DCN Multi CCU System Exercise 5

Slides:



Advertisements
Similar presentations
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC PO ASM Application Software Modules.
Advertisements

Interpreter Desk LBB 3520/10 1. Loudspeaker Volume control (floor)
Security Systems BU Communication Systems ST/SEU-CO 1 DCN MCCU SD Hardware Multi- Central Control Units MCCU System Hardware Basic PC Multi-
Dual Audio Interface Unit LBB 3535/00
Power handling and control capacity
DCN Remote control facilities
Central Control Equipment
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 ApplicationNote MCCU How to install a Multi-CCU system.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 PC Controlled Cam. Control How to configure PC Controlled Camera Control.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 DCN MPCC IO ASM ClientPC Installing the Application Software Modules on the Client.
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
System set up procedure equalizing a system
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA SD Mix-M Mode Mix-Minus Mode  Prevent echo due to this feedback.  Audio-signals,
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 Stand Alone Camera Control How to configure Stand Alone Camera Control.
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA PO TTU Standard Table Top Discussion Units IFU Manual.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC IO ASM Installing all Application Software Modules.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA SD Technology The DCN Technology  Full Digital Audio and Data transport and processing.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN MCCU SD Technology Multi- CCU Channel Handling Discussion / Conference systems  Max.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA SD Insertion Mode Audio routing in Insertion Mode  Open audio path between the.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 DCN MPCC PO MPC Multi PC’s  High Performance PC’s  Microsoft Windows® NT 4.0, 2000.
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 DCN SPPC PO SPC Single PC  High Performance PC  Microsoft Windows®  Direct connection.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA IO Installing Installing a System I&O Manual.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 DCN MPCC SD MPCF Multi PC-Control functionality  Maximum four PC’s in one network.
Security Systems BU Communication SystemsDCN ST/SEU-CO 1 DCN MPCC IO ASM ServerPC Installing and Operating with Multi PC Control.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN MCCU Exercise DCN Multi CCU System Exercise 4 Hands On !
Security Systems BU Communication Systems ST/SEU-CO 1 DCN MCCU PO OS2PC Master PC for Multi- CCU Control  Basic PC  OS/2 Platform  Network.
Security Systems BU Communication Systems Slide 1 DCN NG DCN Next Generation introduction Interpretation system – DCN Next Generation.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
ST/SEU-CO | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA Exercise DCN Stand Alone System Exercise 1 Hands On !
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC SD Technology ACN - Protocol  Maximum Capacity of Translation Channels Audio.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SPCC Exercise DCN Single PC System Exercise 3 Hands On !
Security Systems BU Communication Systems ST/SEU-CO 1 DCN MCCU IO Maintenance Select settings in Maintenance Menu  Default language for the.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA Exercise DCN Stand Alone System Exercise 2 Hands On !
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Security Systems BU Communication Systems ST/SEU-CO 1 DCN SA IO Del Chair Operating of Delegate and Chairman Unit with LCD screen I&O Manual.
Bosch Решения Уникальность Достоинства ST/SUA Maksym Stoyko| | Security Systems © Robert Bosch GmbH reserves all rights even in the event of industrial.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Single CCU System with Control PC and DIRECT Connection
Addressing a Multi CCU System
Central Control Unit (Com - ports) LBB3500/15
Application Software Modules
How to configure Stand Alone Camera Control
Multi CCU Software Startup Screen LBB3586
Multi Central Control Unit LBB 3500/35
How to configure PC Controlled Camera Control
DCNNG Multi CCU System Setup
Presentation transcript:

DCN Multi CCU System Exercise 5 Home Work! 08.12.2004 DCN MCCU Exercise 5

Design a congress system with DCN for: 5.0 Microphone Management and Simultaneous Interpretation with multi CCU. 5.1 All seat positions on the podium with Flush Mounting Units Microphone, Voting, LCD, ID -Card reader, Loudspeaker & Electronic Channel Selector 5.2 Rostrum position with Flush Mounting Units Two Microphones & one Loudspeaker 5.3 All seat positions in the hall with Flush Mounting Units 5.4 Simultaneous interpretation system with 14 languages; minimal two interpretation-desks in each booth 5.5 Central recording of the floor and all translation languages must be possible. 5.6 This system must be able to use in combination with a Application Control PC. 5.7 All the central equipment such as Central Control Unit (CCU), Audio Media Interface (AMI) and Extension Power Supply (EPS) has to be placed in the 19"rack of the technical control room. The way of working (step by step) * Draw into the hall layout all units. * Make the System block diagram. * Make the System Calculation with the DCN Calculation tool. * Make the equipment list 08.12.2004 DCN MCCU Exercise 5

Exercise 5 19" Equipment Rack Technical Control Room Podium 11.. ..20 41.. ..50 71.. ..80 101.. ..110 131.. ..140 161.. ..170 191.. 221.. ..230 200 Chairman Int.'s Booths Int.'s Booths 20m 5m 10m 2m 4m 30m Rostrum 1 8 2 9 3 10 4 11 5 12 6 13 7 14

DCN System Design Exercise 5 End of section  Robert Bosch GmbH All rights are reserved. Reproduction or passing on to third parties in whole or in parts is prohibited without the written consent of the copyright owner. 08.12.2004 DCN MCCU Exercise 5