© BA Electrical Machines - 1 M3000 Ex-motors August 2002 M3000 Low Voltage Motors for Hazardous Areas.

Slides:



Advertisements
Similar presentations
IECEx MEETING IN FORTALEZA, BRAZIL
Advertisements

CE PUWER. Which legislation applies? Which legislation applies? Product legislation Free movement of goods Employment legislation Employee protection.
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
A PPARATUS G AS G ROUPS, T EMPERATURE C LASS AND T YPES OF E XPLOSION P ROTECTION (Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
VSD AND SS DRIVING ATEX MOTORS February Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions.
BA Electrical Machines Insert image here Cast Iron Motors M3000, Status January 2003; What is new in M3BP355 and 400?
TECO Europe Aluminium ALAA IE2 Motors Manufactured in Fuan.
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
Zone 1 & 21 Universal Access Point Enclosure System I Copyright Extronics Ltd Zone1 & 21 Universal Access Point Enclosure System.
Explosion Proof Cameras What is Explosion Proof (EX)? Electric Powered Industrial Equipment, used in areas containing explosive or flammable materials,
ATEX ZONE 2 HAZARDOUS DUTY™ MOTORS
CERTIFICATION OF EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES What do I Really Have to Do ?
Hazardous Location Standards and the CEC
Phare SL Implementation of Technical Regulations on Company Level Breakout session Atmospheres Explosives Low Voltage Electromagnetic Compatibility.
What is ATEX ? The European Regulatory Framework for Manufacture, Installation and Use of Equipment in Explosive Atmospheres Ron Sinclair MBE Chair – IECEx.
CE marking of technical products – bridge to the European market
Low Voltage Directive New Approach. Directive Overview Guidelines on application and Recommendations Safety objectives Documentation LVD standardisation.
© BA Electrical Machines BU Electrical Machines General presentation.
Moeller GmbH page - 1 ATEX. IB ATEX GB Refer to protection notice ISO Moeller GmbH Page - 2 ATEX - HMI-PLC Introduction What is ATEX, and.
Blabo® Automated Tank Cleaning ExxonMobil 2009 Article Electrical standards Designed for operation in hazardous areas. Constructed for zone 1, and some.
Marine Motors Type approved low voltage motors
U D T Workshop on the Pressure Equipment Directive, Warsaw June 2004 INTERFACES BETWEEN NATIONAL LEGISLATION AND DIRECTIVE 97/23/EC SYSTEM OF ENSURING.
Fieldbus 1 FISCO. Fieldbus Certified Transmitter : Intrinsically safe IIC/Group A T4 Ui : 30V Ii : 100mA Ci : 0.01  F Li : 100  H C c : 0.12  F L c.
Phare SL New Approach Directive laying down E.R. to avoid or reduce any risk to health and safety of operators and other exposed persons Risks to.
© BA Electrical Machines - 1 M3000 Cast Iron motors M3000 Aluminium Motors.
Labour Inspectorate Nitra Labour Inspection Authorities Surveillance relating to given manufacturing products Ing. Anton Kasana October 2008.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
The EU Training Programme for Turkish Chamber Executives Electrical equipment Eurochambres Chamber House 19 A/D Avenue des Arts B-1000 Brussels Belgium.
© BA Electrical Machines BU Electrical Machines General presentation.
Fieldbus Accessing all Areas.
S L O V A K I A. Since the 5 th meeting of CEFTA: Important changes have taken place in the Slovak Republic in the following areas: a/ further EC directives.
Basic Awareness Training for all Staff
Arkadiusz Rymanowski Commercial Director.
ENTERPRISE AND INDUSTRY DIRECTORATE GENERAL European Commission 1 ATEX Directive 94/9/EC UNECE WP.6 Break-out session on equipment for explosive atmospheres.
Automation and Drives A&D SD SM1, Hr. Mölter /62 Explosionsschutz_En_02_2004.ppt Standard Drives 3.2Classification of gases and vapors in explosion.
The work of CEN/TC 305 Potentially explosive atmospheres-
© BA Electrical Machines - 1 M3000 Steel motors
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
PowerIT Air Insulated Cubicle Uniswitch
Overview of Ex Regulation in China
Selection of Explosion Protected Equipment for Hazardous Locations
1 Name | Confidential Date Center line content EXPLOSION-PROOF ENCLOSURE MARKET INTRODUCTION PRESENTATION.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
HL-LHC Standards and Best Practices Workshop (11-13 June 2014)
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
TAKE ‘N’ TRAIN ZONEX™ NON-METALLIC TERMINAL ENCLOSURE.
Product Overview. Hazardous & Industrial Enclosures ATEX & IECEx Compliant.
How selected hoist overload limiter. How should hoist overload limiter Selection Electric hoist is a motor, reducer and rope reel (or chain) as one of.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
Standards Certification Education & Training Publishing Conferences & Exhibits ISA SP12 Standards Related to Equipment in Hazardous Locations.
1 ATEX classification air motors, Dagmar Dübbelde ATEX CLASSIFICATION AIR MOTORS.
INDEECO ELECTRIC HEATERS FOR INDUSTRIAL APPLICATIONS
Hazardous Area Timefiller Pt 2
INDUSTRIAL APPLICATIONS
Hazardous Area Environments
Standards Standard "A technical specification or other document available to the public, drawn up with the cooperation and consensus or general approval.
EMC & COMPLIANCE ENGINEERING
Machine-Readable Product Designation
Press “Space” to start presentation
Ron Sinclair Managing Director – Baseefa
IECEx Industry Seminar Integrating IECEx and ATEX for Europe
Thomas Otto, TE Department, CERN
THUM Adapter Impact on Hazardous Area Classification
ATEX fans st ATEX.
ZUMTOBEL KXB 2/36W EVG ZONE 2/ Description
CONSTRUCTION BS (BS 4533) K.F. Chan (Mr.) MEBS 6002.
Mattias Skafar Head of Quality Division
ZUMTOBEL KXB 1/58W EVG ZONE 2/22 DV Description
INTERFACES BETWEEN NATIONAL LEGISLATION AND DIRECTIVE 97/23/EC
installations and assemblies
Presentation transcript:

© BA Electrical Machines - 1 M3000 Ex-motors August 2002 M3000 Low Voltage Motors for Hazardous Areas

© BA Electrical Machines - 2 M3000 Ex-motors - 2 August 2002 M3000 Ex-motors IEC and EN standards Zone 2 /Category 3 in abnormal conditions Zone 1 / Category 2 Occasionally Not suitable for motors Zone 0 Category 1 Continuously Ex nA EEx nA Ex e EEx e Ex p EEx p Ex d EEx d Ex e EEx e Ex p EEx p Ex d EEx d Apparatus groups Group I - Mines susceptible to firedamps Group II - Other places Gas groups (needed only for Ex d and Ex i) IIA (e.g. Propane) IIB (e.g. Ethylene) IIC (e.g. Acetylene and Hydrogen) Zones Zone 0 - continuously Zone 1 - occasionally Zone 2 - in abnormal conditions Temperature classes T1T2T3T4T5T6 450°C300°C200°C135°C100°C85°C

© BA Electrical Machines - 3 M3000 Ex-motors - 3 August 2002 M3000 Ex-motors Marking (EN) EEx - Explosion protected apparatus (Euro Norms) Type of Protection II - Group (other than mines) A, B, C - Gas groups Used only with protection types d and ia/ib Temperature Class EEx d II C T4 Standard marking according to EN-standards II 2 G / D 0081 Gas or Dust Equipment Category (Zone 1) Group of equipment for Surface Use in explosive atmosphere ExNB CE-marking Marking according to ATEX-directive

© BA Electrical Machines - 4 M3000 Ex-motors - 4 August 2002 M3000 Ex-motors Marking (IEC) EEx - Explosion protected apparatus nA - Type of Protection II - Group (other than mines) A, B, C - Gas groups Used only with protection types d and ia/ib Temperature Class Ex nA II T3 T1T2T3T4T5T6 450°C300°C200°C135°C100°C85°C

© BA Electrical Machines - 5 M3000 Ex-motors - 5 August 2002 M3000 Ex-motors ATEX Certified Frame sizes ATEX certified Flameproof Non-sparking Dust ignition proof Increased safety Frame sizes certification ongoing, ready by end of 2002

© BA Electrical Machines - 6 M3000 Ex-motors - 6 August 2002 M3000 Ex-motors Basics of ATEX directive and timetable ATEX-directive (94/9/EC) Compulsory after end of June 2003 Covers all equipment, which will be installed in hazardous area in EU (also non-electrical devices) Requirements are divided in three categories: Technical requirements from harmonised EN-standards Health and Safety aspects Production Quality requirements Timetable ABB delivered the first ATEX certified motor in 02/1999 DirectivesMarkingUntil From /117/EEC, 79/196/EEC and 82/130/EEC 94/9/EC (Atex) Valid

© BA Electrical Machines - 7 M3000 Ex-motors - 7 August 2002 M3000 Ex-motors ATEX directive - Requirements Technical All technical requirement based on harmonised EN standards Harmonisation New EN standards cover all EU countries Health and Safety All requirements focus on safety instructions All equipment must be delivered with instructions for safe: putting into service, use, assembling and dismantling, maintenance, installation, adjustment In practice manuals (in English) and safety instructions (official language of the country and in English)

© BA Electrical Machines - 8 M3000 Ex-motors - 8 August 2002 M3000 Ex-motors EC Declaration of Conformity Directive 94/9/CE (ATEX): The only document which is mandatory to be given with each delivery is: EC Declaration of Conformity. With this document ABB takes the commitment and responsibility that the products respect the ATEX directive. This document gives information on; - product quality assessment notification - EC type examination certificate (with reference numbers).

© BA Electrical Machines - 9 M3000 Ex-motors - 9 August 2002 M3000 Ex-motors Hazardous area motors Frame sizes 71 to 400 Output power 0.25 to 630 kW M3000 concept Variants Flameproof EEx d(e) Increased Safety EEx e Non-sparking EEx nA/Ex nA Dust Ignition Proof

© BA Electrical Machines - 10 M3000 Ex-motors - 10 August 2002 M3000 Ex-motors Flameproof motors EEx d/EEx de IIB/IIC T4 Frame sizes 80 to 400 Output power 0.55 to 630 kW EEx d Motor and terminal box flame proof EEx de Motor flameproof and terminal box of “Increased safety EEx e” -construction

© BA Electrical Machines - 11 M3000 Ex-motors - 11 August 2002 M3000 Ex-motors Increased safety motors EEx e II T3 Aluminium Frame sizes 90 to 250 Output power 1.1 to 53 kW Cast Iron Frame sizes 80 to 400 Output power 0.55 to 330 kW According to EN 50014/50019 VIK (only cast iron) Temperature classes T2-T3

© BA Electrical Machines - 12 M3000 Ex-motors - 12 August 2002 M3000 Ex-motors Non-sparking motors EEx nA/Ex nA II T3 Aluminium Frame sizes 90 to 280 Output power 1.1 to 95 kW Cast Iron Frame sizes 71 to 400 Output power 0.25 to 630 kW Present marking EEx nA acc to EN Ex nA acc to IEC Ex N acc to BS 5000:16 Temperature class T1-T3

© BA Electrical Machines - 13 M3000 Ex-motors - 13 August 2002 M3000 Ex-motors Motors for dust ignition protection (DIP) Aluminium Frame sizes 90 to 250 Output power 1.1 to 55 kW Cast Iron motor Frame sizes 71 to 355 Output power 0.25 to 500 kW Zones 21 and 22 acc. to EN Category 2 D - T125°C - IP65 Category 3 D - T125°C - IP55

© BA Electrical Machines - 14 M3000 Ex-motors - 14 August 2002 M3000 Ex-motors Basic motor design Terminal box Frame Lifting lugs Improved cooling Sealing Bearings Active material Corrosion protection

© BA Electrical Machines - 15 M3000 Ex-motors - 15 August 2002 M3000 Ex-motors Bearings Lubrication Lifetime lubrication sizes Regreasable bearings sizes Sealing 2RS integral seals sizes Gamma ring sizes V-ring sizes Valve disc as standard in sizes

© BA Electrical Machines - 16 M3000 Ex-motors - 16 August 2002 M3000 Ex-motors Terminal box 4 x 90° turnable as standard in sizes and 2 x 180° in sizes Cable glands included in cast iron sizes , except by flameproof EEx d motors Metric threads as standard Easy fastening for separate terminal box

© BA Electrical Machines - 17 M3000 Ex-motors - 17 August 2002 M3000 Ex-motors Rating plate examples IEC IEC Flameproof motors Stainless steel Individual serial number

© BA Electrical Machines - 18 M3000 Ex-motors - 18 August 2002 M3000 Ex-motors Ex-motors and frequency converters Designed for variable speed drive as standard Special attention to be taken: Winding insulation level Bearing insulation Loadability Second rating plate

© BA Electrical Machines - 19 M3000 Ex-motors - 19 August 2002 M3000 Ex-motors Flexible in design Flexible in design for modification of/to Encoders new standard hollow-shaft encoders, Ex-certified Separate cooling same fan as in standard cooling smaller fan and fan motor fan motor Ex-certified