Occupancy Classification Under NFPA 13 Examine the proposed facility and make recommendation on the Occupancy Classification Used to classify fuel loads.

Slides:



Advertisements
Similar presentations
Building Construction. Purpose Why should we, as firefighters, be concerned with building construction? Why should we, as firefighters, be concerned with.
Advertisements

Classification of Building Construction Types
BUILDING CONSTRUCTION
Determining the Occupant Load
Basics of Fire Sprinkler Design
Fire-Resistive Construction (2nd part)
Summary of NFPA 101 Interior Finish Requirements
Innovative New Technologies in Building & Construction.
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
Building Construction A fire resistive rating (FRR) is given in minutes or hours and relates to how long it takes to burn through a given material. Expressions.
N.F.P.A. 13R Justin Bohlmann FIR-204.
Definitions. 7 Class A –Wood, plastic and rubber Class B –Flammable liquids and gas Class C –Energized electrical Class D –Flammable metals Per NFPA statistics,
Type III Construction Jeff Prokop Ordinary Construction 200.
Site Planning and Layout  In the design phase of a facility, fire protection requirements are considered in the site layout  Water supply, traffic and.
IBC 2006 Chapter 5 Building Height and Areas After determining occupancies, the code analysis determines what height and areas are allowable for the occupancy.
NFPA Chapter 6 Chapter 6 is used to classify the occupancy and the hazard contents Proper classification is used to guide the implementation of.
STANDARD ON WATER SUPPLIES FOR SUBURBAN AND RURAL FIRE FIGHTING
Interior construction Harvard Graduate School of Design.
University of Sydney – DESA 1102 Structures LOADS & SUPPORTS Peter Smith & Mike Rosenman General Structural Concerns Functionality / Stiffness deformations.
Fire.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Portable Fire Extinguishers Selection and Placement University Safety Council April 19, 2006 Steven G. Triebold Fire Prevention and Protection Program.
Updates to NFPA 13 What’s New in the 2013 Edition Kenneth E. Isman, P.E., F.S.F.P.E. For the European Fire Sprinkler Network’s Fire Sprinkler International.
NFPA 13: Installation of Sprinkler Systems
FALAR Part 3 – Post Construction  Compilation of  Maintenance records of fire protection/life safety equipment  Test records of fire protection/life.
FPF190: Fire Protection Fundamentals FPF190 Fire Protection Fundamentals 1 Code Consultant.
6 Building Construction. 2 Objectives (1 of 3) Describe the characteristics of the following building materials: masonry, concrete, steel, glass, gypsum.
BUILDING CONSTRUCTION IFSTA : Chapter 3
Research Affecting the Design and Use of Water-Based Fire Suppression Systems Russell P. Fleming, P.E. IFSA Technical Director.
Architectural Design Construction of a Wall Section Upon completion of this assignment, you will be able to accurately and neatly draw, to scale and limits,
Fire and Emergency Services Company Officer — Lesson 17 Fire and Emergency Services Company Officer, 4 th Edition Chapter 17 — Preincident Planning.
Land Use and Development Regulations © 2010 Project Lead The Way, Inc.Civil Engineering and Architecture Our object in the construction of the state is.
Building Construction
© 2010 Delmar, Cengage Learning Instructor Resources for Lesson B Building Basics.
Unit 2 – Concepts of Construction FS102: Unit 2 - Concepts of Construction.
Building Codes. Codes  Building Code –Regional  BOCA, SBCCI, CABO, UBC, CITY OF DALLAS, –National  IBC  Fire Code –NFC, UFC, NFPA, Life Safety 101.
Fire-Related Properties of Materials Chapter 7. Mehta, Scarborough, and Armpriest : Building Construction: Principles, Materials, and Systems © 2008 Pearson.
Maximum Allowable Quantities and the Fire Hazard Analysis
6 Building Construction. 6 Objectives (1 of 3) Describe the characteristics of the following building materials: masonry, concrete, steel, glass, gypsum.
Code Analysis. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the NFPA)  Mechanical, electrical.
Fire Inspection and Code Enforcement, 7 th Edition Chapter 4 — Construction Types and Occupancy Classifications Inspector I.
Building Classifications: Construction Types.  Based on how the building is constructed.  Relates to:  Materials used  Combustibility  Fire-resistance.
FS102 – Building Construction for fire protection
Code Analysis: Don’t try this at home. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the.
Construction Type of Buildings
Design Development Code analysis Partition types.
Construction Types Chapter 3.
Sprinkler Loads on Trusses
ME444 ENGINEERING PIPING SYSTEM DESIGN
Sprinkler Loads on Trusses Educational Presentation.
The Shepherd Chemical Company Lisa Thamann 11/12/2013 AMMONIUM NITRATE A New Understanding.
Fundamental Concepts for Design of Special Hazard and Fire Alarm Systems Chapter 1.
Building Construction
Land Use and Development Regulations © 2010 Project Lead The Way, Inc.Civil Engineering and Architecture Our object in the construction of the state is.
Sprinkler Design FSE 221 – Fire Protection Systems
Designing Building Fire Safety EKU. What is Building Fire Safety Limiting Damage to the Building Preventing Damage to Occupants Reducing Fire Spread within.
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
FRT Lumber Use in Type III-A Buildings
Bottom Chord Live Load Concurrency and Truss Design
Why Know Building Construction
NFPA 5000 Occupancy Classifications
NFPA 600, INDUSTRIAL FIRE BRIGADE Module : 11 BUILDING CONSTRUCTION.
RULES OF ENGAGEMENT.
Land Use and Regulations
Building Construction
Building Construction
NFPA 101 Occupancy Specific Requirements
Land Use and Development Regulations
Types of Load Name____________________________ Tutor Group _____
Building Descriptions
Presentation transcript:

Occupancy Classification Under NFPA 13 Examine the proposed facility and make recommendation on the Occupancy Classification Used to classify fuel loads and fire severity associated with building operations Light Hazard Ordinary Hazards Group 1 and Group 2 Extra Hazard Group 1 and Group 2

Commodity Classifications Under NFPA 13 The commodity classification is important in sprinkler system design. Adjustments are made to sprinkler system water demands to ensure it can put out a fire involving the stored commodities. Examine the proposed facility and make recommendation on the Commodity Classification Defines potential fire severity based upon the type, amount, and arrangement of commodities

Commodity Classifications Under NFPA 13 Class I: noncombustibles packaged directly on wooden pallets, single layer cartons, or shrink wrapped Class II: noncombustibles packaged in slatted wooden crates, corrugated cartons Class III: wood, paper, natural fiber products Class IV: Group A or Group B plastics See the Commodity Classification document for definitions

NFPA 5000 Occupancy Classifications To classify a building under NFPA 5000: Chapter 6 provides definitions of the different Occupancy Classifications Assembly, Educational, Industrial, etc. In addition to the occupancy classification, a facility can be further classified as: Multiple occupancy: a building in which 2 or more classes of occupancies exist Mixed occupancy: a multiple occupancy in which the occupancies are intermingled Separated occupancy: an occupancy in which the occupancies are separated by a fire rated barrier as required in NFPA 5000

Classifying Your Occupancy Under NFPA 5000 Under NFPA 5000, the definition of an Industrial Occupancy is an occupancy in which products are manufactured, or in which processing, mixing, … or repair operations are conducted. Industrial Occupancies must meet Chapter 29 of the NFPA 5000 standards

Classifying Your Contents Under NFPA 5000 Building contents can be classified as Low, Ordinary, and High High Hazards Contents can be classified as Level 1 through 5 All are defined in Chapter 6 of NFPA 5000 Your building will be using limited amounts of flammable liquids in closed containers in the finishing area.

NFPA 5000, Chapter 34: Protection Levels Protection Levels 1 thru 5 If the quantities of hazardous contents exceeds the maximum allowable quantities (MAQ’s) under the Code, then the building construction must meet additional construction/protection requirements For example, if a quantities of Level 1 High Hazardous Contents exceeds the maximum allowable quantity, then the facility must meet Protection Level 1 requirements Same for other Contents Classifications (Level 2 – 5) If you don’t exceed MAQ’s, then follow Ordinary Hazard requirements

Special Operations NFPA 5000 identifies 66 special operations which require additional building construction requirements from NFPA standards outside of NFPA For example, a special operation would be a spray booth which would fall under NFPA 33: Standard for Spray Application Using Flammable and Combustible Materials.

Using Chapter 29 of NFPA 5000 In addition to the requirements in Chapter 29, an industrial occupancy must also meet the requirements of: Chapter 7, 8, 13, 14, 31, 35, 36, 37, 38, 39, and 40 Portions of other Chapters may be required as cited in the Chapter 29

ConstructionType Classifications Examine the proposed facility and make a recommendation on the following: Construction Type Classification (NFPA 220 and NFPA 5000) Type I: (Formerly Fire Resistive) Type II: (Formerly Non-combustible) Type III: (Formerly Ordinary Construction) Type IV: (Formerly Heavy Timber) Type V: (Formerly Wood Frame) Mixed Construction

Dead Loads Material, equipment, or components that are relatively constant throughout the structure's life Walls, floors, roofs, ceilings, stairways, built-in partitions, finishes, cladding and other similarly incorporated architectural and structural items, and fixed services equipment

Live Loads All the forces that are variable within the building’s normal operation cycle Moveable loads Wind load Snow load Rain load Earthquake load Flood load

Case Study 2 Following NFPA 13, selection of the NFPA Building Type Classification (Provided in Module) Following NFPA 13, determination of Occupancy Classification and Commodity Classifications (Provided in Module) Following NFPA 5000, determination of Occupancy Classification and Contents Classifications (Include Construction Type, Fire Ratings, Maximum stories, maximum square footage) Your facility will not exceed the maximum allowable quantities In your case study, provide one example of each which could be expected for a building of the type in the case study: Live Loads, Dead Loads, Impact Loads, Static Loads, Axial Loads, Eccentric Loads Selection of building materials for exterior, including foundation, structural supports, exterior walls and roof Must be selected according to your building type classification