium gravel, rocks, and other decorations. Do not use soap or detergents they.
Eco-Winter Installation. – Step 1 – Mount Eco-bypass to water heater.
ME T HERMAL F LUID S YSTEM D ESIGNS Heat Exchanger Final Project.
1 Analysis of Cost and Savings Values for Revised Energy Star Dishwasher Specifications June 6, 2006.
Automotive Heating and Air Conditioning CHAPTER Automotive Heating and Air Conditioning, 7e James D. Halderman | Tom Birch SEVENTH EDITION Copyright ©
Presented by: Rick Kuemin, MSA Training Director
Motorcycle gas tank rust removal & sealing Notes: 1.These are suggested instructions 2.Only applicable to steel gas tanks 3.Sealer won’t work on plastic.
Monday – VSP Room weekly checks Visually Check: Hvac system for leaks & valve settings Fresh water system for leaks & valve settings VSP linkage Autopilot.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Foods & Nutrition Sanitation & Clean Up Procedures AKA = Dishwashing 101.
Gemma Jones. I am going to look at the positive and negative effects between manual hand washing dishes and dishwashing machines through;  Cost  Energy.
2K AIRMIX® PU2160 FLOWMAX® PU2160 Flowmax ® Technology for Total Reliability.
Ships Service Air System
XR621 Drive Hose Update Kit. Removal Turn off Battery dis Drain hydraulic tank Remove both rubber lines under chassis and discard. Remove and discard.
By Molly. Things that you will need  Fish tank  Grow bed tub  Water  Clay balls  Pipes  Oxygen pump  Water pump  Garden hose  Plants  Bucket.
The Cooling System (Reasons for)
Fluid Mechanics for Chemical Engineers Arif Hussain (Lecturer)
WASHING MACHINE Prepared by: DHAVAL MODI PANKAJ SAINANI
Imagination at work HE Top Load Competitive Comparison 2013.
Pump Performance Testing. Goal: Measure the pump curve(s) Head versus flow rate:Efficiency versus flow rate:
Vertical Pump Motor Manifold Upgrade. VPMM Replaces Existing Pumps, Motors, Relief Valves, Check Valves, Discharge Filters, Pump Running Pressure Gauges,
INSTALLATION MANUAL FATL Machine Installing: ACTIVITY CHECK POINT 1. Minimum two persons required for opening the Machine. 2. Cut the straps & tape. 3.
ETEC 4301 Design Lab Jacob Ison Solar Energy and The Family Farm: The Mid-Semester Edition!
Appliance Efficiency: Continuing Consumer Savings Jennifer Amann, Buildings Program Director 2014 Consumer Assembly: Energy Efficiency Panel.
Silver Bullet Dishwasher
Automotive Heating And Air Conditioning
Instant hot water. Long-term savings.
Thunderbird Water Pump Upgrade
How Do Hot Tubs Work?.
ENERGY CONSERVATION As the human population keeps increasing (it’s over six billion people right now), we keep requiring more and more energy. Using too.
Solving Rational Equations
Dishwasher frequently asked questions
Stainless Steel Water Well Casing.
Scotsman Ice Systems Essential Ice New Ice Maker Series
Ecodesign and Energy Labelling In Europe
Presentation transcript:

1 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Dishwasher Wash System Upgrade Benefits Sound Reduction Less Water Consumption Improved Drying Energy Savings New Components Control Motor Drain Pump Wash Arms Pump Adapter Drain Hose All stainless steel tubs 6000 series and up Includes Monogram

2 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Benefits Sound Reduction - An average sound reduction of 2db is achieved by moving less water through the wash system (15 gallons per minute versus the current 24 gallons per minute) and isolating the drain pump by placing an adapter between the sump and the pump. Less Water Consumption – The tub fills with an average of 1.3 gallons per fill versus the current 1.5 gallons. The water valve is energized for less time (60-62 seconds versus the current seconds). Savings per wash cycle is approximately 1.4 gallons on a 7 fill cycle. Improved Drying – The electronic control increases heater on-time during the final rinse on all models. PDW8600 and below models add 8 minutes to the heated dry cycle for a total of 38 minutes dry time. Energy Savings – Internal testing shows an energy savings, although the energy labels will not be changed at this time.

3 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE New Components Drain Pump Electronic Control Adapter Coupling Motor Wash Arms Drain Hose

4 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Adapter The adapter isolates the drain pump from the sump and contributes greatly to the reduction in sound levels.

5 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Adapter Components The adapter is available as a complete assembly or as individual parts.

6 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Adapter Coupling

7 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Adapter Coupling

8 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE

9 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Drain Pump Mounting

10 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE

11 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Drain Hose

12 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Two Down Jets 10 Jets on top of arm Jets randomly spaced both sides of arm All jets are oblong Jet diameters range from.160” to.240” Jet diameters ~.250” Current Design Upper Mid Lower All jets are circular 3 outside jet diameters =.190” 6 inside jet diameters =.130” 9 Jets on top of arm 4 jets lined up 1.25” apart Jet diameters ~.125” No Down Jets New Design Upper Mid Lower

13 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE

14 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Motor

15 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Impeller Current Impeller New Impeller Design

16 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE

17 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE 2 ¾” Minimum Water Level

18 GE CONFIDENTIAL AND PROPRIETARY INFORMATION - NOT FOR PUBLIC DISCLOSURE Minimum water level to edge of left side heater support