Acknowledgments The authors would like to thank Dr Michael Norton for providing accessible and well equipped microscopy facilities, supported in part by.

Slides:



Advertisements
Similar presentations
An Introduction to Multivariate Analysis
Advertisements

Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
Collection of Physical Evidence at a Crime Scene Chapter 2/ O’Connor.
Electromagnetic Radiation
Introduction This project used cosmic rays to test a prototype Minimum Bias Trigger Scintillator (MBTS) that will be used in the ATLAS experiment at CERN.
Module 2: Analytical methods and separation techniques.
RHESSI/GOES Observations of the Non-flaring Sun from 2002 to J. McTiernan SSL/UCB.
Scanning Electron Microscope Jamie Goings. Theory Conventional microscopes use light and glass lenses SEM uses electrons and magnetic lenses to create.
Scanning Electron Microscopy
Forensic Chemistry/Trace Evidence
Honors Forensic Science.  Introduction  Organic substances constitute a substantial portion of physical evidence submitted to crime labs  Carbon does.
Classification of NYC Aerosols by X-Ray and Optical Methods By: John Sangobowale (Mount St. Michael Academy) and William Dennis ( John F. Kennedy H.S.)
Trace Evidence (Part I)
Forensic Instrumentation
SEM (SCANNING ELECTRON MICROSCOPE) Özgen Buğdaycı Elif Topçuoğlu Yavuz Duran Hacettepe University
Understanding mass spectroscopy. Mass spectroscopy is a very powerful analytical tool that can provide information on the molecular mass of a compound,
6- PRENTICE HALL ©2007 Pearson Education, Inc. Upper Saddle River, NJ CRIMINALISTICS An Introduction to Forensic Science, 9/E By Richard Saferstein.
Purpose A chemical bath deposition method was used to coat the frustules with CdS, taking advantage of the structural properties of CdS that allow it to.
+ Soil. + Soil Questions (1) What is soil? (2) What are the physical characteristics of soil? (3) What is the chemical composition of soil? (4) How do.
Fatigue behavior of the foam Load and displacement are monitored throughout the test at a rate of 150Hz. The data collected are then analyzed using a custom.
Space and Naval Warfare Systems San Diego (SPAWAR) is the US Navy’s research, development, test and evaluation, engineering, and fleet support center for.
Chapter 16 Tool Marks By the end of this chapter you will be able to:
Advanced FE-SEM : from Nano-imaging to Chemical and Structural Analyses Chi Ma Division Analytical Facility Division of Geological and Planetary Sciences,
Scanning Electron Microscope (SEM)
Trace Evidence. Trace evidence- small pieces of material –Debris from mass produced materials –Abundant in nature.
TOPIC D: SPECTROMETRY AND SPECTROSCOPY. Mass spectrometry is used to detect isotopes. mass spectrometer uses an ionizing beam of electrons to analyze.
Mass Spectroscopy 1 Mass Spectroscopy (Mass Spec) Applying Atomic Structure Knowledge to Chemical Analysis.
Other modes associated with SEM: EBIC
Forensic Application of Fluorescence
Metabolomics Metabolome Reflects the State of the Cell, Organ or Organism Change in the metabolome is a direct consequence of protein activity changes.
7-1 PRENTICE HALL ©2008 Pearson Education, Inc. Upper Saddle River, NJ FORENSIC SCIENCE An Introduction By Richard Saferstein THE MICROSCOPE Chapter.
-Arabidopsis thaliana is a member of the Brassicaceae family that can be found nearly worldwide (TAIR, 2008). -Ecotypes of A. thaliana have been shown.
Haifeng Huang and Kevin K. Lehmann
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
Electron probe microanalysis Low Voltage SEM Operation Modified 9/23/10.
X-ray microanalysis in the electron microscope
Example of the output produced by XRF
Let the evidence speak for itself.
A confocal Raman microprobe analysis of partial discharge activity in gaseous voids N A Freebody 1*, A SVaughan 1, G C Montanari 2 and L Wang 2 1 University.
Chromatography and Instrumentation. Chromatography Separate Analyze Identify Purify Quantify Components Mixture Chromatography is used by scientists to:
11-1 PRENTICE HALL ©2008 Pearson Education, Inc. Upper Saddle River, NJ FORENSIC SCIENCE An Introduction By Richard Saferstein Forensic Geology The.
Objective  To develop methods for analysis of compounds in organic aerosol particles Why is this important?  Environmental impact  Alternative fuels.
Characterization of Coal Ash by Materials Science Techniques R. J. Lauf Metals & Ceramics Division Oak Ridge National Laboratory.
Plasma Processing of Niobium SRF Cavities Janardan Upadhyay Department of Physics Center for Accelerator Sciences Old Dominion University Norfolk, Virginia.
Microscopes. Tools of a Biologist Light Microscopes: –Simple Microscope (Single Lens- Magnifying Glass (1600s) –Inventor:
Collecting and analyzing evidence
Improvements on an ATR-IR Spectrometer
Unit 3: Impression Evidence tool marks
FORENSIC SCIENCE.
Particle Composition and Respirable Crystalline Silica Concentrations in Sand Mining and Processing Facilities Joe Oster, Junyi Zhang, Callie Fischer.
Scanning Electron Microscopy
Chapter 3 Forensic Laboratory Techniques
Department of Tandem Accelerators
Chapter 16 Tool Marks By the end of this chapter you will be able to:
Introduction to Scanning Electron Microscope by Sameer S
METALLURGICAL MICROSCOPE
NANO 230 Micro/NanoFabrication
Soil Notes EQ: How do forensic geologist analyze soil evidence?
Synthesis and Characterization of ZnO-CdS Core-Shell Nanohybrids by Thermal Decomposition Method and Studies on Their Charge Transfer Characteristics Rama.
Louise Fortunato, Sulaf Assi, Paul Kneller and David Osselton
WEAR DEBRIS ANALYSIS 9/20/2018.
Chapter 16 Tool Marks By the end of this chapter you will be able to:
TOOL MARKS.
The Forensic Analysis of Hair
Chapter 3 Forensic Laboratory Techniques
Lead Transformation to Pyromorphite by Fungi
Introduction A tool mark is any impression, abrasion, or cut made when contact occurs between a tool and an object. Tool marks are a good example of physical.
Sci-101 Introduction to Physics
Presentation transcript:

Acknowledgments The authors would like to thank Dr Michael Norton for providing accessible and well equipped microscopy facilities, supported in part by NFS COBRE grant (period ). We also appreciate the help of Dr. Graham Rankin with the PCA analysis and Dennis Ward with guidance on sample preparation. Introduction Matches can be found at a variety of crime scenes: arsons, bombings, clandestine labs, and so forth. A technique capable of comparing a match found at a crime scene to a book of matches found in a suspect’s possession would be valuable in associating the suspect to the crime scene. Andrasko 1 used SEM/EDS to identify burned matches, and Dixon 2 used the fibers in book matches to identify a match originating from a specific book. SEM/EDS analysis has also been used to analyze unburned matches, but not to distinguish one producer from another. Materials and methods SEM/EDS Parameters A JEOL 5310 LV scanning electron microscope with an Oxford Pentafet electron dispersive spectrometer detector with thin beryllium window and ISIS analysis package was used. The settings used were: 300 mtorr low vacuum, 25 keV acceleration voltage, 24 mm working distance, and 109 mAmps condenser lens current (spot size). To ensure the spectra reflected the real composition of the matches and not just a few particles in the match, a magnification of 350x was used. A live time of 300 seconds was used as the collection time of each sample. Sample Preparation Matches produced by seven different match companies were analyzed. A list of the companies along with the samples corresponding to those match producers can be seen in Table 1. The samples were prepared by two methods. The second method produced a more homogenous sample. Preparation Method 1 A razor blade was used to cut a flake of the match head from the match. This flake was then placed between two microtome blades and pressed flat with a minimum pressure of 50 psi. Samples from five different matches of the same book were prepared for all seven match producers. Results A spectrum was collected from five matches from each book for all seven match producer (ex. A1a ─ Ale). The major elements in all the matches were the same (silicon, sulfur, chlorine, and potassium), But spectra were visibly different based on relative amounts of major and trace elements. Conclusions The spectra of some matches showed a visible difference in the amount and types of elements. These differences ranged from large variability in the amount of major elements to the presence or absence of trace elements. Even with the visible differences in many spectra, the variation in each match producer set made comparisons impossible. With the second method of sample preparation the particle size was significantly smaller. Thus, the homogeneity was improved and variations within a set reduced. While it has been shown that even with the second preparation method some matches are not distinct from others, groups of certain match producers may be distinct from other groups of match producers. Future work would include preparation of sample for the other five match producers using the second preparation method. These could then be analyzed by the SEM/EDS. The PCA analysis would then show if groups of match producers differ from other groups. Elemental Analysis of Unburned Matches by SEM/EDS for Forensic Comparison Lance Allen 1, David Neff 2, Catherine G. Rushton 1 1 Forensic Science Program and 2 Chemistry Department, Marshall University, Huntington, West Virginia Literature cited Andrasko, J. Identification of Burnt Matches by Scanning Electron Microscopy. J. Forensic Sci. 1978, 23, Dixon, K.C. Positive Identification of Torn Burned Matches with Emphasis on Crosscut and Torn Fiber Comparisons. J. Forensic Sci. 1983, 28, Figure 3. Lion Match Company sample (L1b) prepared by a flake of the match head cut off and pressed flat. Although the variation in each of the two sets (U1 and L1) decreased, the U1 samples still were not distinct from the L1 samples. This suggests reanalysis of all samples after being prepared by method 2 would reduce the variability in each set. Figure 4. Lion Match Company sample (Lig) prepared by entire match head being ground and pressed flat. Figure 1. Spectra of A1b, D1d, and L1e. Elements present are similar, but relative abundance differs. A large amount of variation can be seen in each set of match samples, thus not allowing for differentiation between one producer and another. Sample preparation method 2 was devised to improve uniformity of the sample, and reduce variation. Sample preparation method 2 was used to prepare more samples for U1 and L1. U1 was chosen because there was a large variability in the samples. L1 was chosen because the sample were similar to U1. It was hoped using preparation method 2 the U1 samples would have less variation and be distinct from the L1 samples. The particle size is much smaller in the sample ground with mortar and pestle (method 2), figure 4, than in the sample prepared by method 1, figure3. The ratios for the samples prepare by method 2 were used for more PCA analysis. Figure 2. Dendrogram of the PCA analysis. Shows the amount of dissimilarity between the samples. Figure 5. Dendrogram of the PCA analysis of samples prepared by method 2. Energy windows were used to calculate the integral values of eleven different elements. Relative abundance ratios were calculated from the integrals of each element in relation to potassium. These ratios were compared by Principle Component Analysis (PCA). Match ProducersSamples Atlas MatchA1a ─ A1e Atlantis MatchAT1a ─ AT1e DDBean & SonsDDB1a ─ DDB1e Diamond Match CompanyD1a ─ D1e Lion Match CorporationL1a ─ L1j Ohio Match CompanyO1a ─ O1e Universal Match CorporationU1a ─ U1j Table 1. Preparation Method 2 A razor blade was used to remove the entire match head from a match. The match head was ground with a mortar and pestle to homogenize the sample. This sample was placed between two glass microtome blades and pressed flat with a minimum pressure of 50 psi. Samples from five different matches of the same book were prepared for two of the match producers.