WHAT’S in the PIPELINE? Tobias van Reenen CSIR

Slides:



Advertisements
Similar presentations
Where to Sample?. Objectives Environmental Sources of Legionella Determine Sources to Sample Tools Needed for Sampling How to Sample.
Advertisements

Legionella management in the hospitality industry Mrs A Ferrero Environmental Health Officer East Devon District Council.
2 3 Risks are present whenever people are in contact with:  Natural or organic materials  Substances of animal origin  Food and food products  Organic.
1 F OOD S AFETY ON THE G O 2012 E DITION. Module 5: Drivers (staff and volunteers) 2.
LEGIONELLA DAVID CONSIDINE. WHAT IS LEGIONELLA Legionella pneumophila is the bacterium associated with over 90% of all cases of legionnaires disease.
LEGIONELLA MANAGEMENT & CONTROL NUQPR024 V
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Health and Safety Manual Section L6 Legionella. Legionella L6 is a single set of standards for the management of Legionella bacteria, based on the HSE.
Legionnaires’ disease – The hidden killer in water systems Managing the Risk presented by Karl Collingwood Wednesday 26 February 2014.
Preventing nosocomial water- borne infections by controlling water and water systems. Leif Percival Andersen Head of Infection Control Copenhagen University.
Waterborne Pathogens: Bacteria February 9 th -11 th, 2010.
Legionella control in the University of Sheffield Legionella Awareness for Departmental representatives.
©2006 Armstrong International, Inc. Legionella. What is it and how do we treat it?
Legionnaire Disease and Healthcare Facilities Healthcare Facilities Management Society of New Jersey May 21, 2009 LINDEN E. WITHERELL, P.E., M.P.H., J.D.,
Heat Transfer Equations For “thin walled” tubes, A i = A o.
LEGIONELLA AWARENESS COURSE. COURSE OBJECTIVES To enable you to be aware of issues associated with Legionella within the UoP & be able to assist in the.
Heating Systems.
1 CHCOHS312A Follow safety procedures for direct care work.
SHE Code 38: Control of Legionella Safety, Health and Environment (SHE) Group.
LEGIONELLA AWARENESS SEMINAR for the NORTH WEST WALES HEALTH AND SAFETY GROUP by Ken Ashley formerly HM Specialist Inspector HSE Dangerous Pathogens Section.
IOSH Essex Branch Event Event Subject: Legionella Awareness Date: 8 December 2010.
Water/Sanitation Yuriko Kubota. Nature of Water Composition of fresh water: 69.56% is frozen, 30.06% is groundwater, and the rest is lakes, soil moisture,
Health and Safety Executive Health and Safety Executive LEGIONNAIRES’ DISEASE AND GAS SAFETY: Landlords’ responsibilities Sue Matthews HM Inspector of.
Elizabeth Medlin, M.PH. Global Water, Sanitation, and Hygiene Team Environmental Health Services Branch U.S. Centers for Disease Control and Prevention.
Heat Transfer Equations For “thin walled” tubes, A i = A o.
Mine Health & Safety Inspectorate Northren Cape Region – May 2014 MH Sease - IOM.
1 LEGIONELLA PREVENTION Chemical free. 2 Agenda The legionella challenge A solution – By Wallenius AOT The technology Performance Installation Summary.
Legionella Awareness East Anglia Construction Safety Group 23 April 2009.
New Rules on Legionella Prevention N. Bangert TS Workshop 2005, Archamps.
Legionella and plumbing systems. Legionnaires' disease The first recognized cases of Legionnaires' disease occurred in 1976 in Philadelphia, Pennsylvania.
Legionella Control & Management by Rami E. Kremesti M.Sc.
Joanne Withers Infection Prevention & Control Nurse Infection Prevention and Control – Audit and Mandatory Training Workshop.
“Working Together” March 2010 Safety Management within the Timeshare Industry Miles Kirkwood.
Legionella Awareness Phil Land H 2 O Chemicals Ltd 11 May 2011.
The aerosols released from a domestic spa pool: the potential risk to those in and around the pool BISHTA Annual Conference: 29 th September 2015 Ginny.
Kate Brierley Nurse Consultant in Health Protection Cumbria and Lancashire Health Protection Unit NW Regional Lead for HCAI March 2012 Legionella in Residential.
It’s all about the water !. WHAT HAPPENS WHEN THE GLASS IS EMPTY? “when people see the change they believe, when they only listen they don’t believe”
Water Hygiene SH8 Lee Stuckey.
Water Quality & micro-organisms
Copyright © 2017 American Academy of Pediatrics.
Risk Assessment should include:
Module 2: Safe Cooking with Confidence
Legionnaires Disease Prevention:
HWAT Revival Special focus on hospitals Hygiene Flexibility Economy.
Safety and Sanitation - Serv Safe Review
Treatment – Chlorine Disinfection
Nalco Water Safety: The Broader Picture Scott Projahn – Senior Water Safety Consultant.
Safety Moment Health.
Legionnaires' Disease in Cooling Towers vs Ozone
Water management Program to reduce the risk of legionella growth
Control of Legionella in hot and cold water systems
Legionella & Backflow Kelvin Slade Chair.
5508BESG Services and Utilities Lecture 2
Module 2: Safe Cooking with Confidence
SHE Code 38: Control of Legionella
Hot Water Systems Cylinders and Systems.
Module 2: Safe Cooking with Confidence
Legionnaires’ disease
Module 2: Safe Cooking with Confidence
Module 2: Safe Cooking with Confidence
Energy Conservation Through the Removal of Bio-film
Treatment – Chlorine Dioxide
Session 7: Problems with Ships
Session 4, Activity 2: Slides for interactive work
Water Quality Maintenance – for the prevention of Legionella
CIC Questions January 25, 2019.
Karla Peterson, P.E. | MDH DWP
© 2017 SPX Cooling Technologies, Inc. All Rights Reserved.
Session 8: Risk Assessments and Water Systems
Safety, Sanitation, Workplace Safety and First-Aid
Presentation transcript:

WHAT’S in the PIPELINE? Tobias van Reenen CSIR Building Design and Engineering Approaches to Airborne Infection Control WHAT’S in the PIPELINE? Tobias van Reenen CSIR

OVERVIEW BACKGROUND STANDARDS & LEGISLATION DESIGN MANAGEMENT 2

BACKGROUND LEGIONELLA:- Mesophilic Bacteria naturally occurring in low numbers in aquatic environments Thrives in man-made water distribution and storage systems (20-50°C) ~ Half of the species cause Legionellosis Legionella Pneumophila is responsible for 90% of cases Within endemic regions, about 4% to 5% of pneumonia are caused by L. pneumophila -Robert-Koch-Institut Legionella Pneumophila can also be divided into sub groups. These sub groups are referred to as Sero-Groups. There are 16 different Sero-groups of Legionella Pneumophila, and Serogroup 1 is associated with most cases of Legionnaires Disease (it is also associated with the majority of fatalities from Legionnaires Disease, but not all).

BACKGROUND LEGIONELLA PNEUMOPHILA:- >70 °C : Disinfection range At 66 °C  : Legionellae die within 2 minutes At 60 °C  : They die within 32 minutes At 55 °C  : They die within 5 to 6 hours 50 °C  : They can survive but do not multiply 35 to 46 °C : Ideal growth range 20 to 50 °C : Growth range Below 20 °C : They can survive but are dormant

BACKGROUND LEGIONELLA PNEUMOPHILA:- 35 to 46 °C : Ideal growth range 20 to 50 °C : Growth range Legionella coincidently likes water at the same temperatures that we do.

BACKGROUND LEGIONELLA RISK ENVIRONMENTS Cooling towers and evaporative condensers Hot and Cold water systems especially showers Spa baths Water Features / Fountains Machinery Spray-Cooling Systems Water misting systems HVAC Systems Emergency Showers & Fire Hoses Sprinkler systems and hose reels Portable room humidifiers In other words “do nothing”

BACKGROUND BACKGROUND Biofilm:- a thin layer of microorganisms adhering to the surface of a structure, which may be organic or inorganic, together with the polymers that they secrete –http://medical-dictionary.thefreedictionary.com Biofilm development can result in cyclical system contamination, complicating trouble-shooting

BACKGROUND 4 EASY STEPS TO CONTRACTING LEGIONELLOSIS Contamination & Colonisation of Water Systems Growth & Proliferation Aerosolisation Inhalation Exposure (Duration x Susceptibility) In other words “do nothing”

STANDARDS & LEGISLATION STANDARDS & LEGISLATION SOUTH AFRICA:- Occupational Health and Safety Act, 1993 Regulations For Hazardous Biological Agents – pg24 SANS 11731: - Detection and enumeration of Legionella Act No. 36, 1998 National Water Act Act No. 108, 1997 Water Services Act SANS 893 (1&2) Risk Management and Control of Legionella in Water Systems (Committee Draft for Comment)

DESIGN Biofilm colonises stagnant or low-flow water in piping. Legionella risk increases with over-supply of Hand Wash Basins Over-use of alcohol based hand sanitizers = stagnation in unused basins (Dead Legs) DESIGN Avoid stagnation of water at the wrong temperatures!

DESIGN Avoid “dead legs” in distribution piping and fittings. A “dead leg” is a leg length >2x the diameter of the piping. DESIGN WHO Supplementary Training Modules: Validation, Water, Air Handling Systems - Water for Pharmaceutical Use (Part 2): Water Purification Engineering

DESIGN Point-of-use “RO filters” ? Filters eradicate concentrate organisms Point-of-use carbon filters? Breading grounds for Bio-film Aerosolizing/ Low flow faucets? Increase inhalation risk Pillar taps? Open standing dead-legs Automatic Faucets? Internal bio-film Maintenance burden http://www.shea-online.org/View/ArticleId/71/Electronic-Faucets-Unsafe-for-Use-in-High-Risk-Patient-Hospital-Settings-Study-Shows-Automatic-Fauce.aspx DESIGN

DESIGN Avoid warm water circulation or storage Keep COLD loops <20°C Keep HOT loops >55°C Avoid storing too much water Use of many smaller cisterns reduces stagnation Avoid long pipe runs Longer runs = Greater heat gain in cold water systems Greater heat loss in hot water systems Cisterns should be insulated from heat sources DESIGN

DESIGN Mixing devices should provide 55°C at upper limit of range A geyser is the “gatekeeper” to your distribution system. >55°C prevents colonisation of HW systems. Geysers should be set to 60°C Solar geysers can fail to maintain >45°C year round. DESIGN

MANAGEMENT 1. Risk Assessment and Management Plan Identify Risks Hygiene risks Safety risks (>55°C water) Operational protocols Thermostatic mixing Define competency and responsibility (Hygiene & Safety) Planners, Designers & Operators Implement program MANAGEMENT

MANAGEMENT 2. Disinfection Poor Water Supply Quality? Dispersive Disinfection Chlorination Free Chlorine Chloromines Chlorine Dioxide Silver & Copper ionisation Thermal Pasteurisation Site Disinfection Ozone & UV Not effective with downstream colonies MANAGEMENT Free chlorine may be associated with the formation of carcenogens in the presence of natural organic residues Ionisation can result in pitting corrosion

MANAGEMENT 3. Maintenance and Cleaning Develop and Implement Cleaning program Maintenance Policy Record keeping 4. Training, Monitoring and Review Training & Skills Matrix Develop monitoring program Updated asset register Effective logbook Engineering Change Control Safety and Hygiene Risks MANAGEMENT

REFERENCES & FURTHER READING http://www.ecosafe.co.za/legionella-background-information Water Systems: HTM 04-01 The control of Legionella , hygiene, “safe” hot water, cold water and drinking water. Part A & B ASHRAE White Paper : Position Paper on Legionellosis, 1995 World Health Organization – Legionella and the Control of Legionellosis – 2007 – ISBN 92 4 156297 8 SANS 893 (1&2) Risk Management and Control of Legionella in Water Systems (Committee Draft for Comment) REFERENCES