Dupline Specialist Seminar 2005 1Jens Neigaard DuplineSafe.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

Khaled Mostafa, ABB Electrical Industries, Nov. 2012
Emergency Transfer Controls
MUR-System Next We want with this PowerPoint show how easy it is to install the MUR-Systems hardware. You can try the full version of the software from.
Basic Jens Neigaard.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
HYDRAULICS & PNEUMATICS
Asahi/America New Positioners: Pneumatic Actuators-Westlock P-10,K-10 Electric Actuators-Peaktronics-DHC- 100 Competitor Comparison Positioners.
Redundant control system (RCS)
1 Hardy Process Solutions – New Product Introduction HI6600 Series – Modular Sensor System Hardy delivers productivity solutions to manufacturers and processors.
Rexroth IndraDrive Integrated Safety Technology
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
SYMAP-BC SYMAP-BC.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
EUT 1040 Lecture 10: Programmable Logic Controllers.
1 The University of Jordan Mechatronics Engineering Department PLC: Programmable Logical Controller.
Active Stations PC PLC PROFIBUS Passive Stations (Field Devices)
New Automation Technology
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
One solution, many application Integrated Electronic Solution PowerSupply Flex.
Timers - PAGE 1/20 - Timer Products. Timers - PAGE 2/20 - Multitechnology PROCESSING ACTUATING SENSING COMMUNICATING PROCESSING SOLUTIONS.
AUTOMATION & PRODUCTION TECHNOLOGY. PROJECTS Students learned about group dynamics and the Engineering Design Process How can we build the tallest structure.
Advantys® STB High Density Discrete I/O Modules. AGP - English 2 Advantys® STB Advantys STB delivers customer value in distributed I/O Smart Built-in.
Distributed Control Systems Emad Ali Chemical Engineering Department King SAUD University.
PLC: Programmable Logical Controller
TM SM Maximum Value for OEMs SM NXIO Platform from “OEMax NXIO Introduction CN rev4.ppt” Thomas Sugimoto Strategic Marketing Manager Thomas Sugimoto Strategic.
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
PROGRAMMABLE LOGIC CONTROLLER (PLC) AND AUTOMATION
SCADA and Telemetry Presented By:.
Motor Control Center MNS iS with Condition Monitoring
PLC introduction1 Discrete Event Control Concept Representation DEC controller design DEC controller implementation.
PLC: Programmable Logical Controller
Dupline Specialist Seminar Jens Neigaard DuplineSafe.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
Module 1: Introduction to PLC
Programmable Logic Controller (PLC)
Turck Fieldbus technology. A010 2 Components for: PROFIBUS-DP DeviceNet™ Interbus AS-Interface® CAN Open Ethernet -Modbus TCP -Ethernet/IP -ProfiNet Product.
Welcome to the World of Programmable Logic Controllers
Copyright © 2002 Delmar Thomson Learning Chapter 1 Welcome to the World of Programmable Logic Controllers.
 AUTOMATION  PLC  SCADA  INSTRUMENTATION  DRIVES & MOTORS.
Lexium SD2 and Lexium SD3 Stepper Drives and Motors -Lexium SD2 - two-phase range up to 9.2 Nm -Lexium SD3 - three-phase range up to 19.7 Nm.
Dupline Elevator Bus Jens Neigaard.
VARAN Bus Presentation 1 / 27 The VARAN BUS.
EEE440 Computer Architecture
Internet 0 for Industrial Applications Fred Cohn 13-Dec-07.
1 Internal | ST/PRM2-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Dupline Hi-Line Irrigation Control Jens Neigaard1.
Water. What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured application software.
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
EPack relaunch. Schneider Electric 2 -Industrial – Eurotherm – 16/12/2015 ●1. Reduce your equipment costs.
New product introduction:
PROGRAMMABLE LOGIC CONTROLLER
SEMINAR ON P.L.C. SUBMITTED BY HRIDAY MUKHERJEE AMIT DEBNATH SOMNATH SHIL
ABOUT INSTRUMENTATION Instrumentation is used in almost every industrial process and system, where consistent and reliable operations are required. Instrumentation.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
CML 700i measuring light curtains Integrated interfaces and control unit for even simpler operation Leuze electronic | CML 700i product launch | Status:
Seminar on "PLC” (Programmable Logic Controller)
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
SOLID STATE RELAYS are used to produce reliable signal and to avoid expensive relay replacement.
C1300 advanced circular chart recorder
UNICOS: UNified Industrial COntrol System CPC (Continuous Process Control) Basic course SESSION 3: PLC basics UCPC 6 UNICOS-Continuous Process Control.
ACOE347 – Data Acquisition and Automation Systems
Presentation transcript:

Dupline Specialist Seminar Jens Neigaard DuplineSafe

Dupline Specialist Seminar Jens Neigaard To seek approval for Dupline as a Safety Bus according to: EN61508 (SIL 3) Functional safety of electronic systems EN61508 (SIL 3) Functional safety of electronic systems EN954-1 (Cat 4) Safety related parts of control systems EN954-1 (Cat 4) Safety related parts of control systems EN81–1 (Cat 4) Elevator safety norm EN81–1 (Cat 4) Elevator safety norm DuplineSafe Idea

Dupline Specialist Seminar Jens Neigaard We have existing customers demanding it We have existing customers demanding it We have new potential customers demanding it We have new potential customers demanding it The approvals will open new markets for Dupline The approvals will open new markets for Dupline The general image of Dupline will be improved The general image of Dupline will be improved Synergy with the Safety Product Group Synergy with the Safety Product Group The trend in the Fieldbus market is going in this direction- and we must continue to develop our technology to keep pace The trend in the Fieldbus market is going in this direction- and we must continue to develop our technology to keep pace Why do we need these approvals ?

Dupline Specialist Seminar Jens Neigaard Dupline has some unique features which make the system very suitable for certain safety applications: Dupline can handle long distances Dupline can handle long distances Dupline is noise immune and reliable Dupline is noise immune and reliable Dupline is simple Dupline is simple Dupline modules can be powered from the bus Dupline modules can be powered from the bus Dupline input module can be ATEX approved Dupline input module can be ATEX approved How can we compete with open Safety Buses like ProfiSafe, SafetyBus and ASI-Safety ?

Dupline Specialist Seminar Jens Neigaard Traditional safety circuit with series wired NC Contacts Problems: Shorted contacts create an undetected loss of safety function No diagnostics Resistance in contacts becomes a problem over time 0 VDC 24 VDC 0 VDC 24 VDC Contactor Safety Relay

Dupline Specialist Seminar Jens Neigaard 0 VDC 24 VDC 0 VDC 24 VDC Contactor Safety Relay Problems: Wiring cost Limited number of inputs Lack of flexibility Traditional parallel wired safety circuit

Dupline Specialist Seminar Jens Neigaard The DuplineSafe Solution Standard Dupline Channel Generator Standard Dupline Channel Generator Buspowered Safety Input Modules Buspowered Safety Input Modules Configurable Safety Relay Output module Configurable Safety Relay Output module Diagnostic information via PLC, PC or Diagnostic information via PLC, PC or Text Display Text Display Up to 63 safety signals on one Dupline bus Up to 63 safety signals on one Dupline bus Safety Output module Contactor Tx Safety Input modules Contactor PLC/ PC/ Text Display Gateway Profibus-DP or Modbus Channel Generator 0 VDC 24 VDC 0 VDC 24 VDC

Dupline Specialist Seminar Jens Neigaard DuplineSafe vs. series wired safety circuit The risk of a dangerous short circuit is much lower because all short circuits on the bus are either detected or have no impact on safety function The risk of a dangerous short circuit is much lower because all short circuits on the bus are either detected or have no impact on safety function Only risk is input leads, but these are very short due to the vicinity of the input module Only risk is input leads, but these are very short due to the vicinity of the input module Precise diagnostics which can be read from a PLC, PC or Text Display Precise diagnostics which can be read from a PLC, PC or Text Display No problems with contact resistance due to short input leads No problems with contact resistance due to short input leads Safety Output module Contactor Tx Safety Input modules Contactor PLC/ PC/ Text Display Gateway Profibus-DP or Modbus Channel Generator 0 VDC 24 VDC 0 VDC 24 VDC

Dupline Specialist Seminar Jens Neigaard DuplineSafe vs. Parallel wired safety circuit Safety Output module Contactor Tx Safety Input modules Contactor PLC/ PC/ Text Display Gateway Profibus-DP or Modbus Channel Generator 0 VDC 24 VDC 0 VDC 24 VDC Reduced wiring cost Reduced wiring cost Higher number of inputs possible Higher number of inputs possible (up to 63 input modules) (up to 63 input modules) Higher flexibility for enhancement of a system Higher flexibility for enhancement of a system

Dupline Specialist Seminar Jens Neigaard Communication Concept The synchronization channel is toggling every Dupline cycle (controlled by safety output module) The status of each input is transmitted is on 2 different Dupline channels The transmission is dynamic with the bits toggling every Dupline cycle When the input contact is closed, channel 1 follows the sync channel, channel 2 is reverse. When the input contact is open it is the opposite

Dupline Specialist Seminar Jens Neigaard Communication Concept

Dupline Specialist Seminar Jens Neigaard The Safety Modules - Can operate on existing Dupline system - Can be used together with standard Dupline modules Combined Solutions

Dupline Specialist Seminar Jens Neigaard The DuplineSafe Approval Approval according to: IEC SIL3 EN954-1 Cat. 4 Pending: EN81-1 Approved Products: Safety Input Module (GS ) Safety Relay Output module (GS )

Dupline Specialist Seminar Jens Neigaard The Products GS

Dupline Specialist Seminar Jens Neigaard The Products GS

Dupline Specialist Seminar Jens Neigaard The Products GS

Dupline Specialist Seminar Jens Neigaard The Products GS

Dupline Specialist Seminar Jens Neigaard The Products GSTI50

Dupline Specialist Seminar Jens Neigaard The Products GTD50

Dupline Specialist Seminar Jens Neigaard Safety rules / info in GS Datasheet

Dupline Specialist Seminar Jens Neigaard Safety rules / info in GS Datasheet

Dupline Specialist Seminar Jens Neigaard Safety rules / info in GS Datasheet

Dupline Specialist Seminar Jens Neigaard Safety info / rules in GS Datasheet

Dupline Specialist Seminar Jens Neigaard Safety data for approved products

Dupline Specialist Seminar Jens Neigaard Application example

Dupline Specialist Seminar Jens Neigaard Advantages

Dupline Specialist Seminar Jens Neigaard Advantages

Dupline Specialist Seminar Jens Neigaard Target Applications 0 VDC 24 VDC 0 VDC 24 VDC Contactor Safety Relay REPLACEMENT OF SERIES WIRED EMERGENCY STOP SYSTEMS : Much safer Diagnostics reduce downtime Several safety relays at different positions can react on the same safety switch

Dupline Specialist Seminar Jens Neigaard Target Applications Application requirements to our advantage Long distances Widespread safety switches No local power supply available at safety switches High reliability / noise immunity demanded Simplicity in design, installation and commissioning demanded Frequent system changes Application requirements to our disadvantage Ultra-fast reaction-time needed (not needed for buttons / pull-wire) Advanced safety functions needed (e.g. Safety PLC with programmable logic functions) Open system specified

Dupline Specialist Seminar Jens Neigaard Target Applications Application examples Long bulk material conveyors Tunnels Mines Stone Mills Power Plants Cement Factories Conveyors used in sorting systems Airports Postal systems Automated Logistics Systems Wood Works Cranes (sliding contacts) Automatic door systems (e.g. big stock facility) Elevators (when EN81-1 approval is ready) Chemical plants (especially when ATEX approval is ready)

Dupline Specialist Seminar Jens Neigaard Competitors Safetybus-P (Pilz) ProfiSafe (Siemens) ASI-Safety at work (Siemens, Schneider, Turck..) Interbus Safety (Phoenix) Devicenet Safety (Rockwell) SafeEthernet (HIMA)

Dupline Specialist Seminar Jens Neigaard Sales Tools / Promotion DuplineSafe Flyer

Dupline Specialist Seminar Jens Neigaard Sales Tools / Promotion Exhibition Panels

Dupline Specialist Seminar Jens Neigaard Sales Tools / Promotion Demo Suitcase

Dupline Specialist Seminar Jens Neigaard Sales Tools / Promotion Application Notes

Dupline Specialist Seminar Jens Neigaard Sales Tools / Promotion Dupline.com

Dupline Specialist Seminar Jens Neigaard Sales Tools / Promotion Advertisement / Poster

Dupline Specialist Seminar Jens Neigaard Future Developments EN81-1 approval (open PCB version) Visit elevator companies to discuss Applicability of concept Reaction time Number of I/O’s Interfacing Mechanical solution Payback issues Pricing Determine target customers / elevator types Expected time of approval: Q We could be the first EN81-1 approved Safety Bus

Dupline Specialist Seminar Jens Neigaard Master Module PLC Power Supply 1 24 VDC RS232/485 Safety Tx I/O-module Contactor for Power/ Motor 0 VDC 24 VDC Safety Monitor Push Buttons Lamps 1’st floor 2’nd floor Push Buttons Lamps DuplineSafe for Elevators – combined solution

Dupline Specialist Seminar Jens Neigaard Future Developments ATEX approval We could be the first on the market with an IEC approved Safetybus with Bus-powered IS input modules ATEX approved Channel Generator needed ATEX approval not needed for Output Module A close cooperation with AUSTDAC is needed in this project Expected time of approval: Q2/(Q3) 2006

Dupline Specialist Seminar Jens Neigaard Future Developments General improvements (phase 2) Option to program Release-delay in the Safety Output module Option to make a ”safety-only” system where un-used channels are monitored for activity Approval from TUV that DuplineSafe Repeater can be used Mounting bracket for the Safety Input Module Improved quality of programming adaptor connectors Expected time of availability: Q2 2006

Dupline Specialist Seminar Jens Neigaard Future Developments ProfiSafe Gateway ? Two-input DIN-rail module ?