DESY, DEC-2013Ivo Polák, FZU, Prague1 Activity on Adaptive power & Calibration at Prague Ivo Polák, on behalf of Prague’s group QMB1A update.

Slides:



Advertisements
Similar presentations
STAR Pixel Detector Phase-1 testing. 22 Testing interrupted LBNL-IPHC 06/ LG Lena Weronika Szelezniak born on May 30, 2009 at 10:04 am weighing.
Advertisements

HH Dec 13Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group 1.QMB1.
Optical Fiber Calibration System and Adaptive Power Supply Jiri Kvasnicka, Ivo Polak, Jaroslav Cvach Prague, Institute of Physics Gerald Eigen,
CALICE WHCAL testbeam at SPS H8 27 sep – 03 oct: 6 days for energies up to 180 GeV (+ polarity)
SKIROC New generation readout chip for ECAL M. Bouchel, J. Fleury, C. de La Taille, G. Martin-Chassard, L. Raux, IN2P3/LAL Orsay J. Lecoq, G. Bohner S.
Introduction to Op Amps
LCWS2010, Beijing, 2010 MAR29 Ivo Polák, FZU, Prague1 LED notched fibre system at AHCAL Calibration system for SiPM Ivo Polák 1.Notched fibre.
Calice, UT ArlingtonJiri Kvasnicka, FZU, Prague1 LED notched fiber system Jiri Kvasnicka 1.Introduction 2.Test setup and fiber layout on HBU0.
Ivo Polák SiPM needs short optical pulses
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka, Ivo Polak Institute of Physics (FZU), Prague June 11, 2011TIPP 2011, Kvasnicka1 The.
ECFA, JUN10, 2008Ivo Polak, IPASCR, Prague1 Electronics part of AHCAL calibration system ECFA meeting at Warszawa.
EUDET, OCT8 - 10, 2007 Ivo Polak, IoP Prague1 A fast LED driver prototype for HCAL calibration EUDET annual meeting at Ecole Polytechnique, Palaisau.
External calibration system - QMB6 Distribution of light: Notched Fiber Calibration and Monitoring Board (CMB) 1-ch LED driver (QMB1) Calibration System.
Tests of the fiber-based calibration system CALICE collaboration meeting Cambridge, UK 2012/9/18 Jaroslav Zalesak Institute of Physics, Prague  QMB1 LED.
Performance of SPIROC chips in SKIROC mode
Mathias Reinecke CALICE meeting Argonne EUDET module – Electronics Integration Contents -Next prototype : architecture -HCAL Base Unit (HBU)
Feb 20, 2009 CALICE meeting, Daegu, Korea QRL in Magnetic Field 1 QRLed Driver in Magnetic Field Jaroslav Zalesak Institute of Physics of the ASCR, Prague.
Optical calibration system for EUDET AHCAL module Jaroslav Cvach IPASCR 1.Calibration system for SiPM photodetectors 2.QRLED driver photoelectron spectra.
AHCAL – Electromechanical Integration EUDET annual meeting – Paris Oct M. Reinecke.
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka Institute of Physics, Prague June 11, 2011TIPP 2011, Chicago1 Under.
LED calibration systems for CALICE hadron calorimeter
1 S. E. Tzamarias Hellenic Open University N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Readout Electronics DAQ & Calibration.
Laura Gonella ATLAS-CMS Power Working Group, 08/02/2011
Uni Bergen:G. Eigen, J. Zalieckas, E. van der Kraaij FZU Prague: J. Cvach, J. Kvasnicka, I. Polák CALICE meeting, Argonne, 19/03/2014.
2013 MAR 21Ivo Polák FZU Prague1 Tasks for AIDA SiPM Adaptive HV PSU AIDA subgroup Prague 2013 meeting Characterization of temperature influence to SiPM.
CALICE Annecy SiPM Adaptive HV PSU Ivo Polák & Jiří Kvasnička, J.Cvach Prague, Institute of Physics, Prague Erik van der Kraaij, Gerald.
Calibration UV LED system for CALICE scintillator based Tile Hadron Calorimeter Ivo Polák on behalf of the CALICE Collaboration Institute of Physics of.
Preliminary measurements for the 8 channel prototype of SPD discriminator ASIC I.The 8 channel prototype. II.Status of the test. III.Noise. IV.Gain. V.Test.
1 Fulvio TESSAROTTO CERN, 23/04/ Contribution from Trieste UPDATE ON TRIESTE LAB. ACTIVITY The set-up to measure currents THGEM prototypes from ELTOS.
LCWA, ALCPG 2009 Albuquerque, NM Ivo Polák, FZU, Prague1 Calibration system of CALICE AHCAL detector Ivo Polák 1.Two calibration light distribution.
CALICE ANL, MAR18, 2008 Ivo Polak, IPASCR, Prague1 A fast LED driver prototype for HCAL calibration CALICE meeting at ANL, USA.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Munich, 18 Oct 2006J. Cvach, annual JRA31 JRA3 Institute of Physics ASCR Prague 1.ECAL, VFCAL (V. Vrba) 2.HCAL (J. Cvach) 3.Exchange in NA2 (travels 8.5.
1. DESY tests 2. Electronics developments 3. Optical developments 4. Outlook Casablanca J. Cvach, CALICE Coll. meeting.
Montpellier, November 15, 2003 J. Cvach, TileHCAL and APD readout1 TileHCAL- fibre readout by APD APDs and preamplifiers Energy scan with DESY beam –Energy.
Uni Bergen:G. Eigen, E. van der Kraaij, J. Zalieckas FZU Prague: J. Cvach, J. Kvasnička, I. Polák Linear Collider Workshop, Tokyo 13/11/2013.
ANL, MAR-2014Ivo Polák, FZU, Prague1 Activity on Compass 2 detector with Calibration at Prague Ivo Polák, on behalf of Prague’s group Compass.
Two-stage amplifier status test buffer – to be replaced with IRSX i signal recent / final (hopefully) design uses load resistor and voltage gain stage.
HCAL – Integration Plans Mathias ReineckeHCAL – Main meeting Introduction 2.HCAL Base Unit (HBU) - Update 3.Testboards 4.Light Calibration System.
R&D for a 2nd generation AHCAL prototype LCWS 2007 – DESY Hamburg Mathias Reinecke on behalf of the AHCAL partners.
CARDIAC meeting – 30 Sept 05 M3R3-M5R3-M5R4 FEE status.
May - 20Ivo Polák, FZU, Prague1 LED notched fibre distributing system Calibration system for SiPM Ivo Polák, on behalf prague’s group
5 July 2010Ivo Polák, FZU, Prague LED notched fibre distributing system Calibration system for SiPM Ivo Polák, Ji ř í Kvasni č ka
Trip-t testing progress report
oct - 6Ivo Polák, FZU, Prague1 Calibration system for SiPM and LED notched fibre distributing system Ivo Polák, on behalf prague’s group
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka, Ivo Polak, Institute of Physics, Prague June 11, 2011TIPP 2011, Kvasnicka1 The CALICE.
Gain stability and the LYSO beam radiation monitor measurements
Visit to CALICE ECAL testbeam (by Shinshu) at DESY, 16 th – 19 th October 2012 Samir Arfaoui & Erik van der Kraaij 30 th October 2012.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
1 Calorimeters LED control LHCb CALO meeting Anatoli Konoplyannikov /ITEP/ Status of the calorimeters LV power supply and ECS control Status of.
Main HCAL, JUL1,2008Ivo Polak, IP_ASCR, Prague1 Calibration system with optical fibers HCAL main meeting, DESY.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
Status of the PSD upgrade - Status of the PSD cooling and temperature stabilization system - MAPD gain monitoring system - PSD readout upgrade F.Guber,
ShinShu, 2012 Mar 6Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 with HBU2 test Ivo Polák, on behalf of Prague’s group
2011 Sept 14-16Ivo Polák, FZU, Prague1 LED notched fibre distributing system QMB1 single LED slice Ivo Polák, on behalf prague’s group 1.QMB1.
Annual EUDET, OCT6,2008 Ivo Polak, IP_ASCR, Prague1 Calibration system with optical fibers for AHCAL EUDET annual meeting, NIKHEF 1.Introduction 2.QRLed.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
AHCAL Electronics. Status of Integration Mathias Reinecke for the DESY AHCAL developers AHCAL main and analysis meeting Hamburg, July 16th and 17th, 2009.
PADME Front-End Electronics
LED notched fibre distributing system Calibration system for SiPM
JRA3 Institute of Physics ASCR Prague
LED notched fibre system short HBU0 party with QMB6
Calorimeter Mu2e Development electronics Front-end Review
CTA-LST meeting February 2015
A fast LED driver prototype for HCAL calibration
LED notched fibre system at AHCAL Calibration system for SiPM
Felix Sefkow CALICE/EUDET electronics meeting CERN, July 12, 2007
BESIII EMC electronics
A fast LED driver prototype for HCAL calibration
Presentation transcript:

DESY, DEC-2013Ivo Polák, FZU, Prague1 Activity on Adaptive power & Calibration at Prague Ivo Polák, on behalf of Prague’s group QMB1A update Testboard ADApower PCB Test results with regulator prototype by Erik Conclusions

DESY, DEC-2013Ivo Polák, FZU, Prague2 QMB1(A) Quasi resonant Main Board –Modular system, 1 LED per board –Operation mode: DAQ + CANbus control stand-alone mode –LVDS Trigger distribution system –Variable amplitude, zero to maximum (~1Amp) smooth –Pulse width fixed to ~ 3.5ns STD (UV or blue LED) or ~30ns LONG pulse version (external inductor) –Voltages and temperature monitoring –Size of PCB: width 30mm, depth 140mm More info of QMB can be found at previous presentations: Polak_I.CALICE_Heidelberg.pdf Single power 15V 65mA QMB1 Update In Autumn 2013 I tested a possibility of shortest LED pulse. QMB1 can get 1.6ns with very small loop (3mm dia) at inductor position. It is 1.75ns in QMB1A. The Limits are switching mosfet transistor (speed, input C & maximal operational voltage), the speed of a mosfet driver and also a layout. We tested 35ns version for Compass detector ECAL0.

DESY, DEC-2013Ivo Polák, FZU, Prague3 Testboard - breadboard of bias regulator (ADApower) At each temperature setting, also applied testboard. Board operates in 10V to 80V region. It regulates V bias with slopes of mV/K, according to the temperature measured near the SiPM (LM35). The Regulator is designed for usage of SiPM and also for a compensation of APD. (Vout to 430V) Gain Stabilisation of SiPMs

DESY, DEC-2013Ivo Polák, FZU, Prague4 First ADApower testboard Jiri KvasnickaLCWS 2013, November 11-15, Tokyo4 LM35D temp sensor 10 mV/°C Switches for configuration Slope & bias trimming Rough & fine V Ref. OpAmps HV part 2m cable to temp. sensor Temp monitor Fully functional Complete Results: see talk by Gerald or Erik

DESY, DEC-2013Ivo Polák, FZU, Prague5 Layout of ADApower board ADApower is an acronym for Adaptive power supply for biasing SiPM with temperature compensation. The PCB is in production phase. We ordered 6 units. Size is 14 x 12cm

DESY, DEC-2013Ivo Polák, FZU, Prague6 Notes to ADApower board ADApower first version is been designed and it will be build as stand-alone unit (box) - The box consists complete power supply with setting elements – Multiturns potentiometer – Vout setting (fine and coarse), Slope, – Switches: Slope polarity, Calibrations Later we are ready to update a design for miniaturised version for an integration to the detector prototype. It will be focused for SiPM operation – output bias voltage up to 80V  smaller components than 500V range for APD mode. Overall Vout stability is better than 100ppm, some parameters are far better. Used voltage divider resistors with Temp-coeff 25ppm/K. Internal Voltage reference LT1021 better than 10ppm/K (typicaly 3ppm/K) Input Voltage 100 to 500V for board, the box will be powered by 230VAC

DESY, DEC-2013Ivo Polák, FZU, Prague7 Validation of the SiPM bias compensation ‘Climate Chamber’ (Used for stress tests in CERN bondinglab) Accurate to 0.1C. Digital oscilloscope readout by laptop LV and bias voltage supply Pulse generator for LED SiPM + preamp + T-sensor + LED

DESY, DEC-2013Ivo Polák, FZU, Prague8 Temperature measurement 3 Pt1000 sensors: Nearby SiPM Inside black testbox Outside black testbox T set to 10, 15, 20, 25 & 30C. T SiPM ~ T SET + 0.4C Offset consistent over full range. Near to SiPM Inside testbox Outside testbox Near to SiPM Inside testbox Outside testbox

DESY, DEC-2013Ivo Polák, FZU, Prague9 Results of temperature scan/compensation with 3 types of SiPM Erik van der Kraaij (UiB) provides me with following slides. It is based on tests made at CERN with the prototypes of regulator (ADApower). Erik made the analyze of the data. The Effective Result with the testboard  With compensation  Without compensation

DESY, DEC-2013Ivo Polák, FZU, Prague10 Gain vs voltage for different temperatures – CPTA (#857) Each entry is the gain extracted from 50k waveforms From these distributions you fit a linear function, which results in a breakdown voltage and a dG/dV Clear systematic dependence is visible for dG/dV (see below). 0th order polynomial fit yields: dG/dV = (4.32 ± 0.01 stat ) × 10 5 /V 1st order polynomial fit yields: dG/dV = (4.41 ± 0.11 sys ) × 10 5 /V

DESY, DEC-2013Ivo Polák, FZU, Prague11 Gain vs temperature for different V – CPTA (#857)  Same data as previous slide. Different fitted slopes  0th order polynomial fit yields: dG/dT = (-5.76 ± 0.02 stat ) × 10 3 /K For a constant gain: dV/dT = / = ± 0.35 mV / K Expected gain stability: σ(dV/dT)/(2G × dG/dV) = 0.12%

DESY, DEC-2013Ivo Polák, FZU, Prague12 Gain vs T – taken with breadboard CPTA (#857) With the breadboard the voltage was continuously adapted. The color coding in this plot only give the range of voltage applied. For example: blue means < V bias < V At each temperature about 10 samples were taken (each 50k events). For each sample you obtain one gain value. Linear fit to all data points offset: (6.71 ± 0.02) x10 5 slope: ± / K Gain is uniform in range of 5°-40° C Measured non-uniformity in 20-30C range: < ±0.01%

DESY, DEC-2013Ivo Polák, FZU, Prague13 Gain after V bias adjustment for other SiPMs AHCAL meeting - 09/12/'13 CPTA 1677 Non-uniformity ~ ± 0.1% (20°C < T < 30°C) Hamamatsu Non-uniformity ~ ± 0.5% KETEK W12 Non-uniformity < ± 0.3%

DESY, DEC-2013Ivo Polák, FZU, Prague14 Conclusion on SiPM Gain stabilization analalyze dV/dT is similar for CPTA & KETEK (15-20 mV/K) Hamamatsu sensors yield larger values ~55 mV/K For CPTA & KETEK (Hamamatsu), the maximum voltage adjustments are less than ΔV=0.7 (1.9) V for range 5°C < T < 40°C The gain stabilization with the V bias regulator prototype works well. Non-uniformity of gain vs T after compensation is better than ±0.5% for all detectors (20°C < T < 30°C) Dependence of dG/dV (=capacitance) on the temperature is visible for some of the SiPMs. – For temperature range of interest, dV/dT is approximately linear. AHCAL meeting - 09/12/'13 Erik van der Kraaij (UiB)14

DESY, DEC-2013Ivo Polák, FZU, Prague15 Conclusions Bias regulator (ADApower) is tested successfully with several SiPM types –It is working stable, even breadboard (prototype) is reliable and proved principals of gain stabilization –Production of 6 units is ongoing –Gain stabilization system can be used also for APD Analysis is ongoing, presented preliminary plots We will repeat the temperature scan with ADApower box Later an Upgrade to miniature SiPM version according to requirements to integrate to detector.

DESY, DEC-2013Ivo Polák, FZU, Prague16 Back-up slides

DESY, DEC-2013Ivo Polák, FZU, Prague17 Temperature sensor coupling Jiri Kvasnicka17

DESY, DEC-2013Ivo Polák, FZU, Prague18

DESY, DEC-2013Ivo Polák, FZU, Prague QMB1 linearity, amplitude scan Standard LED pulses 3ns, PWR measured by optical power meter ThorLabs PM100D Differential Nonlinearity Approved in december 2012 as well.