The Importance of Distribution. Manifold Position And Vapor Trail.

Slides:



Advertisements
Similar presentations
TRENDSETTING MINDSETS ARISE IN SMART HEADS
Advertisements

Power Plant Engineering
HVAC 11a CNST 305 Environmental Systems 1 Dr. Berryman
Antero Punttila Analyzing most typical energy saving measures Energy Efficiency of Steam and Condensate Systems Antero Punttila, Motiva Oy.
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
Different methods of energy conservation
Energy Efficient Steam Systems
HumidiClean. New After 400 Hours After 800 Hours Ionic Bed.
1 Optimizing the Efficiency of the NCAR-Wyoming Supercomputing Center Ademola Olarinde Team Member: Theophile Nsengimana Mentor: Aaron Andersen August.
Calculating Efficiency Opportunities in Insulation Workgroup Meeting May 2014 Charlie Schreier, PE Engineer.
STEAM TRAPS.
Introduction Enthalpy Wheel
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY. “Air conditioning is the control of the humidity of air by either increasing or decreasing its moisture content.
Energy Efficient Steam Systems. Steam Systems Steam systems most widely used type of process heating Advantages of steam: –Heat carrying capacity of steam.
Modine 93% Separated Combustion Condensing Unit Modine’s Breakthrough Solution to Commercial Heating.
Driving Toward Energy Efficiency Emerson Process Management Novaspect. Inc. June 22 / 23, 2010 Steam.
Presented by: Terry Stohs Viessmann Manufacturing Company Inc.
Steam Generation Efficiency
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
©2005 Armstrong International, Inc. Open and Closed Systems.
HVACR416 - Design Humidification. Relative Humidity 1.Air in the home is artificially dried out when it is heated. 2.Because warm air expands, this expansion.
MOCS Mike Hobbs Mike Steele Mike McGann Scott Daniels James Linder PBL-7-98 Chemical Heat Pump.
CWS 70ºF CWR 80ºF Cooling Tower Humid air Out with heat Dry air In Central Energy Plant A/C Unit Work EMCS 404 Chilled Water Supply 40ºF Chilled Water.
POWER PLANT.
STEAM CONDENSERS.
STEAM HEATING.
Hydronic Mechanical Controls
©2005 Armstrong International, Inc. Proper Piping Practices (Pumps)
Objective Learn about Cooling and Cooling systems Define heat pump Learn about energy storage systems.
Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam at the desired temperature and pressure.
Heat Exchanger Stall.
Plan 2 – Dead-end Seal Chamber Optional Jacket
Dealing with Impurities in Processes and Process Simulators ChEN 5253 Design II Terry A. Ring There is not chapter in the book on this subject.
BASIC MECHANICAL ENGINEERING. REFRIGERATION AND AIR CONDITIONING.
Partial Evaporation Example 1/31/2007. Shell and Tube Heat Exchanger.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Heating Systems.
NOVO ETS IMPROVING YOUR ORGANIZATIONS’ ENVIRONMENTAL, HEALTH AND SAFETY PERFORMANCE ENERGY MANAGEMENT IN THE CONTEXT OF GREEN PRODUCTIVITY.
Presentation Dungrani rakesh v. Div : a Branch : mechenical Sem : 1 st.
The key to comfort and reduced fuel use for all heating systems.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Condensing Hydronic Heat Exchangers Make-Up Air Units Meets.
Hilario J. Negrón (787) ext 3223 (787) Measuring Operational Efficiency.
Tank Heating by Various Methods for Metal Finishing and Other Process Heating Applications OVERVIEW 1.
ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 11: STEAM PIPING SYSTEM (1)
I Need A Space Heating System Let’s Look At A Central Steam Plant Option.
Parameter's Approach to Relative Humidity Control August 25, 2011 by Clay Hile.
Prepared by : Nishant .A. Raval
4.0 Equipment Installation Aspects (Section 4.5 On-Rate for Fuel-Fired Equipment)
Boiler Safety Valve Regulations
ME444 ENGINEERING PIPING SYSTEM DESIGN
Kraft Summer Intern 2015 Jacob Herbstritt.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
Maturing and cold smoking
Condensate Management
PRIEN / PIAA Meeting April 30, 2009 Pfizer Caguas
ZONING (see section 17.0) Zoning alternatives Constant Volume (CV)
Stainless Steel Water Well Casing.
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY
Power Plant Engineering. Boilers Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam.
The key to comfort and reduced fuel use for all heating and cooling
Lecture Objectives Finish the cooling load example
First Exam is on March 21 Examples are posted on the course website !
Tracer Applications.
HUMIDIFIERS.
Boiler Room LOG Sheets: Interpreting the Records
Energy Management Introduction Rantharu Attanayake BSc. (Eng), MSc, MBA EE – Energy Management Mobile :
Presentation transcript:

The Importance of Distribution

Manifold Position And Vapor Trail

Duct Air Temp And Vapor Trail

Air Flow Velocity And Vapor Trail

Humidification And Temperature Controls

Multiple Manifolds In Duct

Multiple Manifolds And Vapor Trail

Recommended Number and Spacing of Manifolds for Various Duct Heights

Design Guidelines: Boiler & Humidifier Combinations Boiler Gross Output Capacity Should be at Least 1.5 Times Total Humidification Load Water Softeners Should Be Used On Boiler Feed Water Condensate Return System Is Not Necessary (Unless Required by Circumstances)

Design Guidelines: Boiler & Humidifier Combinations Boiler Pressure Should Be 15 psig (1 bar) Or Less Automatic Blow-Down System Is Desirable Steam Supply Piping Should Be Insulated No Limit To Size Or Number Of Humidifiers From One Boiler

Steam Humidifier - Performance Vapor Quality Excellent –Steam Molecules are.0006 Microns –Humidifier Tests Indicate No Particles Less Than 3 Microns Turn Down - Up To 123:1 For Single Humidifier Response Time - Excellent

Steam Humidifier - Costs Equipment –100 LB/hr (45 kg/hr) = $2,200 –1000 LB/hr (450 kg/hr) = $5,500 Installation –Depends on Application Energy –100 LB/hr (45 kg/hr) = $0.50/hr Maintenance –1 Hour Per Unit Per Year

Steam Supply Options No Volatile Chemical Treatment Do Not Return Condensate –Not Much Condensate With Humidification Stainless Steel Return Piping Replace Return Lines When Corroded

Dedicated Steam System Separate Boiler(s) For Direct Steam Humidifiers –Not Cost Effective At 100 LB/hr (45 kg/hr) –But Can be At 500 LB/hr (225 kg/hr) or More –Plus Benefits of Direct Steam Injection