ROOF MATE Step-By-Step Application Over CONCRETE ROOFING

Slides:



Advertisements
Similar presentations
Wetsuit Roofing and Waterproofing
Advertisements

FRIGI-TECH REFLECTIVE ROOF COATINGS. MAIN BENIFITS INSULATES – Outperforms 7 of fiberglass insulation. Keeps interiors cooler and more comfortable. CUTS.
ENERGY STAR Qualified Homes
NGfL CYMRU GCaD FLOOR COVERINGS.
DAY ONE - STEP ONE - Preparation Pure Crete is added to a water truck with a spray bar located at the rear of the truck at a ratio of one gallon to 2000.
DECORATIVE SINGLE COAT PLASTER FOR MARBLE CHIPS CLADDING SYSTEM ( PEBBLEDASH )
Delamination Abdullah AL-Mohaimmeed Definition The act of splitting or separating a laminate into layers. The act of splitting or separating a.
MarineMend Repair Kit Procedure
Civil Engineering Specifications for the Water Industry
SHOTCRETING K.V.SUBBA RAO.
Polyurea Application for Excessively Cracked Concrete
2313 W Sam Houston Parkway N Suite 105 Houston, Texas ROK Shield Application Instructions ROK Shield is a non-toxic,
Flasking ,Wax elimination Packing and Processing
Polymer Floor & Wall Coatings: Selection, Preparation, Installation and Troubleshooting.
2013 C&MS Section 500- Structures Changes from 2010 to 2013 Construction and Materials Specifications in Structures Items.
Ground-Supported Slabs • Exterior Flatwork
Common problems you will find in roofing systems Common problems you will find in roofing systems.
Building Code – Flashing Changes & Challenges Builder Breakfast and Luncheon Series Presented by:
Curing and Protection of Concrete
Blacklidge Emulsions Inc. GuardTop Sealer. Guardtop Mission Statement The goal of Guardtop is to produce an asphalt seal coating that has deeper and longer-lasting.
Fibered Asphalt Emulsion- 10-Year Warranty System.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Concrete Specifications
WORKSHEET 4 CONCRETE. Q1 a) what are the two main properties that concrete must have? (i) strength b) how do we achieve them? by using an acceptable water.
Firestone Building Products EPDM Training. Membrane Attachment.
ROOF MATE Step-By-Step Application Over BOARD-STOCK INSULATION
ROOF MATE Step-By-Step Application Over MODIFIED BITUMEN ROOFING Master Guide Specifications List of materials: ROOF MATE WHITE ROOF MATE BASECOAT ROOF.
A member of Sayegh Group
MAINTENANCE PART 2. Inlet free of obstructions Inlet free of obstructions Adequate scour protection provided.
EXISTING ROOF TOP UNIT. PROVIDE NEW FLASHING AROUND STRUCTURAL PIPE SUPPORTS. 4 2 EXISTING ACCESS LADDER. RE-ADHERE EXISTING BOOT AND SEAM SEAL OVER FLAT.
The Good, the Bad, and the Ugly 2 May 2008 Sacramento, CA Alan Macnab
Prepared by: Marcia C. Belcher Construction Engineering Technology
Asbestos Encapsulation Rust-Oleum Mathys Coatings.
2313 W Sam Houston Parkway NSuite 105Houston, TX77043 (T): (F): ROK Flex C Application Instructions.
AUZIE QUIC SLIP PTY LTD AQS METAL PRO – 001 INTERIOR AND EXTERIOR.
Concrete Construction
CONSTRUCTING A FIVE CABIN LATRINE
VERTICAL/WALL APPLICATION. PRIMING YOUR WALL PRIMER: MAY BE APPLIED DIRECTLY OVER DRYWALL, MASONRY, CONCRETE, CONCRETE BLOCK, OR ICF/STYROFOAM SUBSTRATES.
Coating schemes for different areas Waterproofing of Terrace Application Procedure: General: STEP 4 Clean, dust free surface, ready for application of.
ROOF MATE Step-By-Step Application Over METAL ROOFING Master Guide Specifications List of Materials: ROOF MATE WHITE ROOF MATE BASECOAT ROOF MATE BUTTER.
Unit 26. Sizes 7-5/8” high 15-5/8” long Common depths – 8”, 10”,12” 3/8” mortar joints Walls usually stand 7’-4”
ROOF MATE Step-By-Step Application Over EPDM ROOFING Master Guide Specifications List of Materials: ROOF MATE WHITE ROOF MATE LIGHT GRAY ROOF MATE BUTTER.
Master Guide Specifications List of materials: ROOF MATE WHITE ROOF MATE BASECOAT ROOF MATE BUTTER GRADE ROOF MATE MESH Optional materials: UCC (United.
Intro to Concrete 18.0 & 19.0 Class notes.
Products & Accessories Details System Highlights Hands On
BondChem TECHNICAL DATA Roll-a-crete ( Three Component Cementitious Waterproof Coating ) Page 1 / 2. DESCRIPTION BondChem’s Roll-a-crete is a three component.
TEAM: FIBREX Waterproofing Coating. Introduction  The ASTM Standard defines it is a treatment of a surface to prevent the passage of water under hydrostatic.
LiquiGard ™ Firestone Building Products. LiquiGard ™ About Firestone LiquiGard™ is a tough, liquid applied, two-part polyurethane adhesive. It forms a.
TRENTON Casing Filler Presentation
appseal ® STP Acrylic based elastomeric strip Areas of application: (A) Over Construction joints. (B) Over Expansion joints. 1.
appseal ® XTR Decorative acrylic waterproof coating neha speciality chemicals pvt. ltd. 1.
Silica Fume Inspection
BUILDING CONSTRUCTION ( ) GOVERNMENT ENGINEERING COLLEGE,DAHOD CIVIL ENGINEERING DEPARTMENT PRESENTED BY: PATEL TEJASH S. ( ) GUIDE BY:
2016 SUBSTRATE PREPARATIONS. SUBSTRATE PREPARATION METHODS FOR CONCRETE Very Course Profile Scabbling – Suitable for very aged, weak or contaminated substrates.
Concrete Repair presented by: Amirhossein Jodeiri Mapua Institute Of Tecnology.
Demonstrate Concrete Skills Form A wood or metal structure that confines concrete to the desired shape until it hardens.
Footings & Foundation Prepared By: (Vanani Sanket) Department of Civil Engineering B.H.Gardi College of Engineering & Technology.
Leads Institute of Technology & Engineering
Foundation – jay Desai.
Garland’s White-Knight® Plus/ White-Stallion® Plus System
METHODS OF CRACK REPAIRS
Liquid Flashing: Garland’s Tuff-Flash™ System
CPR™ System.
Revitalizer™ Systems.
Classic TURF Company LLC
DAMP-PROOFING AND WATER-PROOFING COURSE
إختبار وتقييم المنشآت الخرسانية
Tapiflex Self-adhesive
Best Paint Options for a Concrete Around Pool By: Authentic Plastic and Tile
DRY CAST CONCRETE FOR BOXES
Presentation transcript:

ROOF MATE Step-By-Step Application Over CONCRETE ROOFING List of Materials: ROOF MATE WHITE ROOF MATE BASECOAT ROOF MATE BUTTER GRADE ROOF MATE MESH Optional Materials: UNI-CRETE or WALL-BOND UCC (United Cleaning Concentrate) UNISEAL PRIMER UNIBASE ROOF MATE FABRIC RHINO TOP ACRYSHEEN Master Guide Specifications <BACK MAIN MENU NEXT> EXIT

<BACK MAIN MENU NEXT> EXIT ROOF MATE Step-By-Step Over CONCRETE ROOFING STEP 1 – Preparation Remove any dirt, dust, gravel, oil, surface chemicals or other contaminants that may interfere with optimum adhesion. Repair or replace any unsound areas in the roof deck, including deterioration, pitted or spalled concrete, excessive moisture content, etc using a high grade polymer cement, such as UNITED COATINGS’ Uni-Crete or Wall-Bond 70 or 90. Fill any pits or holes with a high strength concrete repair product so they are flush with the surrounding substrate. Ensure that the roof deck has positive slope to drain and that the moisture content of the existing substrate, insulation and deck does not exceed 15%. <BACK MAIN MENU NEXT> EXIT

<BACK MAIN MENU NEXT> EXIT ROOF MATE Step-By-Step Over CONCRETE ROOFING STEP 2 – Cleaning Roof surfaces must be clean, dry, structurally sound and free of excessive ponding water. All Concrete surfaces shall be cleaned using United Cleaning Concentrate (UCC) or comparable biodegradable detergent. Heavy deposits of dirt or contamination may require agitation with a stiff-bristle broom or similar mechanical scrubber. <BACK MAIN MENU NEXT> EXIT

<BACK MAIN MENU NEXT> EXIT ROOF MATE Step-By-Step Over CONCRETE ROOFING STEP 3 – Priming & Details Concrete that is chalky or “punky” after cleaning shall be primed with one coat of Uniseal at the rate of 250 to 300 sq. ft. per gallon (6.1 to 7.3 m²/l) to seal and solidify the surface. All hairline cracks shall be treated with a strip-coat of ROOF MATE Butter Grade, centered over the crack and extending 1” (2.5 cm). Voids or holes larger than 1/8" (3 mm) in width shall be filled and leveled with ROOF MATE Butter Grade. Reinforce all “moving” cracks and/or seams, vertical/horizontal interfaces, roof termination points, openings, around the base of all vents pipes and other protrusions, and around roof mounted equipment using ROOF MATE Butter Grade, or with ROOF MATE Mesh embedded into ROOF MATE Basecoat or Butter Grade. Apply two heavy coats of ROOF MATE Butter Grade with a brush or roller to a total thickness of 60 to 80 mils (1,524 to 2,032 microns). If using ROOF MATE Mesh, apply ROOF MATE Basecoat or Butter Grade liberally around the area to be reinforced. While the material is still wet, embed a strip of ROOF MATE Mesh, centered over the detail, applying additional material to totally encapsulate the fabric. <BACK MAIN MENU NEXT> EXIT

<BACK MAIN MENU NEXT> EXIT ROOF MATE Step-By-Step Over CONCRETE ROOFING STEP 4 – Full Fabric Reinforcement Roofs surfaces that exhibit a high degree of spalling and/or cracking should be detailed by embedding ROOF MATE Fabric into ROOF MATE Basecoat or Unibase over the entire surface. Sandwich the fabric between two coats of ROOF MATE Basecoat, each applied at the rate of 1 to 1½ gallons per 100 sq. ft. (.4 to .6 l/m²). If using Unibase, roll out a 4’ to 10’ (1.2 to 2.5 m) length of fabric and either spray apply or pour Unibase evenly over the top side at the rate of approximately 2 gallons per 100 sq. ft. (.8 l/m²). Work the coating evenly throughout the fabric using a broom or roller so that it is totally encapsulated, eliminating any air pockets, wrinkles or gaps, and allowing the fabric to conform to the surface contours. Overlap consecutive passes of ROOF MATE Fabric a minimum of 2” (5 cm) on each side, taking extra care to ensure that all edges are thoroughly saturated, tight and secure. <BACK MAIN MENU NEXT> EXIT

<BACK MAIN MENU NEXT> EXIT ROOF MATE Step-By-Step Over CONCRETE ROOFING STEP 5 – Coating Application Apply 1 to 4 separate coats of ROOF MATE, using airless spray or roller, at the total rate of 1.6 to 6.2 gallons per 100 sq. ft. (1.3 to 2.5 l/m²), depending on full fabric application, desired warranty and/or specification requirements. Create a self-terminating flashing by extending the topcoat a minimum of 3” (7.5 cm) above all protrusions, parapet walls, etc. <BACK MAIN MENU NEXT> EXIT

<BACK MAIN MENU NEXT> EXIT ROOF MATE Step-By-Step Over CONCRETE ROOFING STEP 6 – Options Apply walk pads, ceramic roofing granules or Rhino Top as required to demarcate walkways and service areas, and/or provide non-skid characteristics. To enhance dirt release characteristics in problem areas, apply a coat of Acrysheen, which imparts a slick, semi-gloss finish that aids in maintaining a clean surface. *Rhino Top is a tough acrylic coating that is available in both smooth and textured formulations. It is ideally suited for horizontal surfaces that receive regular foot traffic. <BACK MAIN MENU NEXT> EXIT

Thank you for choosing quality ROOF MATE products from UNITED COATINGS <BACK MAIN MENU NEXT> EXIT