CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.

Slides:



Advertisements
Similar presentations
Cabling system components
Advertisements

Cabling UTP AND FIBER CABLING. Structured Cabling Infrastructure Mounted and permanent Allows patching Comfort that infrastructure is OK Components: Information.
Why to learn OSI reference Model? The answer is too simple that It tells us that how communication takes place between computers on internet but how??
+ Straight-Through Cable Construction Lab 4. + Data Transmission In data transmission system, the transmission medium is the physical path between transmitter.
Cabling Structured Cabling Standards
CHAPTER Practical Token Ring Implementation. Chapter Objectives Give an overview of the Token Ring LAN Describe the characteristics of the Token Ring.
Physical Transmission Media 8 5/9/ Modified by: Brierley.
DATA COMMUNICATION A presentation for grade 9 on networks and the technologies that create them.
Network Capacity Planning IACT 418 IACT 918 Corporate Network Planning.
Computer Networks Done By: Sulaiman Qeshta Ahmed Faris
111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.
1 Version 3.0 Module 3 Networking Media. 2 Version 3.0 Cable Specifications Cables have different specifications and expectations pertaining to performance:
Networking Jeopardy!. Topologies Transmission Media OSI/RMStandards Hardware Components
Designing and Implementing Cabling Infrastructure Dr. Saif al Zahir King Fahd University of Petroleum & Minerals Computer Engineering Department Dr. Saif.
Fiber Optic Cable Installation Indoors Last Update Copyright Kenneth M. Chipps Ph.D. 1.
Content :  Indoor fiber optic cables  The benefits of indoor Fiber Optic Cable  The features of indoor Fiber Optic Cable  Tight-Buffered Cable  Consists.
TYPES OF NETWORKS NETWORK CONFIGURATIONS /TOPOLOGIES TRANSMISSION MEDIA By B. Vialva.
Computer Communication & Networks
Many Roads To Home. LAN Roads UTP STP Coaxial Fiber Optics.
CSE 550 Computer Network Design Dr. Mohammed H. Sqalli COE, KFUPM Spring 2007 (Term 062)
Installation and testing
INSTALL THE TRANSMISSION LINE By Mohd Nasir bin Said.
Fiber Optics LINK LOSS BUDGET.
Cisco 1 - Networking Basics Perrine. J Page 19/3/2015 Chapter 3 Which of the following correctly describes the type of signal that the network media carries?
Networks and Telecommunications
NETWORK CABLING Chapter 2
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
20 LAN Hardware Overview Version A.01 H3065S Module 2 Slides.
Information Technology Lecture No 3 By: Khurram Shahid.
Local Area Network By Bhupendra Ratha, Lecturer
Component 9 – Networking and Health Information Exchange Unit 2-2 Network Media and Hardware Communication Devices This material was developed by Duke.
HORIZONTAL SUBSYSTEM. CABLING SYSTEM Horizontal Subsystem The Horizontal cabling subsystem is the part of the Signamax Cabling System that extends from.
1 Guide to Network Cabling Fundamentals Chapter 5.
SYSTEM ADMINISTRATION Chapter 4 Network Media, Connectors, and Their Characteristics.
COMPUTER NETWORKS A presentation for grade 8. In the world of computers, networking is the practice of linking two or more computing devices together.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
CABLING SYSTEM BACKBONE SUBSYSTEM.
ANSI/TIA-568-C Generic Telecommunications Cabling APPROVED: FEBRUARY 2, 2009 This template can be used as a starter file for presenting training.
UNIT -1. DATA COMMUNICATIONS The term telecommunication means communication at a distance. The word data refers to information presented in whatever form.
Networking and Health Information Exchange Unit 2b Network Media and Hardware Communication Devices Component 9/Unit 2b1 Health IT Workforce Curriculum.
BIX In-Building Cross Connect system BIX Installation Guide ELCM 254 Updated December 2013 gmail.com 1 Most of the images and some text for.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
Chapter 3 Data communication. What is data communication? Transmission of data from one place to another place is called data communication.
CABLING SYSTEM ADMINISTRATION. Administration Concept.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
COPPER AND FIBER REVIEW
BACKBONE SUBSYSTEM. CABLING SYSTEM Backbone Subsystem The Backbone cabling subsystem is based on cabling segments, which link such connection centers.
TELECOMMUNICATIONS SPACES
CABLING SYSTEM PROTECTION. Screening/Shielding  1 In the Signamax Cabling System for the efficient screening of the telecommunications systems, the screen.
CABLING SYSTEM CERTIFICATION TESTING. TWISTED-PAIR CABLING TESTING.
CABLING SYSTEM WARRANTY REGISTRATION. PURPOSE OF CABLING REGISTRATION.
Outside Plant Fiber Optics
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
Developing Cabling Module Situation at August 2006 Vello Vanem.
Chapter Seven Network Topology [tə'p ɒ ləd ʒɪ ]. In networking, the term “topology” refers to the layout of connected devices on a network. This article.
COMMUNICATION SYSTEMS IN BUILDINGS/CAMPUSES
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
INTRODUCTION TO NETWORK CABLING
S12700 CSS Card Clustering 1 Components and Tools 2 Installing Cards
BIX In-Building Cross Connect system
Guidelines for Fiber Optic Design and Installation
Computer Networking A computer network, often simply referred to as a network, is a collection of computers and devices connected by communications channels.
Computer Networking A computer network, often simply referred to as a network, is a collection of computers and devices connected by communications channels.
Computer Systems Department.  Introduction  Course Objectives  Grading Policy  Lab Policy  Structured Cabling.
Presentation transcript:

CABLING SYSTEM INSTALLATION

Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications cabling systems designed for the high-speed applications support There is a special system of requirements and conditions to the installation of the cabling systems to preserve the primary transmission characteristics of individual components within the links, channels, and systems Whereas the rules of installation are the methods and accuracy of the component connections and cable organization and routing, the cabling rules are an important factor of the system capacity, simplifying the operation of the installed cabling systems

Installation Quality Significant reduction of the signal distortion may be achieved by the observance of the following requirements: –Usage of special methods of the cable preparation –Termination of the transmission media at the connecting hardware according to the manufacturer’s instructions –Ordered arrangement of the cable bundles –Correct spatial orientation of the connecting hardware –Observance of the installation rules and manufacturer’s requirements to the installation of the telecommunications connecting hardware.

CABLE INSTALLATION

Cable Installation  6 Cable ties applied to form cable bundles shall be loose enough to allow the cable tie to slide around and along the cable bundle. The cable ties shall not be tighten so snugly as to deform the cable sheath

Minimum Bend Radius The small bend radii are to be maintained for the twisted-pair cable because of the deformation and inconsistencies of the transmission media inside of the cable occurring at the pair kinks This causes a serious deterioration of such parameter as NEXT Any attempts of bend straightening may be ineffective for the pair shape restoration and may have even worse effect

Minimum Bend Radius In case of the optical fiber cables, if their bend radius is under permissible value, it may increase the losses incurred owing to the macro- and microbends and even the fiber fractures

Minimum Bend Radius Illustration of the “minimum permissible cable bend radius” notion

Minimum Bend Radius  10 The minimum Horizontal and Backbone subsystem cable bend radii shall be: Twisted pair (4 pairs): 4 times the cable outside diameter – during installation 4 times the cable outside diameter – after installation Twisted pair (multipair): 15 times the cable outside diameter – during installation 10 times the cable outside diameter – after installation continued on next slide

Minimum Bend Radius  10 Optical fiber: 50 mm (2 in) for 2- and 4-fiber inside plant optical fiber cable, during installation 25 mm (1 in) for 2- and 4-fiber inside plant optical fiber cable, after installation 20 times the cable outside diameter for inside and outside plant optical fiber cable with more than 4 fibers, during installation 10 times the cable outside diameter for inside and outside plant optical fiber cable with more than 4 fibers, after installation continued on next slide

Minimum Bend Radius  10 If the manufacturer’s requirements to the minimum bend radius of the certain cable are stricter than those specified above, the manufacturer’s requirements shall be observed

Minimum Bend Radius  1 The minimum recommended bend radius for the equipment and patch cables (cords) in service should be: –4-pair unscreened and screened twisted-pair cords – 4 outside cable diameters –optical fiber cords – 25 mm (1 in) To observe these requirements it is recommended to use specially designed means and devices

Maximum Pulling Tension On the cable installation and in some cases in their service (vertical segments) they are affected by the tensile load causing the pair deformation in the twisted-pair cables and mechanical damage of fibers in the optical fiber cables Therefore one of the basic installation requirements together with the bend radius is observance of the maximum permissible tensile load of the cables

Maximum Pulling Tension  11 The tensile load of the cables within the Horizontal and Backbone subsystems during installation and in service shall not exceed: –4-pair unscreened and screened twisted-pair cables – 110 N (25 lbf) –multipair twisted-pair cables – manufacturer’s specifications continued on next slide

Maximum Pulling Tension  11 –2- and 4-fiber inside plant optical fiber cables – 220 N (50 lbf) –inside plant optical fiber cables with more than 4 fibers – the manufacturer’s specifications –inside and outside plant optical fiber cables with up to 12 fibers – 1,335 N (300 lbf) –inside and outside plant optical fiber cables with more than 12 fibers – 2,670 N (600 lbf) –outside plant optical fiber cables – 2,670 N (600 lbf) continued on next slide

Maximum Pulling Tension  11 –drop cable installed by pulling – 1,335 N (300 lbf) –directly buried, trenched or blown into ducts cables – 440 N (100 lbf) If the manufacturer’s requirements to the maximum tensile load of the certain cable are stricter than those specified above, the manufacturer’s requirements shall be observed

Media Termination  12 To maintain the cable geometry, the cable sheath shall be removed only as much as required to terminate the cable pairs on the connecting hardware. The connecting hardware manufacturer’s instructions for cable sheath strip-back shall be observed

Media Termination  13 When terminating cable on connecting hardware, the cable pair twists shall be maintained as close as possible to the termination point. The distance from the termination point to the nearest pair lay node may not exceed: 13 mm (1/2 in) – category 5e, 6, and 6a cables 75 mm (3 in) – category 3 cables

Media Termination