Unit 208: Central heating systems

Slides:



Advertisements
Similar presentations
Domestic Hot and Cold Water Services
Advertisements

HOT & COLD WATER SYSTEMS
Central Heating (Pipework Only). Forced circulation through loop pipework only Central Heating – One pipe system Central Heating – Types of systems (Part.
Welcome to Energy efficiency for gas-fired and oil-fired domestic heating and hot water systems Session A: Course introduction.
Thermostats, Pressure Switches, and Other Electric Control Devices
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Unit 206: Domestic hot water systems
TYPES OF MECHANICAL SYSTEMS
Unit 206: Domestic hot water systems
Cold feed to hot water cylinder Sink Basin Bath Drain valve Stop valve WC cistern 100 litre (minimum storage cistern)
Unit 205: Cold water systems
Objective of the session.
1 Expansion Tanks. 2 3 Expansion Tanks WHY USE THEM TYPES LOCATION SIZING.
Unit 206: Domestic hot water systems
Filling, purging and air removal
Chapter 6 Thermal Energy
Unit 208: Central heating systems
Section 16.3 Using Heat.
Outcome 2 Materials used to install domestic central heating pipework Unit 208: Central heating systems.
Unit 206: Domestic hot water systems
Unit 206: Domestic hot water systems
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Unit 206: Domestic hot water systems
Lesson One.
POWER PLANT.
Presentation on Installation of a Domestic Cold Water Storage Cistern
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Hydronic Mechanical Controls
PLUMBING Presentation on Central Heating. Forced circulation through loop pipework only Central Heating – Types of systems (Part 1) - One pipe system.
The Cooling System.
Unit 208: Central heating systems
Outcome 3 (part 2) Heat emitters and their components Unit 208: Central heating systems.
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
Plan 2 – Dead-end Seal Chamber Optional Jacket
HVAC523 Basic Subsystems.
Heating Systems.
5.3 Essential Questions What are the first and second laws of thermodynamics? How does an internal combustion engine work? How does a refrigerator work?
Presentation on Feed and Expansion Cistern. Central Heating At the end of this part you should be able to: Identify general system methods of feed and.
Outcome 1 (part 2) Types of domestic central heating systems installed in domestic dwellings Unit 208: Central heating systems.
Zoning Hydronic Systems. Zone Control Divides the Space to be Heated 1.Each with its own heating needs and control systems 2.There are several reasons.
Facilities Management and Design Chapter 7 HVAC Systems.
The Cooling System.
First Law of Thermodynamics  The first law of thermodynamics is often called the Law of Conservation of Energy.
The Cooling System (Reasons for)
HOT WATER Understand and apply domestic hot water system installation and maintenance techniques.
Unit 209: Drainage systems
Boiler Energy Saver Advanced Boiler Controls. Most boiler controls at present consist of a switch!
Boiler Safety Valve Regulations
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Machinery Auxiliary Systems
Chapter 37: Fluid Containment
Section 3: Using Thermal Energy
Outcome 1 (part 1) Types of domestic central heating systems installed in domestic dwellings Unit 208: Central heating systems.
Outcome 3 (part 1) Heat emitters and their components Unit 208: Central heating systems.
Outcome 4 Mechanical central heating controls Unit 208: Central heating systems.
Electrical Gas Plumbing Heating & Cooling
5.3 notes What are the first and second laws of thermodynamics?
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Hot water Systems Heaters.
5508BESG Services and Utilities Lecture 2
Hot Water Systems Cylinders and Systems.
By: JAGDEEP SANGWAN Refrigeration Basics 101.
FBE03: Building Construction & Science
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Boiler Safety Valve Regulations
Presentation transcript:

Unit 208: Central heating systems Outcome 1 (part 1) Types of domestic central heating systems installed in domestic dwellings

Legislation Building Regulations part L: Conservation of fuel and power BS EN 12828: Design of water based heating systems BS EN 14336: Installation and commissioning of water based heating systems BS 4422: Manufacture of radiators CHeSS: Central Heating Efficiency System Specification (basic and best practice)

Legislation Building Regulations part L: Conservation of fuel and power L1a: In new dwellings L1b: In existing dwellings L2a: In new, other than dwellings L2b: In existing, other than dwellings Domestic Heating Compliance Guide

Types of systems The main purpose of central heating is to provide thermal comfort within a property. An open fire gives heat in one room but central heating can give heat in every room. Thermal comfort is attained when the desired heat balance between the body and surroundings is met within the customer’s economic constraints.

Types of systems Full central heating This allows all rooms in a property to be heated at the same time to a specific temperature set by the customer. This comfort temperature must be reached even when the outside temperature is -10C. Selective central heating This allows for some rooms in a property (parts of the property) to be heated at the same time to a specific temperature set by the customer. These rooms would be selected by the customer. This comfort temperature must be reached even when the outside temperature is -10C.

Types of systems Background central heating This can be the same as full or selective but this type of heating is installed mainly on cost basis. A smaller boiler or heat emitters may be used, which will only take the chill out of the rooms and heat the rooms to a lower temperature. If a system cannot achieve the customer’s desired comfort temperature when the outside temperature is -10C, the system would be classed as background heating.

Types of systems Over the past 100 years the open fire in each room has developed and been replaced with: Gravity hot water system Pumped heating with gravity hot water Fully pumped system Central heating is now preferred to an open fire, as it heats up the whole property.

Types of systems This development over the years has seen a change from the use of solid fuel to heat the system, to the use of gas, oil and electricity to heat the system. The customer will be cost conscious, not only at the point of installation, but also with the running costs of the system. Maintenance Efficiency Performance Controls

Types of systems Modern domestic central heating systems fall into two categories, which are based on the way the system is filled with water and the pressure that the system operates at. Low pressure, open vented systems These are fed from a feed and expansion cistern located at high level. These can be fully pumped or gravity systems. Sealed, pressurised systems These are fed directly from the mains cold water and incorporate an expansion vessel to take up the expansion of the heated water. This type of system is a more modern fully pumped or combination boiler system.

Types of systems

Types of systems Gravity or semi gravity systems These are older systems that use convection currents to circulate the water around the pipework. They usually have 28mm primaries associated with solid fuel boilers and the need for convection currents. One pipe semi gravity Two pipe semi gravity C plan semi gravity C plan plus semi gravity system Two pipe semi gravity with heat sink

Types of systems Full gravity systems These systems are no longer installed but you may come across them in older properties. These offer background heating and use large diameter pipework that has to be laid at the correct fall to allow convection to work properly. There was no pump in the system for either hot water or heating, so the heat-up time was lengthy.

Types of systems Primatic systems Old and rarely seen now, but still in use in some older houses, are single feed or ‘primatic’ hot water cylinders. There is no F&E to fill the primary circuit; this is done via the cold feed to the cylinder. Because of this, no inhibitor can be added to this type of heating system. It is a gravity only system and cannot be converted to pumped or the air lock separating the two waters will be lost.

Types of systems One pipe gravity system This is an older but simpler system that consisted of a one pipe circuit going from, and returning to, the boiler. This circuit would be pumped but the flow and return stems to each radiator relied on gravity to heat them up. This meant the installation cost was cheaper due to only one ring pipe being installed. A drawback of this system was: as the return water from each heat emitter entered the main ring, it would cool the flow water down to the following emitter. So, progressively each radiator was cooler than the one before.

Types of systems One pipe gravity system

Types of systems One pipe gravity system Advantages: Cheap to install Disadvantages: Each radiator progressively cools down Only the main ring is pumped Uncontrolled room temperature Boiler could cycle Not compliant to Building Regulations part L Boilers connected to these systems are low efficiency

Types of systems Two pipe semi gravity This system has gravity circulation to the hot water circuit but pumped circulation to the heating circuit. Having separate pipes for the flow and return, water was forced into the heat emitters and the flow and return waters did not mix. This allowed the heat emitters to achieve the same temperature. The control on the heating was sometimes by a room stat, which only witched off the pump. The hot water had no such control and was often very hot.

Types of systems Two pipe semi gravity

Types of systems Two pipe semi gravity Advantages: All heat emitters reach the same temperature Two pipe system is quicker when heating up Cheaper to run Disadvantages: Uncontrolled heat Boiler cycling Not compliant to Building Regulations part L Boilers connected to these systems are low efficiency

Types of systems C plan two pipe semi gravity An updated version of a two pipe semi gravity system that includes a cylinder thermostat and zone control on the hot water. The C plan plus includes a room thermostat, TRVs and zone control on the heating, as well as controls on the hot water. The C plan plus is the minimum acceptable compliant system with Building Regulations part L1b and the Domestic Heating Compliance Guide, which states the system has to incorporate a thermo mechanical thermostat.

Types of systems C plan two pipe semi gravity

Types of systems C plan two pipe semi gravity Advantages: All heat emitters reach the same temperature Two pipe system is quicker to heat up Compliant to Building Regulations L1b Full control on heating and hot water Disadvantages: Not fully pumped Boilers fitted to this system tend to be lower efficiency

Types of systems Two pipe semi gravity with heat sink Used with solid fuels, which are not as controllable as gas or oil boilers. If gravity circulation stops due to the flow and return being the same temperature, the boiler is still producing heat. This can be dissipated through the heat sink without the boiler overheating. The heat sink is generally a radiator with two lockshield valves. The boiler thermostat on a solid fuel boiler is often as simple as an air damper, rather than an electrical control.

Types of systems Two pipe semi gravity with heat sink

Types of systems Two pipe semi gravity with heat sink Advantages: Compliant with Building Regulations part L Disadvantages: Restricted heat control Only used on open vented systems Overheating possible Can be expensive

Types of systems Pumped central heating These are older type systems that do not have any provision for hot water but serve some heat emitters around the property. The cold feed and vent pipe can be taken from the boiler (four tapping boiler) or from the pipework. It is generally a two pipe system with a circulator to assist the heat-up time. The controls consist of a timer, boiler thermostat and possibly a room thermostat, heating all rooms to a controlled, comfortable temperature.

Types of systems Pumped central heating

Types of systems Fully pumped systems These are modern systems that use a pump to circulate the heated water around the hot water and heating circuits. This is controlled by installing a cylinder thermostat, room thermostat and programmer, along with either two zone valves or a three port mid-position valve. These systems offer better control, design and boiler type. The boiler position no longer needs to be lower than the cylinder. Heat-up times are much quicker and therefore make the system more economical on fuel and operating costs. Boilers can be fueled from natural gas, LPG or oil.

Types of systems Fully pumped mid-position valve – Y plan system The three port mid-position valve controls the flow of water to the hot water cylinder and heating circuit. The valve reacts to the room thermostat and cylinder thermostat. The system has an automatic bypass valve, which connects the flow and return pipe. The bypass opens if the system pressure increases when circuits close down due to them reaching temperature. This allows water to flow through the boiler – stopping lock out, and it also prolongs the circulator life.

Types of systems Fully pumped mid-position valve – Y plan system

Types of systems Fully pumped two, two port valves – S plan system This system uses one zone valve to control the hot water, which is activated by the cylinder thermostat; and a second zone valve, which is activated by the room thermostat. The zone valve acts as an isolator, closing the flow of water off. If a property is over 150m2 an additional heating zone valve should be fitted, allowing independent control of upstairs and downstairs. As with the Y plan, an automatic bypass is fitted to the system.

Types of systems Fully pumped two, two port valves – S plan system

Types of systems Y plan S plan Full thermostatic control Building Regulations compliant Recommended for larger properties Can be used with sealed systems Can be used with system boilers Can be zoned Boiler interlock

Types of systems Locking out This is a protection system within a boiler. A thermostat shuts the boiler down if it detects the flow is above 850C and therefore stops it from overheating. Aeration This is a big cause of corrosion within a central heating system. Air plus iron equals rust: rust is iron oxide that produces magnatite, which is the black sludge. Aeration also causes system noise and – in extreme cases – can burn the circulator out.

Air separator To overcome the problem of air being produced as the primary water heats up and then circulating around the system an air separator should be used. Vent Pipe Vent Pipe Cold feed Cold feed Flow to pump Primary Flow Primary Flow

Air Separator

Types of systems Sealed system This system is not open to atmosphere and incorporates a sealed expansion vessel, which replaces the feed and expansion cistern of the open system. A filling connection needs to be installed, along with a detachable filling loop. This allows a point at which the system can be filled under mains pressure. To prevent the possibility of back siphonage of central heating water into mains water, a double check valve needs to be installed. On both of the filling loop connections a means of isolation also needs to be fitted. The Water Regulations clearly state that this loop needs to be disconnected after the system has been charged to the correct pressure.

Types of systems Sealed system A pressure relief valve will need to be installed. This allows the system to discharge pressure to a safe location if required.

Types of systems Sealed system