1 An Update on Measuring Smoke Plume Opacity Using Digital Camera Methods 2011 NACAA Joint Permitting and Enforcement Workshop June 16, 2011 Bill Gillespie.

Slides:



Advertisements
Similar presentations
Minnesota Registration and Certification (MR & C) History of Electronic systems January 1, 2010.
Advertisements

PRINCIPLES OF A CALIBRATION MANAGEMENT SYSTEM
Welcome to Field2Base User Training. Founded 2002 in Raleigh, NC Software company with focus on automation of field communications 68 patent claims Certified.
CASTLEFORD CAMERA CLUB DSLR Introduction- Session 2 Auto and Manual Modes.
MICROSOFT OFFICE ACCESS 2007.
[Federal Register: June 17, 2003 (Volume 68, Number 116)] [Rules and Regulations] [Page ]
Economics of Pollution Control: An Overview
Exploring Office Grauer and Barber 1 Committed to Shaping the Next Generation of IT Experts. Chapter 2 - Gaining Proficiency Robert Grauer and Maryann.
i Sight1 April 1998 i Sight2 Objective u Present i Sight Company. u Present i Sight Technologies. u Description of technologies. u Status of each technology.
Flexible Software for Computer-Based Problem Solving Labs Brita L. Nellermoe 1 Jennifer L. Docktor 2 1 Department of Curriculum and Instruction 2 Department.
Digitization Projects: Internal Development vs. Outsourcing Production or D.I.Y. vs. The Pros.
Technology Navigator Reports Reporting Solutions for the Financial Institution Industry
Access Tutorial 3 Maintaining and Querying a Database
ONLINE TEACHING PORTFOLIOS FOR TEACHING, LEARNING & PROFESSIONAL DEVELOPMENT: A Mott Community College Center for Teaching and Learning Workshop, presented.
Twenty or so years ago you would be able to buy an all manual camera, for a fairly reasonable price. Adding automatic features would cost a lot more.
Copyright © Texas Education Agency, All rights reserved.1 Introduction to Digital Cameras Principles of Information Technology.
XP New Perspectives on Microsoft Access 2002 Tutorial 71 Microsoft Access 2002 Tutorial 7 – Integrating Access With the Web and With Other Programs.
+ Photoshop – Monitor and Printer Calibration! Drycreekphoto.com.
Kim Garnett Measurement Technology Workshop 2013 January 29-31, 2013.
Source Testing Company Accreditation and Qualified Individual Certification Programs A Status Report Peter Westlin, OAQPS, SPPD, MPG September 13, 2007.
Stork Prints Austria GmbH bestIMAGE 5.60 CAM Plus, CAM smart December 2012 Explore the new features of.
Unit 8 Tim Clouse. Airbrushing Abner Peeler 1879 Photo retouching Photo manipulation Air Paint.
WEB DESIGN Dario Smagata
BritLink 5 Webinar Part 3 Resizing Images. Welcome! “BritLink 5 –Part 3” Hosted by: William Bourne, Britannia System Trainer Please MUTE your telephone.
1 Digital Opacity Compliance System the Next Generation of Opacity Measurements Shawn Dolan /09/2011.
What’s New in Visio 2007 Office Visio 2007 is easy to use and comes with diagram- specific shapes and tools that enable you to quickly create professional-looking.
Software All parts of the computer people can NOT touch, such as programs, files, documents and any other data.
Animation of Sequential Images …through ImageJ Susan Kelly.
Using a Desktop CCTV (Video Magnifier). CTWorks Assistive Technology This presentation is intended to provide information about and how to use the assistive.
Heat Treatment Workshop Infrared Thermal Imaging Products Presented by: Jay Duenow, Regional Manager Raytek Portable Products.
This presentation is the property of Paradigm Information Systems It is confidential to the intended recipient for the purpose of evaluating FMS Any other.
Using your digital camera DIGITAL MEDIA Presented By Andre Daniels.
Aerial Photographic Reconnaissance (APR), Digital Photography, and Web Mission Information Reporting System (WMIRS) Lt Col Dietrich P. Whisennand HQ 4th.
Move Pictures From Your Mobile Phone to Your PC.  You never know when a photo opportunity is going to arise, which is why having a camera phone can be.
Introduction to ArcGIS for Environmental Scientists Module 1 – Data Visualization Chapter 1 – GIS Basics.
Tribal Air Quality “Tools of the Trade” Lydia Scheer, ITEP.
Presented For: MoanaCo March 1, 2013 NaluHou Product Overviews Defining Standard Application Defining Cloud Computing Microsoft Office 2010 vs. Google.
FAMILY AND CHILDREN’S TRUST FUND (FACT) RESEARCH AND DATA MATERIALS.
Karen Herter (HMG) Mike Langley (DGS) April 15, 2008 Portfolio Manager for California State Buildings Meeting the Requirements of Executive Order S
Manipulate Graphics Skill Area Lecture Overview Photoshop’s GUI Basic Function Basic Image Manipulation.
Digital Photography and photo manipulation Richard Hine.
TUTORIAL 9 INSTRUCTOR: HANIF ULLAH ID: OFFICE #: 2029 DATE: 22/04/2012 Introduction to MS Project 2007.
1 An Evaluation of a Digital Camera System for Measuring Smoke Plume Opacity EPA Measurement Technology Workshop 2013 January 29, 2013 Bill Gillespie Virginia.
Capabilities of Software. Object Linking & Embedding (OLE) OLE allows information to be shared between different programs For example, a spreadsheet created.
COMPREHENSIVE Access Tutorial 3 Maintaining and Querying a Database.
1 OGM Presentation for Your Hospital Today. 2 The Ongoing Maintenance Program The OGM Program Components.
Title V Operating Permits: A Compliance and Enforcement Tool Candace Carraway US Environmental Protection Agency Office of Air Quality Planning and Standards.
Adobe Photoshop CS5 – Illustrated Unit A: Getting Started with Photoshop CS5.
Welcome! Users, Groups, Project Templates, and Custom user-defined search fields.
LEADS/EMS DATA VALIDATION IPS MeteoStar December 11, 2006 WHAT IS VALIDATION? From The Dictionary: 1a. To Make Legally Valid 1b. To Grant Official.
Simple data visualizations Tech Fest why bother? long history of using pictures to show significance of numbers increasingly “visual” society visual.
PI in a Modern Power Plant – American National Power, Inc. PI User Conference ‘03 Presented by: Brian M. Wood, American National Power, Inc More Uses Than.
Scanners. Using a Scanner Scanners are used to digitize any flat object. Several types of scanners- flatbed, sheet fed, handheld, film. Most common is.
Digital Photography From start to finish. Choosing a digital camera: speed Digital cameras have more “lag time” during and after shots. Pre-focusing (press.
Toolkit E Option 4 Staff Development By: Michele Linn.
Photoshop Actions Lights, Camera, Actions in Photoshop.
PHOTOGRAPHY. Knowing your Digital Camera Important Considerations Megapixels / Resolution (3MP, 4MP or >4MP) Image quality and format Zoom (1X, 2X, 5X.
STREAMLINING STORM WATER PERMIT IMPLEMENTATION THROUGH USE OF AN INFORMATION MANAGEMENT SYSTEM April 8, 2004 Presented by John W. Hart 30 th Environmental.
The Challenge of Measurement Interoperability A certification program for metrology consultants and technicians Authors: J. Salvador Echeverría Villagómez.
Understanding Images. Pixels pixels Every image is made up of very small squares called pixels, and each pixel represents a color or shade. Pixels within.
Photoshop CS6 – Nelson Unit 3: Photoshop CS6. Objectives Define photo editing software Start Photoshop and view the workspace Use the Zoom tool and the.
Digital Opacity Compliance System Second Generation
Getting Started with Adobe Photoshop CS6
Computing Fundamentals
A computer display is made up of small squares, called pixels.
Michael J. McFarland (Utah State University)
Lesson 5 Computer-Related Issues
CHOOSING A DIGITAL CAMERA FOR YOUR CLASSROOM AND PERSONAL USE
Tutorial 7 – Integrating Access With the Web and With Other Programs
A New Tool for Evaluating Candidate PM FEM and PM2.5 ARM Monitors
Presentation transcript:

1 An Update on Measuring Smoke Plume Opacity Using Digital Camera Methods 2011 NACAA Joint Permitting and Enforcement Workshop June 16, 2011 Bill Gillespie Virginia Department of Environmental Quality Northern Regional Office (703)

2 Presentation Topics EPA’s approval of ASTM D How the new ASTM method works Some “pros and cons” of the new method Practical problems associated with the new method Areas where EPA, state and local agencies, and others can support and improve the method

3 EPA’s Approval of a New Method for Determining Plume Opacity On April 13, 2011, EPA issued “broad approval” of ASTM D ASTM is the American Society for Testing and Materials ASTM D is a Standard Test Method for Determining the Opacity of a Plume in the Outdoor Ambient Atmosphere The ASTM method is available (for $55) at:

4 Quick Summary of the New Method The new ASTM method is: “Method 9 with a digital camera as the sensor.” The method requires: –A digital camera –Analysis software –A trained operator The EPA approval letter places some additional requirements on the method. See:

5 Some Implications of EPA’s Approval of the New Method Broad approval means the ASTM method can be used in lieu of Method 9 when opacity determinations are performed under any subpart to 40 CFR 60, 61, and 63 for ducted emission sources. EPA and state and local agencies may begin receiving opacity determinations based on the new method. EPA and state and local agencies have a new way to evaluate smoke plume opacity.

6 EPA Staff Involved in the Approval of ASTM D OAQPS Measurement Technology Group Staff Jason M DeWees USEPA/OAQPS/AQAD/MTG; Research Triangle Park, NC; (919) Robin Segall, USEPA/OAQPS/AQAD/MTG; Research Triangle Park, NC; (919)

7 How the new ASTM method works

8 The Camera The method does not specify any particular camera or camera type. The camera must be capable of operating in: –Default auto focus mode –Default auto-exposure mode The camera must be able to generate EXIF 2.1 JPG (or higher) formatted output files. Optical zoom is allowed. Digital zoom is not allowed. EXIF = Exchangeable Image File Format

9 Photographing the Plume Position yourself as you would for Method 9. Position yourself to maximize the contrast between the plume and its background. Turn off digital camera features such as: flash, optical filters, digital zoom, image stabilization. Do not photograph steam…. Center pictures on the plume observation point. Take JPEG images every 15 seconds.

10 Analyzing the Photographs Download the photographs to a PC. Analyze the photographs with software. –Compare “in the plume” areas to “background areas” adjacent to the plume. –The difference between “in the plume” values and “out of the plume” values is correlated to opacity.

11 Analyzing a Photograph Photograph Courtesy of Eastern Technical Associates, Inc. In plume dataBackground data

12 Before Field Work, the Camera, Software & Operator Must Be Certified

13 Some “Pros and Cons” of Method 9 and the new ASTM method

14 Some “Pros and Cons” of Method 9 and the New ASTM Method Method 9ASTM D A well established method. State & local inspectors are familiar with the method. Method is new and relatively unknown. Method is very similar to Method 9, however. Tested in the courts.Not tested in the courts. Requires an initial one day of training & certification testing every 6 months thereafter. Requires 3 to 5 days of training & camera certification every 3.5 years. Requires minimal equipment.Requires a camera, software & PC. Relies on the human eye for opacity measurement. Relies on a camera and analytical software for opacity measurement. Provides little post-observation data or evidence. Provides excellent post-observation data and evidence. A picture is worth… Appropriate for any size stack. Not applicable to stacks greater than 7 feet inside diameter, but this may soon change. Some staff strongly dislike Method 9 certification training. Staff have expressed an interest in this method.

15 The squares marked A and B are the same shade of gray. Courtesy of Edward H. Adelson, MIT Visual Methods Can Yield Poor Results…

16

17 Digital camera methods hold promise as good, objective analytical methods for evaluating smoke opacity….

18 Some Practical Problems Associated with the New Method

19 Some Practical Problems Associated with the New Method (1 of 2) The only commercially available software to analyze photos for the ASTM method is: DOCS II from Virtual Technology, LLC DOCS II is sold as a package for $5,995 and includes: camera, PC, software & the usual Method 9 equipment. Many states and local agencies just want good, reasonably priced software. (They already have cameras, PCs and Method 9 gear….)

20 Some Practical Problems Associated with the New Method (2 of 2) Commercial interests appear to be strongly influencing/controlling method development… Sean Nolan, President of Virtual Technology, LLC leads the Work Group developing the ASTM method. Virtual Technology LLC and Eastern Technical Associates, Inc. (a smoke school company) are marketing DOCS II.

21 Free Software May Allow State and Local Agencies to Analyze Photos ImageJ software from the National Institute of Mental Health is a tool state and local agencies might be able to use to analyze digital photographs. DEQ is exploring whether ImageJ software can be used calibrate & certify digital cameras for the ASTM method. ImageJ software is available at: Software specifically designed to analyze smoke plumes would be a better solution….

22 Areas where EPA, state and local agencies, and others can support and improve the method

23 Get involved with the ASTM Workgroup. Try the new method. Fund the development of software that: –Is easy to use. –Runs well in the Windows environment. –Provides intermediate results for user QA. –Has good documentation so agencies know exactly how the software arrived at its answer. Funding could come from EPA, S&Ls, SEPs,… What EPA & State & Local Agencies Can Do to Support the New Method

24 References EPA Method ASTM’s Digital Camera Opacity Technique (DCOT) DOCS II by Virtual Technology LLC ImageJ software is available at:

25 Disclaimer The views expressed in this presentation do not reflect the official views, policy or position of the Commonwealth of Virginia.