Health, Medicine and Biotechnology Opportunity Accurate Measurement of OPA Concentration for Disinfection Applications Benefits: An analytical process.

Slides:



Advertisements
Similar presentations
Generic Pressurized Water Reactor (PWR): Safety Systems Overview
Advertisements

Let’s watch a DVD… DVD Instructor Notes
Dr. Thaweesak Tirawatnapong Chula Medical Research Center (Chula MRC)
ENGINES, TRANSMISSIONS, FINAL DRIVES, TRAVEL/SWING MOTORS & HYDRAULICS: IMPROVE LIFE BY 2X TO 3X STRATEGIES TO INCREASE LIFE OF COMPONENTS AND EQUIPMENT.
QUALITY CONTROL IN HEMATOLOGY
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
Inert Gas Purification Systems Why do we need them??? Many of the materials used in research and development today are extremely air sensitive, and can.
Lessons Learned from Sarnia Area Monitoring Presented by: Ed Kuley ORTECH Environmental November 6, 2014.
SANITARY DESIGN PRINCIPLES FOR FACILITIES. ZONES OF CONTROL.
Using Disinfectants and practicing Sterilization in the Veterinary Clinic.
Supercritical Fluid Chromatography and Extraction
GENERAL IDEAS IN AIR POLLUTION CONTROL
Organization of an Organic Chemistry Laboratory. Organic chemistry laboratories are mainly specified to conduct organic chemistry research studies, in.
ACADs (08-006) Covered Keywords Lab ware, glassware, balances, heating apparatus, separation apparatus, hydrometers, viscometers, pipettes, titrators,
MERCURY CONTROL DURING NATURAL GAS PROCESSING SHEQ problems and solutions Zdravko Špirić INA-Naftaplin, Zagreb, Croatia
Manure Processing With Microwave Treatment Midas Green Technologies.
The I 2 Air Fluid Protocol; The Eco-friendly method for the elimination of bio-fouling in heat exchangers.
Dr Samah Kotb Lecturer of Biochemistry 1 CLS 432 Dr. Samah Kotb Nasr El-deen Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Nasr.
Sterilizing Techniques 4-H Veterinary Science Extension Veterinary Medicine Texas AgriLife Extension Service College of Veterinary Medicine and Biomedical.
Sanitation and HACCP Monitoring with the LIGHTNING MVP BioControl Systems, Inc.
Supplementary Training Modules on Good Manufacturing Practice
Antoinette Barton-Gooden Patient and Health Care worker Safety.
ACADs (08-006) Covered Keywords Demineralization, reverse osmosis, evaporation, distillation, oil separation, condensate polishing, boiler protection.
POWER PLANT.
SENSOR TECHNOLOGY Opportunity Field Deployable PiezoElectric Gravimeter (PEG): A Light Weight Cost-Effective Solution for Structural Measurements Benefits:
Standard Operating Procedures.  To understand: › The purpose of having SOP’s and how they affect the daily workings of laboratories.  To discuss: ›
Pharmaceutical Water Systems Alain Kupferman Manufacture of sterile medicines – Advanced workshop for SFDA GMP inspectors, Nanjing, November 2009.
U NIVERSITY OF M INNESOTA Dept. of Environmental Health and Safety Hazard Analysis Process for Adding Amines to Steam System C. Moody,
Perchlorate Analysis by Ion Chromatography The CA DHS Protocol H.S. Okamoto, D.K. Rishi and S.K. Perera.
Automotive Algebra Maintaining the cooling system Using Algebra for a simple solution Joe Agruso,Xochitl Molina.
NANS I 3 Steve Adler December 6, Indications for Use U.S. –Infumorph Europe –Morphine and Baclofen.
Decontamination of filed equipment used in environmental site characterization and ground-water monitoring projects University of Arkansas 11/13/2006 By.
Introduction To the pr EN ISO Project norm
WATER’S LIFE-SUPPORTING PROPERTIES. Water’s polarity leads to hydrogen bonding and other unusual properties The charged regions on water molecules are.
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 J. Green Why do we need Good results? 1 Chemical.
CONSULTORA EN RIESGO QUÍMICO INDUSTRIAL LTDA. Innovation industrial safety as well as on labor health - DELIVERY OF TECHNOLOGICAL PRODUCTS - ASSISTANCE.
Advanced Aeration, Inc. Presentation of Vacuum Bubble ® Technology.
This class cannot be shared or copied without the written permission of PracticeWorks Systems, LLC.
Effective Sanitation 1. GMPs SANITARY EQUIPMENT DESIGN SANITARY FACILITY DESIGN HACCP TRAINED EMPLOYEES VALIDATED & VERIFIED PROCESSES REPEATABLE FOOD.
Safety-Critical Systems 7 Summary T V - Lifecycle model System Acceptance System Integration & Test Module Integration & Test Requirements Analysis.
Idaho RISE System Reliability and Designing to Reduce Failure ENGR Sept 2005.
Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015 Introduction to Quality Control.
The I 2 Air Fluid Protocol; The Eco-friendly method for the elimination of bio-fouling in heat exchangers utilizing I 2 infused mixed media.
Chapter 29 Supercritical Fluid Chromatography and Extraction.
Seminar on, “ CALIBRATION TECHNIQUES FOR MAGMETERS” Presented By, Bhushan Patil Guided By, Prof. A.S. Kulkarni.
Produced Water Treatment For Recycle 22 nd IPEC – Denver, CO Dan Mueller, P.E.
CHAD FISHER HAZARDOUS WASTE COMPLIANCE INSPECTOR WA STATE DEPARTMENT OF ECOLOGY JANUARY 29, 2016 Safety, Storage and Treatment of High Level Disinfection.
Prof. Moustafa M. Mohamed
1 1. What is Sterilization? 2. Type of Sterilization Methods. 3. What is ETO Sterilization? 4. Why & where ETO Sterilization used? 5. Fact about ETO.
If you have a transaction processing system, John Meisenbacher
Floors, walls, and ceilings: Materials must be smooth and durable for easier cleaning Must be regularly maintained 9-3 Interior Requirements for a Safe.
Chapter 1: The Nature of Analytical Chemistry
Phil Dempsey ISS Vehicle Office July 15, 2014 Inspection Considerations from the ISS Program NASA In-Space Inspection Workshop 2014.
Working safely with Biological materials Aseptic technique, sterilization and tissue culture techniques.
Laboratory Decommissioning : Essential Tools and Lessons Learned Jim Carscadden Division of Environmental Protection Office of Research Facilities.
Failure Modes, Effects and Criticality Analysis
ANLEC R&D COMMUNICATION PACK ( ). While mercury can be removed from Oxy-Fuel flue gas, further work is required to understand its form and removal.
Flow chemistry. Flow chemistry is also known as continuous flow or plug flow chemistry. It involves a chemical reaction run in a continuous flow stream.
Fundamentals of Analytical Chemistry Eighth Edition.
Quality Assurance.
Unit 11: Calibrating Instruments
Critical Environment Control Solutions
PH meter.
Control of Microorganisms by Physical and Chemical Agents
Supercritical Fluid Chromatography and Extraction
Nuclear Hydrogen Production Program in the U.S.
Crude oil Treatment process
Corrosives.
Risk informed separation distances for hydrogen refuelling stations
 Define: The stirring heating plate or heated stirring heating plate has been developed to heat and mix fluids contained in laboratory receptacles such.
Presentation transcript:

Health, Medicine and Biotechnology Opportunity Accurate Measurement of OPA Concentration for Disinfection Applications Benefits: An analytical process was developed which could verify a known concentration of the disinfectant, O- phthaladehyde (OPA). OPA is a disinfectant that effectively inhibits the growth and recovery of viable microorganism. The Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) is primarily responsible for the removal of heat loads from payload and system racks. This also includes, heat loads from crew members, experiments, electrical equipment and other systems generate heat inside the modules of ISS that also has to be rejected. To accomplish this, the IATCS consists of loops that circulate water through the interior to collect the excess heat. OPA is included in water coolant to prevent microbial impacts to coolant flow, heat transfer, and inhibit corrosion all of which could result in damage to the IATCS and subsequently affect crew health and safety. The concentration of the OPA in the coolant fluid is critical to the process and previously used methods for developing, analyzing and validating the OPA concentration had been proprietary and no longer available to NASA. To address this critical need for ISS, a simple inexpensive, National Institute of Standards and Technology (NIST) traceable process to analyze OPA that neither required highly hazardous chemicals nor involved a hazardous waste stream, was developed. Cost-Efficient Design: easy, inexpensive process; analytical service for previously used process was proprietary and costly. Innovative Utility: reversed a NIST traceable EPA method for quantitation to develop method Data Sensitivity: NIST traceable process can verify with precision and accuracy Novel approach: previous techniques were labor intensive and hazardous Safe: does not produce a hazardous waste stream National Aeronautics and Space Administration NASA astronaut Mike Hopkins, Expedition 38 flight engineer, uses the Fluid Servicing System (FSS) to refill Internal Thermal Control System (ITCS) loops with fresh coolant in the Destiny laboratory of the International Space Station.

O-phthaldehyde (OPA) is commonly used as a high-level disinfectant (for example, for sterilization of heat sensitive medical instruments) that demonstrates effective microbicidal activity against a range of microorganisms including mycobacteria, gram-negative bacteria and spores. On the International Space Station (ISS), systems produce waste heat which needs to be transferred from the ISS to space to achieve thermal control and maintain components at acceptable temperatures. The Internal Active Thermal Control System (IATCS) is a water based system which works in conjunction with the EATCS (External ATCS), an ammonia based system, to facilitate heat transfer aboard ISS. The purpose of the Thermal Control System of ISS is to keep all internal and external equipment and payloads at temperatures within their specific thermal requirements. The IATCS circulates water through two independent loops inside the modules, a Low Temperature Loop and a Moderate Temperature Loop in order to segregate the heat loads, to simplify heat load management and to add redundancy in case of equipment failures. Water is used because it is an efficient heat transfer fluid and presents no danger to crew members in the event of an internal leak. An OPA water solution is required and used as a high level disinfectant to effectively inhibit the growth and recovery of viable microorganisms in the IATCS coolant to prevent microbial negative impacts to coolant flow, heat transfer, corrosion. Accumulation of microorganisms on surfaces could result in material degradation. Should the IATCs become damaged, crew health and safety are at risk. Therefore, the concentration of the OPA in the coolant fluid is critical to maintaining proper functionality of IATCS. The previously used method for developing, analyzing and validating the OPA concentration had been proprietary process which no longer was available to NASA. A subsequent literature search could only provide a technical method that was both labor intensive and involved using hazardous materials (hydrazine dissolved in concentrated sulfuric acid). To address this critical need for ISS, a simple inexpensive, National Institute of Standards and Technology (NIST) traceable process to analyze OPA (that did not used hazardous chemicals and did not result in a hazardous waste stream that is costly to discard) was developed. A process by which OPA was quantitated in water-based liquids using a high pressure liquid chromatography (HPLC) method combined with post-column derivatization was developed. To do this, NIST traceable EPA method 547 for quantitating glyphosate concentration in water, which uses HPLC method that uses OPA to convert glycine (not glyphosate) in a post-column reactor into a compound that can be more readily detected, was reversed engineered. By reversing the premise of this process, glycine is reacted in excess with the OPA solution along with 2-mercapto-ethanol. The resultant reaction complex is used to determine the OPA concentration with accuracy and precision. Calibrations were established, initial demonstration of proficiency studies (IDOPs) and a method detection limit (MDL) studies were performed to demonstrate precision and accuracy of the process. This developed and validated method to analyze OPA offers a new effective, low cost HPLC method that substantially reduces the future process waste stream and avoids potential health hazard effects associated with previously identified processes.. The Technology Applications: Ortho-phthalaldehyde is a high-level disinfectant that received FDA clearance in October It contains 0.55% 1,2-benzenedicarboxaldehyde (OPA). Studies have demonstrated excellent microbicidal activity in vitro. OPA is used at various concentrations in the medical industry for urological instrumentation, endoscopes and other heat-sensitive, semi-critical medical devices, as well as for cleaning and disinfection and storage of patient care devices. Applications Publications Provisional patent for OPA by Reverse Derivatization was filed on November 21, 2014, and has App Serial No. 62/082,873. SSC Case number: SSC