CHLORINE DI OXIDE.

Slides:



Advertisements
Similar presentations
Disinfection – Chapter 26
Advertisements

Analyze Immediately Residual Chlorine. Topics…. Background: Chlorine Chemistry Industrial Application NJAC Regulations Summary.
CM 4120 Julie King Original Presentation by Todd King and I edited it.
Sodium Hypochlorite & Ammonia Safety
COOLING SYSTEMS WATER TREATMENT TRAINING
NOx Control.
Chilled Water, Hot Water, Heat Pump and Glycol Loops
Anthium Dioxcide Presents The Future of Disinfection.
Using Disinfectants and practicing Sterilization in the Veterinary Clinic.
Disease Control Products for Stored Potatoes
CE 370 Disinfection.
Calcite Contactors for Corrosion Control
Control of Sulfur Oxides Dr. Wesam Al Madhoun
ENVE 201 Environmental Engineering Chemistry 1 CHLORINATION Dr. Aslıhan Kerç.
WQT 134 Environmental Chemistry II
Chlorination Chemistry; Considering Chloramines and Free Chlorine
Autonomous Vehicle Design Florida Tech AIChE 1999 P. Engel, T. McKenney, M. Mensch.
HOW DISINFECTION WORKS. Disinfection kills or inactivates living organisms that cause disease Oxidation destroys the physical structure of the organism.
1 Cooling Towers: Overview CM4120 Spring Topics Introduction Definitions Operating Conditions Basic Components Water Cooling Systems Types.
JTS SafGen UV-OX Chlorine Dioxide Generator. Background Chlorine dioxide has been used for over 100 years. It is more selective than chlorine or bromines.
Water Distribution Systems Water Quality Modelling for Civil Engineers 1 Helena M Jetmarova, GWMWater Helena M Jetmarova, GWMWater George J Kastl, MWH.
AQUA SILENCER SUBMITTED BY, JITHIN JOSE NO:18 S6 MECHANICAL.
XI. Swimming Pools & Bathing Beaches A. Regulations & B. Design and safety.
Introduction to Chlorine Dioxide Technology. Chlorine Dioxide is … Oxidizer and Disinfecting Biocide Molecular Formula – ClO 2 2/3 the oxidation potential.
Cleaning and disinfection a summary FS
Chemical BacComber Scale and Bacteria Control Comparison Between
Purposes of Oxidation u Removal of iron, manganese, sulfides u Removal of Taste & Odor u Destruction of color u Removal of synthetic organics –chlorinated.
Lesson 15 Heat Exchangers DESCRIBE the difference in the temperature profiles for counter-flow and parallel flow heat exchangers. DESCRIBE the differences.
COMMERCIAL REFRIGERATION
OXIDATION PROCESSES IN DRINKING WATER TREATMENT
Heat exchangers The device at which heat exchange between two fluids at different temperatures and separated by a solid wall occurs is called heat exchanger.
5.8 Disinfection Objective
Experts in Chem-Feed and Water Treatment Chlorine Chemistry.
Hypochlorous Acid and Dissociation
The Cooling System.
Sustainable Management Resources Inc Join SMRI as we work on: “Creating a Sustainable New Economy” SMRI, San Diego CA, ~ ~ Steve Kaplan ~
CORROSION:- TYPES EFFECTS & PREVENTION PRESENTED BY: GAUTAM AHUJA
Multi-Stage Flash Desalination (MSF)
How to obtain fresh water Section - E6.3 Chemistry 12 – SL Isabelle R.
Oxidation-Reduction (Redox) Reactions
Plan 2 – Dead-end Seal Chamber Optional Jacket
CTC 450 Review Water processing.
Reverse Osmosis Feed Treatment, Biofouling, and Membrane Cleaning
Reactions of chlorine with water and sodium hydroxide.
Physical and Chemical Control of Microorganisms. Control of Microorganisms by Physical and Chemical Agents.
WATER’S LIFE-SUPPORTING PROPERTIES. Water’s polarity leads to hydrogen bonding and other unusual properties The charged regions on water molecules are.
Environmental Engineering Lecture 7 Dr. Hasan Hamouda.
1 CE 548 II Fundamentals of Biological Treatment.
Chapter 13 Renewable Energy and Conservation. Overview of Chapter 13  Direct Solar Energy  Indirect Solar Energy  Wind  Biomass  Hydropower  Geothermal.
Chapter 12 Enzymes: The Protein Catalyst
Welcome to the Presentation of Plasma Based HNO3 Manufacturing Plant.
Introduction to Energy Management. Week/Lesson 9 part a Evaporative Cooling and Cooling Towers.
Perquat ™ technology Enhanced biocide and biofilm removal chemistry
Water Treatment: Disinfection Processes Current Technology vs. Alternatives.
Biochemical Reactions Chapter 1.3 McGraw-Hill Ryerson Biology 12 (2011)
ANLEC R&D COMMUNICATION PACK ( ). Trace emissions from Oxy Combustions do not pose significantly higher health, environmental or operational.
ANLEC R&D COMMUNICATION PACK ( ). While mercury can be removed from Oxy-Fuel flue gas, further work is required to understand its form and removal.
Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Investment vs Operating cost The average 800,000 ft² Property has $24,000, replaceable physical plant. The cost of water treatment is $ $0.04/
Introduction Results & Discussion At present, disinfection of wells and drinking water pipelines is carried out by treating with chlorine- containing reagents.
The importance of clean drinking water in animal production.
MICROBIOLOGICAL TREATMENT PROGRAMS FOR COOLING WATER
CTC 450 Review Water processing.
Heat Exchangers and Condensers
Boiler System Make-up Water Primary Secondary Pretreatment
Treatment – Chlorine Disinfection
CHLORINATION.
Energy Conservation Through the Removal of Bio-film
© 2017 SPX Cooling Technologies, Inc. All Rights Reserved.
Presentation transcript:

CHLORINE DI OXIDE

Cooling Water Treatment with Chlorine Dioxide:- Chlorine dioxide (ClO2) is effective as both a disinfectant and an oxidant in water treatment. Chlorine dioxide is a broad-spectrum micro biocide effective over a wide pH range. Unlike chlorine, chlorine dioxide does not react with organic materials to form trihalomethanes (THMs). Chlorine dioxide is also non-reactive with ammonia-nitrogen and with most treatment chemicals (corrosion and scale inhibitors) present in cooling water systems. Chlorine dioxide is effective in the control of microbiological growths in industrial cooling waters under conditions unfavorable to chlorine. It is particularly effective in systems having a high pH, ammonia-nitrogen contamination, persistent slime problems, or where the microbial contamination is aggravated by contamination with vegetable or mineral oils, phenols or other high chlorine-demand producing compounds.

Application Description:- A cooling system exists to remove heat from a process. This process may be a physical, chemical, or mechanical process. Heat is picked up by a recirculated fluid from a heat exchanger. From the heat exchanger the hot cooling water goes to the top of the cooling tower, shown in Figure 1, it is sprayed over the fill and slowly falls to the sump. The fan at the top of the tower induces a draft, which causes water evaporation and cooling. From the sump cool water is pumped back to the heat exchanger.

Cooling System Treatment:- Treatment of a cooling system has two basic objectives: to protect and extend the life of the cooling system and to insure good heat transfer and removal. Any fouling of the heat exchanger surface by scale, debris, or microbiological growth decreases the heat transfer efficiency. Corrosion destroys heat exchanger surfaces and causes leaks that result in mixing of the cooling water and the process fluid. Consequently there are three components to a cooling water treatment program: 1. Microbiological control, 2. Scale and deposit control, and 3. Corrosion control. The treatment program used for each component must be selected based upon its performance and its compatibility with the other treatment components. Microbiological control is arguably the most important portion of a cooling tower treatment program. Failure of the microbiological control program causes microbiological fouling, corrosion of metal, and rot of tower wood.

Microbial Treatment Alternatives:- Biocide products can be divided into two major groups based upon their mode of action: non-oxidizing biocides and oxidizing biocides. Non-oxidizing Biocides:- Non-oxidizing or organic biocides include dibromo-nitrilopropionamide, glutaraldehyde, quaternary ammonium salts and various organo-sulfur compounds. Organic biocides are diverse collections of chemicals that are typically slow acting and are slug-fed, i.e. added periodically to achieve high concentration, then allowed to decrease until the next addition. With this type of treatment the biocide is dosed to maintain a residual for an appropriate contact time to achieve an effective kill. Repetitive treatments allow those strains of bacteria that are fairly resistant to the biocides to predominate in a system.

Oxidizing Biocides:- The second group, the oxidizing biocides, includes chlorine (gas, hypochlorites, & chloro-isocyanurates) bromine (NaBr-NaOCl, & bromo-chloro-methyl-hydantoin), and chlorine dioxide. These biocides rapidly react with both microbiological species and chemicals present in the water. This reactivity is both the strength and weakness of these products. Rapid reaction with microbiological species means a rapid and effective kill; rapid reaction with chemicals means consumption of the product for other than microbiological control. Since chemical reactions are usually more rapid, only the portion of the product remaining after the chemical reaction is complete (demand) is available for microbiological control. The demand of the cooling water depends upon: 1. the level of microbiological growth in the cooling system, 2. chemical loading from process leaks, makeup water and the air, and 3. the chemistry of the product. Three oxidizing biocides dominate cooling tower treatment: chlorine, bromine and chlorine dioxide.

Chlorine:- Chlorine reacts with water to form hydrochloric acid and hypochlorous acid (HOCl), which is the most active biocidal form of chlorine. Likewise metal hypochlorites (MOCl) and chloroisocyanurates are chlorine sources that react with water to form hypochlorous acid. Cl2 +H2O  HCl + HOCl Consequently, the disinfection chemistry of all chlorine releasing species will be defined by the chemistry of hypochlorous acid. Hypochlorous acid reacts with bases to form hypochlorite ion (OCl-), which has only 1/20 to 1/300 of the biocidal activity of hypochlorous acid depending upon the organism tested. The percentage of hypochlorous acid and the consequent biocidal efficacy decrease with increasing water pH. The hypochlorous acid fraction drops from 79% at pH 7 to 28% at pH 8. Since many cooling towers operate near pH 8.0 for corrosion control, this response is significant.Chlorine also (in all its forms) reacts rapidly with ammonia and amines to form chloramines, which have 1% the biocidal efficacy of hypochlorous acid. In addition, many water treatment chemicals are attacked by chlorine. Among these are triazole corrosion inhibitors and the phosphonate AMP scale inhibitors along with other polymeric disinfectants. Finally in the presence of organic material chlorine can form harmful trihalomethanes (THM’s).

Residual = Dose - Demand Chlorine Dioxide: Chlorine dioxide’s chemistry is best summarized not by what it reacts with so much as by what it does not react with. Chlorine dioxide does not react with water nor does its chemical form or biocidal activity change with changes in pH. Chlorine dioxide also does not react with ammonianitrogen or most organic contaminants and treatment chemicals present in the cooling water. Consequently, the dosage required for biocidal control remains fairly constant over a wide range of cooling water conditions. This makes chlorine dioxide an excellent choice for cooling water that has a high pH, or that has high levels of organic or ammoniacal contamination.Chlorine dioxide is generally applied directly into the suction of the cooling system’s recirculating pump. Alternatively, it may be applied beneath the water in the sump as close to the pump intake as possible. Depending upon how critical the cooling system is, two different treatment schemes may be used: an intermittent treatment scheme and a continuous treatment scheme. Since both treatment schemes are based upon establishing a chlorine dioxide residual, to be effective the chlorine dioxide demand of the cooling water must be known. Typically the demand is determined over a 5 minute period. The relationship between chlorine dioxide demand, dose and residual is as Follows. Residual = Dose - Demand

Economic Comparison with other Biocides:- A comparison of chlorine dioxide and other oxidizing biocides should be conducted from the perspective of performance rather than on a cost per pound of chemical basis. When chlorine dioxide is scrutinized in this way, it becomes more cost competitive with alternative biocide programs, especially in systems, which operate at high pH or are contaminated with organics. The higher the contamination level the more economically viable chlorine dioxide becomes. For a clean system, the amount of chlorine dioxide required to treat a system would commonly be 1/4 to 1/5 of that of chlorine. For a contaminated system, the amount required may be as low as 1/20. Figure 2 gives an indication of chlorine dioxide economics versus the economics of other common oxidants based on system contamination.

Advantages of Chlorine Dioxide:- Chlorine dioxide is effective over a broad pH range. Chlorine dioxide does not react with organics to form THMs. Chlorine dioxide does not react with ammonia-nitrogen. Chlorine dioxide is effective at lower dose rates in contaminated systems compared to alternative biocides. Chlorine dioxide does not react with triazole corrosion inhibitors. Chlorine dioxide is very effective for biofilm and algae control. Chlorine dioxide may reduce the requirement for microbial control chemicals in the cooling water.

Feed Requirements:- For control of bacterial slime and algae in industrial recirculating and one-pass cooling systems, the required dosages will vary depending on the exact application and the degree of contamination present. The required chlorine dioxide residual concentrations range between 0.1 and 5.0 mg/L. Chlorine dioxide may be applied either continuously or intermittently. The typical chlorine dioxide residual concentration range is 0.1-1.0 mg/L for continuous doses, and 0.1-5.0 mg/L for intermittent doses. The minimum acceptable residual concentration of chlorine dioxide is 0.1 mg/L for a minimum one-minute contact time. For more information on dosage requirements specific to your application contact your service Representative.

Method of Feed:- Chlorine dioxide is a gas produced by activating sodium chlorite with an oxidizing agent or an acid source. Sodium chlorite is converted to chlorine dioxide through a chlorine dioxide generator and applied as a dilute solution. Chlorine dioxide solutions should be applied to the processing system at a point, and in a manner, which permits adequate mixing and uniform distribution. The feed point should be well below the water level to prevent volatilization of the chlorine dioxide. For more information on dosage requirements specific to your application contact your Siemens Representative.

Chlorine Dioxide Analysis:- Residual chlorine dioxide concentrations must be determined by substantiated methods, which are specific for chlorine dioxide. Two suitable methods are published in Standard Methods for the Examination of Water and Wastewater1: 4500-ClO2 D DPD-Glycine Method 4500-ClO2 E Amperometric Method II References:- Standard Methods for the Examination 1. of Water and Wastewater, APHA, AWWA and WEF, Washington, D.C. (20th Ed., l998).

Thank You

Steam Condenser Non-Optimized condition Air-in leaks Lower vacuum Lower Steam Flow Lower Vacuum Condensate Dirty Tubes Cooling Water Inlet Outlet Non-Optimized condition Air-in leaks Lower vacuum Dirty tubes Lower generation (MW) Higher fuel consumption Higher CO2 emission

Steam Condenser Optimized condition No air-in leaks (High vacuum) Higher Steam Flow High Vacuum Condensate Clean Tubes Cooling Water Inlet Outlet Optimized condition No air-in leaks (High vacuum) Clean tubes More generation (MW) Low fuel consumption Low CO2 emission

Condenser Tube Cleaning by Water Powered Cleaners (CONCO) Water Powered Gun used to push ‘bullets (scrapper)’ to clean condenser tubes; Most effective and low cost technology

Air-fuel ratio in Four Corners NON- UNIFORM Non optimum combustion Higher fuel consumption Higher CO2 Bad Flame Coal Pipes UNIFORM Optimum combustion Lower fuel consumption Lower CO2 Good Flame

Combustion Optimization