1 Simulations and experimental verification of medical X-ray sources: CT case R. A. Miller C. Department of Biophysics, Medical Biophysics Centre University.

Slides:



Advertisements
Similar presentations
Radiation biology and protection in dental radiology
Advertisements

Technique Guidance Systems
CT Scanning: Dosimetry and Artefacts
Image Reconstruction.
CT Organ Dose - Part 1 Estimating organ dose for patients Michael F. McNitt-Gray, Ph.D., DABR David Geffen School of Medicine at UCLA.
Formation Characteristics
Improved Conspicuity of Abdominal Lesions with Single-Source Dual-Energy MDCT Hadassah Hebrew University Medical Center Jerusalem, Israel Ruth Eliahou.
IMAGE QUALITY.
Topic 3 Selection of kV High kV scattered radiation is energetic. Angle of rays is same as those of primary beam and is not deflected very much. Follows.
Computed Tomography II
Seeram Chapter 13: Single Slice Spiral - Helical CT
RAD309 Patient Dose.
NC HPS Meeting 10/18-19/2001 Boone, NC Recent Advances in CT Technology and Issues of CT Dosimetry T. Yoshizumi 1,2, M. Sarder 1, R. Reiman 1,2, E. Paulson.
1 NEXT 2000: Survey of Computed Tomography (CT) Practice, Workload, Dose Stanley H. Stern, Ph. D. FDA/CDRH Office of Health and Industry Programs Division.
5 th September 2005 Paul Collins Computed Tomography Dosimetry Assessment of Effective Dose in Computed Tomography using an Anthropomorphic Phantom Paul.
CT Multi-Slice CT.
IMAGE QUALITY NOISE LINEARITY CROSS-FIELD UNIFORMITY IMAGE ARTIFACTS.
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods
A silicon microstrip sensor for use in dental digital radiography P.F. van der Stelt Academic Centre for Dentistry Amsterdam, Amsterdam, the Netherlands.
Estimation of the effects of a lead vest on dose reduction for NPP workers using Monte Carlo calculations KIM JEONG-IN.
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods X-ray Imaging Part 3.
Reduced Dose of Proton CT Compared to X-Ray CT in Tissue-Density Variation Sensitivity T. Satogata, T. Bacarian, S. Peggs, A.G. Ruggiero, and F.A. Dilmanian.
Special Imaging Techniques Chapter 6 Bushong. Dynamic Computed Tomography (DCT) Dynamic scanning implies 15 or more scans in rapid sequence within one.
tomos = slice, graphein = to write
PHYSICS IN NUCLEAR MEDICINE: QUANTITAITVE SPECT AND CLINICAL APPLICATIONS Kathy Willowson Department of Nuclear Medicine, Royal North Shore Hospital University.
Introduction Modern radiation therapies such as intensity-modulated radiation therapy (IMRT) and volume modulated arc therapy (VMAT) demand from dose calculation.
8.1 PRODUCTION AND CHARACTERISTICS OF X-RAYS
Md.Kausher ahmed Electrical department. Biomedical engineering Code:6875.
LEC ( 2 ) RAD 323. Reconstruction techniques dates back to (1917), when scientist (Radon) developed mathematical solutions to the problem of reconstructing.
 An individual who performs radiography, radiation therapy, or nuclear medicine technology.
DIGITAL HIGH-RESOLUTION HEART PHANTOMS Abstract Background:X-ray based imaging modalities employ ionizing radiation with the potential for causing harmful.
Computed Tomography Physics, Instrumentation, and Imaging
Radiographic Dosimetry
Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.
Moscow-Bavarian Joint Advanced Student School March 2006, Moscow, Russia Correction and Preprocessing Methods Veselin Dikov Moscow-Bavarian Joint.
CT physics and instrumentation
Medical Imaging X-rays CT scans MRIs Ultrasounds PET scans.
Computed Tomography Q & A
JUSTIFICATION OF COMPUTERIZED TOMOGRAPHY EXAMINATIONS AND RADIATION RISKS IN EVERYDAY RADIOLOGICAL PRACTICE Darka R. Hadnađev, Olivera Nikolić, Sanja Stojanović.
Summer Practice in JINR Mathematical modeling of high-energy particle beams in accelerators.
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
Preparing Variable kVp Technique Charts By Prof. Stelmark.
QIBA CT Volumetrics - Cross-Platform Study (Group 1C) March 18, 2009 Interclinic Comparison of CT Volumetry Quantitative Imaging Biomarker Alliance.
Historical Review and Modalities in Diagnostics
Radiation Sources in medicine diagnostic Radiology
Radiographic Equipment
Image Quality The capacity to define, measure, and assess image quality is a primarily responsibility of a CT Technologist.
MEASUREMENTS OF RADIATION DOSES IN MULTISLICES COMPUTED TOMOGRAPHY EXAMINATIONS A. ELMAHDI*, A. SULIEMAN *Presenting author 1 Sudan Atomic Energy Commission,
Image Display. But first a review Remember the 3 main steps 1. Data Acquisition 2. Image Reconstruction 3. Image Display.
Part No...., Module No....Lesson No
Part No...., Module No....Lesson No
Radiation Sources in medicine diagnostic Radiology
What are the dose quantities in CT ? IAEA/RCA Kampala Kampala.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
MAGNETIC RESONANCE IMAGING by PRADEEP V.EPAKAYAL. Mem.no L.
BY: Avantika tiwari B-tech (ece) B-1 Batch. X-ray computed tomography, also computed tomography (CT scan) or computed axial tomography (CAT scan), is.
Background Computed tomography coronary angiography is an accurate method for the non-invasive diagnosis of coronary artery disease Eur Heart J 2005;26:1482–1487.
6:th IWORID, Glasgow, Scotland, July 2004 Energy Dependence in Dental Imaging with Medipix 2 Börje Norlin & Christer Fröjdh Mid Sweden University.
CT Multi-Slice CT.
Computed Tomography Basics
Evaluation of mA Switching Method with Penalized Weighted Least-Square Noise Reduction for Low-dose CT Yunjeong Lee, Hyekyun Chung, and Seungryong Cho.
Optimisation of Patient Protection for Radiography
CNRS applications in medical imaging
A Brachytherapy Treatment Planning Software Based on Monte Carlo Simulations and Artificial Neural Network Algorithm Amir Moghadam.
David J. Brenner, Maria A. Georgsson  Gastroenterology 
Geant4 at IST Applications in Brachytherapy
Estimation of the effects of a lead vest on dose reduction for NPP workers using Monte Carlo calculations KIM JEONG-IN.
Computed Tomography (C.T)
Presentation transcript:

1 Simulations and experimental verification of medical X-ray sources: CT case R. A. Miller C. Department of Biophysics, Medical Biophysics Centre University of Orient. Santiago of Cuba. BIOFISICA MEDICA Workshop on Instruments and Sensors on the GRID

2

3 Background X-ray devices are important tools in various medical applications. However, the x-rays produced by such devices can pose a hazard to human health depending on radiation absorbed dose in tissue (ADT). For this reason, ADT estimation constitutes a key aspect in the use of medical x-ray sources.

4 Optimisation Principle (ALARA) Doses involved in medical XR applications must be As Low As Reasonably As possible with the best image quality achievable.

5 Instruments and Sensors used in X-ray dosimetry

6

7 Instruments and Sensors used in X-ray (XR) dosimetry

8

9 Due to impossibility of detectors positioning in most internal anatomical structures where doses need to be known, absorbed radiation doses are estimated by several Simulation Approaches.

10 Existing XR Simulation Approaches Monte Carlo Technique [1], [2], (following the path of each photon).[1][2] Deterministic, based on the integral photon transport equation.[3][3] Computer Aided Drawing -CAD- models.[4], [5][4][5] Segmentation Method (a pencil beam is segmented both in energy and solid angle).[6][6] [1][1] Lazos, D., Bliznakova, K., Kolitsi, Z. And Pallikarakis, N. An integrated research tool for X-ray imaging simulation. Comp. Meth. Prog. Biomed. 70, 241–251 (2003). [2][2] Winslow, M., Xu, X. G., Huda, W., Ogden, K. M. And Scalzetti, E. M. Monte Carlo simulations of patient X-ray images. Am. Nucl. Soc. Trans. 90, 459–460 (2004). [3][3] Inanc, F. ACT image based deterministic approach to dosimetry and radiography simulations. Phys. Med. Biol. 47, 3351–3368 (2002). [4][4] Duvauchelle, P., Freud, N., Kaftandjian, V. And Babot, D. A computer code to simulate X-ray imaging techniques. Nucl. Instrum. Methods Phys. Res. B 170, 245–258 (2000). [5][5] Ahn, S. K., Cho, G., Chi, Y. K., Kim, H. K. And Jae, M. A computer code for the simulation of X-ray imaging systems. In: Proceedings of the IEEE Nuclear Science Symposium. Conference Record, Oregon, USA, 19–25 October 2003 (Piscataway, NJ: IEEE) pp. 838–842 (2004). [6][6] Fanti V., Marzeddu R., Massazza G., Randaccio P., Brunetti A. and Golosio B. A SIMULATOR FOR X-RAY IMAGES. Radiation Protection Dosimetry (2005), Vol. 114, Nos 1-3, pp. 350–354.

11 Phantoms for Dosimetry

12 Monte Carlo Simulation Systems

13 Simulation & Validation

Why CT? Percentage CT examinations vs. total X rays imaging CT contribution to Effective Dose with respect to every XR imaging USA WORLD SCENARIO Percentage CT examinations vs. total Radiological examinations CT contribution to World’s Collective Effective Dose

15 CT & World Population X 10 USA : 3.6x10 6 CT examinations in x10 6 CT examinations in x10 6 CT examinations in x10 6 examinations in children younger than 15 years in 2000

16 But… Whereas CT contributes to higher values of Effective Dose, they are under the threshold for deterministic or stochastic effects, in which genetic effects depends on absorbed dose. Cancer risk by abdominal CT scannings: 12,5/

17 An Optimization Approach in CT (AMAR) Attributes of patient, Modulation of scanning factors, Advances in Technology, Required diagnostic image quality.

18 Attributes of Patient Axial single 360  scanning

19 Modulation of Scanning Factors Patient Dose Noise Spatial Resolution Detail kV mAs Slice Thickness Matrix Size Kernel Algorithms Field of View Focus Size Tube heating Contrast Windowing Rotation Time Geometry Scanning Mode Scanning Long. Table Speed Pitch Shielding Prescription AMTC*

20 Advances in Technology CARE Dose 4D – SIEMENS (AMTC ,z )  - User selects an Eff. mAs

21 Advances in Technology Dose Right (DOM) – PHILIPS (MACT ,z )  - Based on the squared root of  obtained in previous anterior angular projection

22 Advances in Technology FlexmA – SHIMADZU (MACT z )

23 Advances in Technology 3D Auto mA – General Electric MS (MACT ,z ) Z- Modulates mA to keep a user specified quantum noise. A pitch correction factor is used in helical mode. Uses the standard kernel as a reference.

24 Advances in Technology Real E.C. – TOSHIBA (MACT ,z ) The user selects a mA and quantum noise reference levels

25 Required diagnostic image quality High Signal to Noise Ratio: –Solid Lung Tumours (except ground glass tumours). –Calcifications in Coronary Arteries. –Lung emphysema. Low Signal to Noise Ratio: –Abdominal scannings (liver or kidney). –Diffuse Lung Illness. Medium Signal to Noise Ratio: –Brain. –Abdominal / Thoracic (except for bleeding). Lung illness.

26 CT low dose protocols

Challenges for XR sources Simulations and Validation Personalized organ dose estimation and protocol optimization. Acceptable clinical image quality threshold identification to optimize dose. Initial mA user selection in some AMTC  introduces subjective restrictions La (e.g. high mAs for big patients). Simultaneous Modulation of kV and mAs.