Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.

Slides:



Advertisements
Similar presentations
DAQMASTER Features and Benefits
Advertisements

Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
Supervisory Control & Data Acquisition DAQ Networking.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Multi Functional Digital Fault Recorder
Efficient Management for Building Automation. Market Trend.
Advantech PAC Introduction
2500 Series ® SLICE I/O Series ® Slice I/O Best solution for installing a few I/O points in a remote location Mixed I/O – 4DI / 4DO / 2UAI / 2AO.
IDEC AUSTRALIA PTY LTD, UNIT 17, 104 FERNTREE GULLY RD, OAKLEIGH, VIC 3166 High Performance, Compact and Economical.
A Next Generation OCS Welcome to Horner Operator Control Station Training.
EUT 1040 Lecture 10: Programmable Logic Controllers.
ADAM-4000 Modbus Solution Mark Lin eAutomation Div. PSM
ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway
Applying Wireless in Legacy Systems
Sensor/Actuator Manager Candidates CPAC/NeSSI Workshop May 5, 2005, Seattle,WA by Softing North America Ken Hoover.
1 Automatic Meter Reading in Electronic Power Measurement Proposal based on AMR 2000.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Temperature is more than just hot or cold - You are responsible for temperature - we give the tools.
8/8/2015 Page 1 Νίκος Λεοντάρης Μηχανικός Τηλεπικοινωνιών Ιούνιος 26/ ADAM-4000 Remote DA&C Modules Product Overview.
The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Data Logger for Environmental Monitoring Stations and Networks
New Generation Automation Controller (PAC) Overview and Trend eAutomation Group Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
LabView Users Group Meeting June 20 th, 2006 Process Control Using Compact Field Point/Labview Real-time Michael Tockstein Microelectronics Technology.
ADAM-5000/TCP- Distributed Ethernet I/O
eAutomation Enabler – Advantech Industrial NETworking
SG-VoIP Page 1 / 14 PLANET Pan / Tilt Internet Camera Internet Surveillance Solution.
Video Management Control-Bit Technologies video system manages various types of video inputs; analog or digital, originated in both analog & IP cameras,
G4 Control and Management Solution for Data- Centers and Computer Rooms.
K200S Introduction.
IRRInet & ICC System Concept
A BRIEF INTRODUCTION TO FIELDBUS 4 hf NETLOGIC PLC TRADITIONAL CABLING SYSTEM TERMINAL BOARD.
Operator Panel and Programmable Logic Controller.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
AKR Sales Training For KOMAF Exhibition Kunyu Lee Product Manager
Unitronics 2009.
Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview.
USB DAQ Product USB DAQ Product Κώστας Γρηγορίου Sales Engineer Ιούνιος 26, 2007.
ETHLON LonWorks Ethernet Adapter Conventional Approach SIPAI Solution ETHLON DIRECTLY REPLACES SLTA-10 OR SLTA CONNECTIONS.
A new class in PC Data Acquisition Delphin Technology AG Felix Ottofuelling V5.0.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Κώστας Γρηγορίου Sales Engineer Ιούνιος 26, 2007 Connect Your Serial Device to Ethernet ADAM – 4570 / 71 / 77 / 79.
Advancing eAutomation 2-port Ethernet to RS-232/422/485 Data Gateway ADAM-4570 Reported by Alex Hsueh IAG Web & Comm. PM
SoftPLC In TealwareTM SoftPLC ProcessorsTM Hardbook SoftPLC’s
L ON W ORKS ® & IP Connectivity Training Center Copyright © 2004 – 2005 Echelon Corporation. All rights reserved. January 2005.
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
CPAC May 2005 John Mosher – Honeywell Sensing & Control Sensor Actuator Manager (SAM) Controller Considerations And Specification Identification.
ADAM-4000 Modbus I/O Market Focus Mark Lin eAutomation Div. PSM Industrial Automation Group
ICPDAS EtherCAT Solution
Scott Muench - Technical Sales Manager
Application Story Of ISaGRAF Embedded Controller Battery DAS 480 batteries, some power & security equipment of a telecom company 40 Ch. (10 pcs. I-87013)
CIMON PLC KDT Systems Co., Ltd.. KDT SYSTEMS Why CIMON PLCs ? All CPU share the same programming environment (CICON) All CPU share the same programming.
New product introduction:
WEBs-AX™ Controller WEB-700
CEA DSM Irfu SIS LDISC 18/04/2012 Paul Lotrus 1 Control Command Overview GBAR Collaboration Meeting Paul Lotrus CEA/DSM/Irfu/SIS.
Digital-watchdog.com Complete Megapixel Surveillance Solution DW-VP9xT4P DW-VP12xT8P DW-VP16xT8P Rev : 04/15 Presenter’s Name Title |
PROGRAMMABLE LOGIC CONTROLLER. Control Systems Types  Programmable Logic Controllers  Distributed Control System  PC- Based Controls.
An Overview When Connecting to Yaskawa Drives Date: 8/14/06, Rev: PP.AFD.26.
1 Data Acquisition, Monitoring & Management Solutions Supplied by DCM Transcal Phone or
Page 1 NeSSI II - A Platform for Micro-Analytical Devices Sensor Actuator Manager (SAM) Controller Considerations And Specification Identification CPAC.
Serial / Ethernet Converter - IE-CS-2TX-XRS232/485
Modular C ontroller S eries Product Introduction.
USB DAQ Product Introduction
COSEC ARC IP based Access Control Panel.
2500 Series® Compact System Components
2500 Series® Slice I/O.
2500 Series® Compact System Components
2500 Series® Compact System Components
2500 Series® Slice I/O.
GasGard 100 Control System
Presentation transcript:

Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007

Page 2 Features & Benefits Combined I/O designation for various applications Event Trigger/Data Stream supporting for Critical Monitoring Application Monitor multi-devices in one working zone Easy to configure embedded web page Wireless LAN I/O module to solve wiring problem

Page 3 External Ethernet Interface V.S. Seamless Ethernet Ethernet 10/100 Mbps Seamless Interface Best Communication Performance... HoneywellTC-FCCN01... HoneywellTC-FCCN01... HoneywellTC-FCCN01... HoneywellTC-FCCN01 Serial Network (up to kbps) I/O (10/100 Mbps) Ethernet Data Gateway Communication Rate Up to kbps You do not speed up the Communication Rate actually! External Ethernet Interface Seamless Ethernet ADAM-6000 Bring You Ultimate Ethernet I/O Solution

Page 4 Local LAN Limitation V.S. Internet Available Internet ADAM-6000 in LAN General Ethernet Devices in LAN Distance is always a problem in remote system Now you can operate your system anywhere !

Page 5 Fixed V.S. Free Operating Location Fixed Operating location V.S. Free operating location 3) Install Driver or Monitor S/W 1) Serial I/O Configuration I have to stay in control room all the time Ethernet ADAM ) Connect to Ethernet Directly 2) Configure the IP & I/O Range Only 3 min. I can walk around anywhere!! 3) Open your Internet Explorer 2) Data Gateway Configuration RS-232/485

Page 6 Proprietary V.S. Open System Architectures Proprietary System Architecture V.S. Open System Architecture ADAM-6000 Specific HMI Server Specific network Specific I/O Devices “Specific” means, No expansion, No integration, and No choice! Ethernet ( Modbus/TCP ) Any User’s AP with Modbus/TCP Driver Any HMI Package with Modbus/TCP OPC Server Any field equipment follow Modbus/TCP protocol Modbus/TCP, the world-wide standard

Page 7 eAutomation System Solution Architecture UNO series ADAM-6500 Comm. Controller ADAM-6000 I/O HMI Station Internet TCP/IP& UDP Internet Network ADAM-6520 ADAM-6000W series ADAM-6000 I/O ADAM-6022 PID Controller

Page 8 ADAM-6000 Product Line Overview Analog Input Analog Output Network Digital I/O Platform ADAM Win CE.NET StrongARM LAN (10 Base-T) - RS-232 x 3 - RS-485 x 2 ADAM WinCE.NET XScale LAN (10/100Mbps) - 1 RS-232/1 RS External CF Slot ADAM RTD ADAM AI/ 2 DO ADAM AI/ 8 DO ADAM AI / 2 AO/ 2 DI / 4 DO ADAM PID Loop - 6 AI/ 2 AO/ 2 DI/ 4 DO ADAM port Hub ADAM port Switch ADAM port Switch (w/Fiber interface) Controller ADAM DI/ 6 DO ADAM DI/ 2 DO/ 2 Counter ADAM DI/ 8 DO ADAM DI/ 6 Relay Output ADAM DI/ 6 Power Relay Output

Page 9 ADAM-6015/6018 Temp. Input Module ADAM RTD - 16-bit, 16 samples/sec - Multi-channel / Multi-range - Pt-100, Pt-1000, Ni, Balco - Burn-out Detection Digital I/O Analog Input Analog Output Controller Platform ADAM Thermocouple/ 8 DO - 16-bit, 10 samples/sec - Multi-channel/ Multi-range - Thermocouple - Alarm trigger to DO - Burn-out Detection

Page 10 ADAM-6017/6024 Analog I/O Module ADAM AI/ 2 DO - 16-bit, 10 samples/sec - Multi-channel/ Multi- range - V, mV, mA - Alarm trigger to DO ADAM AI/2 AO/2 DI/2 DO - Multi-channel/ Multi- range - mA, V for Analog I/O - Alarm trigger to DO - DI for emergency latch output Digital I/O Analog Input Analog Output Controller Platform

Page 11 Remote I/O ADAM-6500 Ethernet Based Comm. Controller Hardware Spec. - CPU: StrongARM 206 CPU - RS-232*3 / RS-485* base-T * 1 - CF Slot inside enclosure (up to 256MB) - 16MB Flash / 64MB SDRAM - Isolation 1500 V RMS Software Spec. -O/S: Windows CE. NET 4.2, Win CE.NET inside Free download Embedded VC++ for programming Download Control Program ADAM-6500 Ethernet ADAM-6000 I/O Internet Digital I/O Analog Input Analog Output Controller Platform

Page 12 ADAM-6501 Web-enabled Universal Communication Controller Hardware Spec. - CPU: Xscale RS-232*1 / RS-485*1 - 10/100Mbps Ethernet * 1 - Open CF Slot (up to 512MB) - 32MB Flash / 64MB SDRAM - Battery Backup RAM : 2MB - Isolation 1000 V RMS Software Spec. -O/S: Windows CE. NET 4.2 Digital I/O Analog Input Analog Output Controller Platform

Page 13 ADAM-6500/6501 Differences ADAM-6500 ADAM-6500 – – StrongArm 206 – – Ethernet : 10 Base-T – – Flash Memory : 16MB – – CF Slot inside enclosure --- (up to 256MB) – – No Backup RAM – – 3xRS xRS-485 ADAM-6501 ADAM-6501 – Xscale 400 – Ethernet : 10/100Mbps – Flash Memory : 32MB – Open CF Slot --- (up to 512MB) – Backup RAM : 2 MB – 1xRS xRS-485

Page 14 ADAM-6022 Dual Loop PID Control Module ADAM AO/ 6 AI/ 2DI/ 4DO - AO: mA, Voltage output, Output Read-back - AI: V, mV, mA, T/C - DI: TTL input - DO: Open collector to 30 V DC V DC Isolation - Built-in PID Digital I/O Analog Input Analog Output Controller Platform

Page 15 Remote Management Solution Service Scope Data Center Equipment Diagnostic System History Record Service … Mobile Network Wireless LAN Wireless Device Wireless Ethernet I/O Wireless Ethernet Data Gateway … Vending Machine Traffic Service Environment Automatic Metering Building Facility Internet Ethernet I/O Ethernet Data Gateway Serial Devices

Page 16 ADAM-6000 Wireless I/O Modules ADAM-6050W 18-ch iso. DI/O Module I/O Type: 12 DI & 6 DO Digital Input: Dry Contact/Wet Contact/Counter Digital Output: Open Collector to 30 V 200 mA Pulse Output ADAM-6051W 16-ch iso. DI/O Module I/O Type: 12 DI / 2 DO / 2 Counter Digital Input: Dry Contact/Wet Contact/ Counter/Freq. Digital Output: Open Collector to 30 V200 mA Counter Channel: Counter Mode : Max. 4,294,967,285 Frequency Mode: 0.3 ~ 1000 Hz max. ADAM-6060W 6 DI / 6 Relay Module I/O Type: 6 Relay & 6 DI Relay Output (Form A): Contact rating: 0.5A, 1A Digital Input: Dry Contact The Seamless Mobile Monitoring Solution

Page 17 Modbus Integrated Architecture Industrial PC & Human Machine Interface Software Ethernet Modbus/TCP IEEE802.11b Modbus/TCP ADAM-6000 Wireless LAN I/O Modules Ethernet-based Operator Panel Ethernet Modbus/TCP IEEE802.11b Modbus/TCP ADAM-6000 Wireless LAN I/O Modules Ethernet-based Modbus Controller Ethernet Modbus/TCP IEEE802.11b Modbus/TCP ADAM-6000 Wireless LAN I/O Modules

Page 18 Quick Customized Web Page Set your customized web page in a few seconds!!! Download into ADAM-6000 Web page customization Utility -Customized Tag Name -Customized Tag Description -Customized Status Description -Customized Page Description

Page 19 Applications of ADAM-6000W Wireless LAN IO in Building Automation Wireless LAN IO in Facility Management

Page 20 Thank You