Vadodara institute of engineering,kotambi NAME:NAFISKHANPATHAN(13ELEE181) BARIYA VIPUL(13ELEE182) PATEL AMIT(13ELEE180) BRANCH:EE-2 PPT OF EEE.

Slides:



Advertisements
Similar presentations
L.T Circuit Breakers.
Advertisements

Seminar on Circuit Breaker
Cable Protection Matching Protection Devices to a Cable.
Electrical Installation
© Abb Control Ltd - 1 ABB Protection - Overload What do we mean by a fault? Overload Operating condition in an electrically undamaged circuit which causes.
Inspection & Preventive maintenance of breakers
SWITCHES, FUSES, & CIRCUIT BREAKERS
Co-ordination of LV Protection Devices
MOLDED CASE CIRCUIT BREAKER BASICS
M iniature circuit breakers to UL 489
© ABB Ltd - ATLV /26/2015 Insert image here Fuses vs Fuseless Technology.
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
Circuit Breakers and Busbars. Circuit Breakers Altech’s Circuit Breaker Line UL1077 (R-Series) UL508 (V-EA Series) UL489 (L-Series, AB-Series)
ACADs (08-006) Covered Keywords Switchgear, motor control, ground, circuit breaker. Description Supporting Material
MAIN ELECTRICAL SURVEY ITEMS, GENERATORS AND GOVERNORS,, CIRCUIT BREAKERS, SWITCHBOARDS AND FITTINGS (Adapted from:D.T. Hall:Practical Marine Electrical.
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
Electrical Power & Machines “Electrical Engineering Dept” Prepared By: Dr. Sahar Abd El Moneim Moussa 1.
SF6 load-break switch-disconnector
Miniature Circuit Breakers (MCB) Multi 9
Sales Training Outline 2006 Klaus Tum Product Manager NEW Circuit Breakers 35 Royal Road Flemington, NJ
Content Types of circuit breakers Operating principles of circuit breakers Inverse time/current characteristic of circuit breakers Circuit breakers.
MV SF6 circuit-breakers for secondary distribution
Breaker Basics Welcome to this general overview of ABB.
EE4503 Electrical Systems Design
Multi-function apparatus for secondary distribution
Welcome DIN Rail product training ISOLATOR/MCB/RCD/RCBO
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
ELECTRICAL COMPONENTS
Rocker Switches  Available in illuminated, Non-illuminated and Central illuminated version  Suitable for switching resistive and inductive load  Wide.
Overvoltage protection (surge arrester)
Standards LOW VOLTAGE Below or Equal to 1000V for AC & 1200V for DC
Area of Study 2: Electricity
Vidhyadeep Institute Of Management & Technology, Anita, Kim Electronics & Communication Department Guided by Mr. Vicky Paperwala.
Overcurrent protection devices
Electrical Installation Practice 2
Electrical Installation 2
Electrical Fundamentals Parts Technician First Period Material Identification and Calculations e.
Electrical Distribution Training
Upgrade of the Breakers Control Module in 13 kA EE systems Bozhidar Panev TE-MPE-EE
High Current Testing of Molded Case Circuit Breakers
SARDAR PATEL INSTITUTE OF
AC DC SYMBOLS Learning the Symbols. AC POWER SUPPLY.
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
Protection & Switchgear
Protection and switchgear
Elec467 Power Machines & Transformers Electric Machines by Hubert, Chapter 12 Topic: Self-excited and compound generators, load distribution.
Introduction to switchgears
ΜΕΣΑ ΔΙΑΚΟΠΗΣ, ΠΡΟΣΤΑΣΙΑΣ ΚΑΙ ΕΛΕΓΧΟΥ ΚΥΚΛΩΜΑΤΩΝ ΟΙΚΙΑΚΩΝ ΗΛΕΚΤΡΙΚΩΝ ΕΓΚΑΤΑΣΤΑΣΕΩΝ ΣΤΟΧΟΣ: Ο μαθητής να: αναγνωρίζει και να επιλέγει τα κατάλληλα Μέσα.
1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
5SV9 Residual Current Circuit Breakers with Overcurrent Protection
Frei verwendbar / © Siemens AG Alle Rechte vorbehalten.siemens.com/answers 5SU9 Residual Current Circuit Breakers with Overcurrent Protection SENTRON.
MCB Connor, Sunny, Kia. What does it do? A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from.
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
  The traditional molded-case circuit breaker uses electromechanical (thermal magnetic) trip units that may be fixed or interchangeable.  An MCCB provides.
Circuit Breakers CBI and ETA product offerings. Breaker Technologies - Hydraulic-Magnetic Not effected by ambient temperatures Possible to obtain any.
Push Button Station and Relay
Product Training Module
PROTECTION AGAINST INDIRECT CONTACT
Name, department/event, date
MV vacuum circuit-breakers for secondary distribution
Electrical Installation Practice 2
ELECTRICAL POWER-II Electrical engineering sixth semester
Overcurrent Protection— Fuses and Circuit Breakers
Presentation transcript:

Vadodara institute of engineering,kotambi NAME:NAFISKHANPATHAN(13ELEE181) BARIYA VIPUL(13ELEE182) PATEL AMIT(13ELEE180) BRANCH:EE-2 PPT OF EEE

Miniature circuit breaker(mcb)

Miniature Circuit Breakers (MCB) Multi 9

Protect cables against overloads and short circuits Let the current flow without overheating on cables Open and close a circuit under rated current Protect against insulation faults (see earth leakage protection module) Definition Main functions Miniature circuit = switch + trip unit breaker (MCB)  Symbol

A mechanical system to open and close the circuit A bimetal strip to act against overloads A magnetic trip to act against short circuits Definition A Multi 9 circuit breaker has: Miniature circuit = switch + trip unit breaker (MCB) 

It has standardized modular dimensions   125A   50 kA   440 V CA Definition Main performances It fits in your pocket... 

Definition Multi 9 standard  Multi 9 switchgear comes in 9 mm pitch  width symmetrical rail external part depth 6010 maxi maxi 44 maxi The modular design meets 2 criteria:  mounting on a 35 mm symmetrical rail  dimensions - modules in widths of 17.5 mm external part = 45 mm - depth between 55 and 70 mm

The technology Active parts C60N NC100 / NC125 terminal fixed contact moving contact strip braid magnetic trip load side terminal terminal bimetral strip strip braid moving contact magnetic trip load side terminal strip braid bimetal strip 

Overload protection bimetal tripping bar bimetal tripping bar screw calibration strip braid NC45 NC100 / NC125 A bimetal strip is used:  to protect the cable against overloads  symbol: principle of the bimetal: in a Multi 9 circuit breaker 

Thermal tripping curve the "thermal" part of the tripping curve must be in accordance with the standard Overload protection Legend: In = rated current Ind = no tripping current Id = tripping current  tripping no tripping destruction of bimetal accuracy t (s) I/InInIndId

Overload protection Simultaneous multi-pole tripping  Temperature derating  our circuit breakers do not have temperature compensation  if the calibration temperature is different from the ambient temperature: derating is required

Short-circuit protection Short-circuit current is given as RMS or peak (Isc or Îsc) RMS = Root Mean Square in symmetrical DC (with PF = I) Short-circuit protection must limit thermal stress in the cable in order to prevent cable damage (which may reach vaporization of the copper in some cases) Comments slide 29

Short-circuit protection "By-pass" technique for the protection of sensitive parts of the circuit breaker DC breaking is difficult "By-pass" technique for the protection of sensitive parts of the circuit breaker (magnetic trip) The arc in Multi 9 circuit breakers 2 breaking techniques used by Multi 9  arcing horn arcing horn NC45NC100 / NC125

Short-circuit protection Magnetic tripping curve Our curves are instantaneous tripping curves  Legend: Ind = no tripping current Id = tripping current destruction of the solenoid tripping no tripping t (s) I/InIndId

B curve  3 and 5 In protection low short-circuit current generators The magnetic tripping levels with high inrush current: like LV/LV transformers C Curve  5 and 10 In control and protection of circuits with high short-circuit current in industrial and domestic distributions D and K curves tripping betwen  tripping: 10 to 14 In; more particulary adopted for installations with high inrush currents like LV/LV transformers Z curve  2.4 to 3.6 In protection against electronic circuits MA curve  12 In; protection only against short-circuit and high inrush currents such as motors, coil  G M

Side panel marking: Marking Front panel marking: Circuit breaker marking is governed by strict rules in accordance with the standards and decisions made by the manufacturer 

Choosing a circuit breaker In conclusion A Multi 9 circuit breaker is determined by:  rating  breaking capacity  number of poles  voltage  tripping curve  standard  frequency  type of load 

Auxiliaries: C60  SD: alarm switch  MX + OF: shunt trip  MN: undervoltage release The information is transmitted via a mechanical link C60/NC100 and NC125 auxiliaries are not compatible  54 mm maxi 4 types of auxiliaries for our Multi 9 circuit breakers  OF: indication switch MX+OF OF SD C60 44/3 MN 51/3 52/3 54/3 53/3

Auxiliaries: NC100 - NC125 The information is transmitted via a mechanical link C60/NC100 and NC125 auxiliaries are not compatible  NC100H MX+OF or Vigi MN or OF SD 33/334/3 35/3 36/3 27/3  SD: alarm switch  MX + OF: shunt trip  MN: undervoltage release 4 types of auxiliaries for our Multi 9 circuit breakers  OF: indication switch

THANKYOU