BOILER PLANT OPERATION Presented By Mr. Sivanand Ray

Slides:



Advertisements
Similar presentations
Main Condensate & Feed Systems
Advertisements

CONTROLS OF SUPER CRITICAL BOILERS
Generic Pressurized Water Reactor (PWR): Safety Systems Overview
ACTIVE LEARNING PROCESS
Preventing Equipment Failures
Power Plant Engineering
Fired And Unfired Pressure Vessels
Energy Efficient Steam Systems
Mountings & Accessories
Boilers Dept. of Mech & Mfg. Engg..
Circulating Water System
Objectives Control Terminology Types of controllers –Differences Controls in the real world –Problems –Response time vs. stability.
TYPES OF MECHANICAL SYSTEMS
Basic Refrigeration Cycle
Energy Efficient Steam Systems. Steam Systems Steam systems most widely used type of process heating Advantages of steam: –Heat carrying capacity of steam.
Fuel Oil Burners.
Heating Control Devices
1 Direct Fired Gas Heating Presented by Jim Jagers of Applied Air.
Watertube Boiler.
Thermal Power Station Plant. Introduction 150 MW Thermal power station plant, produce 450t/hr steam at full load The max steam pressure is 150 bar with.
Objective of the session.
THERMAL POWER PLANT.
PLANT DESIGN (I) Prof. Dr. Hasan farag.
Boiler Mountings.
Steam Boilers UNIT-VI.
Steam Power Plant.
References : PartA Ch.2 Sec.2 [5.6] PartA Ch.3 Sec.6 TNS 05 Boiler surveys.
PROJECT AND STUDY DRAWINGS & DIAGRAMS
CHE 185 – PROCESS CONTROL AND DYNAMICS OPTIMIZATION AND PRIMARY LOOP ELEMENTS.
Lesson 7 Steam Power Plant.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam at the desired temperature and pressure.
Lease Automatic Custody Transfer
Gas Turbine Power Plant
HVAC523 Basic Subsystems.
NFPA 31 Standard for the installation of Oil- Burning Equipment
SUBMITED BY BISWAJIT BEHERA
7.3.5 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Function and Characteristics of Draft Fans & Controls High efficiency.
Boiler Mounting Made by : Group 2 Electrical Eng-B.
Presentation Dungrani rakesh v. Div : a Branch : mechenical Sem : 1 st.
Prepared by : Guided by : Mr. Tanmay Patel.
Facilities Management and Design Chapter 7 HVAC Systems.
New Product Developments World Leaders in Combustion Management Solutions Mk7 Expansion PCB Mk7 Expansion PCB.
Boilers Present By: Jason Gillier 4M-H. OBJECTIVE: To provide the audience with a brief, but concise overview of what boilers are and there components.
BOILER MOUNTINGS & ACCESSORIES
BASIC AUTOMATIC CONTROLS UNIT 16 ADVANCED AUTOMATIC CONTROLS
WELCOME TO SHARING SESSION - 3. I NDIAN INTRODUCTION TO IBR R EGULATION B OILER 1950.
Testing Requirements in the Boiler House Requirements for regular testing will vary according to national regulations, and the type of equipment installed.
Boiler Safety Valve Regulations
Thermal power plant , panipat
James McIntyre VRF Training Manager V5 Key Components.
Lesson 7 Steam Power Plant.
Unit 13 Oil-Burning Equipment
Review Questions Chapter 5
Properties and combustion of fuel oils
Control System Instrumentation
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Controllers and Positioners
DELTAK HEAT RECOVERY STEAM GENERATOR
Hot Water Systems Cylinders and Systems.
Power Plant Engineering. Boilers Boilers Boiler is an apparatus to produce steam. Thermal energy released by combustion of fuel is used to make steam.
Rajan Bhandari Senior Lecturer
3. Boiler Mountings Rajan Bhandari.
WATER AND STEAM SYSTEM.
Boiler Safety Valve Regulations
Boiler Room LOG Sheets: Interpreting the Records
Presentation transcript:

BOILER PLANT OPERATION Presented By Mr. Sivanand Ray Fleet Management Training Institute

INSTRUMENTATION USED ON A SHELL BOILER Fire-tube type boiler reviewed for simplicity Instrumentation: Items that provide operator with indication of condition within the boiler Ensure indications are within SAFETY limits and design OPERATIONAL PARAMETERS Operating pressures, temperatures, flows, water level WHAT IS THE PURPOSE OF INSTRUMENTATION? To tell us what is happening INSIDE the boiler. Solid metal so how must we know what is happening! M4-2

INSTRUMENTATION PRESSURE GAUGE Normally Bourdon type of gauge Large with large numbers Graduated approximately double the pressure of safety valve setting, not < than 1,5 Located on top of shell/drum on an independent nozzle Supplied with a siphon (“pigtail”) to develop a water seal Must be calibrated at least once a year A value or test cock should be placed adjacent to the gauge. (1,5”) 40 NB dedicated convection for attaching a test gauge when the boiler is in service. May be located on a gauge board at the remote location, but in this case two pressure gauges required. Must be easily seen and read by operator. M4-3

INSTRUMENTATION PRESSURE TRANSMITTER Where a remote pressure indicator required, an electrical signal used Separate transducer Mounted on same branch as pressure indicator M4-4

INSTRUMENTATION LEVEL COLUMNS Provides VISIBLE water level indication Minimum 25NB pipe line connecting column to boiler TWO water gauge glasses for boiler pressure >28 bar Normally simple gauge glass type Installed such that with lowest reading on gauge glass, 75 mm water over highest point of tubes Visible range of water level approx. 125mm from NWL Daily routine blow down to remove debris, scale, sludge NWL - normal water level Level column - uses electric sensors to give a LED type of display at a remote position. Used on HP boilers Gauge glass - Glass or ‘bulls’ eye type of fixed water gauge glass used on LP and HP boilers. At least 3 or more test cocks per boiler not < 15NB. To be located within visible length of gauge glass. Three general types: Tubular direct reading : Pyrex glass Flat glass transparent : clamped plates Refractive type. M4-5

Typical Water Level Gauge for Low Pressure Boiler At least 3 or more TEST COCKS per boiler. Not < than 15 NB. Test cocks to be located WITHIN visible length of gauge glass. THREE general types off gauge glass : 1. TUBULAR direct reading : Pyrex glass 2. Flat glass transparent : clamped plates 3. Refractive type Typical Water Level Gauge for Low Pressure Boiler M4-6

Electronic and digital water level indicators Used for REMOTE level indicators I.e. where the water gauge glass is distant from the operating level. Electronic and digital water level indicators M4-7

INSTRUMENTATION LEVEL SWITCHES Float type (Mobrey) Single-element control (on-off or modulating) Normally located in an external chamber TWO chambers mandatory Low level alarm Low-low-level shut down Weekly routine test to check correct operation of switches Float movement transmitted by means of a magnetic coupling. M4-8

INSTRUMENTATION TEMPERATURE MEASUREMENT Flue gas exit temperature An increase indicates fouling problems Thermocouples, insulated from gas sampling tube M4-9

TYPICAL PROCESS AND INSTRUMENTATION DIAGRAM (P&ID) COAL FIRED LP BOILER Instrumentation Control loops OIL OR GAS FIRED LP BOILER M4-10

CONTROL AND SYSTEM OPERATING PHILOSOPHY CONTROLS : Regulate the various quantities indicated by the instruments Shut down (with interlocks) the plant if parameters exceeded Manual operation to sophisticated automatic computer operation (DCS) Control relates to a specific system or CONTROL loop as pertaining to a certain system: Controls are diverse and continually developing. This section covers the principles rather than specific details. M4-11

CONTROL AND SYSTEM OPERATING PHILOSOPHY To control a boiler, following quantities require to be regulated : Fuel/air ratio to maintain optimum combustion conditions Water flow to match steam flow from boiler Steam flow and pressure to regulate heat input Combustion chamber pressure (balanced draught boilers) Combustion safety To maintain fuel air ratio, implies the fuel supplied and the air supply should also be measured and controlled; larger HP boilers this is the case. M4-12

COMBUSTION CONTROL Manual control cannot continuously control combustion in a reliable and efficient manner Automatic control systems used : maintains fuel-air ratio to furnace at an optimum maintains a relatively constant steam pressure Combustion control mechanisms vary slightly depending on fuel fired No matter what fuel, four aspects that are regulated: Air supply; Fuel supply; Ratio of fuel to air; Flame safety An operator,performing a MANUAL operation, is unreliable. M4-13

COMBUSTION CONTROL Two basic types of combustion control systems: Positioning Metering Pneumatic or Electrical control drives Positioning : A CHANGE in the steam pressure reading RESULTS in a proportional changes in fuel and air feeds. DETAILS FOLLOW IN NEXT SLIDE M4-14

COMBUSTION CONTROL Positioning Type Control: Designed to control based on a change in steam pressure Components : Master steam pressure controller Fuel control valve with cam for oil / gas or feed control drive for coal Combustion air fan inlet vanes / outlet damper operator Simplistic cannot maintain fuel – air ratio at optimum over full load range M4-15

COMBUSTION CONTROL Metering Type controller : Components as per Positioning type with : Fuel flow measuring device Air flow signal Fuel-air ratio is controlled by a relay Capable of adjusting fuel-air ratio and where fuel pressure may vary REFER TO THE P&ID AS VISUAL. M4-16

General Selection Chart for Combustion Control Systems Type of Fuel Type of Control Steam Generation System Capacity Ranges (kg/hr) Coal Modulating positioning to 27 500 Full metering (Steam /air flow) 18 000 – 36 000 Full metering with Oxygen compensation above 36 000 Fuel Oil & Gas Modulating positioning to 11 500 / air flow) 11 500 – 45 000 Oxygen compensation above 45 000 M4-17

STEAM PRESSURE CONTROL Main purpose of a steam boiler is to produce steam within a definite pressure range Steam pressure dictated by : process plant steam demand heat input to the boiler furnace Pressure fluctuates between minimum and maximum settings Steam pressure primary or major control. Firing rate varied to increase / decrease rate of steam production. More complex systems : burner firing rate modulated based on steam flow and pressure plus combustion air proportioned to the gas flow. M4-18

STEAM PRESSURE CONTROL Modulating control linked to upper and lower pressure limits On-off pressure switch – low or high fire burner Definite limitation exists on burner minimum firing rate turndown ration varies : 4:1 gas; 2:1 oil M4-19

FEED WATER SUPPLY CONTROL Purpose is to provide sufficient feed water flow to ensure all heat transfer surfaces are cooled with water Visible water level provided by : Two simple gauge glasses More sophisticated devices (electrodes, capacitance or conductivity type) Water sensor controls : Normally two independent Float operated Thermostatic Or boiler Water sensor controls : Normally two independent Float operated : simple Thermostatic : automatic, simple, dependable, maintenance neglible. water level control. Float common on ALL small LP boilers and large drum types. M4-20

FEED WATER SUPPLY CONTROL Typical arrangements of feed water plant : Two or more pumps (standby) from hot well tank (10-15 min. storage) Either on-off operation or a feed valve station Feed valve station : Check valve Stop valve Feed control valve c/w isolation and bypass valves Typical arrangements of plant depends on complexity of controller system. With feed water pump and valve station, the feed pump must be supplied with this arrangement, pumps require leak-off devices or pressure relief bypass M4-21

FEED WATER CONTROL SYSTEMS ON AND OFF FEED WATER PUMP Small boilers with relatively large water storage, slow load changes Typical float operated water level controller, mounted at water line Also serves either as low-water level alarm or low water cut off Type of level controller depends on the complexity of the feed water control system. Small volume – steam demand termed :high turnover rate”. M4-22

FEED WATER CONTROL SYSTEMS MODULATING LEVEL CONTROLLERS Boilers with relatively small water volume relative to steam demand Thermostatic type regulator feeds water continuously to the boiler, stabilising the water level THREE types of modulating controllers : Single Element Level Controller Two Element Level Controller Three Element Level Controller SMALL VOLUME implies a steam demand termed “high turnover rate” Single element controller : No flow measurement, only level indication Two Element Controller : As per single but now measure water level and steam flow M4-23

Schematic of Three Element Level Controller Used where several boilers ( 3 or more) supplied by ONE suitably sized pumping system. Feed water flow measured, compared with steam flow signal, compensates of changes in system characteristics M4-24

SOME CONSIDERATIONS REGARDING WATER LEVEL CONTROL Rapid changes in steam flow rate can cause SURGING of the water level and carry-over VERY IMPORTANT that the : steam qualities characteristics of boiler (size, firing system) MUST be properly matched to the OPERATING characteristics of water level controlling system Highest water level, NWL, lowest level for safe operation should be MARKED on boiler outer shell Surging: Steam flow rapidly increases – valve opens suddenly – pressure drops – Sat. temp drops (10 – 15 degrees) – water produces excessive flash steam causing water in boiler to swell up – water level rises i.e. gives false indication to controller and reduces FW flow. Steam temperature drops to lower sat. temp – steam flashing drops – water level drops below NWL – too sensitive control start to open FW flow – surging and carryover. M4-25

FURNACE PRESSURE CONTROL Only really required on coal fired boilers with FD and ID fan Required to : prevent excessive negative pressure and uncontrolled air entering furnace products of combustion to percolate back to coal supply Controller transmitter range not too narrow typically +250 to –1250 Pa ideal control point –100 Pa REFER TO P&ID for COAL FIRED boiler unit : Furnace draft measurement is subject to considerable “noise”. Error signal to either side of ‘set point’ regulates movement damper/vanes on ID fan. M4-26

AUTOMATIC CONTROLS Instrumentation employed same as that for manual operation Rapid and continuous development of electronic control systems means systems for boilers are now DIVERSE Selection shall depend on owner / purchaser present complexity of control systems M4-27

AUTOMATIC CONTROLS ASPECTS that do not vary whether auto/manual : Principles of operation Areas of control (control loops) Direct reading of instruments Safety devices and interlocks Selector for “manual” or “automatic” Selector for “manual” or “automatic” required for system failure or problematic operation. M4-28