Internal Fault Detection in Padmounted Distribution Transformers Western Underground Committee Fall Meeting – 9/26/12 Paul Henault – IFD Corporation.

Slides:



Advertisements
Similar presentations
Introducing Electricity and Electrical Safety
Advertisements

Basic safety rules and procedures for controlling hazardous energy
Revenue Protection & Safety Field Safety. Safety First Section 1.5 Personal Protective Equipment.
The Electrical GuruTM Paul W. Abernathy,CME
Speaker Scott Whaley - EIT Protecting & Ice Melting Westmans Distribution Lines.
Richard (Rick) Elwell Senior Operations and Safety Instructor and Consultant
Electrical Installation
The D.C. Scout Battery Distribution System Ground Locator
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
MABAS Division 10 - Com Ed Program1 Electrical Safety Reference: The Power of Training Electrical Safety Commonwealth Edison Company.
Lift Safety EZ Up 10’ Lift. Training Objectives  Identify lift hazards  Understand OSHA equipment requirements  Know how to inspect equipment  Take.
Two-mode Safety and Battery System Service
ELECTRICAL SAFETY-RELATED WORK PRACTICES Qualified Persons Those people that have training in avoiding electrical hazards while working on or near exposed.
CHREID 2008 ELECTRICAL SAFETY Introduction and Overview of Safety Clayton H. Reid September, 2010.
Qualified Persons Working On Or Near Energized Equipment
Controlling Hazardous Energy
Module 1A: Safety and Health Alexander MacFarlane.
Charging System Service
Circuit Protection Electrical circuits require protection to prevent fire or electrocution in the event of a fault. There are two main types of circuit.
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
Student Book © 2004 Propane Education & Research CouncilPage Applying Protective Coatings to Storage Containers ASME tanks require proper.
Troubleshooting Electric Control Devices
Electricity at Work.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Installation 2
SDG&E Electric Reliability Reporting CPUC Workshops May 26-27, 2015.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety.
Transformer Taking the ratio of the two equations
1a.  Exposed part  Live or energized part  De-energized part 1a.
Health & Hygiene/ELB Sample LOCKOUT/TAGOUT “APPROVED” TRAINING.
Electrical Safety. Definitions v Exposed part v Live or energized part v De-energized part 1a.
Lesson 6 Voltage Do we need to MEASURE it? OR Do we need to DETECT it?
Proper Use of Extension Cords
Pennsylvania Bureau of Deep Mine Safety Lockout/Tagout Program.
Utility Engineers, PC.  Generation  Transmission  Distribution.
Lockout/Tagout.
PSI Fill Station Operator (FSO) General info. on compressors Types of Fill stations Why to fill cylinders in a dry environment Fill station operator responsibilities.
Electrical Safety, Subpart K
The two types of electricity used in mining are: “AC” or alternating current and “DC” or direct current.
All About Workplace Electrical Safety
Klondex Midas Operations, Inc. Midas Mine Elko County, NV April 28, 2014 Machinery.
Working On or Near Energized Conductors and FR Clothing.
 The figure below shows a protection system for a transmission line, consisting of a CT, PT, a relay and its associated circuit breaker.
Electrical Safety Equipment
The D.C. Scout Battery Distribution System Ground Locator
Fuel Supply System Service
Personal Protective Equipment
Electrical Safety.
Cutting an In-Line Dead-end Single Phase
EET 323 – Electrical System Design Lecture 9: Grounding
Control of Hazardous Energy
Equipotential Grounding Procedures Protective Grounding Training
Safety Meeting Topics Standby Generator Safety
Click anywhere to get started…
A4 Insulator Changeout © 2018 Iowa Association of Electric Cooperatives.
A 3 Insulator Changeout With Hoists
A1 Pole Changeout Energized
URD Radial Feed Transformer Changeout
A1 Pole Changeout Energized
C1 Insulator Changeout © 2018 Iowa Association of Electric Cooperatives DISCLAIMER: This job hazard analysis (JHA) has been made available for informational.
Pad mounted 120/240 open 4 wire service
ST800 Service Tester, 800 Amps.
Parker domnick hunter. Safety of Electrical and
C1 Insulator Changeout © 2018 Iowa Association of Electric Cooperatives.
Isolation Link Operation
Risk Management Student Powerpoint
Presentation transcript:

Internal Fault Detection in Padmounted Distribution Transformers Western Underground Committee Fall Meeting – 9/26/12 Paul Henault – IFD Corporation

Presentation Outline  An overview of distribution transformer faults  Current industry issues and practices  Options for improvement  Questions

Common Utility Goals  Improve safety for line workers  Reduce outage times  Improve system reliability  Improve asset utilization  Prepare for the workforce of the future

What does an internal transformer fault look like?  A rapid, transient pressure rise occurs in every internal arcing fault  Variable peak pressure  Consistent rate of rise

Different fault locations, Same sudden pressure wave Near the Surface Near the Bottom

What does an internal transformer fault look like? Certification tests at Powertech Labs 500A test Arc Voltage Fault Current Pressure Rise IFD activates before peak ~ 3 psi

Why internal fault detection is important Linemen Safety  Operating challenges  Crew pressures  Risk every time we re-close Troubleshooting Effectiveness  Speed  Accuracy System Reliability  Reduce outage times  SAIDI/SAIFI

Why is internal fault detection important? Linemen Safety  Operating challenges  Crew pressures  Risk every time we re-close Troubleshooting Effectiveness  Speed  Accuracy System Reliability  Reduce outage times  SAIDI/SAIFI

Potential Costs Due to Unidentified Faulted Transformers  Safety & Environmental  Long outage times  SAIDI/SAIFI  Removing unfaulted transformers from service  Cost of troubleshooting tools

Causes of padmounted transformer fuse operations  Secondary Faults  Overloads  Oil Temperature (Dual Element Fuse)  Internal Transformer Faults

Internal Faults in Padmounted Transformers are usually not obvious externally

Current Industry Practices 1)Automatic Replacement 2)Field Testing 3)Trial & Error

Automatic Replacement  Most of the time the transformer is OK  Expensive and time consuming to remove the transformer, transport it to the shop, test it, and return it to service

Portable Field Testers* “Testers are expensive and not every vehicle has them” “They often don’t detect low grade transformer faults at the voltages that they generate” “I no longer use it because it kept indicating unfaulted transformers, but when I reenergized them, they often were faulted” *Lineman feedback

Trial and Error 1.Visual examination 2.Manual checks,  PRV  “Sniff…don’t inhale” 3.Attempt to reclose on transformer  “Push and pray”  “Now, crawl inside your helmet”  “Go get the new guy"

What about PRV’s?  PRV operation: P > 10±2 psi ≠ Internal fault  (Poppet style PRV) ‘does not have time to react to the overpressure rates of rise and values produced when low- impedance faults occur.’ A. Even et al., “Safety of Distribution Transformers against internal failure”, Conference Publication No. 438., IEEE, 1997

Product Development Co-Sponsors  National Research Council  Utilities: BC Hydro Hydro Quebec Manitoba Hydro Others  Transformer Manufacturers Technical specs Fault testing Field testing Certification Financial support Product value

Application Requirements 1)Primary function: Reliable detection of internal arcing faults >0.5 psi/5-7ms transient internal pressure [ ± 500 amps] High visibility Easy to install Maintenance free No effect on transformer Etc… 2)Also: Incorporate pressure relief valve in design

The Purpose To give electric utility employees the information they need to troubleshoot and restore power to distribution transformers faster, safer, and more economically than they used to.

1)Always wear the appropriate personal protective equipment including fire retardant clothing, hard hats, safety glasses and rubber gloves. 2)When performing any close inspections of or repairs to the transformer always deenergize the unit and take precautions from any sources of power including customer generators. 3)Prior to re-fusing transformers, make a thorough inspection of the transformer and the surrounding area, looking for indicators such as: animal carcasses, bulged tank or cover, discolored tank, oil leak, burned oil aroma, flashed or broken bushings, any short circuits such as wrapped wires in the secondary or service. 4)Prior to re-fusing transformers, test the transformer with an approved instrument such as a Transformer Turns Ratio tester. Some companies require some form of testing on every transformer before they are energized. 5)When re-fusing a suspected faulty transformer, position yourself as far away as possible by using an extendable live line tool. Some companies specify maintaining a distance of at least 10 ft. when re-fusing transformers. 6)When re-fusing a suspected faulty transformer, always disconnect the customer’s load. 7)Test the transformer with a smaller test fuse. (Some companies have test fuse tables based on the transformer size and voltage). 8)If the transformer blows a fuse and the pressure relieve valve has operated, do not re-fuse and proceed with replacement. 9)If the transformer has an auxiliary current limiting fuse that has blown, do not re-fuse; proceed with replacement. Checking transformer condition 10)Maintain proper distance when re-fusing. In this condition: do not refuse 11)Always make sure the neutral is connected first before connecting a transformer and that it is removed last if disconnecting a transformer. 12)Do not allow the paralleling of transformers across any point that might be used to isolate a line section, such as switches, disconnects and double dead ends to avoid the possibility of back feed into a cleared line section. 13)Always wear rubber gloves when working on the secondary side of a suspected faulty transformer. 14)Take precautions when removing the lid from a suspected faulty transformer by operating the pressure relief valve. If it is an older unit without a valve, tie a sling over the lid before loosing the attachments. 15)Some companies have established step-by-step procedures for investigating transformer problems while others allow the lineworker to access the situation and take precautions they deem necessary within mandatory safety guidelines. 16)It is recommended that step-by-step procedures be developed as they are good training aids and can serve as a refresher for lineworkers. They also help ensure certain key steps are followed Look At the Transformer Complex troubleshooting procedures OR

One-Size-Fits All

How it works Fault occurs Rapid pressure rise IFD activates 3

Application Notes  Expulsion Fuses  Expulsion Fuses with Isolation Links  Expulsion Fuses with Current Limiting Fuses

URD Power Restoration  IFD’s are also effective when used in conjunction with cable sectionalizers and FCI’s.  These devices quickly identify the location of faults in relation to the 2 closest transformers.  The IFD indicates whether the fault is in either of those 2 transformers, or external to them.

 Improve linemen safety  Enable faster and more accurate troubleshooting, and reduce outage times  Keep unfaulted units in service  Prepare for the next generation of linemen The Goals – Use visual internal fault indication to:

Thank you…questions?