Wavefront by Method of Ray Tracing: Because the Eye is Not a Telescope

Slides:



Advertisements
Similar presentations
Evaluation of Higher Order Aberrations in Eyes with Dohlman/Boston Keratoprosthesis and Comparison with Penetrating Keratoplasty and Normal Eyes K.Stasi.
Advertisements

Aberrometry and the Tear Film — Understanding new methods —
MYOPIA, ASTIGMATISM, HYPEROPIA… PERSONALIZED TREATMENT Bernard Mathys, MD Secretary-general of the Belgian Society of Cataract & Refractive Surgery.
Customized LASIK & PRK will dominate in next few years
21/09/04www.drmathys.be ESCRS 2004 PARIS Wavefront- and Topography- guided PRK for Myopic Eyes Bernard Mathys, MD Brussels Vision Clinic.
VisTor The new Toric IOL by Hanita Lenses
Refractive Surgery Challenges and their most modern approach D. Alexopoulos MD,DO
RAY TRACING & WAVEFRONT ANALYSIS USING THE TRACEY SYSTEM Donald R. Sanders, M.D., Ph.D. Center For Clinical Research.
Freedom to See Freedom to Be Freedom to Do… Anything You Want.
Quality Control in Refractive Surgery
Optical Aberrations and Aberrometry F. Karimian, MD 2002
INTRODUCTION TO iLASIK TM. It’s Time For The iLASIK ™ Procedure Using a unique combination of the most advanced technology, the iLASIK procedure is fast,
LIGHT AND THE RETINAL IMAGE: KEY POINTS Light travels in (more or less) straight lines: the pinhole camera’s inverted image Enlarging the pinhole leads.
Monovision for Presbyopia Insert name/ Practice name/ Logo here if desired.
Wavefront-Guided Laser Surgery. 2 How the eye works Light rays enter the eye through the clear cornea, pupil and lens. These light rays are focused directly.
Thin Lens Equation Distances of virtual images are negative & distances of real images are positive. Heights are positive if upright (above P.A.) and negative.
Comparison of Early Outcomes of Topo-Guided PRK With Two Refractive Lasers WCC 2015 San Diego, California Simon P. Holland MB. FRCSC,FRCS,MRCP 1, 2, A,
Aspheric IOL’s: clinical benefits and customizing cataract surgery Bojan Pajic, MD, PhD, FEBO Swiss Eye Research Foundation, ORASIS, Reinach, Switzerland.
1 OPTICAL QUALITY OF DUAL- OPTIC ACCOMMODATING INTRAOCULAR LENS Andrea Galvis, MD 1,3 a Ivan Ossma, MD MPH MSc 1,2, a Sanjeev Kasthurirangan, PhD 4, b.
By Kelsey Matthews. History  LASIK stands for laser in situ keratomileusis  Developed in 1991 by a greek doctor Ioannis Pallikaris  Purpose to correct.
Phakic IOL. 2 How the eye works Light rays enter the eye through the clear cornea, pupil and lens. These light rays are focused directly onto the retina,
Laser Vision Correction for Myopia, Myopic Astigmatism, Hyperopia and Hyperopic Astigmatism with CustomVis Solid State Laser (213nm) THE ROYAL AUSTRALIAN.
Refractive Lens Exchange. 2 How the eye works Light rays enter the eye through the clear cornea, pupil and lens. These light rays are focused directly.
Alex P. Lange The author has no financial interest to disclose.
26/11/04 BSCRS Aberrometry in daily practice Bernard Mathys, MD.
Repeatability of Anterior and Posterior Corneal Higher- Order Aberrations in 4 mm, 6 mm and 8 mm diameters measured by Pentacam System Jadwiga Wojtowicz.
Wavefront Sensing of the Human Eye
Accommodative Arching Eyeonics Briefing 2 February 2005 Kevin L. Waltz, OD, MD Eye Surgeons of Indiana Indianapolis, IN.
112/03/2004 Vision-Realistic Rendering: Simulation of the Scanned Foveal Image from Wavefront Data of Human Subjects, Brian A. Barsky, 2004 Gazihan Alankus.
Professor Ioannis Pallikaris MD, PhD.  Different mediums (Nd:YAG Crystals vs ArF Gas)  Less optics for the shaping of the pulse  No use of toxic gasses.
Characterization of Higher Order Ocular Aberrations (HOA) In ‘Normal’ Versus Myopic Eyes To Study The Effect Of Myopia On Higher Order Aberrations Amit.
Outcomes after WIOL – CF accommodative intraocular lens implantation Institute of Vision and Optics University of Crete School of Medicine Heraklion, Crete.
Psych 221/EE362 Applied Vision and Imaging Systems
Comparison of Wavefront and Corneal Aberration Changes after Advanced Corneal Surface Ablation and Femtosecond Thin Flap LASIK Tahra AlMahmoud, MBBS 1,
A Fellow Eye Comparison of Aberrations, Modulation Transfer Function and Contrast Sensitivity After AcrySof IQ and AcrySof Natural IOL Implantation. Mayank.
ASCRS 08 Changes Of Higher Order Aberrations After Excimer Laser Treatment For Moderate Myopia by Means of Preoperative Wavefront Aberration Levels using.
A New Definition of Refraction: Basics and Beyond Austin Roorda, Ph.D. Unversity of Houston College of Optometry.
Integration of Aberrometry and Topography with the i Trace System
Tracey Technologies AAO 2004 Advisors Group Breakfast Tom Padrick, PhD Director of Engineering.
Evaluation of refractive error measurements obtained by three different aberrometers Radha Ram, BA Li Wang, MD, PhD Mitchell P. Weikert, MD, MS Disclosure:
Evaluation Of The Tetraflex and Crystalens Accommodative IOLs Using the iTrace Aberrometer Donald R. Sanders, M.D., PhD. David C. Brown M.D. Deepak Chitkara,
LADARVision4000 Vs VISX CustomVue LADARVision4000 Vs VISX CustomVue CustomCornea CustomCornea A Comparison of Wavefront Guided Refractive Surgery outcomes.
Reproducibility of Optical Measurements in Pseudophakic eyes Using Double-Pass Measurement System St Thomas Hospital, London Anish Dhital, David Spalton,
Refractive Accuracy of LASIK Using the IntraLase and Zyoptix BACKGROUND Wavefront guided customized lasik procedures are designed to correct both lower.
Unwrapping Hartman-Shack Images from Highly Aberrated Eyes Using an Iterative B-spline Based Extrapolation Method Linda Lundstrom & Peter Unsbo Royal Institute.
Analysis of Ocular Wavefront Aberrations in Post Penetrating Keratoplasty Eyes with Two Different Hartmann-Shack Aberrometers Adriana S. Forseto 1, MD;
Correlation of Len Aberrations with Incipient Cataracts Using the Tracey iTrace Visual Function Analyzer by Dr. Paulo Pedri Brazil.
10 year follow up of LASIK surgery for low to high levels of myopia Qasim Qasem FRCS, Caitriona Kirwan MRCOpth, Michael O’Keefe FRCS. Institutional Affiliations:
Ocular functional optical zone following hyperopic LASIK/PRK: Analysis based on polychromatic retinal image quality Mitchell P. Weikert, MD Li Wang, MD,
Financial Disclosure: Medical Director–Galilei R&D Consultant, Ziemer Group AG, Port, Switzerland Consultant & Territory Manager for.
iTrace Dynamic Laser Refraction: Clinical Application
Wavefront-guided Ablation Retreatment in Myopic Eyes Engy M Mohamed MD, Orkun Muftuoglu MD, R.Wayne Bowman MD, V. Vinod Mootha MD, H. Dwight Cavanagh MD,PhD,
25 Optical Instruments Lectures by James L. Pazun Copyright © 2012 Pearson Education, Inc. publishing as Addison-Wesley.
Custom Topographic Neutralizing Technique (TNT) with Topographically-Guided (TG) laser to correct complications David T.C Lin Simon Holland ASCRS 2010.
Toric IOLs: wavefront aberrometry and quality of life Mencucci Rita Giordano Cristina, Stiko Ermelinda, Miranda Paolo, Eleonora Favuzza, Ugo Menchini Authors.
1 REFRACTION OF LIGHT. 2 Chapter 18 Objectives: 1) Define refraction of light including examples. 2) Know which direction a light ray bends as it travels.
CATz for Highly Irregular Corneas after Keratorefractive Surgery Hamed M. Anwar, MD, FRCS Alaa El-Danasoury, MD, FRCS 1 Institutional affiliation: Magrabi.
Laser assisted Corneal normalization in Ectatic disorders
Chapter 25: Optical Instruments
Department of Ophthalmology, University of Ulsan College of Medicine,
Mumbaieyecarecornealasik.com.
Source: Figure 1. Image of colors with their different wavelengths refracted at different angles.
Director: Gulani Vision Institute Jacksonville, Florida
L. Espandar, MD ; M. D. Mifflin, MD; M. Moshirfar MD, FACS
Comparison of vision with an accommodating IOL versus a multifocal IOL
Pharmacological Correction of Presbyopia: A preliminary Study
Conventional LASIK V/S Zyoptix LASIK
Optical Coherence Pachymetry with the ESIRIS DOCTOR EYE INSTITUTE
Mohamed Abdelrahman Awadalla,FRCS Magrabi Eye Hospital Cairo - Egypt
Age-related difference in Lasik Treatment
Presentation transcript:

Wavefront by Method of Ray Tracing: Because the Eye is Not a Telescope Joe S. Wakil, M.D. Chairman, Tracey Technologies, LLC and EyeSys Vision, Inc. Speaker has a Financial Interest

Founding Technology Developers: Vasyl Molebny, DSc Kiev, Ukraine Ioannis Pallikaris, MD Crete, Greece Canadian & Swedish Governments

Why Dynamic Ray Tracing? Because… the Eye is NOT a Telescope! Pupil Size: Accommodation: Tear Film: Effects Refraction (ex. Night Myopia) Refraction is NOT a FIXED Number! Effects Refraction (Instrument Myopia) Effects Quality of Vision (Aberrations) Where are the Sources of Aberrations? How do they change with Surgery? Cornea: Lens: Astigmatism (Irreg.), Sph & other HOA Astigmatism, Coma & other HOA

The Eye is NOT a Telescope Off-Axis design No magnification Variable aperture Variable detector res. Accommodation Changing fixation Brain image processing Nature-made TELESCOPE On-Axis design High magnification Fixed aperture Constant detector res. No accommodation Fixed alignment Digital image processing Man-made

Aberrometer/Wavefront Technologies Hartmann-Shack Lenslet Array Tscherning Aberrometer Differential Skiascopy Ray Tracing Features: -Rapid, point by point, IR measurement - no data confusion -Pupillometry with auto-tracking/capture -Programmable sampling (256 pts.) in any pupil up to 8mm -Open Field Fixation – avoid instrument myopia and measure Accommodation -Corneal Topography integration – able to measure Lens Aberrations -VISX license for Custom LASIK

Hartmann-Shack Wavefront Sensor H/S Photo of patient with tight eye lid courtesy David Williams

Principles of Tracey Programmable thin beam ray tracing measuring forward aberrations of the eye Rapid sequential measurement of data points over entire entrance pupil (<50ms) Localization of each reflected retinal spot Integration of individual retinal spots to form Point Spread Function (PSF) Analysis of PSF for higher order aberrations and other data formats

Data Sample Points Data Sample Points

Multiplying the Number of Sites

Higher Local Density of Sites

Overlay of Two Sets of Site Configuration

Ray Tracing Objective lens Input Beam Retina Eye optics Position sensitive detector

Ray Tracing Objective lens Retina Eye optics Position sensitive detector

Ray Tracing Objective lens Retina Eye optics Position sensitive detector

Ray Tracing Objective lens Retina Eye optics Position sensitive detector

Ray Tracing Objective lens Retina Eye optics Position sensitive detector

Ray Tracing Objective lens Retina Eye optics Position sensitive detector

Refractive Error Measurements Myopia Hyperopia

Retinal Spot Diagram/Point Spread Function

Data Displays Retinal Spot Diagram Refraction Map Ablation Map X, µm 20 10 -10 -20 Y, µm 40 30 Refraction Map Retinal Spot Diagram Wavefront Map Ablation Map

Tracey Analysis Conoid of Sturm Evaluation Contrast Sensitivity Data Depth of Field Analysis Individual Data Point PSF’s Zernike Calculations

Diagnostic Capabilities Determine Higher Order Aberrations True Point Spread Function Presentation Optical Media Opacity Mapping Integrated Corneal Topography

Validation Studies Three independent studies of Tracey vs. Manifest Refraction Koch et al - 58 eyes Slade et al - 42 eyes Schalhorn et al - 106 eyes Results Accuracy to manifest <0.12 D Reproducibility <0.12 D

Post LASIK

Post LASIK

Post LASIK

Keratoconus

Normal

Normal

Accommodating IOL Change due to Accommodation Near Fixation Far Fixation

Advantages of Ray Tracing Aberrometry Combined with Corneal Topography - iTrace Robust dynamic range to measure highly irregular eyes including immediately post-op Multi-Zone Refraction in seconds to measure variations in refraction from normal night myopes to post-op results saving chair time Able to separate Corneal from Lenticular (internal ocular) sources of aberrations with EyeSys Corneal Topography Improved Diagnostic Wavefront to help in patient selection including Custom LASIK and IOL procedures

Conclusion The Tracey iTrace brings a new standard of care in completely assessing vision in terms of quality of vision (aberrometry) and corneal topography to progress visual correction diagnosis and treatments to its ultimate goals.