COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.

Slides:



Advertisements
Similar presentations
Green Datacenters solution March 17, 2009 By: Sanjay Sharma.
Advertisements

22 electrical Quantities
1 1 BASICS OF ENERGY MANAGEMENT Section A - Energy Basics.
UCSD Medical Center - Hillcrest Campus Case Study Gerry White Facilities Design & Construction University of California, San Diego.
How to lower the energy use of your home David Parker Building Analyst/ Energy Auditor Parker Energy Solutions David Parker Building Analyst/ Energy Auditor.
Columbia University’s Advanced Concepts Data Center Pilot June 17, 2011.
VampirePowerAKA Standby Power Phantom Load Phantom Load or or Leaking Electricity.
Denver Place North & South Towers Case Study Matt Urquhart Amerimar Realty Management Company Jack Wolpert E-Cube, Incorporated.
Topic 7: Electricity in the Home Science 9 with Mrs. M Please take off your hoods and hats Bring a calculator to class next week.
Cooling Product Positioning
PG&E and Altera Data Center Energy Efficiency Project.
Utility-Function-Driven Energy- Efficient Cooling in Data Centers Authors: Rajarshi Das, Jeffrey Kephart, Jonathan Lenchner, Hendrik Hamamn IBM Thomas.
Electrical Energy Use in the Home
CoolAir Temperature- and Variation-Aware Management for Free-Cooled Datacenters Íñigo Goiri, Thu D. Nguyen, and Ricardo Bianchini 1.
Cutting the Green IT Hype: Fact vs. Fiction Kenneth G. Brill, Executive Director Uptime Institute Inc
CNN Center John Hester Turner Properties, Inc.. CNN Center Built in ,583,000 square feet on 18 floors Five structures joined by a common atrium.
Data Centre Power Trends UKNOF 4 – 19 th May 2006 Marcus Hopwood Internet Facilitators Ltd.
So it all boils down to ‘$ and Sense’ No matter what your motivation energy conservation can be argued form both the dollar and sense position.
Spring 2006  Harvard Science, A 52 FHA+MBM Lecture 18, 1 Science A 52 Lecture 18; April 17, 2006 Refrigeration a)Technical background b)Visit to the Chilled.
Saving up to 60% of Energy With The Precision Cooling SmartAisle ™ Configuration.
ENERGY CONSERVATION BUILDING CODE – 2006 PRESENTATION BY VP GUPTA PRINCIPAL CHIEF ENGINEER (ELECTRICAL), BSNL CHENNAI.
Overview of Liquid Cooling Systems Peter Rumsey, Rumsey Engineers.
Data Centers - They’re Back… E SOURCE Forum September, 2007 William Tschudi
Air Conditioning and Computer Centre Power Efficiency The Reality Christophe Martel Tony Cass.
Mission Energy: Energy Efficient Cooling How Data Centre energy consumption and operating costs can be significantly reduced through readily available.
COMP 2923 Basics of Green IT Danny Silver JSOCS, Acadia University.
Data centre air management Case studies Sophia Flucker.
Practical Electricity. Recap…  5 important formulae: Q = Charge (Coulomb) I = Current (Ampere) t = time (second) V = Voltage or potential.
Progress Energy Corporate Data Center Rob Robertson February 17, 2010 of North Carolina.
Day 10 Environmental Systems I Daylight as a primary lighting source Artificial lighting as a secondary source Room 102 Architecture Building.
History a bit. MW/MWe/MWt MWe and MWt are units for measuring the output of a power plant. MWe  MegaWatts of electrical output MWt  megawatts.
Circuits.  Has only one path for electrons to move through.  Current is the same at every point in the circuit  I f = I R1 = I R2  When we add a lamp.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
10 Turn off Lights Not in Use Motion Sensors simple ways to go green
GSM sites Cooling systems description Standard Air Conditioner SystemEmergency Cooling SystemEnergy Saving Cooling System Air Conditioner Cooling system.
Electricity Units and Calculations
Schneider Electric: Total Cooling Solutions for Data Centers
Thermo Scientific has “Gone Green” 2014 MSU Greening the Supply Chain New technologies and processes to reduce the overall energy usage, during manufacturing.
September 26, 2015 Diego Villarreal SHP – Columbia University Introduction to Energy.
Electrical Systems Efficiency Bill Tschudi, LBNL
We can…. 2 GLOBAL REFERENCES Rev: 00 References :
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
Optimizing Power and Data Center Resources Jim Sweeney Enterprise Solutions Consultant, GTSI.
Calculating Energy Use and Converting Units Chapter 2.
Alternative Energy House Mr. Gillespie’s Version.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
Lack of dedicated building meter – Solution: Estimate square footage of Herberger in relation to total area serviced by meter – Estimate 12% of total.
Math for APES Reviewing and Practicing the Energy Math Tuesday, March 8 th, 2016.
EGEE 102 – Energy Conservation And Environmental Protection Energy Efficiency.
InfraStruXure Systems Alex Tavakalov
Data Center Energy Efficiency SC07 Birds of a Feather November, 2007 William Tschudi
WELCOME. Glycol Refrigeration A most basic definition of refrigeration is taking heat from someplace we don’t want it and moving it to someplace where.
SOLAR POWERED AIR CONDITIONER
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
Enabling High Efficient Power Supplies for Servers
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Unit 2: Chapter 2 Cooling.
Book E3 Section 1.4 Air-conditioning
The Data Center Challenge
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Thermal Energy Storage
Closing the Gap to Free Cooling in the Data Center
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Basic Energy Units, Terms and Calculations
Reviewing and Practicing the Energy Math Tuesday, December 13th, 2016
Energy and Power for APES
Did you know? In the U.S. alone, buildings account for: 72% of electricity consumption
Energy Efficiency for the Machine (the Gigafactory) that Makes the Machine March 9, 2018.
HYBRID AIR COOLING TECHNOLOGY
Energy and Power for APES
Presentation transcript:

COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University

References Chapter 8 of The Greening of IT, by John Lamb, IBM Press, Calculating Requirements for Data Centers, by Neil Rasmussen, White Paper #25, American Power Conversion (APC), 2003.White Paper #25

Chilly Facts Breakdown of typical electrical power use in a data centre Power, cooling and lights = 50% of total data center energy use Cooling alone accounts for 37% of energy use Second largest energy cost for data centers – 3 MW IT data center, requires 6 MW power – $5.25M a $0.10 / KWH – 10% reduction in IT load = $260,000 savings – 30% reduction in cooling = $580,000 savings

Background All electrical equipment produces heat Must be removed to prevent failure/fatigue Air cooling is most common approach Heat is energy and is commonly expressed in Joules, BTU, Tons, or Calories Common measures of heat output (power): – BTU per hour – Tons per day – Joules per second = Watts

Background In North America, specifications for power and cooling capability often provided in the legacy BTU and Tons terms Always confusing … world is moving to Watts Conversion to Watts of power (energy / time):

Background The bad news: – Very little energy used to process bits – Most just produces the by-product of heat The good news: – This means that the thermal output of your data center (BTU per hour) = the AC electrical power consumed (Watts)

So What Creates the Heat? IT Equipment UPS – Uninterrupted Power Supply Power distribution system Lighting People

Simple Data Centre Worksheet Excel version of above table.

Question Dalhousie has a 2500 sq. ft data center with a 100KW power supply. There are 400 servers in the data center that use about 150 watts max each. A maximum of 10 people work in the data center. Assume that on average the data center is working at 35% capacity. What is the thermal output of the data center (ie. how many Watts of cooling are needed)?

Question Google has a 10,000 sq. ft data center with a 400KW power supply. There are 1600 blade servers in the data center that use about 40 watts max each. A maximum of 25 people work in the data center. Assume that on average the data center is working at 45% capacity. What is the thermal output of the data center (ie. how many Watts of cooling are needed)?

Thermal Output of a Typical Data Center

Video Cooling a data centerhttp:// f8WqyQPushttp:// f8WqyQPus

Strategies for Increasing Data Centre Cooling Meter your data center energy use (IT, cooling) – You can reduce if you do not measure Bring cooler closer to heat source Properly seal data center Optimizing air flow Use variable capacity cooling systems to increase efficiency Place lights on motion detector switches Turn off chillers in the winter, use outside air

Strategies for Increasing Data Centre Cooling Properly seal data center – Keep all doors closed at all times to maintian cool air and low humidity (should be 40-55%) – Seal all cable openings – Major reason for container approach Optimizing air flow – Goal is to move max air away from equipment – Optimize rack configuration, air conditioner placement, cable management – Use hot and cold aisles

Strategies for Increasing Data Centre Cooling Use economizer and variable capacity cooling systems to increase efficiency – Use outside air in winter months (direct use of cool air, or use of cool air to chill A/C) – Variable number of refrigeration compressors – Digital Scroll compressor technology best

Solutions Fuel cells – replacing backup diesel generators with hydrogen-powered fuel cells Embedded cooling – Liebert XD rack-level method - removes heat before it leaves the rack Chip-level cooling – chips manufactured with cooling systems embedded – Chilled water:

Future Solutions Google Data Centers – Container based – Typical – Amazing floating data centers Facebook Data Center – Put your Data Center in Iceland:

Resources 2011 best practices: bestpractices.pdf bestpractices.pdf