Application of the Root-Locus Method to the Design and Sensitivity Analysis of Closed-Loop Thermoacoustic Engines C Mark Johnson.

Slides:



Advertisements
Similar presentations
C. M. Johnson, P. H. Riley and C. R. Saha Thermo-acoustic engine converts thermal energy into sound energy by transferring heat between the working media.
Advertisements

The Performance of Feedback Control Systems
Dynamic Behavior of Closed-Loop Control Systems
RF Communication Circuits
Chapter 10 Stability Analysis and Controller Tuning
30 th September 2004 High Power RF Couplers James Rogers High Power RF Couplers ELSRF Daresbury Laboratory.
Loop Shaping Professor Walter W. Olson
UNIVERSITI MALAYSIA PERLIS
CHE 185 – PROCESS CONTROL AND DYNAMICS
Chapter 8 Root Locus and Magnitude-phase Representation
Analysis of SISO Control Loops
RF & Microwave Engineering
Transient and steady state response (cont.)
ECE53A RLC Circuits W. Ku 11/29/2007
Out response, Poles, and Zeros
ENE 428 Microwave Engineering
Tutorial 5: Numerical methods - buildings Q1. Identify three principal differences between a response function method and a numerical method when both.
APPLICATION OF THE LAPLACE TRANSFORM
Lecture 8 Periodic Structures Image Parameter Method
Impedance Matching and Tuning
EKT 441 MICROWAVE COMMUNICATIONS
In Engineering --- Designing a Pneumatic Pump Introduction System characterization Model development –Models 1, 2, 3, 4, 5 & 6 Model analysis –Time domain.
Automatic Control Theory-
Automatic Control System
ENE 490 Applied Communication Systems Lecture 3 Stub matching, single- and two-port networks DATE: 27/11/06.
IMPEDANCE MATCHING IN HIGH FREQUENCY LINES UNIT - III.
Attribute Assessment Implementation – ME 4R03 Saeid Habibi.
2-1 (a),(b) (pp.50) Problem: Prove that the systems shown in Fig. (a) and Fig. (b) are similar.(that is, the format of differential equation is similar).
The Root Locus Analysis Eng R. L. Nkumbwa MSc, MBA, BEng, REng. Copperbelt University.
Maximum Gain Amplifiers For the two-port network shown below, It is well known that maximum power transfer from the source to the transistor occurs when:
Professor Walter W. Olson Department of Mechanical, Industrial and Manufacturing Engineering University of Toledo Loop Shaping.
ME375 Handouts - Spring 2002 Root Locus Method.
Dept of Aeronautical Enggineering S.M.M. Rahman MIST Direct Current Limitations: Transmission Loss No Amplification Power Distribution Lim.
Order of Magnitude Scaling of Complex Engineering Problems Patricio F. Mendez Thomas W. Eagar May 14 th, 1999.
Modern Control Systems (MCS) Dr. Imtiaz Hussain Assistant Professor URL :
ENE 428 Microwave Engineering
Lec 9. Root Locus Analysis I From last lecture, the locations of the closed loop poles have important implication in –Stability –Transient behavior –Steady.
Subsea Control and Communications Systems
19.4 Load-dependent properties of resonant converters
Root Locus Techniques (Sketching Method) Date: 25 th September 2008 Prepared by: Megat Syahirul Amin bin Megat Ali
Dr. Tamer Samy Gaafar Automatic Control Theory CSE 322 Lec. 11 Root Locus.
Modern Control System EKT 308
Prof. Wahied Gharieb Ali Abdelaal
1 Control of maldistribution of flow in parallell heat exchangers Magnus G. Jacobsen, Sigurd Skogestad Nordic Process Controi workshop, Porsgrunn
Chapter 2. Transmission Line Theory
EKT 441 MICROWAVE COMMUNICATIONS
Shroff S.R. Rotary Institute of Chemical Technology Chemical Engineering Instrumentation and process Control.
SKEE 3143 Control Systems Design Chapter 2 – PID Controllers Design
Lecture 11/12 Analysis and design in the time domain using root locus North China Electric Power University Sun Hairong.
Part B – Effect of Feedback on BW
Lesson 20: Process Characteristics- 2nd Order Lag Process
Laplace Transforms Chapter 3 Standard notation in dynamics and control
Youngjune, Han Chapter 4 Time Response Youngjune, Han
Estimation of the critical temperature ratio
Microwave Engineering by David M. Pozar Ch. 4.1 ~ 4 / 4.6
Part B – Effect of Feedback on BW
Chapter 6 Feedback Circuits
topics Basic Transmission Line Equations
Root-locus Technique for Control Design
Root Loci Analysis (3): Root Locus Approach to Control System Design
UNIVERSITI MALAYSIA PERLIS SCHOOL OF ELECTRICAL SYSTEM ENGINEERING
Root Locus Techniques CH 8: Islamic University of Gaza
Root-Locus Analysis (2)
Chapter 4. Time Response I may not have gone where I intended to go, but I think I have ended up where I needed to be. Pusan National University Intelligent.
Root Locus Techniques CH 8: Islamic University of Gaza
CH. 6 Root Locus Chapter6. Root Locus.
N-port Network Port reference Line Impedance Port Voltage & Current.
Time Response, Stability, and
Exercise 1 For the unit step response shown in the following figure, find the transfer function of the system. Also find rise time and settling time. Solution.
Presentation transcript:

Application of the Root-Locus Method to the Design and Sensitivity Analysis of Closed-Loop Thermoacoustic Engines C Mark Johnson

Overview The Design Challenge Frequency Domain Analysis Laplace Domain Analysis Root Locus Approach to Instability Design Parametric Optimisation Addition of Heat Transfer Parametric Output Power Response Use of Tuning Stubs Conclusions

The Design Challenge Travelling wave loop with alternator mid-loop and 2 side branches Simplified equivalent Loop must oscillate: added power = losses + alternator Steady-state frequency domain analysis Pressure and volume velocity must match around the loop

Power Balance For travelling wave loop, available acoustic power is a fraction of the loop power: Carnot efficiency = max. possible: Alternator absorbs acoustic power: For steady oscillation: Depends on ratio of volume velocities, alternator parameters & engine conditions

Pressure and Vol. Velocity Simultaneous solution requires 4 independent variables (e.g. q1, q2, Ae, ra) Power balance equality must be satisfied

Effect of Alternator Position Normalised pressure, volume velocity and impedance at the alternator as a function of alternator position (q1) Position of alternator must satisfy condition for velocity ratio from both ends of the loop Determines the minimum thermoacoustic gain (kTA) for oscillation under varying acoustic engine conditions (Ae)

Conditions for Oscillation Minimum achievable velocity ratios (determined from AHX and HHX) and corresponding onset temperature as a function of (real) pressure ratio Ae Possible to establish boundaries to design space but… Difficult to gain further insight into optimisation of system parameters

Laplace-Domain Approach Laplace-domain analysis can be applied to study the time-domain (transient) behaviour as well as steady state Solution of the characteristic equation for the loop gives the poles of the transfer function Opens up new possibilities: Parametric stability analysis of a system, for example by plotting root loci as functions of temperature, load resistance, feedback pipe parameters Design optimisation in which geometrical and physical parameters may be varied to achieve specific targets, for example: Maximising the real part of dominant pole pair Minimising the temperature at which the dominant pole pair lies on the imaginary axis Note that the pressure and velocity are not solved for explicitly: reduces the number of equations from 4 to 2

Two-Port Networks Analysis based on the assumption that all thermoacoustic loop elements may be represented by a 2-port equivalent Each element is based on a modified waveguide representation, including arbitrary shunt and series impedances Input and output pressure and volume velocity of each element can then be represented:

Propagation Matrix Feedback system representation of thermoacoustic loop Whole loop is represented by a cascade of the S-parameter matrices for each element The poles of the closed-loop transfer function are determined by solving the characteristic equation: System can be solved in full to determine impulse response, frequency response etc. using Laplace solution methods e.g. poles and residues

Stability Analysis In solving for the transfer function poles (two equations, two unknowns) we gain far more information about the system response than can be obtained from a simple frequency domain representation Can explore the system stability characteristics in response to changes in geometrical and other system parameters For a loop containing a number of undetermined parameters e.g. feedback pipe length, feedback pipe diameter, it is possible to find the region of instability and then determine an optimum operating point Boundary of the region of instability corresponds to the condition for steady oscillations (a conjugate pair of poles placed on the imaginary axis) and thus represents the limiting case for the onset of oscillation.

Root Locus Method Conditions for instability: Temperature > 550K Alternator load > 0.6W Combination of pipe lengths @ T=650K, RL=1W Solve characteristic equation to find dominant pole-pair and plot as function of selected parameters Positive real part indicates oscillatory behaviour Amplitude determined by e.g. onset of non-linearity, heat transfer limitations etc.

Effect of Pipe Lengths Real part of dominant pole for combination of pipe lengths @ T=650K, RL=1W a=0 “Strength” of instability related to positive real part of pole, a Area inside the a=0 contour is unstable and gives an indication of the margin of error permissible in construction or the range needed for tuning purposes

Engine Operating Conditions Magnitude of the impedance for the unstable region corresponds to values of engine pressure ratio Ae below 4 Phase plot shows pressure and velocity to be close to “in phase” with optimum loop parameters

Coupling with Heat Transfer Heat transfer added through auxiliary equations to represent heat flow through regenerator and transfer from HHX Lumped parameter representation of alternator and load Frequency domain solution Additional analyses enabled: Engine performance (efficiency, output) under varying acoustic and heat transfer conditions Power output (effect of changing parameters, optimisation) Tuning (using stubs to optimise output in presence of uncertainty)

Example Engine 1 Stub 1 Pipe E Engine 2 Pipe 1 Stub 2 Pipe 2 Alternator Dual series engine loop with radiant HHX (loosely based on SCORE demo 0_3) Two tuning stubs, nominal adjustment range 0.1 to 0.6 m Feedback pipes 100 mm, stubs 75 mm diameter Alternator based on idealised SCORE design

Engine Performance Available acoustic power strong function of regenerator temperature, radiant HHX temperature, acoustic conditions (enforced pressure ratio Ae) Drop in power/efficiency at high temperatures due to solid conduction through regenerator

Stability Real part of dominant pole for combination of pipe lengths @ T=750K, RL=1W Real part of dominant pole-pair as function of feedback pipe lengths Significant unstable region reflecting additional gain from series engines

Power Response Electrical power output Hot end temperature Simultaneously solve acoustic loop and heat transfer equations: hot end temperature varies Peak power output at regenerator hot end temperature of ~550K corresponds to peak engine efficiency Optimum pipe lengths do not correspond to those for greatest instability as temperature is now a variable

Tuning Power response Tuned response Power response (left) determined with fixed side branch length Optimised response (right) determined with varying side branch lengths Possible to maintain virtually constant output power by tuning

Conclusions Frequency domain techniques can be difficult to apply to design of thermoacoustic loops Laplace domain techniques offer an attractive alternative by allowing use of standard methods such as root locus for determining feasible operating regimes Optimisation and parametric sensitivity analysis can be performed without explicitly solving for acoustic variables Coupling with heat transfer equations allows complete steady-state solution to be determined Application to e.g. output power optimisation, sensitivity analysis and tuning