5.1.? Student Book © 2005 Propane Education & Research CouncilPage 1 Selecting the pump for a propane dispenser should include a complete understanding.

Slides:



Advertisements
Similar presentations
Installing & Testing Regulators
Advertisements

3.4.5 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Pumps, Strainers and Bypass Systems Knowing how to maintain.
7.3.3 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components & Operating Characteristics of Wall Thermostats (Heat.
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
Student Book © 2004 Propane Education & Research CouncilPage Installing Steel Piping in Vapor Distribution Systems Installing steel piping.
3.1.9 Student Book © 2004 Propane Education & Research CouncilPage Replacing Valves and Fittings in ASME Tanks Replacing ASME tank valves and fittings.
3.7.6 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Student Book © 2004 Propane Education & Research CouncilPage Installing Vapor Meters Vapor meters are precision measuring devices that.
2.5 Student Book © 2004 Propane Education & Research Council 2.5 Operating a Truck, Tank Trailer or Tractor/Trailer to Deliver or Relocate ASME Tanks.
2.5.2 Student Book © 2004 Propane Education & Research CouncilPage Examining, Maintaining and Operating ASME Tank Setting Trailers For the safe.
3.7.4 Student Book © 2004 Propane Education & Research CouncilPage Identifying Testing Procedures for Anhydrous Ammonia (NH3) Contamination Because.
4.1.8 Student Book © 2004 Propane Education & Research CouncilPage Selecting Piping and Tubing After completing the gas customer profile and examining.
4.1.9 Student Book © 2004 Propane Education & Research CouncilPage Sizing and Selecting Vapor Meters for Gas Distribution Systems Vapor meters.
3.4.6 Student Book © 2004 Propane Education & Research CouncilPage Maintaining Bulk Plant Compressors Knowledge of the processes involved in maintaining.
3.2.5 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Requalifying DOT Cylinders by CGA External Visual.
2.3.9 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Purging Containers & Injecting Methanol Prior to.
Cycle Stop Valves 1” through 16” 1 GPM to 10,000 GPM.
3.6.2 Student Book © 2004 Propane Education & Research CouncilPage 1 Many propane marketers receive railcar bulk propane shipments. Well-trained personnel.
7.3.2 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Electronic Ignition.
1.1.2 Student Book © 2004 Propane Education & Research CouncilPage 1 A basic knowledge and understanding of propane’s physical properties and characteristics.
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
Student Book © 2004 Propane Education & Research CouncilPage Installing Buried Distribution Lines Using Polyethylene Tubing and Mechanical.
Proper Pump Installation Practices
PEUGEOT 206 INSTALLATION 99’— 05’ TU5JP4
2.3.6 Student Book © 2004 Propane Education & Research CouncilPage Performing a Walk-Around Inspection of the Transport After Loading Performing.
Hydraulic Motors. Objectives 1. Explain the difference in a motor and a pump. 2.Explain the difference in a fixed displacement and a variable displacement.
Student Book © 2004 Propane Education & Research CouncilPage Installing Manifold Cylinders or Tanks When installing manifold DOT cylinders.
4.1.7 Student Book © 2004 Propane Education & Research CouncilPage Selecting Regulators for Vapor Distribution Systems Regulators are mechanical.
4.1.6 Student Book © 2004 Propane Education & Research CouncilPage Designing Underground ASME Tank Installations A very important decision in designing.
Student Book © 2004 Propane Education & Research CouncilPage 1 To provide safe and efficient transporting of bulk containers, such as ASME tanks.
2.5.6 Student Book © 2004 Propane Education & Research CouncilPage Operating a Propane Dispenser to Fill Vehicle-Mounted ASME Tanks To safely and.
5.1.2 Student Book © 2005 Propane Education & Research CouncilPage 1 NFPA 58, LP-Gas Code, sets out the minimum valve and fitting requirements for propane.
3.2.2 Student Book © 2004 Propane Education & Research CouncilPage Performing DOT Cylinder Evacuation and Vapor Flaring Operations Before DOT cylinder.
3.4.2 Student Book © 2004 Propane Education & Research CouncilPage Types and Functions of Valves and Fittings Used in Bulk Plant Containers and.
Hydraulics For The Long Term
4.1 Student Book © 2004 Propane Education & Research Council Layout, Design and Selection of a Vapor Distribution System 4.1.
4.1.5 Student Book © 2004 Propane Education & Research CouncilPage Determining the Proper Corrosion Protection Systems for Underground ASME Tanks.
Student Book © 2004 Propane Education & Research CouncilPage Applying Protective Coatings to Storage Containers ASME tanks require proper.
7.2.4 Student Book © 2005 Propane Education & Research CouncilPage Identifying Procedures for Measuring Current Between Two Given Points in an.
3.7.5 Student Book © 2004 Propane Education & Research CouncilPage 1 A full understanding of the operation of the liquid evacuation process if essential.
Fire Pump Functions The main function of a fire pump is to increase the pressure of the water that flows through it. Inadequate or nonexistent municipal.
5.1.5 Student Book © 2005 Propane Education & Research CouncilPage 1 Specific measures are required by the LP-Gas Code for the prevention of dispenser.
In this module you will learn to:
2.5.3 Student Book © 2004 Propane Education & Research CouncilPage Verifying Proper ASME Tank Condition Prior to Loading For the safe and efficient.
5.1.7 Student Book © 2005 Propane Education & Research CouncilPage 1 Dispensers used to service portable cylinders require suitable scales for filling.
7.2.3 Student Book © 2005 Propane Education & Research CouncilPage Identifying Procedures for Measuring Resistance Between Two Given Points in.
4.2.8 Student Book © 2004 Propane Education & Research CouncilPage Installing Aboveground ASME Tanks Installing aboveground tanks is an important.
3.4.7 Student Book © 2004 Propane Education & Research CouncilPage Examining Bulk Plant Electrical Systems Prevention of gas ignition in transfer.
7.3.5 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Function and Characteristics of Draft Fans & Controls High efficiency.
2.3.8 Student Book © 2004 Propane Education & Research CouncilPage Performing Pre-Unloading Cargo Tank Emergency Discharge System & Delivery Hose.
2.5.5 Student Book © 2004 Propane Education & Research CouncilPage Coordinating Loading and Unloading of ASME Tanks Using Contractor- Operated.
3.7.3 Student Book © 2004 Propane Education & Research CouncilPage Identifying Safe Handling Practices for Flammable and Combustible Liquids Injecting.
Preparing Foundations for Cylinders & ASME Tanks
5.1 Student Book © 2005 Propane Education & Research Council 5.1 Designing & Installing Dispenser Transfer Systems.
5.1.9 Student Book © 2005 Propane Education & Research CouncilPage Installing Propane Dispensers Successful propane dispenser installations are.
Student Book © 2004 Propane Education & Research CouncilPage Reducing Cargo Tank Vapor Pressure Using a Plant Compressor In order to use.
3.4.3 Student Book © 2004 Propane Education & Research CouncilPage Bulk Plant Emergency Shutdown Equipment and Periodic Examination Methods One.
5.1.6 Student Book © 2005 Propane Education & Research CouncilPage 1 Selection of proper dispenser transfer hoses, end valves and adapters relies on a.
Student Book © 2004 Propane Education & Research CouncilPage Performing Gas Distribution System Leak Checks Requirements for vapor distribution.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
3.7.7 Student Book © 2004 Propane Education & Research CouncilPage 1 Replacing DOT IM tank valves and fittings requires careful application of precautions.
3.3.4 Student Book © 2004 Propane Education & Research CouncilPage Operating a Dispenser to Fill DOT Cylinders by Volume DOT cylinders are designed.
4.1.2 Student Book © 2004 Propane Education & Research CouncilPage Determining System Load and Customer Demand Profile Designing a satisfactory.
3.5.6 Student Book © 2004 Propane Education & Research CouncilPage Verifying the Presence of Propane Odorant Drivers and plant unloading personnel.
3.1.8 Student Book © 2004 Propane Education & Research CouncilPage Identifying Procedures for Conducting Container Vapor Flaring Operations Before.
3.6.3 Student Book © 2004 Propane Education & Research CouncilPage 1 Personnel who perform tank car unloading operations must comply with company operating.
Installing DOT/ICC Exchange or Stationary Cylinders
Designing DOT Exchange and Stationary Cylinder Installations
Presentation transcript:

5.1.? Student Book © 2005 Propane Education & Research CouncilPage 1 Selecting the pump for a propane dispenser should include a complete understanding of how the dispenser will be operated, and the functions that the dispenser must fulfill. In this module you will learn to: Applying Propane Pump Operating Characteristics & Selecting the Dispenser Pump 1.Identify the operating characteristics of propane pumps 2.Select the dispenser pump

5.1.4 Student Book © 2005 Propane Education & Research CouncilPage 1 Identifying the operating characteristics of propane pumps Regenerative turbine pumps Courtesy of Corken Pump Div. of IDEX Figure 1. Regenerative Turbine Pump

5.1.4 Student Book © 2005 Propane Education & Research CouncilPage 2 Positive displacement pumps Courtesy of Blackmer Div. of Dove r Figure 2a. Sliding Vane Pump

5.1.4 Student Book © 2005 Propane Education & Research CouncilPage 2 Courtesy of Smith Precision Products Figure 2b. Gear Pump (Coupling Shield Removed for Illustration) Positive displacement pumps

5.1.4 Student Book © 2005 Propane Education & Research CouncilPage 2 Selecting the dispenser pump Dispenser application and operating requirements What containers will be filled? If the dispenser will be primarily used to fill smaller cylinders, with larger containers filled only occasionally, a pump with minimal gallon per minute rating should be selected. The primary consideration in this case is minimizing the risk of over filling small cylinders. If the installation is primarily used to fill larger, vehicle- mounted mobile or motor fuel tanks, a higher volume pump should be considered to reduce filling time and minimize operator waiting that could contribute to lack of attention during the filling operation.

5.1.4 Student Book © 2005 Propane Education & Research CouncilPages 2 & 3 Selecting the dispenser pump Dispenser application and operating requirements What is the expected volume of daily usage? Does the installation location present particular limitations? If the power supply at the site will only support low-voltage, single-phase electric motors, the pump size and volume must be matched to the limitations of the power supply. If site requirements or jurisdictional authority approval mandates the use of a buried or mounted underground supply tank, the pump selection should be made after consulting the pump manufacturer or distributor.

5.1.4 Student Book © 2005 Propane Education & Research CouncilPage 3 Pump rating Manufacturers’ propane pump ratings are generally shown in relation to differential pressure. Differential pressure is the difference between the pressure at the outlet side of the pump and the pressure at the inlet side of the pump.

5.1.4 Student Book © 2005 Propane Education & Research CouncilPage 4

5.1.4 Student Book © 2005 Propane Education & Research CouncilPage 5 Motor Selection Three factors must be known to verify that the explosion- proof motor is appropriate for the dispenser installation and pump: 1.The pump’s horsepower and revolutions per minute (rpm) requirements 2.The installation’s available electrical power supply voltage and phase 3.The motor frame style required; the frame style refers to how the motor is mounted and how the pump is driven by the motor

5.1.4 Student Book © 2005 Propane Education & Research CouncilPage 4 Pump protection devices 1.Proper bypass valve and system Courtesy of Corken Pump Div. of IDEX Figure 3a. For Pumps Up to 40 GPM Figure 3b. For Pumps Up to 80 GPM

5.1.4 Student Book © 2005 Propane Education & Research CouncilPage 5 NOTE: For LP-gas installations, Underwriters Laboratories, Inc. listing and NFPA 58 allow a maximum differential of 125 psig. Courtesy of Dover Corp., Blackmer Pump Div. Figure 4. Automatic Bypass Valve & Adjustment Mechanism If the pump is equipped with an internal bypass (sometimes called a pump “relief valve”), check its pressure setting on the rating plate attached to the pump or in the manufacturer’s IOM instructions. The internal bypass valve pressure must be set according to manufacturer instructions, typically at least psig higher than the external bypass valve setting.

5.1.4 Student Book © 2005 Propane Education & Research CouncilPages 6 & 7 Pump protection devices 2.Verify that a flexible connector for piping stress relief is provided in the pump inlet piping, and if needed, in the pump outlet piping. Figure 5. Stainless Steel Flexible Connector Flexible sections of the proper length must be selected, and should be installed so that they are as close as practical to a straight line. They should never be used in place of pipe fittings to make turns or bends. Improper installation may result in damage to the reinforcement braids and complete failure of the connector.

5.1.4 Student Book © 2005 Propane Education & Research CouncilPage 7 Figure 6a. Improperly Installed Flex Connector Figure 6b. Reverse Side Damage to Stainless Steel Reinforcement Webbing

5.1.4 Student Book © 2005 Propane Education & Research CouncilPage 7 Figure 7. Inline Strainer Body (Note Flow Direction Arrow, L to R) 3.The pump should be protected by the installation of an inline strainer upstream of the pump inlet. Pump manufacturer IOM instructions give strainer screen size specifications for protecting the pump from debris that could damage internal components.

5.1.4 Student Book © 2005 Propane Education & Research CouncilPages Time to See If You Got the Key Points of This Module… Complete the Review on pages 8 & 9. See if you are ready for the Certification Exam by checking off the performance criteria on page 10.