Presentation is loading. Please wait.

Presentation is loading. Please wait.

Central Control Equipment

Similar presentations


Presentation on theme: "Central Control Equipment"— Presentation transcript:

1 Central Control Equipment
LBB3500/05 LBB3508/00 LBB4106/x0 01.Nov.06 DCN SA PO CCE

2 Central Control Unit (Com - port 1) LBB3500/05
9-pin Sub-D connector RS 232 for: Terminal mode Factory testing Diagnostics OR Camera Control 1 01.Nov.06 DCN SA PO CCE

3 CCU Trunk Communication Board (TCB-4)
1 Jumper X14 for service only 2 S14 DIP- switches 1 – 8 Com-port settings 3 S10 Push- button switch to reset the Central Control Unit during servicing. 4 Three LEDs (left to right) green/ yellow/ red. Normally the green/ yellow LEDs flash in sequence, indicating the software is running. Red LED illuminates during system reset. 5 S9 DIP- switches 1 – 8 System modes 6 Yellow LED indicates Digital Signal Processing (DSP) software is running. 7 Connector for multi- trunk board (used only in the multi- CCU) 8 Sockets for inserting flash EPROM (even) 9 Sockets for inserting flash EPROM (odd) Upgrade Kit 01.Nov.06 DCN SA PO CCE

4 CCU Trunk Communication Board (TCB-4)
10 SRAM back- up battery 3.6 V (life- time 5 years min.) 11 Jumper X13 Battery back up 12 Fuse 3.15 amp (delayed) 13 Connector for multi- trunk board (used only in the multi- CCU) 14 Serial RS232 Port 1 15 Serial RS232 Port 2 Upgrade Kit 01.Nov.06 DCN SA PO CCE

5 Central Control Unit (Com - port 1) LBB3500/05
CCU Protocol and Serial Port settings - Protocol based for using Allegiant Video Switchers. For location of DIP- switches see; Table 4.5 and 4.6 LBB 3500/ 05 Port 1 for Camera Control In a single (stand- alone) CCU system only one COM- port (Port 1) is available: Default settings are; • 8 data bits • No parity check • 1 Stop bit Installation The maximum cable length between the CCU and the ‘Allegiant Video Switcher’ should not exceed 5 m (16.4 ft). Where longer distances are required an ‘current-loop interface unit’ should be used to ensure correct transmission. I&O Manual 01.Nov.06 DCN SA PO CCE

6 TCB-4 DIP Switch Settings
(default) I&O Manual 01.Nov.06 DCN SA PO CCE

7 Central Control Unit (Audio I/O) LBB3500/05
1 2 3 1. Asymmetrical Recorder In- & Outputs 2. 2 Asymmetrical line input connectors 3. Symmetrical or 2 Asymmetrical line outputs 01.Nov.06 DCN SA PO CCE

8 Central Control Unit (Audio I/O) LBB3500/05
1. Tape/cassette recorder input and output (Cinch-type) Tape In Asym. nom. -33 dBV max. -3 dBV Tape Out Asym. nom. -33 dBV max. -3 dBV 2. 2 Asymmetrical line input connectors (Cinch-type) Line In Asym. nom. -18 dBV max. +12 dBV 3. Symmetrical/Asymmetrical line output connectors (Cinch-type) Line Out Sym. nom. -12 dBV max. +18 dBV Line Out Asym nom. -18 dBV max. +12 dBV 01.Nov.06 DCN SA PO CCE

9 Central Control Unit LBB3500/05 (Trunk Outlets)
1 2 Trunk 1. Red LED overload indicators 2. Trunk outlet used for loop-through of the trunk-line-cable 01.Nov.06 DCN SA PO CCE

10 Central Control Unit LBB3500/05 (Trunk Outlets)
PCF = 60 max. PCF = 90 max. Trunk outlets For loop-through of the DCN trunk-line without regenerating the digital signal. Power handling capacity maximum: - 60 PCF per outlet - 90 PCF total for the three outlets of the CCU. 01.Nov.06 DCN SA PO CCE

11 Central Control Unit LBB3500/05
1. Mains socket with built-in fuse Nominal Mains voltage Mains fuse Power Consumption 220, 230, 240 V AC. T- 2A (slow blow) 175 W 105, 115 V, 125 V AC. T- 4A (slow blow) Warning: All units must be powered via an earthed mains outlet. 1 115V-T4A/230V-T2A I&O Manual 01.Nov.06 DCN SA PO CCE

12 Extension Power Supply LBB4106/x0
Rear view 1. Trunk line cable 2. Overload indicators 3. Trunk outlets 4. Mains socket 1 3 4 2 01.Nov.06 DCN SA PO CCE

13 Extension Power Supply LBB4106/x0 (Trunk outlet / Tap-off ’s)
1.Red LED overload indicators 2.Trunk outlet used for loop-through of the trunk-line-cable 3.Tap-off outlets are used for trunk-cable splitting Trunk Tap-off 01.Nov.06 DCN SA PO CCE

14 Extension Power Supply LBB4106/x0 (Trunk outlet / Tap-off ’s)
For loop-through of the DCN trunk-line without regenerating the digital signal. Power handling capacity maximum: PCF per outlet - 180 PCF total for the three outlets of the EPS. Tap- offs For Trunk-cable splitting with regenerating the digital signal. Power handling capacity maximum PCF = 60 max. PCF = 180 max. 01.Nov.06 DCN SA PO CCE

15 Extension Power Supply LBB4106/x0
1. Mains socket with built-in fuse Nominal Mains voltage Mains fuse Power Consumption 220, 230, 240 V AC. T- 4A (slow blow) 350 W 105, 115 V, 125 V AC. T- 5A (slow blow) Warning: All units must be powered via an earthed mains outlet. 1 115V-T4A/230V-T2A I&O Manual 01.Nov.06 DCN SA PO CCE

16 Audio Media Interface LBB3508/00
Rear view 1. Cinch Audio output sockets 2. XLR Audio output sockets 3. Trunk line cable 4. Overload indicators 5. Trunk outlets 6. Mains socket 2 1 5 6 3 4 01.Nov.06 DCN SA PO CCE

17 Audio Media Interface LBB3508/00 (Audio outputs)
1. 4 Asymmetrical Audio output connectors (Cinch-type) 2. 4 Symmetrical (transformer balanced) Audio output sockets (3-pin XLR) Output 1 Output 2 Output 3 Output 4 01.Nov.06 DCN SA PO CCE

18 Audio Media Interface LBB3508/00 (Audio outputs Levels)
4 Asymmetrical audio output Nom Max Interpreter floor & language dBV - 10 dBV Multiple floor and line output dBV dBV Delegate loudspeaker channel dBV + 2 dBV 4 Symmetrical Audio output Nom Max. . Interpreter floor & language dBV dBV Multiple floor and line output dBV +22 dBV Delegate loudspeaker channel +1 dBV +13 dBV 01.Nov.06 DCN SA PO CCE

19 Audio Media Interface LBB3508/00 (Trunk outlet / Tap-off ’s)
1.Red LED overload indicators 2.Trunk outlet used for loop-through of the trunk-line-cable 3.Tap-off outlets are used for trunk-cable splitting Trunk Tap-off 01.Nov.06 DCN SA PO CCE

20 Audio Media Interface LBB3508/00 (Audio outputs)
PCF = 60 max. Trunk outlet For loop-through of the DCN trunk-line without regenerating the digital signal. Power handling capacity maximum: - 60 PCF per outlet - 90 PCF total for the three outlets of the AMI. Tap- offs For Trunk-cable splitting with regenerating the digital signal. Power handling capacity maximum PCF = 90 max. 01.Nov.06 DCN SA PO CCE

21 Audio Media Interface LBB3508/00
1. Mains socket with built-in fuse Nominal Mains voltage Mains fuse Power Consumption 220, 230, 240 V AC. T- 2A (slow blow) 175 W 105, 115 V, 125 V AC. T- 4A (slow blow) Warning: All units must be powered via an earthed mains outlet. 1 115V-T4A/230V-T2A I&O Manual 01.Nov.06 DCN SA PO CCE

22 Central Control Equipment
End of section  Robert Bosch GmbH All rights are reserved. Reproduction or passing on to third parties in whole or in parts is prohibited without the written consent of the copyright owner. 01.Nov.06 DCN SA PO CCE


Download ppt "Central Control Equipment"

Similar presentations


Ads by Google