July 26, 2014 Refrigeration Subcommittee Proposed Revision of Refrigeration Provisional Data Requirements.

Slides:



Advertisements
Similar presentations
Add Doors to Open Multi-deck Cases: Provisional UES RTF Meeting August 30,
Advertisements

UPDATE ON GROCERSMART 4.0 RESEARCH PLAN Regional Technical Forum May 3, 2011.
GrocerSmart 4.0 redesign -request for rtf input- February 25, 2010.
BPA Guidelines for Measurement & Verification of Energy Efficiency Measures Presented at Brown Bag Session November 29, 2006.
By HARSHAL SURANGE, ACR PROJECT CONSULTANTS PVT. LTD.
Ductless Heat Pumps in Residential Applications Proposed Research Plan.
+ Impact Evaluations and Measurement and Verification First we will focus on ‘Gross Savings’ Determination - savings determined irrespective of why 1 Kentucky.
School Measure Proposals for Small and Rural Utilities.
Evaluation of Energy Savings for Strip Curtains Presented To RTF Scott Moore PECI Sr. Engineer June 2, 2009.
AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS
Dual Fuel + Hybrid System Selling.
Best Direction System Ltd.
Product Introduction.
Industrial Pump Motor VFDs: Provisional Standard Protocol Christian Douglass Regional Technical Forum 5/12/2015.
Floating Head Pressure for Refrigeration Single Compressor Systems Michele Friedrich, PE – Sr. Engineer Dustin Bailey – Engineer PECI 11/2/2010.
Today’s “Game Plan” Two Trial-Runs of a new deemed measure review process – Deemed measure analysis and review Developed by … – (consultant, RTF member/staff,
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee April 25, 2012 Mira Vowles, P.E., CEM Emerging.
1 Air Source Heat Pumps Potential Changes in the RTF’s Specifications & Savings Estimates and Their Impact on C&R Discount Program Credits.
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee November 16, 2011 Mira Vowles, P.E., CEM.
ENERGY CONSERVATION BUILDING CODE – 2006 PRESENTATION BY VP GUPTA PRINCIPAL CHIEF ENGINEER (ELECTRICAL), BSNL CHENNAI.
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
General Troubleshooting Tips.
Retrofit Doors to Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Pump VFD Provisional Standard Protocol Regional Technical Forum June 18, 2013.
Non-Res Lighting Subcommittee Retrofit Lighting Standard Protocol Review 04/03/14.
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
Agricultural Irrigation Pump Variable Frequency Drive Provisional Standard Protocol Proposal Regional Technical Forum April 16, 2013.
Out-Of-Compliance Grocery UES Measure Recommendations Regional Technical Forum March 18, 2014.
LED Case Lighting in Vertical and Semi-Vertical Open Refrigerated Cases Eric Mullendore – Energy Analyst PECI 6/29/2010.
EnergySmart Grocer Program Evaluation Findings Summary PWP, Inc.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Regional Technical Forum October 9, ECMs for Compressor Head Cooling Fans  Measure –Retrofit of compressor head cooling fans on low temperature.
Grocery Measure: EC Motors for Display Cases Regional Technical Forum June 16 th, 2015 Mohit Singh-Chhabra.
Strip Curtains for Refrigerated Walk-in Boxes Michele Friedrich, PE – Sr. Engineer Eric Mullendore – Energy Analyst PECI 8/3/2010.
RTF Pump VFD Provisional Standard Protocol Regional Technical Forum June 18, 2013.
“Do Green” Two Options: Prescriptive Custom Prescriptive- -Must be running a MODULATING ROTARY SCREW AIR COMPRESSOR -Must be 75 Horsepower or Less Custom-
Deemed Savings Update: ECMs in Display Cases Ben Cartwright PECI January 5, 2009.
Update: Grocery Refrigeration Provisional Standard Protocol for Site Specific Savings RTF Meeting June 28,
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 22, 2012 Mira Vowles, P.E., CEM.
BPA M&V Protocols Overview of BPA M&V Protocols and Relationship to RTF Guidelines for Savings and Standard Savings Estimation Protocols.
EER Analysis Results Regional Technical Forum March 18, 2014.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 27, 2013 Mira Vowles, P.E., CEM.
RTU Savings Research Project RTU Savings Research Project: Findings and Recommendations Regional Technical Forum February 3, 2009 Mark Cherniack Howard.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
Standard Protocol Development for Advanced RTU Control Retrofit August 15, 2013 Presentation to: Regional Technical Forum RTUG Subcommittee Sponsored by:
Measurement and Verification of Refrigeration Measures in 4 Grocery Stores in Pacific County Presented to the Regional Technical Forum August 8 th, 2006.
2010 Massachusetts Energy Efficiency Programs July 1, 2010.
High Efficiency Evaporator Coils for Medium Temperature Cases Dustin Bailey, Engineer PECI Jan 5, 2010.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee August 28, 2013 Mira Vowles, P.E., CEM.
The RTU Annual Usage Calculator (companion to RTU protocol SBW format) is Excel sheet for a single site 4- week monitoring (often automated using SAS for.
Grocery Store Issues RTF April 10, Need Recommendations PECI: Energy Smart Grocer Program Savings method for interactive measures Savings method.
Grocery VSD Measure Deemed Savings Reid Hart, PE & Ken Anderson September 28, 2010.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee July 24, 2013 Mira Vowles, P.E., CEM Emerging.
GrocerSmart TM Energy Modeling Software -Revision Status Report- & -Request For Input- July 13, 2010.
BasicRefrigerationSystem 4 Component Flow Diagram.
A Reliable but Simplified Method for Measuring the Savings from Advanced RTU Control Retrofits February 13, 2013 Presentation to: RTF Commercial Rooftop.
Regional Technical Forum Recommissioning commercial retail facilities: A whole building approach to energy savings April 7th, 2009 Presented by: Jeremy.
Calculating Energy Use and Converting Units Chapter 2.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Performance Tested HVAC Presentation to the RTF January 5, 2010.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
Metering and Measuring of Multi-Family Pool Pumps, Phase 1 March 10, 2016 Presented by Dan Mort & Sasha Baroiant ADM Associates, Inc.
Refrigeration What's Refrigerated? What makes up a system?
Enhancing The Efficiency Of New And Existing Cooling Systems Dr Robert Lamb CEng FInstR Group Sales & Marketing Director Star Refrigeration Ltd.
A Calculator for Reliably Measuring the Savings from Advanced RTU Control Retrofits August 27, 2015 Presentation to: RTF Commercial Rooftop Unit Working.
WELCOME. Glycol Refrigeration A most basic definition of refrigeration is taking heat from someplace we don’t want it and moving it to someplace where.
Comparative Analysis 2011 Sanyo 10 Ton HVAC And Sanyo 10 Ton HVAC Equipped with Mysticool® Max from XDX®
NET-ZERO-ENERGY (NZE) WASTEWATER TREATMENT PLANTS (WWTPs)
Presentation transcript:

July 26, 2014 Refrigeration Subcommittee Proposed Revision of Refrigeration Provisional Data Requirements

Data Collection for demonstration projects

3 Demonstration project data collection best practices method

4 Measurement Projects actual measurements Best Practices from Table 8.1 Compressor power (kW) and energy o 15 minute interval data compressor current (3-phs). Volts measured once. o Electric power (kW) measured over time o Maximum 5-minute interval data o Data collection must use watt meter as compressor efficiency and power factor varies with load on motor. Condenser fan electric power (and pump motor for evaporative-cooled condensers) (kW) and energy o 15 minute interval data fan current (3-phs). Volts measured once. o Same interval as compressor data. o Volts and power factor (3-phs) measured once o Amps measured over timeasured once o If there is a VFD or 2-speed fan, watt meter data is needed as motor efficiency and power factor varies with load Display case electric power (kW) and energy o 15 minute interval data for lighting and ASH curcuits o Maximum 15-minute interval data o Volts and power factor (3-phs) measured one time o Amps measured over time to estimate kWh Walk-in electric power (kW) and energy o 15 minute interval data for motor circuits o Maximum 15-minute interval data o Volts and power factor (3-phs) measured one time o Amps measured over time to estimate kWh Outside air temperature o Hourly weather data from Vancouver airport NOAA station o Drybulb or wetbulb, depending on condenser type o Shaded to prevent solar o Maximum 30-minute log data, maximum sampling time 1-minute o Accuracy +/- 1 F Suction Pressure (psig) o From EMS, 3 day samples pre and post o Pressure sensor with +/- 2% of FS o Maximum sampling time 5 seconds, maximum 5-minute log data Discharge pressure o From EMS, 3 day samples pre and post o Pressure sensor with +/- 1% of FS o Maximum sampling time 5 seconds, maximum 5-minute log data Outside relative humidity o Hourly weather data from Vancouver airport NOAA station o Accuracy of +/- 2% RH between 10% and 90% o Maximum sampling time 1-minute o Maximum log time 30 minutes TMY3 NOAA data for weather site used in DOE2.2r o Hourly weather data from Vancouver airport NOAA station o Temperature o Correlation between site temperatures and weather station data

Project #1 Data Collection and Calibration

6 Regression analysis (Best Practices) Collection Periods: Pre: 2/27 to 4/22 Post: 4/22 to 7/9 Methodology for regression Average daily temp from NOAA as independent Averaged hourly compressor power Compressor power as dependent Linear regression Method for calculating annual savings Applied linear regression to average daily TMY3

7 Regression analysis Pre measure implementation

8 Regression analysis Post measure implementation

9 Regression analysis Pre measure implementation

10 Regression analysis Post measure implementation

11 Best Practice model results Pre: kWh = (Temp) Post: kWh=-1.486(Temp) kWh Pre221,697 Post184,123 Savings37,573 % Savings17%

Simplest reliable method

13 SRM analysis Audit data collected (See protocol appendix) DOE2 Simulation with TMY3 kWh Pre375,103 Post320,687 Savings54,416 % Savings14.5%

14 Calibration adjustments Focused on rated compressor power and capacity Used manufacturer’s selection tool as a guide Increased capacity and power to adjust baseline and savings

15 SRM Results kWh Pre229,914 Post192,988 Savings36,926 % Savings16%

16 Comparison of BP and SRM

©2014 PECI All rights reserved. Thank you subcommittee!

18 Demonstration project data collection simplest reliable method Remove what was not used for model, a

19 Revisions: Table 8.1 Provisional Data Collection

20 Revisions: 8.1 Provisional Data Collection

21 Revisions: 8.1 Provisional Data Collection

Calibration: Model parameter examples Compressors  Rated power  Rated refrigerant flow  Evaporator superheat  Return gas temperature  COP curves Loads  Fixture infiltration  Light, fan, and ASH absorbed into fixtures  Sales space humidity levels

Calibration: Keyword adjustments

Calibrated model results

25 Data Collection Individual compressor data

Next Steps Recommendations on approach, documentation Review next projects as available