Interlock System Equipments for Conventional Magnets PP-100901-a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments.

Slides:



Advertisements
Similar presentations
Safety for electronic systems High-frequency Filtering of DC Power Lines Technical, constructional and practical issues with filtering on dc power lines.
Advertisements

Electrical Installation-Module 3
André Augustinus 16 June 2003 DCS Workshop Safety.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
MICROCONTROLLERS MODULE 2 Programming, Controlling and Monitoring.
Booster Main Bending Magnet Test in SM18. Why The energy upgrade of the PS Booster main bending magnet requires endurance tests at high current (≈12 kA)
Oct. 10th 2006NSLS II Accelerator System Advisory Meeting SR-PS 1 NSLS II Accelerator System Advisory Committee Meeting October 10 – NSLS II Storage.
What is a circuit? A set of connected electrical components that provide one or more complete paths for the movement of charges. A set of connected electrical.
Slide 1UCSB CMS Weekly Status MeetingCMS 4-Hybrid Test System Sam Burke EE UCSB 4-Hybrid Thermal Test System Status 30 June Sam Burke UCSB HEP Group.
Status of the LHC Project L.Evans - C.Wyss Riunione CSN1 INFN Napoli, 21 Settembre 2005.
Overview of Phobos Magnet Designed by Harald Enge Built by Danfysik Technical summary: –“Double dipole” design –15.5 cm air gap –Max. 2 Tesla field –378.
Electrical Installation CM39 Andy Gallagher & Ian Mullacrane.
Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
HL-LHC Standards and Best Practices Workshop (11-13 June 2014)
Electrical Electricity Fuses Relays Solenoids Electrical Testing
Electrical Components.  This supplies all the power to the robot. It is a single 12 V battery. They are sealed to prevent battery acid from leaking.
2 Instructor Training MPTT Flow Loop System VLP-TRN-MPTT.
TE-MPE-TM 09/08/2012, TE-MPE-MS section WIC: Overview of on-going projects + Outlook to LS1 activities: - Short introduction to WIC systems - Booster renovation.
Table of Contents Electricity.
Circuits Series and Parallel. Series and Parallel Circuits  Circuits usually include three components. One is a source of voltage difference that can.
ITER – Interlocks Luis Fernandez December 2014 Central Interlock System CIS v0.
1 Reading Electrical & Refrigerant Drawings. 2 General An electrical drawing shows the components of the circuit as simplified standard symbols, and the.
2nd ATF2 meetingRole Sharing between KEK and SLAC M.Kumada Role Sharing between KEK and SLAC 1.Performance of Demonstration power supply of KEK 2.Role.
Proton Plan Director's Review 8/15/06 – Booster Corrector UpgradeDrennan1 Proton Plan Booster Corrector Upgrade Directors Review August 2006 Presenter:
Beam Interlock System PR b-CTM, October 7th, 2010 Cesar Torcato de Matos.
HINS 6-Cavity Test 3 Month Plan Jan 12, Current Schedule 2-3 day shutdown scheduled to start Jan 18 (Wednesday) to upgrade BPM system and reinstall.
FAIR PROJECT COST BOOK. FAIR cost 1.2 mld euro 1. Civil construction and infrastructure 322Meuro 2. Accelerator systems 592 Meuro 3. Experimental facilities.
The 3 parts of an electronic system are :
Home Electrical Systems. Behavior Objectives  Define the basics of Electrical Systems  Explain the basic principles of Electricity.  Describe the different.
Installation issues - update, July 2006A.Fabich1 MERIT installation: Update July 2006 A.Fabich CERN AB-ATB July 2006.
Chiller control system Lukasz Zwalinski – PH/DT.
Chiller control system Specification meeting Lukasz Zwalinski – PH/DT.
Accelerator Design: the nuts and bolts…and gaskets and resistors Elvin Harms Beams Division/Fermilab
What is a circuit? A set of connected electrical components that provide one or more complete paths for the movement of charges. A set of connected electrical.
1 BROOKHAVEN SCIENCE ASSOCIATES Power Supply Status George Ganetis Power Supply Status ASAC Review October 22-23, 2009.
Electric Energy Notes.
Power Converters and DC cablesSlide 1/.. LHC - HC review Hugues THIESEN – AB/PO Thursday, 12 May 2005 Water cooled cables warm bus bars power converter.
SAFETY DURING HARDWARE COMMISSIONING, 18 October 2007, D. Bozzini, AT/MEL-EM 1 Safety during Hardware Commissioning Davide Bozzini on behalf of the ELQA.
18240 Element two - Components INPUTS OUTPUTS PURPOSE TYPICAL USE.
SUBMMITED BY : MOUTRISHNA GAYAN CLASS : VII ROLL. no : 9.
Machine Protection Review, R. Denz, 11-APR Introduction to Magnet Powering and Protection R. Denz, AT-MEL-PM.
Philip Schwarz TE-MSC-MNC 1 Engineering Specifications for ELENA ring and TL magnets Philip Schwarz on behalf of WP 2.2 ELENA IIC meeting 5 th December.
E.Sbrissa EP/TA3 - IC ATLAS EDR_MAG Magnet Project Fault analysis, QA & Failure rate.
Amateur Radio Licensure Week 5: Advanced Electronics Seth Price, N3MRA New Mexico Institute of Mining and Technology February 28, 2016.
Start of Sales MSI-XXXB Safety Relays Plugable screw or spring-cage terminal blocks.
The power supply for magnetic elements at CR D.Senkov IWAPT 2015, BINP, Novosibirsk The power supply for magnetic elements at CR D. Senkov/
1 T. Mohite and H. Welker LINAC and Operation/ Electric Power Systems GSI Darmstadt Power Converters for the Magnets of Collector Ring in FAIR
TEST FACILITY STATUS FOR TESTING CERN Marta Bajko WP10. EUCARD 2 Task 4 - HTS Magnet Tests, June 2015.
Programme for the Physics Start-up Stable and radioactive beams Jose Alberto Rodriguez, BE-OP-PSB (167538)
Electric Circuits Chapter 14, Section 4. Circuits consist of an energy source, a load, wires, and in some cases, a switch.
Wireless Electrical Device Switching using RF Technology By ByM.SANDEEP.
Hardware Commissioning Review, R. Denz, 12-May Superconducting circuits: what remains to be done during hardware commissioning R. Denz AT-MEL-PM.
High energy beam transport.
Considerations from machine protection and the ELQA teams
Testing of SC Magnets Status - November 2010
Magnet Power Supply System Overview
Accelerator layout > 1000 components (almost 300 magnets and power converters, 153 beam diagnostic devices, about 400m of vacuum pipes, a not neglectable.
INDUCTION MOTOR PROTECTION FOR SINGLE PHASING, OVERVOLTAGE AND OVER TEMPERATURE Submitted by:
Powering the LHC Magnets
Notes 5 ECE 3318 Applied Electricity and Magnetism Fall 2017
Detailed global view on protection and detection of the circuits
TEST PLANS for HL LHC IT STRING
Electric Energy Notes.
Yannick Dietrich François Bouvet SOLEIL
III. Correction Dipoles MDG Accessories for all Magnets V. Summary
Basic Electrical Circuits
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Presentation transcript:

Interlock System Equipments for Conventional Magnets PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October

Content Purposes, components Magnets type Magnet Interlock System layout Interlock Box The Testing Box Particularities of the water flow monitor PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October

Purposes Magnets protection against overheating Switch off the Power Converter Provide the magnet status to the Beam Interlock System (BIS) Display the state of the power converter (operational or not) PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October

Components Thermoswitch for thermal protection of the coils Water flow monitor for the water flow control Box for thermoswitches interconnection Indicator to display the power converter status Connection for the communication with Beam Interlock System Connection for the tests during commissioning and maintenance PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October

Magnets type PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October Item 1 cooling circuit device 2 cooling circuits device 3 cooling circuits device 4 cooling circuits device LINAC&LEBT MBHA (Spectrometer)5 MBSA (Switching Dipole)3 MCXA (Corrector hor+vert)19 MQZA (Quadrupole)22 MSOA (Solenoid)6 MEBT MBHB (Dipole Magnet)4 MCXB (Corrector hor+vert)9 MQZB (Quadrupole)11 SYNCHROTRON MBHC/MBHD (Dipole Magnet)20 MCHC (Corrector horizontal)11 MCVC (Corrector vertical )9 MINC (Betatron core)1 MQAC (Quad air cored)1 MQZC/MQSC (Quadrupole/ skwed Quad) 27 MXZC (Sextupole)6 HEBT& Treatmement Rooms MBHE (Dipole Magnet)13 MBVF (Dipole 90 deg)1 MCXE (Corrector hor/vert)20/20 MQZE (Quadrupole)81 MSHE (Scanning dipole hori)6 MSVE (Scanning dipole vert)6 Estimate of magnets for the gantry10 Spare box9 TOTAL : air cooling magnets

Magnet Interlock System PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October Frontend Conventional Magnets Thermoswitch interlock Beam Interlock System (BIS) Supervisor (SCADA) Frontend Conventional Magnets Water flow interlock PC Status Thermoswitch interlock Water flow interlock PC Status ControlsMagnets

Magnet Interlock System PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October orange LED indicators (one redundant) for magnet status (ON= Power supply Operational) 1 bridge connector (19 pins) installed during operation 1 connector (8 pins) for Beam Interlock System communication 8 terminals for thermoswitches connection 2 thermoswitches (one redundant) connected in series for each cooling circuit 1 water flow switch MAGNET INTERLOCK BOX

Magnet Interlock System PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October The “last” thermoswitch wire shall be connected to the second terminal => close the interlock switch loop MAGNET INTERLOCK BOX

Magnet Interlock System PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October

Interlock Box PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October Purpose: - Junction box for the thermoswitches - PC indicator - Connection to the BIS - Connection for the tests Characteristics: -Standard for all magnets -Radiation resistance - Redundant indicators - No disconnection required from BIS during maintenance - the 8 pins connector respects the requirements for the BIS (ES a-MMA) Quantity: (including 9 spares) INTERLOCK BOX The LEDs do not specify if the magnet is in a safety state for intervention on it

Interlock Box PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October

The testing box Purpose: Interlock verification during the commissioning Diagnostic during operation Allows to test the interlock boxes and BIS connection Characteristics: Standard for all magnets type No radiation resistance required No electrical network connection required PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October

The testing box PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October List of available tests: (1) self-test (box battery) (2) output to BIS (3) input from BIS (4) thermoswitches (5) LED indicators on the interlock box (6) bridges in the 19 pins connectors TESTING BOX

The testing box PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October

Water Flow monitors PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October Example of water distribution system (UKGM Marburg) Water flow monitor Particularities: -One for each water cooled magnet -No redundant system -Installed next to the water manifolds on the water outlet -Cable directly connected to the Beam Interlock System (with respect to the cable and color code defined in ES a-MMA)

Water Flow monitors Connections Quantity 225 (including 10 spares) PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October

Conclusion Standardization of the interlock box Possibilities to test the Magnet Interlock System Adaptations for the water flow interlock PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October

Thank you for your attention Questions? PP a-ABT_interlock conv mag.ppt October 22, 2015 Anthony Beaumont Interlock System Equipments for Conventional Magnets MACS week October