NMLTA Protection System Update -Loss Monitors- Arden Warner October 13 th, 2010 Arden Warner, FNAL.

Slides:



Advertisements
Similar presentations
Geiger Counters. Higher Voltage As the voltage increases in a gas detector the ions collected increases. The proportional region ends. –Streamer mode.
Advertisements

The Multi-PMT Optical Module P.Kooijman, University of Amsterdam University of Utrecht Nikhef.
Digital to Analog and Analog to Digital Conversion
1 Arden Warner, FNAL Beam Loss Monitors operating at Cryogenic Temperature with FPGA- Based TDC Signal Processing Arden Warner, Manfred.
Part A: Controlling Oscillation Frequency with Capacitors and Resistors Part B: Diodes and Light Experiment Timer.
F.Brinker, DESY, July 17 st 2008 Injection to Doris and Petra Fitting the detector in the IP-region Radiation issues Beam optic, Target cell Polarisation.
LECC 2006 Ewald Effinger AB-BI-BL The LHC beam loss monitoring system’s data acquisition card Ewald Effinger AB-BI-BL.
Scintillation Detectors
Slide # 1 Examples of pressure sensor packaging Temperature characteristics of a piezoresistive pressure sensor. Transfer function at three different temperatures.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
Hydrogen Recombination Time (µs) RF Envelope (V) Here So We get Calculated from # of protons per bunch Calculated from energy loss (voltage drop) in the.
Photon detection Visible or near-visible wavelengths
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
1 S. E. Tzamarias Hellenic Open University N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Readout Electronics DAQ & Calibration.
Status of the ASTA Facility Machine Protection System at Fermilab Arden Warner June 6 th, 2012.
Scintillators, DAQ boards, and PMTs Getting Familiarized With the Equipment By Melissa Sussmann and Alex Bonnifield.
BPMs and HOM-BPMs for the XFEL Linac N. Baboi for the BPM and the HOM teams (DESY, CEA-Saclay, SLAC, FNAL, Cockroft/Daresbury) XFEL Linac Review Meeting,
Anatoli Konoplyannikov Design and integration of HV, LED monitoring and calibration system for HCAL Overview of the subsystems design High voltage.
BI day 2011 T Bogey CERN BE/BI. Overview to the TTpos system Proposed technical solution Performance of the system Lab test Beam test Planning for 2012.
THE FAST X-RAY MONITOR (FXM) BASED ON YAP:CE SCINTILLATOR (YTTRIUM ALUMINUM PEROVSKITE ACTIVATED BY CERIUM) FOR THE “CORONAS-PHOTON” SATELLITE PROJECT.
Xiao-Yan Zhao Beam Instrumentation Group Accelerator Center, IHEP BEPCII Background Issues: Beam Loss Measurement.
A Novel Digitization Scheme with FPGA-based TDC for Beam Loss Monitors Operating at Cryogenic Temperature Wu, Jinyuan, Arden Warner Fermilab Oct
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
Lead Fluoride Calorimeter for Deeply Virtual Compton Scattering in Hall A Alexandre Camsonne Hall A Jefferson Laboratory October 31 st 2008.
HBD Gas and QE Monitoring Craig Woody BNL HBD Working Group Meeting October 19, 2005.
Abort Gap Monitoring Randy Thurman-Keup 6 / 8 / 2004 LARP Meeting.
Techniques for Nuclear and Particle Physics Experiments By W.R. Leo Chapter Eight:
P.W. Gorham et al.. TEST BEAM A SLAC Time relative to beam entry Antenna V/V rms Time relative to beam entry Antenna V/V rms close to shower maximumshower.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
7/28/2003DC/EC Review Aerogel Read out Electronics K. Ozawa, N. Kurihara, M. Inaba, H. Masui T. Sakaguchi, T. Matsumoto.
L.Royer– Calice LLR – Feb Laurent Royer, J. Bonnard, S. Manen, P. Gay LPC Clermont-Ferrand R&D pole MicRhAu dedicated to High.
FIT (Fast Interaction Trigger) detector development for ALICE experiment at LHC (CREN) Institute for Nuclear Research (INR RAS) National Research Nuclear.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
28 June 2007G. Pauletta: ALCPG Tests of IRST SiPMs G. Pauletta Univ. & I.N.F.N. Udine Outline 1.IRST SiPMs : baseline characteristics 2.first application.
Gain stability and the LYSO beam radiation monitor measurements
LHC Beam Loss Monitors, B.Dehning 1/15 LHC Beam loss Monitors Loss monitor specifications Radiation tolerant Electronics Ionisation chamber development.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
1 Arden Warner, FNAL Beam Loss Monitors operating at Cryogenic Temperature with FPGA- Based TDC Signal Processing Arden Warner and Jin-Yuan.
DaMon: a resonator to observe bunch charge/length and dark current. > Principle of detecting weakly charged bunches > Setup of resonator and electronics.
BRANs Sune Jakobsen (BE-BI-PM) LHC BI 2015 summary
PROPOSAL FOR A MUON VETO SYSTEM BEHIND THE HADRONIC CALORIMETER (MUV-3) Problems and requirements:  Expected total rate for 9.25 < R < 120 cm: 12.1 MHz:
Development of a High Resolution Cavity BPM for the CLIC Main Beam
SEM SIC SEM SIC 2 SEMs & 2 SICs closed to the Dumps 1 SIC, 1 Faraday cup & 1 SEM SEM SIC F. cup 4 similar set-ups : Girder 6,7,11 and 13 4 th – 8 th October.
Beam Profile Monitor for Spot-Scanning System Yoshimasa YUASA.
05/12/2014 Gerrit Jan Focker, BE/BI/PM 1 PSB-Injection H - and H 0 Dump detectors and Stripping Foil current measurement.
R&D status of the very front end ASIC Tilecal week (7 October 2011) François Vazeille Jacques Lecoq, Nicolas Pillet, Laurent Royer and Irakli Minashvili.
Estimates of required MPS reaction time In the merger (at the centers of respective 20deg dipoles and in between 2 lenses) rms R=250 um In the
PXIE Beam Instrumentation Status Update – Preparing for MEBT 1.1 Beam Vic Scarpine Feb. 9, 2016.
G. Kieft Nikhef Amsterdam Electronics- Technology PMT tubes PMT bases PMT asic’s Automatic tester for PMT bases Camac test set-up for PMT tubes LeCroy.
ASTA Machine Protection System (MPS) Status and Commissioning Plan ASTA Machine Protection System (MPS) Status and Commissioning Plan Arden Warner Arden.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
PHOTOTUBE SCANNING SETUP AT THE UNIVERSITY OF MARYLAND Doug Roberts U of Maryland, College Park.
NMLTA Protection System Update -Loss Monitors- Arden Warner September 2 nd, 2009.
FARICH status E.A.Kravchenko Budker INP, Novosibirsk, Russia.
 13 Readout Electronics A First Look 28-Jan-2004.
IFR Detector R&D status
Activities at SMI/Vienna in testing the performance of SiPMs
Alexander Aleksandrov Spallation Neutron Source Oak Ridge, USA
Results achieved so far to improve the RPC rate capability
Overview of the project
PAN-2013: Radiation detectors
A First Look J. Pilcher 12-Mar-2004
Department of Physics and Astronomy,
BESIII EMC electronics
Scintillation Counter
Development of hybrid photomultiplier for Hyper-Kamiokande
Pre-installation Tests of the LHCb Muon Chambers
UITF Conduct of Operations Review
Presentation transcript:

NMLTA Protection System Update -Loss Monitors- Arden Warner October 13 th, 2010 Arden Warner, FNAL

Status of loss monitors Two FBLMs were designed at FNAL and manufactured by Bridgeport Instruments and Elgen Technology. Both prototypes installed at A0 photo-injector.  Paddles designed to have ~ 40% less scintillator material than that used at DESY  Hamamatsu and ET Enterprise PMTs with comparable specifications See properties in table below: 2 EJ208 Scintillator propertiesValue Rise time1.0 ns Scintillator Brightness76 p.e./ MeV Wavelength of max emission435 nm Detector sensitivity7.0 pC/Mev Decay time3.3 ns Density1.023 g/cc Light attenuation length 1/e210 cm Number of electrons3.37/cm 3 PMT Specifications Rise time3-5 ns Gain (min)2.7 x 10 5 Supply voltage (max)2000 volts Sensitivity0.1 – 200 A/lm Arden Warner, FNAL

3 Fast Beam Loss Monitor Design (BI prototype) Located near cross 8 Cost : Bridgeport Instruments 1 ea. $2350 each 40 ea. $1300 each Arden Warner, FNAL

4 Fast Beam Loss Monitor Design (EL prototype) Upstream of Radio-beam cross Cost : Elgen Tech 1 ea. $1878 each 50 ea. $1545 each Arden Warner, FNAL

FBML Measurements (BI prototype) 10 bunches to radio-beam dump. Cross 6 inserted Same signal with averaging turned on Zoom on bunches 250 pC/bunch Detector located downstream of cross8 115mm from DIAX07 cross. (-500 volts on divider) Arden Warner, FNAL

FBLM Measurements (BI prototype) Corresponding dark current background with no photoelectrons Arden Warner, FNAL

FBML Measurements (BI prototype) 40 bunches, 400 pC, cross4 OTR inserted Dark current upstream of beam loss at exit of capture cavity 25mm from GV2 Cross8 FBLM showing Loss photo-electrons + dark current Shutter closed Dark current/photo- electron beam = 5/1 in this case. Arden Warner, FNAL

FBLM Measurements (BI prototype) Dark current background varies with machine tuning and 9cell on/off as expected 10 intended bunches, last 2 bunches near end of rf cycle Signal rise time ~40 ns Measured dark current to faraday cup: 220mV/50 ohms = 4.4 mA Arden Warner, FNAL

FBLM Measurements (Elgen prototype) ET Enterprise PMT. No mu- mental shield and no iron Lots of noise outside of rf pulse. The amount of required EMI and mu-mental shield can tested tested. Arden Warner, FNAL

10 Cryogenic Ionization chamber Type : Cryogenic beam loss monitors can be operate from inside the cryomodules from 5k to 350k. Design Properties:  Stainless steel vessel, 120 cm3 filled with He-gas.  He-gas pressure of 1 bar (0.98 atm)  Sensitivity 1.9 pA/(Rad/hr)  Readout via current-to-frequency converter (1.9Hz/(Rad/hr)  Range: up to 30 kRad/hr  Pulses can be sent through long cables Installation requirements:  BNC feed through (-95 volts)  Electrically isolated Arden Warner, FNAL

11 Cryogenic Ionization chamber 5k – 350K It is a helium-filled ionization chamber. It's current is proportional to the dose rate. ● The signal current is processed by a current to frequency converter to achieve a wide dynamic range and quick response dose rate excursions. ● All materials used are know to be radiation hard and suitable for operation at 5K. ● The electronics is self-contained and requires no computer to operate. Arden Warner, FNAL

The chamber housing is held at negative potential and negative charge is collected on the center electrode. The HV is -95 V and is kept well below the minimum breakdown voltage of 156V in Helium. Cryogenic Loss Monitor operation The electronics uses a recycling integrator as a current to frequency converter with a wide dynamic range. The charge per pulse is 1.63pC or 238µR at 1 atm (room temp) of He. The recycling integrator consist of a charge integrating amplifier with a 0.50 pF capacitance followed by a discriminator which senses when the capacitor is fully charged. The FPGA generates a fixed-width (1.2µs) discharge pulse with an amplitude of 3.3V. It connects to the amplifier input via a 13 MΩ resistor, creating a 254 nA discharge current 12 Arden Warner, FNAL

13 Cryogenic Loss Monitor proposed installation in CM2

Arden Warner, FNAL 14 Cryogenic Loss Monitor VME based counter/Timer board HTS installation Counter/timer show 630 counts = 150 mR

Arden Warner, FNAL 15 Conclusion on FBLM studies  The FBLMs manufactured by Bridgeport Instruments are well constructed and show good response.  The Hamamatsu R6231 PMT is linear and stable but some systematic studies with A0 beam conditions is needed.  Adequate shielding can be added to the design to reduce noise and shield from magnets. Provision was made in the design to include this.  A few minor modifications to accommodate the beam line can also be added.  Shielding needs to be included to finalize  PMT adequate but the assembly and connections were not done well.  Not happy with the construction and response. Bridgeport Design Elgen Design

Mode request Machine Protection System for NML

( To Photocathode Machine Protection System FPGA based Permit system > Laser Pulse Controller 81 MHz Oscillator ) 3 MHzPockels CellAmplifierPockels CellAmplifier shutter Beam mode 3 MHz Machine time Alarm (intra macro-pulse) Macro-pulse trigger Control output Block the Pockels cell based pulse kickers as long as the MPS input is in an alarm state. Enforce the limit on the number of bunches as given by the currently selected beam mode. Close the laser shutter on request of the MPS. This may happen when there is no valid operational mode or when some combination of loss monitors exceed thresholds which trigger a dump condition. MPS Laser pulse control