Basic “need-to-know” for Anua Puraflo Bottom draining peat filter systems. Specific requirements for MN applications.

Slides:



Advertisements
Similar presentations
Typical Plumbing System
Advertisements

Drip System Approvals: County Perspective October 19, Onsite Water Conference Anne Lowry, REHS Chatham County Environmental Health.
Wastewater Collection (Sewer Alternatives). Sewer Basics Collection and transport of wastewater from each home/building to the point where treatment occurs.
Treatment of Slaughterhouse Wastewater
Alternatives to Aboveground Effluent Disposal Mounds Overview of the NoMound ® System Technology.
Community Land-Based Wastewater Disposal in Pennsylvania Prepared by: Mr. Brian Oram, PG Wilkes University
Land Use Program Septic System Overview Scott Weldon
WASTEWATER DISPOSAL WITH SUBSURFACE DRIP IRRIGATION Donald R. McDonald AgTech Pacific.
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
Introduction to Septic Tanks John R. Buchanan, Ph.D., P.E. University of Tennessee.
LOADING RATES Sara Heger
GeoMat™ Edge Leaching System Installation Manufactured under one or more of the following U.S. Patents; 7,374,670 7,351,005, 7,309,434, 7,157,011, 6,969,464,
DRIP DISPERSAL SYSTEMS Problems and Solutions. Flow Equalization Surges in the ATU during peak loading are a major cause of filter clogging in a drip.
COLEGIO CRISTIANO AVIVANDO EL FUEGO
Basic Installer Course. AOWA:Basic Installer Course Square foot.
Waste treatment. WASTEWATER (Chapter 22) Sewer – Sanitary waste Generated from buildings –Liquid discharged from plumbing fixtures Carried by sanitary.
Permeable Heavy Use Area for Livestock Farms Presentation for Kitsap County DCD, September 28 th, 2006, Lab Test Findings and Calculated Storm Water Performance.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Rural, Onsite & Small Community Wastewater & Waste Engineering Designing Soil Based Systems.
SEPTIC SYSTEM DESIGN. SEPTIC SYSTEM DESIGN Ken Stratton.
Flow Equalization Tanks Presented by Keith Surface.
The New Mexico Environment Department The Department’s Mission is to provide the highest quality of life throughout the state by promoting a safe, clean,
Catfish Pond Construction Gary Burtle Animal & Dairy Science, UGA Tifton, GA.
Rule Change Update MPCA 1/13/ Mid-Sized ISTS (MSTS)
BOB BROZ UNIVERSITY OF MISSOURI EXTENSION (573) ISE #78 WATER MANAGEMENT STRATEGIES FOR DROUGHT MITIGATION AND SUSTAINABLE AGRICULTURAL PRODUCTION.
Condensation Piping and Installation Drain Pans
Muskegon Wastewater Treatment Facility
GeoMat™ Flat Leaching System Installation Manufactured under one or more of the following U.S. Patents; 7,351,005, 7,309,434,
Well Disinfection Math for Water Technology MTH 082 Lecture
Basic “need-to-know” for Advantex AX-20 pretreatment systems.
Groundwater Math Math for Water Technology MTH 082 Lecture 2 Well Drawdown, Well yield, Specific Capacity, Well Disinfection Course Reader Week 2 Chapter.
SEPTIC SYSTEMS AND WELLS IN SOLANO COUNTY Solano County Environmental Health Division 601 Texas Street, Fairfield CA (707)
Installation. Indoor Unit Installation Typical Installation.
Basic Hydraulics Irrigation.
4.1.6 Student Book © 2004 Propane Education & Research CouncilPage Designing Underground ASME Tank Installations A very important decision in designing.
AccuMax Multi-Point Injection Mechanics
USING THE NEW REGULATIONS DESIGNING OWTS… Prepared for the Colorado Professionals in Onsite Wastewater (CPOW) 2014 Conference by Roger J. Shafer, P.E.
Basic “need-to-know” for MicroFAST pretreatment systems. Specific requirements for MN applications.
Micro Design. System Capacity D = gross application for what ever time period ( hrs, day or days) T= hours in time period used to decide “D” (max.
HVAC523 Basic Subsystems.
CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems.
Chapter 18 Plumbing Plans.
My septic system is working just fine! New State Wide Rules Began 1 st of 2015 replacing the 1977 code Goals Update system designs to currently available.
Preparing Foundations for Cylinders & ASME Tanks
Massachusetts Public Health Inspector Training Wastewater Certificate Program (MA PHIT WW) Session 4: Design and Plan Review— Conventional Systems Part.
Lesson Understanding Soil Drainage Systems. Interest Approach Ask students the question, “What determines how fast water will flow through a funnel?”
Subsurface Drainage (Tile) Design Thomas F. Scherer NDSU Extension Agricultural Engineer (701)
CTC 450 Review 1  WW Characteristics. Objectives 2  Understand the basics of storm drainage systems  Understand the basics of sewer systems.
Unit 209: Drainage systems
RESEARCH AND DEMONSTRATION CENTER ON-LOT SYSTEMS AND SMALL FLOW TECHNOLOGIES DELAWARE VALLEY COLLEGE DOYLESTOWN, PA Project Funding Provided by: Pennsylvania.
Construction of On-Site Stormwater Treatment and Flow Control Facilities Dan Cloak, P.E. Principal Dan Cloak Environmental Consulting.
OWTS Design Considerations Under Reg. 43
Designing DOT Exchange and Stationary Cylinder Installations
Agenda 2015 Installers Meeting
Homeowner Responsibility
RESIDENTIAL PLUMBING SYSTEMS (WASTEWATER)
Staying in Compliance: Spill and Overfill
What is an on-lot sewage system?
Maintenance of the On-Lot Sewage System
BRENT LAWSON STATE PLUMBING INSPECTOR SUBSURFACE WASTEWATER
Private Septic Systems
Vertical Pressure Filters
Typical Plumbing System
Residential Foundations
Private Septic Systems
Presented by: Jon Bellamy
6.1 Configuration of sedimentation tank
Homeowner Responsibility
Wastewater Treatment: Characteristics and Systems
Presentation transcript:

Basic “need-to-know” for Anua Puraflo Bottom draining peat filter systems. Specific requirements for MN applications.

Peat filter Basics The Puraflo peat filter is a single pass media filter system, similar in concept to a single pass sand filter. The typical application is to use the bottom draining pod version to let the treated effluent flow to a drainfield right below the unit. Another option is to collect the effluent at the bottom of the unit and send it to a lift pump for dispersal elsewhere. Puraflo peat filters are Minnesota registered to 150 gpd per pod, assuming residential strength waste. Each of these units will achieve treatment Level “B” without a UV lite. Treatment level “B” only requires 18” of separation to the seasonal high water table and receives an average 25% reduction of the drainfield size. Check the “treatment level B” soil loading rates for your specific soil.

System Layout The basic layout of the bottom draining Peat filter system is similar to a standard pressure bed. To better understand this, a typical layout is shown on the following slides:

The layout of a standard pressure bed system.

To convert to a bottom draining peat filter pretreatment system we simply insert a peat filter on top of the chosen drainfield (pressure bed, at-grade or mound).

Each pod is approximately 7’ long by 2.5’ high by 4.5’ wide and weighs about 1800 lbs (dry)

Basic components and specifications for the Anua Puraflo bottom draining peat filter - Septic tank with effluent filter - Lift tank with Time dosing to the peat filter gpd peat filter pods. - Treatment level B, 18” of separation req’d, and no UV. - Mound, at-grade & bed dispersal options

Treatment process The effluent is micro-dosed to the peat filter by a time dosed control panel. The effluent is treated as it percolates down through the Peat material. It then drains out the bottom of the pod and into the underlying rockbed for final soil dispersal.

Different pod configurations for various uses Noted by a painted circle or triangle on the lid: Blue = bottom draining discharge holes. Green = same as Blue, only now ½ the pod is collected and drains to a sampling chamber. Note: MN product registration states that 1 green pod for sampling is req’d on every system, however code does not require sampling so…? Check with your LUG for proper procedures on this item. White = no discharge holes, all of the pod is collected and drains to a pump tank for dispersal elsewhere.

Design specifications - When mfg design criteria is unclear, MN7080 prevails. - Hydraulic loading rate – 150 gpd residential strength waste - Organic loading rate lbs BOD/day - Septic tank size: design flow /.9 (minimum), or at least 1 days retention time (50% larger septic tank if site contains a garbage disposal). Septic tank to include an effluent filter with 1/32” holes (zabel A300, polylok PL-625, simtech pressure STF-100) - Lift tank size: design flow /.9 (minimum) Realistic recommendation: Surge volume of ½ days flow, Reserve volume ¼ days flow. This leads to about a 1000 gallon tank for 3-4 bedroom system.

Design specifications - continued - Time dosing: approximately 12 times per day, at approximately 10 gpm per pod, at 15 gal per dose (maximum) per pod. (3 bedroom = 3 pods, 450 gpd / 12 doses = 37.5 gal dose at 30 gpm for entire system, this is equal to a 1.25 min ON time) - Bottom draining “pad” system (at-grade or mound style) Limited to sites with less than 10% slopes. If slope >10% you must use a collected drainage system. - The lids are insulated for frost protection, make sure to maintain proper drainback of the supply line to avoid freezing issues.

Design specifications - continued - When using bottom draining pods for dispersal directly to a drainfield rockbed, you will often need more than 1 pod per bedroom. - Maximum pod separation is 5’, or stated another way, each pod is worth 12’ of rockbed length (mounds & at-grades). - # of bedrooms * 12 = total system rockbed length (mounds & at-grades). - The pod can treat up to 150 gpd, but rarely can it evenly disperse 150 gpd. For a mound or at-grade application: the contour loading rate * 12’ = gpd the pod can disperse. ( gpd) For a bed application: 114 ft 2 * level B soil loading rate = gpd the pod can disperse. ( gpd)

Design specifications - mounds Each pod gets credited for a maximum length of 12’ of rockbed along the contour, pods to be evenly spaced with a maximum of 5’ between pods. Contour Loading Rate * 12’ = design flow per pod. (typically 12 gpd/ft * 12’ = 144 gpd) Design flow per pod/1.6 SLR (treatment level B) = rockbed area per pod. (typically 144 gpd / 1.6 g/ft2 = 90 ft 2  12’ long by 7.5’ wide rockbed) 12” minimum sand lift.

Mound elevation - minimum 4’ tall with minimum 12” sand lift (6” to SHWT) - maximum 4.5’ tall with 18” sand lift (0” to SHWT)

Design specifications - At-grade Each pod gets credited for a maximum length of 12’ of rockbed along the contour, pods to be evenly spaced with a maximum of 5’ between pods. Contour Loading Rate * 12’ = design flow per pod. (typically 4 to 8 gpd/ft * 12’ = 48 to 96 gpd) Design flow per pod / SLR (treatment level B) = rockbed area per pod. Range: hi: sand CLR 8, 96 gpd / 1.6 gpd/ft 2 = 60 ft 2  12’ L * 5.0’ W med: sandy loam CLR 6, 72 gpd / 1.0 gpd/ft 2 = 72 ft 2  12’ L * 6.0’ W low: clay loam CLR 4, 48 gpd / 0.6 gpd/ft 2 = 80 ft 2  12’ L * 6.6’ W For at-grades with slopes >1%, the absorption area is measured from the downslope side of the pod. Extra rock upslope may be needed to set the pod on.

At-grade elevation 3’ tall with 18”+ to SHWT

Design specifications - beds Each pod gets credited for a maximum of 114 sqr ft of rockbed, pods to be evenly spaced with a maximum of 5’ between pods spaced either end to end or side to side. Given a 2.5’ perimeter around the pod this leads to a dispersal area 12’ long by 9.5’ wide = 114 ft 2. This area multiplied by the Soil Loading Rate gives the design flow dispersal ability of each pod. Example: A loam soil with a treatment level B soil loading rate of.78 gpd/ft 2 would lead to 114 ft 2 *.78 gpd/ft 2 = 89 gpd of design flow per pod (not 150 gpd). For floatation purposes, the maximum burial depth from original grade is about 18”. Under normal “bottom draining” circumstances you would never bury it more than 6-12” anyway.

Bed elevation maximum 2.5’ tall with 24” to SHWT 2’ tall with 30” to SHWT minimum 1.5’ tall with 36” to SHWT

Design worksheet When designing any system, the simplest method is to find the appropriate design worksheet at and fill it in with the basic field data you obtained from your site evaluation. The design worksheet for a pretreatment system will still only take a couple of minutes to complete purple code Puraflo peat filter (vers 14.2) Property Owner: Date: Site Address: PID: Comments: instructions: = site specific input = adjust if desired = self-calculated (DO NOT ADJUST) 1) ?bedroom Type IV ResidentialSystem 2) 0 GPD design flow(average flow should be < 70% of design flow) PRETREATMENT:(Residential strength to level A/B) 3) 1000Gallon Trash trap/pump tank to Multi-flow 4) 500Gallon Multi-flow unit UV light req'd Yes 30gpm 10ft head TREATMENT pump48doses per day0.0gal /dose (treatment) 5) 10feet of2.0inch supply lineleads to 2gallons of drainback volume 2.0gallons total pump out volume

The design sheet will also produce a System elevation template

Peat filter distribution/lateral configuration - The Pod inlet is at the base and is fed upwards to the distribution laterals. - The Air vents are on the top sides of the lid. - Flow splitting between pods occurs from the pressure equalizing orifice plate in the union at the inlet of each pod. The laterals are actually more of a “pump to gravity” distribution system. The first “perf” is the ½” orifice at the pod inlet, this creates equal pressure between pods, this single large perf then feeds the entire loop lateral system which also contains ½” holes.

Pod Installation (all types) - Scarify soil surface as you normally would any other system. - (For mounds only) apply the appropriate sand lift to obtain adequate separation to SHWT, minimum of 12”. (remember only 18” of separation is needed - Apply 6” of drainfield rock - Set pod(s) on rockbed, evenly spaced, and perfectly flat These pods are heavy and will settle awkwardly if not dealt with accordingly. Compact and rake the rockbed to ensure it is flat. - Connect 2” force main to pods with flex pipe, 1% slope drainback. - If LUG req’d, one pod per system is to contain a sampling chamber (green coded pod). ½ of the pod drain holes are plugged and is diverted into a “bucket” with access via a small riser to grade. Overflow holes near the top of the “bucket” allow it to drain as needed to the rockbed.

Pod and manifold connection (all types)

Force main to extend 6” past last pod and be capped. (recommend a cleanout brought to grade)

Pod installation - continued (all types) - Backfill around pod with 6” of rock to cover supply pipe and pod drain holes. - Cover rock with geotextile fabric. - Backfill as normal to just below insulated lid, sloped to divert water away from pods.

Proper back fill height (to the bottom of the lid)

System summary - The Peat filter pods are registered to treat 150 gpd each, but for bottom draining distribution the design flow is often less. Most likely you will need more than 1 pod per bedroom. - The septic tank is sized as you would a normal system and is required to contain an effluent filter. - The pump tank is time dosed so leave room for surges. A 1000 gallon tank is typical for a 3-4 bedroom application. - No UV lite is required. - The peat material will last about 15 years before it needs replacement. The old media disposed per MN standard abandonment procedures.

System summary - continued MN7080 requires “treatment level B” effluent to be: - uniformly distributed, and - time dosed for all soils except clay and clay loam. The time dosing pressure distribution to the pods meets both these requirements. You must be at least an Intermediate designer to design a residential strength Type IV pretreatment system < 2500 gpd. An operating permit and a management plan are also required.

Components blended in with the natural landscape

This concludes the basic Puraflo peat filter “need to know” training. For further information contact your local distributor or the manufacturer at