Technical Operations Manager, Energy - Digital Realty

Slides:



Advertisements
Similar presentations
Challenges in optimizing data center utilization
Advertisements

Energy Conservation Energy Management.
Energy Efficiency – Australias National and International Approach James Shevlin Head, International and Strategies Department of the Environment and Heritage.
IBM Corporate Environmental Affairs and Product Safety
Prior activities of FEWE Under the bilateral and multilateral co-operation, several projects to support the rational energy use in different sectors.
Quality in Energy Management An introduction to ISO A presentation for the CQI, North London Branch Westminster Business School - 25 April 2013 Sarah.
NJ SmartStart Buildings New Jersey Higher Education Partnership for Sustainability (HEPS) January 20, 2012 Presenter: BPU President Robert Hanna.
Smart Devices. Smart Buildings. Smart Business The Potential for DCx Technology Enabled HVAC Operation Scot Duncan, P.E.
September 2012 Energy Opportunities: Solar, Wind, Energy Efficiency.
Maximizing Your IT Budget through Energy Efficiency Heather Feigum Focus on Energy Advisor.
1 Leading Energy Efficiency in High Tech: PG&E’s Program & Service Portfolio Mark Bramfitt, P.E. CSU Dominguez Hills.
Cooling Product Positioning
1 EERMC Public Meeting on Combined Heat and Power September 17, 2013.
Anand Vanchi- Intel IT Ravi Giri – Intel IT Sujith Kannan – Intel Corporate Services Comprehensive Energy Efficiency of Data Centers – Case study shared.
Connecticut’s Energy Future Removing Barriers to Promote Energy Sustainability: Public Policy and Financing December 2, 2004 Legislative Office Building.
State Incentives for Energy Efficiency Commercial and Industrial New Jersey Board of Public Utilities Office of Clean Energy Mona L. Mosser Bureau of Energy.
Performance Contracting The Honeywell One Source Solution.
Energy Audit- a small introduction A presentation by Pune Power Development Pvt. Ltd.
Pacific Gas and Electric Company Energy Efficiency Leadership for Data Centers and IT Mark Bramfitt, P.E. August 5, 2008 Presented to NCCMG Pleasanton,
Creating Energy-Efficient Data Centers
China Thermal Power Efficiency Project WB support to the improvement of coal-fired power generation efficiency in China Jie Tang Energy Specialist East.
Steve Craker K-12 Team Lead Geoff Overland IT and Data Center Focus on Energy Increase IT Budgets with Energy Efficiency.
CNN Center John Hester Turner Properties, Inc.. CNN Center Built in ,583,000 square feet on 18 floors Five structures joined by a common atrium.
1 Enhancing the Role of Renewable Energy in California Robert A. Laurie Commissioner California Energy Commission Geothermal Resources Council Annual Meeting.
Siemens sans siemens sans bold siemens sans italic siemens sans italic bold siemens sans black siemens black italic Siemens Building Technologies.
1 May 12, 2010 Federal Data Center Consolidation Initiative.
PLS WORKSHOP September 18, 2012 Greg Miller Ice Energy Terry Andrews CALMAC Manufacturing Corp.
Energy Management 101 Lance Stewart Facilities Maintenance Manager/Energy Manager City of Charlottesville, Virginia.
Auraria Higher Education Center Case Study John Ismert & Frank Ellis Auraria Higher Education Center Facilities Management.
Best Practices in HVAC Design/Retrofit
Connectivity Week Santa Clara Convention Center May 23, 2011.
Using Service and Product Providers to Leverage Your Energy Efforts Prenova/Owens Corning Energy Process Optimization Thomas Pagliuco – Prenova Fred Dannhauser.
Phoenix Convention Center Phoenix, Arizona Getting Results From Your Energy Projects Session 3Greening the Federal Government Jim Bochat Commissioning.
Working to your advantage. The Vital Link in the Supply Chain Graybar is a leading distributor of electrical, and security products. We help customers.
Demonstrating Sustainable Energy Technologies Michael J. Kelleher Executive Director Energy and Sustainability SUNY College Of Environmental Science and.
Data centre air management Case studies Sophia Flucker.
WORLD ENERGY OUTLOOK OIL & GAS SUPPLY MOEB/D Existing New Actual
Phoenix Convention Center Phoenix, Arizona Solution Showcase GSA’s NDER Program: Doubling the Energy Savings from Financed Projects Kevin Vaughn Schneider.
Phoenix Convention Center Phoenix, Arizona ANDREA L. KINCAID DLA Energy Integrated Energy TrackIntegration of the Energy Industry.
Beyond Mandates, Does Green Pave the Way? Marlene Santos Vice President, Customer Service Florida Power & Light Company October 17, 2009.
Phoenix Convention Center Phoenix, Arizona Data Center Energy Management Strategies Track 7, Session 7 Overview Building Performance Data Center Energy.
“Demand Response: Completing the Link Between Wholesale and Retail Pricing” Paul Crumrine Director, Regulatory Strategies & Services Institute for Regulatory.
Phoenix Convention Center Phoenix, Arizona Facility Energy Audits Mike Gutowski Johnson Controls August 12, 2015 Agency Energy ManagerEnergy Audits: Implementing.
Federal Data Center Programs 7 X 24 Exchange October, 2007 William Tschudi
New York State System Benefits Charge (SBC) – NGA Center for Best Practices April 29, 2004 Bob Callender Vice President for Programs NYSERDA.
Energy-Efficient Infrastructure Management in the IoT era Presented by: George Dritsanos, IT BU VP for Greece, Cyprus & Malta.
Sustainability Elements of the ARRA, and Getting the Most out of Stimulus Funding Jeannie Renne-Malone, LEED AP National Director – Climate Change & GHG.
Rob Boyer Associate, AECOM. Heat Innovation - Changing the way we think about delivering heat Rob Boyer, Associate Director Infrastructure and Sustainability.
1 ITM 1.2 How IT Decisions Impact Data Center Facilities: The Importance of Collaboration Lars Strong P.E. Upsite Technologies, Inc.
Assessing Geopolitical Economics in Securities A panel on the impact of economic and geopolitical forces.
1 PCE 2.1: The Co-Relationship of Containment and CFDs Gordon Johnson Senior CFD Manager at Subzero Engineering CDCDP (Certified Data Center Design Professional)
SETA 2016 : Bangkok Breaking Barriers to showcase the advantages of Energy Efficiency: Cracking the code.
Restricted © Siemens AG 2016 Page 1 Tower to Rack: Driving the Next Generation of Cooling Optimization Technology Jay Hendrix, Siemens Industry Inc. Aaron.
Heat Network Demonstration SBRI: policy context & objectives for the competition Natalie Miles Heat Strategy and Policy (Heat Networks)
West Cambridge Data Centre Ian Tasker Information Services.
Creating A Greener Energy Future For the Commonwealth Clean Heat & Power in Massachusetts John Ballam, P.E. Manager of Engineering & the CHP Program MA.
Energy Solutions for Business Owners Presented by: [Put your name here] Welcome to... Your Logo Here.
Massachusetts Clean Energy Center Budget Overview
Utility Bills Reduction by Energy Consumption Management
Fort Stanwix National Monument Energy Audit Contract
Seminar On Energy Audit Submitted To: Submitted By:
Using Heat to Increase Cooling George Hannah BEng (Hons) CEng MIMechE
© 2016 Global Market Insights, Inc. USA. All Rights Reserved Fuel Cell Market size worth $25.5bn by 2024 Data Center Cooling Market.
The Opportunity for CHP in the United States
Opportunities in the Changing Energy System
Improving Energy Reliability & Performance
Improving Energy Reliability & Performance
State Allocation Board Hearing Solar Energy and Energy Efficiency Project Options for California Schools Mark Johnson, Energy Solutions Manager - Schools.
فایل ارائه حاضر توسط مرکز تحقیقات درایران « اینترنتی از اشیاء» فناوری
Liebert DSE High efficiency thermal management
Presentation transcript:

Technical Operations Manager, Energy - Digital Realty Building Performance Planning, Barriers, Solutions for Data Center Energy Efficiency Project Development Planning, Barriers, Solutions for Data Center Energy Efficiency Project Development John R. Dumler P.E. , C.E.M. Technical Operations Manager, Energy - Digital Realty August 12, 2015 jdumler@digitalrealty.com

Table of Contents Digital Realty Company Overview Better Buildings Data Center Challenge Energy Projects - Planning, Barriers, Solutions Example – Life Cycle Cost Analysis

Digital Realty Overview World’s largest Data Center REIT One of the 20 largest publically traded U.S. REIT’s Equity market cap ~ $9 Billion Diversified portfolio of properties and tenants, located in over 30 markets throughout North America, Europe, Asia and Australia(3) 131 properties 250+ suites (many totally discrete) 24.6 million rentable square feet Recently agreed to acquire Telx Enhanced interconnectivity & Colo offering

Digital Realty Overview ENTERPRISE COLOCATION & CLOUD, MSPS AND SYSTEMS INTEGRATORS NETWORK PROVIDERS

Digital Realty Overview By 2020 U.S. data centers are projected to consume about 140 billion kilowatt-hours of electricity, an amount of energy equivalent to the output of 50 large coal-fired power plants. If all U.S. data centers were 20% more efficient, as a nation we could save more than 20 billion kWh by 2020. That translates to roughly $2 billion in cost savings.

Digital Realty Overview Sustainability Initiatives Clean Energy Green bond Providing clients clean energy for 12 months at no incremental cost over the cost of traditional non- renewable energy. Reduces carbon footprint of client data centers $500 million for “Eligible Green Projects” LEED Data Centers Energy Efficiency Upgrades Water conservation efforts Provisions for lifecycle thinking Global scope

Better Buildings Challenge How is Digital involved? Digital has publically committed to reduce our “non-IT energy intensity”, within a 20MW sub-portfolio of properties, by 20% over 10 years. Digital is one of (20) initial program participants. (13) Public and Federal Data Centers + (7) Private Data Centers Total initial program pledge = 90MW DLR is approx. 22% of total initial commitment. Energy Performance: (22% of goal) Cumulative (vs. Baseline)   4.4% Annual (2014)

Energy Management Program Overview – Process (ISO 50,001) Plan: Conduct the energy review and establish the baseline, key performance indicators (KPI’s), objectives, targets and action plans necessary to deliver results that will improve energy performance in accordance with the customer’s and/or organization's objectives. Do: Implement the energy management action plan(s). Check: Monitor and measure processes and the key characteristics of operations that determine energy performance against the energy objectives, and report the results. Act: Take actions to continually improve energy performance and the overall Energy Management Program.

Energy Management Planning Low/no cost ECO’s – Air and tile management, raising set points, etc. Assess risk 2016-2020 Capital Projects with attractive ECO potential Financial modeling for both ROI and IRR. Attractive utility rebate and incentive availability Customer engagement/interest and support Current or planned connectivity with Digital’s DCIM tool: Envision Cross function buy-in; Customer/IT, Asset Management, Technical Operations, Property Management, Legal, etc.

Energy Management Barriers Utility pass-through Most of Digital’s customers pay 100% of their utility consumption Why Invest in energy upgrades if Digital doesn’t see a benefit? Support customers with in-house energy expertise (whose core business is IT/compute and not data center facilities) Varying financial models for energy conservation opportunities Light speed growth Some customers literally can’t grow fast enough. Energy takes a back seat to growth (and reliability). SLA’s Legacy SLA’s (ASHRAE 2008 Recommended) Narrow temperature and humidity bands – not much wiggle room. Needs to change to facilitate improved efficiency. Resource availability and prioritization – i.e. lack of manpower. Cultural Challenges High awareness, Low implementation “I understand the idea and potential benefits of Energy Management, but….” Raising temps reduces thermal ride through and increases risk. (True? How is this assessed?) Newer IT equipment specs, ASHRAE X-factor, temperature excursions, current air management, etc Who pays for it?

Energy Management Solutions You can’t manage what you don’t measure……i.e. Data…..more is better Gather accurate baseline energy consumption data Understand how and where data is taken and recorded Instantaneous monthly kW values Dedicated vs. Shared infrastructure i.e. accounting for chiller plant energy consumption Re-align legacy designs to accommodate customer IT deployments Average UPS utilization is approx. 35% Tuning Data Center Mechanical Infrastructure to more closely match IT loads. SLA amendments Moving from 2008 recommended to 2011 recommended and allowable (and beyond). Educate, empower and reward individuals Accountability Culture Evaluate opportunities and limitations as they relate to business and customer needs. Identify, Analyze, Prioritize, Implement (Practically)

Energy Management Solutions

Energy Management Example / Case Study

Energy Management Example / Case Study Data Center has (8) 50 Ton CRAH’s @ N+1 = 1230KW Capacity (~350 Tons) IT load was 542kW (~154 Tons) Site requested additional CRAH units because they couldn’t maintain rack inlet temps with 65°F Supply Temp. Site was trying to address hot-spots by deploying high density directional tiles w/o dampers. Findings Backwards switches No blanking panels Improper tile deployment. Too many high density tiles were inadvertently lowering the under floor pressure which was compounding issues. Air volume ~ 232 CFM/kW @100% fan, max cooling = 724 kW (~200 Tons) Stranded Cooling: 506kW (~140 Tons) Fixes Customer modified switches and added blanking panels Dampers were added to high density tiles and tiles were balanced to Rack IT loads with an under floor pressure of approx. 0.05” Results – Fan Savings - With better tile management, under floor pressures rose which caused the CRAH fans to slow down, resulted in $7,000 annual savings Free ’d a large portion of Stranded Cooling Capacity Avoided purchasing and installing new CRAH’s

Energy Management Example SLA All temps are within SLA’s (ASHRAE 2008 TC9.9 recommended ranges) Racks 3 & 10 appears to be a “hot spot”. Why? On average, CRAH/C Return temp set points are between 68°F and 72°F Goal: Get all readings closer to the red band, then increase CRAC/H set points

John R. Dumler, P.E., C.E.M., LEEP AP Technical Operations Manager, Energy M: 770.653.6911 jdumler@digitalrealty.com 375 Riverside Pkwy, Suite 109 Atlanta, GA 30122 www.digitalrealty.com