FLASH-B FLASH-B FLuorescent Advanced Stratospheric Hygrometer (for balloon and aircraft) Instrument design. Observations and comparison. Central Aerological.

Slides:



Advertisements
Similar presentations
Hygrometer Intercomparison Campaign at Sodankylä, LAUTLOS Jan 26-Feb 28, 2004 Esko Kyrö 1, Rigel Kivi 1, Juha Karhu 1, Timo Turunen 1, Tuomo Suortti 1,
Advertisements

Homogenization (instrumental correction) of water vapour data from Vaisala radiosondes and older (MARZ, RKZ) used in Polish aerological service Barbara.
1 This is the footer Ozone in the Tropical Tropopause Layer Geraint Vaughan What determines the ozone concentration in the tropical upper troposphere?
Holger Vömel NCAR Science Day 17 April 2015 Exploration of the tropical tropopause region during Strateole-2.
Characterization of the chemicals and water vapour distribution in the upper-troposphere lower-stratosphere from the M55 aircraft observations during the.
The stratospheric circulation Alan Plumb M. I. T..
Measured parameters: particle backscatter at 355 and 532 nm, particle extinction at 355 nm, lidar ratio at 355 nm, particle depolarization at 355 nm, atmospheric.
ISSI Working Group on Atmospheric Water Vapor, 11 Feb 2008 Holger Vömel Cooperative Institute for Research in Environmental Sciences University of Colorado.
Radiosonde and Hygrometer humitidy measurements at Sodankylä NDACC-H2O workshop, IAP, University of Bern July 5-7, 2006 Esko Kyrö, Tuomo Suortti, Rigel.
FMI’s special measurement sites - Jokioinen and Sodankylä 1)Basic infrastructure and routine operations 2)Special instrumentation and research Sodankylä.
NDAC H2O Workshop Bern 5-7 July 2006 Current activities and projects of water vapour measurements in the UTLS in France J. P. Pommereau CNRS Service d’Aeronomie,
FLASH-B FLASH-B FLuorescent Advanced Stratospheric Hygrometer (for balloon) Instrument design. Observations and comparison. Central Aerological Observatory.
Wuhu Feng and Martyn Chipperfield
SCOUT-O3 BALLOON/SONDES CAMPAIGN NIAMEY 26 JULY- 26 AUGUST 2006 J. P. Pommereau, A. Garnier and SCOUT-O3 team Objectives: Convective transport across tropopause.
Influence of tropopause-level disturbances on convection Geraint Vaughan.
Problems and measuring errors of radiosonde humidity measurements in the global aerological network and new possibilities of their correction and validation.
Liam Tallis. Introduction Know the vertical distribution of water vapour in the atmosphere Profile for input into radiative transfer schemes Need to know.
Possibility of stratospheric hydration by overshooting analyzed with space-borne sensors Suginori Iwasaki (National Defense Academy, Japan) T. Shibata.
GCOS Upper Air Workshop, 22 May 2006 Holger Vömel Cooperative Institute for Research in Environmental Sciences University of Colorado Water vapor observations.
HIBISCUS General Objective
Rigel Kivi (1), Holger Vömel (2), Franz Immler (2), Terhi Lehtola (3), Niklaus Kämpfer (4), Corinne Straub (4), Vladimir Yushkov (5), Sergey Khaykin (5),
Herman G.J. Smit/FZJ-COST723-WG-I Overview Noordwijk March 2004 COST723-WG1- Working Group I: Data and Measurement Techniques Overview Herman G.J.
GEWEX/GlobVapour Workshop, Mar 8-10, 2011, ESRIN, Frascati, Italy WATER VAPOUR RAMAN LIDARS IN THE UTLS: Where Are We Now? or “The JPL-Table Mountain Experience”
ENVISAT VALIDATION AT TROPICS J. P.POMMEREAU, A. GARNIER, F. GOUTAIL, F. BORCHI Service d ’Aéronomie CNRS, Verrières le Buisson, France A. HERTZOG and.
Using GPS data to study the tropical tropopause Bill Randel National Center for Atmospheric Research Boulder, Colorado “You can observe a lot by just watching”
Water vapour soundings in the upper troposphere Geraint Vaughan University of Wales, Aberystwyth With thanks to: Clare Cambridge, Alan Phillips, Les Dean,
MIR OZONE ISSUES Horizontal (STE) and vertical transport (long life time in UTLS) Photochemical production by precursors (biomass burning, lightning,..)
“Cold trap” dehydration in the TTL estimated from the water vapor MATCH Yoichi Inai, Fumio Hasebe and SOWER sonde team 18, 7, 2006.
Boundary layer temperature profile observations using ground-based microwave radiometers Bernhard Pospichal, ISARS 2006 Garmisch-Partenkirchen AMMA - Benin.
Non-hydrostatic Numerical Model Study on Tropical Mesoscale System During SCOUT DARWIN Campaign Wuhu Feng 1 and M.P. Chipperfield 1 IAS, School of Earth.
The Microwave Temperature Profiler (MTP) on START-08 MJ Mahoney - JPL/Caltech Julie Haggerty - NCAR Jan 9, 2008.
Herman G.J. Smit, COST 723, Bern, 6-7 Oct, MOZAIC-Data, Particularly the Use of Water Vapor Data for UTLS-Studies and the Urgent Need for Integrated.
Trimodal distribution of ozone and water vapor in the UT/LS during boreal summer Timothy J Dunkerton NorthWest Research Associates WARM SEASON.
In Situ Measurements of Ozone during Hibiscus 2004 Contributions through provision of data and discussions: Niels Larsen (DMI ozonesondes) Gerhard Held,
Niamey 23 Aug 2006 Local storms Ex of successful flight (1) Ice geysers and water vapour enhancements in the TTL 1500 m3 plastic balloon, 9 kg payload.
Canada’s Physical Geography Climate and Weather Part I Unit 2 Chapter 2.
PHAT-TACO Experiment On board ACES-23 Hannah Gardiner, Bill Freeman, Randy Dupuis, Corey Myers, Andrea Spring Science Presentation Team Philosohook.
Effects of wind uncertainties on understanding processes controlling humidity in the tropical tropopause layer Tim Miller, NASA/MSFC Jasna Pittman, NASA.
Bauru November 2004 Modelling interpretation of in situ H2O, CH4 and CO2 measured by  SDLA balloon borne instrument (SF2 and SF4 flights). N. Huret(1),G.
Hyperspectral Infrared Alone Cloudy Sounding Algorithm Development Objective and Summary To prepare for the synergistic use of data from the high-temporal.
Kunming campaign, first in situ observation of water vapor and ozone in the UTLS during the Asian summer monsoon Jianchun BIAN, and Hongbin CHEN LAGEO,
The lower tropospheric ozone increase over the eastern edge of the Indochina Peninsula revealed by ozonesondes at Hanoi, Vietnam Shin-Ya OGINO, Masatomo.
Meteorological Observatory Lindenberg – Richard Assmann Observatory (2010) GCOS Reference Upper Air Network Holger Vömel Meteorological Observatory Lindenberg.
SRL/Reference sonde P. Di Girolamo, D. Whiteman, B. Demoz, J. Wang, K. Beierle, T. Weckwerth The Reference sonde (C34) consists of a Snow White (SW) chilled-mirror.
AIRS science team meeting Camp Springs, February 2003 Holger Vömel University of Colorado and NOAA/CMDL Upper tropospheric humidity validation measurements.
Deutscher Wetterdienst Lindenberg Meteorological Observatory Richard Assmann Observatory Michael Sommer GRUAN Lead Centre, DWD 2 nd GRUAN Implementation.
Tropical Convection and UTLS Transport
AIRS science team meeting, Greenbelt, 31 March 2003 Holger Vömel University of Colorado and NOAA/CMDL Cryogenic Frost point Hygrometer (CFH) Measurements.
Instrumented Balloon Launches for ATTREX Dale Hurst, Emrys Hall, Allen Jordan Global Monitoring Division, NOAA Earth System Research Laboratory and CIRES,
High resolution models: Tropical Convection and Transport through the Tropical Tropopause Layer Maria Russo, Scott Hosking, Peter Braesicke, John Pyle.
EOS-Aura MLS Validation Using Radiosonde Profiles During the WAVES Campaign Cassie Stearns August 10,2006 Dr. Bojan Bojkov and Dr. David Whiteman, Advisors.
A U.S.-Japan Workshop on the Tropical Tropopause Layer
Henry B. Selkirk, USRA/NASA GSFC Holger Vömel, DWD Jorge Andrés Diaz, UCR Gary Morris, Valpo Univ. Acknowledgments: Sam Oltmans & Bryan Johnson, NOAA ESRL.
How Has It Been Conducted? How Has It Been Conducted? Campaign Basis Campaign Basis International collaboration (NOAA, INAMHI, LAPAN etc) International.
 Both chilled mirror devices lag the fast Ly-α TWC by an amount dependent on mixing ratio and phase of water on mirror. Facility for Airborne Atmospheric.
An Overview of the Lower and Middle Atmosphere
Challenges associated with ice and large particles in the TTL
Latmos UPMC/CNRS - ILRC 2015
G. Mevi1,2, G. Muscari1, P. P. Bertagnolio1, I. Fiorucci1
Jianchun Bian (IAP/CAS)
CAST – sonde activities
LATMOS-IPSL, CNRS/UVSQ
G. Mevi1,2, G. Muscari1, P. P. Bertagnolio1, I. Fiorucci1
Hygrometer Intercomparison Campaign at Sodankylä, LAUTLOS
EG2234 Earth Observation Weather Forecasting.
Water vapour as an indicator of dynamical processes in the extratropical UTLS inferred from balloon observations Sergey Khaykin (1), A. Lukyanov(1), V.Yushkov.
Jianchun BIAN, and Hongbin CHEN
Seasons and Atmosphere
Mobile GPS tracking system using STRATO
Can the increase of Polar Stratospheric Clouds explain the Antarctic Winter Tropospheric warming? Tom Lachlan-Cope (W. M. Connolley, J. Turner, H. Roscoe,
Presentation transcript:

FLASH-B FLASH-B FLuorescent Advanced Stratospheric Hygrometer (for balloon and aircraft) Instrument design. Observations and comparison. Central Aerological Observatory Khaykin S., Yushkov V., Korshunov L., Lukyanov A. ISSI”Atmospheric Water Vapour” Febr.2008 Bern

Aircraft FLASH-B uses closed optical cell Day&night time mesurements Balloon FLASH=B uses open optical cell Night time measurements Short balloon & long duration balloon ISSI”Atmospheric Water Vapour” Febr.2008 Bern

FLASH-B instrument ISSI”Atmospheric Water Vapour” Febr.2008 Bern

Source of VUV radiation h =121,6 nm (Lyman-α) Н2ОН2О Н( 2 S) ОН (А 2  + ) ОН (Х 2 П ) PMT Н 2 О + h  ОН (А 2  + ) + Н( 2 S) Fluorescense ОН (А 2  + )  ОН (Х 2 П) + h ’ Quenching ОН (А 2  + ) + N 2, О 2  products I fl – fluorescense intensity J - photodissotiation rate φ= 0,05 - quantum efficiency for excited OH production А=1,26  10 6 s -1 – Einstein coefficient, k q air. = 2,3  sm 3 s -1 – quenching coefficient of the excited OH in air 300 < λ < 330 nm at P > 7 hPa [H 2 O] I fl = S cal [ air]

Photomultiplier FLASH-B optical layout

Electronic block-layout of FLASH-B VUV lamp Lyman-alpha 1 KHz 121,6 nm H 2 O OH* 310nm Interference filter Photomultiplier P, T, U Receiver Modem PC OSC Lamp driver PMT power microcontroller VAISALA RS-80 radiosonde Synchrofilter Synchrodetector Data frame ISSI”Atmospheric Water Vapour” Febr.2008 Bern

Compressor FLASH-B Vacuum pump dehumidifierH 2 O bubbler flowcontroller homogenizer Reference dew point mirror hygrometer MBW 373L air out Calibration facility layout flow controller Vacuum chamber Pressure: hPa Temperature: C WVMR: ppmv

FLASH-B characteristics Range of water vapour measurements Response time Integration time Measurement precision Total uncertainty Temperature range Height range Required power Weight w/out batteries Interface card Radiosonde ppmv 0.2 sec 4 sec 5.5% 3 ppmv C … C 7… 35 km 9-30V, 10W max 0.5 kg Built-in (T-MAX type) Vaisala RS80-15 A(L) ISSI”Atmospheric Water Vapour” Febr.2008 Bern

Ny-Alesund Sodankylä Lindenberg Measurement sites since winter 2004

Intercomparison of FLASH-B and NOAA/CMDL hygrometers in the stratosphere Descent data only Mean difference in the 11,8 – 25,6 km range is: 2.6 ±3.1 % (1 σ) Large disagreement in the 8,8 – 11,8 km range is caused by the feedback gain change in the NOAA hygrometer

Comparison of in-situ balloon-borne and remote microwave water vapour measurements B. Deuber et al., 2005, JGR Comparison of MIAWARA (solid grey), NOAA(dashed black)/CU- CFH (dashed-dotted black) and FLASH-B (solid black) (balloon descent) profiles for different days. The black dots are measurements by NOAA/CU-CFH which were not considered due to remaining wet contamination from the ascent or instrumental failure. The balloon profiles were reduced to the microwave retrieval grid using the Curtis - Godson equation. The CU-CFH sonde was flown on Feb- 15 and Feb-25, on the other flights the older NOAA version was used.

Simultaneous humidity measurements in the troposphere during LAUTLOS 11 February 2004

Simultaneous humidity measurements in the troposphere during LAUTLOS 23 February 2004

Water vapour profiles inside, otside and at the edge of polar vortex during LAUTLOS campaign (Sodankyla, Jan-Feb 2004).

Water vapour soundings at the Arctic stations in 2006/2007

Water vapour soundings in the tropics in 2006 (SCOUT-AMMA)

SCOUT-AMMA balloon campaign. Local convection on 23 August Hydration of LS by ice geysers C-band radar cloud tops height at 16:51 UT on 23 August, two hours before the sounding from Niamey

NASA TC4 campaign, Costa-Rica, 10 0 N, August 2007 (sonde programme): simulataneous measurements of water vapour and ozone by FLASH-B and CFH hygro-sondes.

NASA TC4 campaign, Costa-Rica, 10 0 N, August 2007 (sonde programme): simulataneous measurements of water vapour and ozone by FLASH-B and CFH hygro-sondes. Comparison between FLASH-B and CFH H 2 O descent profiles Mean relative difference in the 10% range

Comparison between FLASH-B and ECMWF Arctic ISSI”Atmospheric Water Vapour” Febr.2008 Bern

Comparison between FLASH-B and ECMWF Tropics ISSI”Atmospheric Water Vapour” Febr.2008 Bern

incl. convection tropopause (17 km): cold point and cold trap SCOUT-O3 Darwin, Australia, 12 0 S, November 2005 H 2 O and O 3 measurements with FISH on board M55-Geophysica Courtesy of C. Schiller

SCOUT-O3 Darwin, Australia, 12 0 S, November 2005 H 2 O and O 3 measurements with FLASH and FOZAN on board M55-Geophysica 16 November Well mixed dry air between LRT and CPT CPT LRT No signs of hydration in LS above Hector Warmer T and higher O 3 in LS above Hector

SCOUT-O3 Darwin, Australia, 12 0 S, November 2005 H 2 O and O 3 measurements with FLASH and FOZAN on board M55-Geophysica H 2 O, temperature and O 3 profiles above Darwin No signs of hydration in LS above Hector Enhanced ozone inside Hector Dry and mixed TTL with H 2 O amounts controlled by saturation at CPT

Ice geyser hydration across the tropopause may be the dominant factor controlling water vapour at global scale in the stratosphere. Concluding remarks WVMR observations above Darwin do not show strong signatures of LS hydration above Hector H 2 O, O 3 and particles measurements above Africa during monsoon season strongly indicate that convective overshooting above continental region hydrates lower stratosphere Ice geyser hydration across the tropopause may be the dominant factor controlling water vapour at global scale in the stratosphere.

FLASH-B on board long duration super pressure balloon CNES SPB mission in Esrange, Kiruna, Sweden (March 2007) 1 st day of flight – contamination from the payload 5 th day of flight – dry payload, no contamination

FLASH-B on board long duration super pressure balloon CNES SPB mission in Esrange, Kiruna, Sweden (March 2007) 12 m 2 CNES SP balloon launched from Esrange on days flight around the pole inside vortex FLASH-B in the bottom of flight train 15 minutes measurements every 2 hours during night time Landing and recovery in Sweden

THANK YOU

Simultaneous humidity measurements in the troposphere during Scout-AMMA

Water vapour soundings at the Arctic stations in 2004/2005

FLASH-B water vapour observations in the presence of PSCs FLASH-B water vapour Temperature and PSCs thresholds Ny-Alesund (78,9 N, 11,9 E) 6 January 2005

lidarwater vapour FLASH-B water vapour observations in the presence of PSCs Ny-Alesund (78,9 N, 11,9 E) 26 January 2005