Www.hvac.vn Electromagnetic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.

Slides:



Advertisements
Similar presentations
MAO Flow Meters Sales Deck | Presentation Title What is the MAO Flow Meter? The MAO flow meter is an instrument used for monitoring or measuring.
Advertisements

ULTRASONIC WATER AND FLOW METERS
Unit Operation Lab K S Chou Ch E, N T H U 1. A: Fluid Flow Experiments A1 - Friction Coefficient in Tubes A2 - Flowmeters  Types of flowing fluid: gas.
Copyright 2011 McCrometer, Inc. 09/11 Ultra Mag ® Advanced Electromagnetic Flowmeter.
Thermostats The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Welcome Bienvenue Willkommen Bienvenido Добро пожаловать ようこそ 歡迎.
HVAC Air Flow Measurement The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Water and Wastewater Focus Wireless Sales Push 2009.
Open Channel Flow Panel Meters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Variable Frequency Drives VFD Basics
Training Course Industrial Solutions. You Can Measure the Benefits… 2 Industrial Solutions  Water and waste  Food and beverage  Chemical  Fuel and.
The Future of Irrigation Metering. SEAMETRICS ™ FLOW METERS -PRODUCT OVERVIEW-
Paddlewheel Flow Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Presented by Brent Baird Energy Monitoring with Ultrasonic Flow Meters Ultrasonic Flow Meters.
Electromagnetic Flowmeter Why use flow meters What is a magnetic flow meter – How do they work – How are the different from other meters Items that will.
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
Process Variables and Sensors. Parts and materials needed for today (instructor will provide): DP transmitters Thermocouples Filled-bulb temperature sensor.
1 Syafruddin Hasan. 2 Systems Concepts Automated systems that control flow rates or volume employ the following components: Automated systems that control.
Flow Sensors.
Insertion Paddle Wheel
Chemical Engineering 3P04 Process Control Tutorial # 2 Learning goals 1.The feedback cause-effect principle 2. Key element in the loop: The control valve.
Week 1 Unit Conversions Mass and Volume Flow Ideal Gas Newtonian Fluids, Reynolds No. Week 2 Pressure Loss in Pipe Flow Pressure Loss Examples Flow Measurement.
Water and Wastewater Focus Wireless Sales Push 2009.
Submersible Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
By Norman Bartlett Creative Sensor Technology 1. Irrigator’s View of Landscape Irrigation “ We are beautifying the world” Public’s View “You are wasting.
Wedge Flow Element 1.
Features: ERTL TESTED  Displays distance to leak location in meters.  Indicates Cable break condition.  Modbus Output for BMS Monitoring.  Operates.
Introducing SITEL Control srl. Established in 1988 Infrared Thermometers manufacturing Electronics Assembling.
March 2010 Hastings Product Training Flow Products Overview.
Chemical Engineering 3P04
RPM Series Rotary Meters Presented by Mike Javon Product Coordinator Industrial Products Business Unit.
Mazzei Injector Company, LLC
Flow measurement.
Ultrasonic Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Seminar on, “ CALIBRATION TECHNIQUES FOR MAGMETERS” Presented By, Bhushan Patil Guided By, Prof. A.S. Kulkarni.
Industrial Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Gas Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Handheld Digital Manometers The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Differential Pressure ATEX Enclosures The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
PF3W Series 3-Color Display Digital Flow Switch Planned release date: May 2012.
Miscellaneous Test Equipment Combustion, Tachometers, Hygrometers The materials included in this compilation are for the use of Dwyer Instruments,
Ultrasonic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Powder & Bulk Level Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Temperature Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Water Detectors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Gas Mass Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Pressure Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Our Controllers MegaTron MegaTron Multiple System Capability Multiple System Capability Internet Communication Internet Communication Conductivity.
Vibration Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
Pressure Transmitters and Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers.
Series RHP Temperature and Humidity Transmitter The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential.
Ionizer IZS31 Series. 1. Features (1) Following functions are added to the current IZS30 on sale. Detects the dirt on the electrode needle. Detects the.
Air Handler Demonstration The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Flow Technology Overview The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Electromagnetic Flow Meters Overview. Type M3000/M4000 / Type M1000 Type II / Type III Type ModMAG ® M2000 / Type B-MAG ™ I M5000 Type Food.
Signal Transmission and Conversion, Test Review - Agenda
Copyright SwissFlow B.V.
Creative solutions for water management for Irrigation Control Systems
Asahi/America Electric Actuators Series 94.
Creative solutions for water management with Irrigation Smart Control Systems
Forging new generations of engineers
Electromagnetic Flow Meter Phone: +(91)-(20) /
Phone: +(91)-(20) /
Forging new generations of engineers
Instant Electric Heating Tap - Wall Mount or Surface Mount
Customer Presentation
Customer Presentation
Asahi/America Electric Actuators Series 94.
Presentation transcript:

Electromagnetic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2014 Dwyer Instruments, Inc.

Overview Principles of Operation Types of Electromagnetic Flow Sensors Insertion In-line Installation Accessories Rate and Totalizers Analog Transmission Target Markets Application Photos and Uses

Overview Insertion Adjustable IEFS Fixed EFS2 In-line Small LOFM & MFS/MFS2 Large FLMG MFS FLMG MFS2 LOFM IEFS EFS2

Principle of Operation Faraday’s Law Conductive liquid moving through a magnetic field produces a current

Principle of Operation Current is proportional to velocity of the liquid

Principle of Operation A magnetic field is directed through the conductive liquid Voltage generated is proportional to the movement of the flowing liquid

IEFS - Introduction Adjustable, insertion electromagnetic flow meter Designed for pipe sizes from 3 to 48˝ ( 76 to 1219 mm) Comes in different materials Stainless steel and brass Purchase by size and material

IEFS - Specifications Service: Compatible clean or dirty non-coating, conductive liquids Range: 0.28 to 20 ft/s (0.08 to 6.09 m/s) Accuracy: ±1% FS Output: Current sinking, square wave pulse, opto-isolated, ft/s Enclosure Rating: NEMA 4X (IP66)

IEFS - Features Field adjustability allows for quick ship and installation time Brass and stainless steel materials of construction Versatility for higher temperature and pressures and varying fluids Reverse flow output option Allows meter to indicate flow in two directions, forward or reverse

IEFS - Features NPT or Hot-Tap process connection Hot-Tap option allows for service of system without draining process fluid

EFS2 - Introduction Electromagnetic flow meter Fixed insertion depth 1 to 12” (25 to 305 mm) PVC, Brass, and Stainless Steel

EFS2 - Specifications Service: Compatible clean or dirty non-coating, conductive liquids Range: 0.28 to 20 ft/s (0.08 to 6.09 m/s) Accuracy: ±1% FS Output: Current sinking, square wave pulse, opto-isolated, ft/s Enclosure Rating: NEMA 4X (IP66)

EFS2 - Features Fixed depth 3 models allow for range of pipe sizes 1 to 3” (25 to 76 mm) 4 to 10” (102 to 254 mm) 12” (305 mm) PVC, Brass, and Stainless Steel Materials of Construction Versatility for higher temperature and pressures Higher chemical compatibility for varying fluids Reverse flow output option Allows meter to indicate flow in two directions, forward or reverse

EFF Fittings Series EFF fittings and tees required for installation Stainless Steel, Bronze, and PVC fittings and tees allow for installation in virtually all applications

Advantages and Disadvantages IEFS2 – Adjustable NPT and Hot Tap Mount One model for pipes 3 to 24” (76 to 607 mm) Higher Cost EFS2 - Fixed Lower Cost Operational in pipes down to 1” (25 mm) Require additional mounting components

LOFM - Introduction In-line, small pipe diameter electromagnetic flow sensor PVDF wetted material 3/8” (9.5 mm) & ¾” (19 mm)

LOFM - Specifications Service: Compatible clean or dirty non-coating, conductive liquids Range: 0.03 to 20 GPM (0.01 to 1.3 LPS) Accuracy: +1% of reading Output: Current sinking, square wave pulse, opto-isolated, 30 5 mA max. and 4 to 20 mA Enclosure Rating: NEMA 4X (IP66)

LOFM - Features Corrosion resistant PVDF material No moving parts Non obstructive flow Can accurately measure flow rates as low as 0.03 GPM (.002 LPS)

MFS & MFS2 - Introduction In-line electromagnetic flowmeter For small pipe sizes MFS 316 SS body ½ to 1” (13 to 25 mm) MFS2 plastic body ½ to 1-1/4” (13 to 32 mm) MFS MFS2

MFS & MFS2 - Specifications Service: Water and other conductive liquids Accuracy: ±2% of reading Output: Frequency: Square-wave, NPN Analog: 4 to 20 mA Enclosure Rating: NEMA 4 (IP65) MFS MFS2

MFS & MFS2 – Features Compact design Low cost No moving parts Ideal for lower flows Lower pipe sizes MFS MFS2

FLMG - Introduction Inline electromagnetic flowmeter Transmits and displays flow rate and total 150 # ANSI flange 4, 6, 8, 10 in (102, 153,203, 254 mm)

FLMG - Specifications Service: Compatible non-coating conductive liquids Wetted Materials: Liner: Dual durometer rubber Accuracy: ±1% Output: Current sinking square wave pulse, opto- isolated Battery Life: 2 months with power failure; 10 years with power Enclosure Rating: NEMA 4X (IP66)

FLMG - Features No Moving Parts Unaffected by potential debris in flow such as sand Manufactured to customer specification Model designed to mount in 4 to 10” (102 to 254 mm) lines No adjusting sensor height to center of flow, bolt inline an go Larger magnetic field Requires fewer upstream and downstream pipe diameters

FLMG - Features NEMA 4X (IP66) rated housing Allows for use both indoor and outdoor Flow outputs Rate and flow totalizing standard Internal battery backup standard Allows unit to continue working if power failure/outage occurs

Advantages and Disadvantages In-line vs. Insertion Built to specific pipe size, one size does not fit all Flow-thru design allows for minimal/no pressure drop Can be used in applications with solids and debris in flow stream Higher cost than insertion flow sensors

Installation Accessories RTI Rate/Total Indicator BAT Blind Analog Transmitter

RTI - Features Indicator and transmitter accessory for IEFS, EFS2, and FLMG Takes pulse input from flow sensor and converts signal to display flow rate and total Displays flow rate and flow total on LCD display Provides linear 4 to 20mA output of flow NEMA 4X (IP 66) rating for indoor and outdoor use

RTI - Features Mounts to wall, flow sensor, or local panel

BAT - Features Transmitter accessory for IEFS, EFS2, and FLMG No Display, blind unit Takes pulse input from flow sensor and converts signal to flow rate signal Output signal linear 4 to 20mA output of flow NEMA 4X (IP 66) rating for indoor and outdoor use

BAT - Features Mounts to wall or Flow Sensor

When not to recommend electromagnetic flow sensors Applications with fluids with low conductivity De-ionized water or boiler feed water Low conductivity can cause the meter to turn off and indicate zero flow Hydrocarbon and gas applications Hydrocarbons and gases are non conductive and can not be measured

Applications Agriculture Irrigation Sprayers and Spreaders Fertigation Building Automation HVAC Systems Municipalities Water and Wastewater Industrial Process Chemical Metering Pumps

Agriculture Irrigation Used for measuring and monitoring water consumed during growing season on pivot systems Sprayers Used for monitoring chemical sprayed on crops during growing season Spreaders Used for monitoring flow of organic materials, including manure, used as fertilizer

Building Automation Water audits and consumption Used to verify water intake to building, verified against city municipality billing LEED Used to verify water consumption for LEED credits in buildings for water conservation

Municipalities Wastewater Facilities Used to measure treated and untreated sewage Used to measure process water Used to measure chemical flow for sewage treatment Water Facilities Used for measuring flow in water mains Used for early indication of water main break

Irrigation Magnetic Flowmeter used for flow measurement in Pivot Irrigation system

Spreader Magnetic Flowmeter used in manure spreading system

Fertigation Golf course groundwater monitoring and fertilizing

HVAC System Magnetic Flowmeter used for billing in a heating system

Water Magnetic Flowmeter used in pump house for groundwater monitoring

Wastewater Gravity-fed waste pumping facility

Industrial Magnetic Flowmeter used in water park pump and treat

The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2014 Dwyer Instruments, Inc.