Teledyne Analytical Instruments

Slides:



Advertisements
Similar presentations
Gas Detection Instruments
Advertisements

Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
EPA Methods 3A, 6C, 7E, 10 & 20 Corrections to May 15, 2006 Final Rule That Updated the Methods That Updated the Methods Foston Curtis US EPA.
Teledyne Analytical Instruments
Modelling and Simulation 7. September 2014 / Dr. –Ing Naveed Ramzan 1 Instrumentation and control Department of Chemical Engineering, U.E.T. Lahore Pakistan.
E VERY L IFE H AS A P URPOSE… Chemgard TM Infrared Gas Monitor.
SO2 Precursor Gas Monitoring Training Overview
Problems With Determining Oxygen Deficiencies in Ratios Used for Assessing Spontaneous Combustion Activity Darren Brady Manager OHECC Simtars Department.
1 Comparison of Analog vs. Advance Technology Air Sampling System Designs To Facilitate Correction of Measured or Calculated Volumes to a Set of Reference.
AAQMS – DAS Requirements
AAS and FES (Ch 9, 7th e, WMDS)
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
Flame photometry.
Data Acquisition Risanuri Hidayat.
Representative Sampling By Chuck Abbott. Automatic Samplers.
EPA Precursor Gas Training Workshop NCore Calibration Issues Meeting the new QC Requirements Lewis Weinstock and Dennis Mikel EPA Office of Air Quality,
Finding That Elusive Pot of Gold or Networking Your Shelter Rebecca Peltzer & Jennifer Bradley, Polk County – Air Quality Steve Drevik, Agilaire.
AOSC 634 Air Sampling and Analysis Lecture 1 Measurement Theory Performance Characteristics of instruments Nomenclature and static response Copyright Brock.
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
Sensors used in EFI (Electronic Fuel Injection)
Teledyne Analytical Instruments TELEDYNE AAQMS Systems.
EPA Precursor Gas Training Workshop Kevin A Cavender EPA-Office of Air Quality, Planning and Standards Precursor Gas Monitoring NO y Monitoring Training.
Computer Process Control Application. Computer process control In computer process control, a digital computer is used to direct the operations of a manufacturing.
SCADA and Telemetry Presented By:.
Antek 6200 ® Meet Sulfur Regulations and Control Your Process with Continuous Measurements Product Presentation.
Introduction to Thermo Electron Instruments Robert Kinsella Sky Patton Thermo Electron.
Teledyne Analytical Instruments
CEMTREX, INC. MODCON SYSTEMS LTD NIR Systems July 2010.
Ensuring of Traceability
Teledyne Analytical Instruments TELEDYNE AAQMS Systems.
E VERY L IFE H AS A P URPOSE… Chillgard ® RT Refrigerant Monitors.
Static Electricity Electrical Charge: Is a concentration of electricity.
Smart transmitters.
Your analytical partner ! Company Introduction Company Profile: Experience Customers Products: Reducing Compound Photometer Flame Ionization Detector Span.
Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.
Continuous Particulate Monitoring Using Light Scatter Photometers.
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheWorkshop European Standards Requirements of.
Quality Control – Part II Tim Hanley EPA Office of Air Quality Planning and Standards.
1 Atomic Absorption Spectroscopy Lecture Emission in Flames There can be significant amounts of emission produced in flames due to presence of flame.
1 Atomic Absorption Spectroscopy Lecture Performance Characteristics of Electrothermal Atomizers Electrothermal atomization is the technique of.
Control System Instrumentation
Teledyne Analytical Instruments LGA 4000 Analyzer.
Calibration PT Honeywell Chapter 7 InstrumentationELC-213Today Presentation by Clifford T. Johnson, PE, Control Systems Engineer Honeywell Primer Auxiliaries.
N 2 O-Measurement Methods Folie 1 Nitrous Oxide/Laughing Gas Molar mass: 44,013 kg/kmol Gas density at 0°C and 1,013 bar: 1,9781 kg/m³ Gas density in relation.
Introduction to Spectrochemical Methods
Computer Hardware Basics
The Theory of Near Light Scatter
CHEM*3440 Operational Amplifiers These integrated circuits form the backbone of modern instrumental methods. Understanding their operation will help you.
“ELMIZ” PJSC was found in 1996 as a results of “Kyiv Radio Plant” restructuring according to the decision of the Cabinet of Ministers of Ukraine. The enterprise.
Photometry.
Balances The balance is an instrument which measures the mass of a body or substance using the gravity force which acts on that body At present, there.
Hygrometry Part 2.
1 Chapter 01 Measurement And Error. 2 Summary Instrument – a device or mechanism used to determine the present value of a quantity Measurement – a process.
F-900 PORTABLE ETHYLENE ANALYZER INSTRUMENT TRAINING
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
Electronic Control Unit (ECU)
UV/VIS SPECTROSCOPY.
Static Management Program (SMP)
Temperature sensors Temperature is the most often-measured environmental quantity. This might be expected since most physical, electronic, chemical, mechanical,
Control System Instrumentation
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Electronic Control Systems Week 4 – Signaling and Calibration
August 23, 2000 R.N. Dubois Dow Chemical
Control System Instrumentation
Control System Instrumentation
Static Management Program (SMP)
Spectrophotometry A method to determine concentration of a species exploiting the absorption of EMR.
Quality Assessment The goal of laboratory analysis is to provide the accurate, reliable and timeliness result Quality assurance The overall program that.
Measurements & Error Analysis
724 Temperature Calibrator
Presentation transcript:

Teledyne Analytical Instruments 4/20/2017 4:02 AM TELEDYNE AAQMS Systems TeledyneTech_101199_notes_6mo_3.ppt

Analytical Instruments for AQMS CO – GFC7001E NO2 – 9110E SO2 – 6400E VOC – 4060 Ozone – 400E Particulate Matter (2.5 & 10) – Beta Ray Attenuation Zero Air Generator – 701 Mass Flow Calibrator – 702E DAS – Win collect

O3 Ozone Analyzer – Model 400E The Model 400E photometric ozone analyzer is a microprocessor- controlled analyzer that measures low ranges of ozone in ambient air using a method based on the Beer-Lambert law, an empirical relationship that relates the absorption of light to the properties of the material through which the light is traveling over a given distance. The intensity of an ultra violate light is measured after it passes through a chamber, called the sample cell, where it is absorbed in proportion to the amount of ozone present. Every three seconds, a switching valve alternates measurement between a gas stream containing ozone and a stream that has been scrubbed of ozone. The analyzer also measures the ambient temperature and pressure of the gas being measured. Using results of these measurements and the Beer-Lambert equation, the M400E analyzer calculates the amount of ozone present in the sampler gas.

O3 Ozone Analyzer – Model 400E I=I0 exp(-αLC) at STP(standard temperature and pressure) Where: Io is the intensity of the light if there was no absorption. I is the intensity with absorption. L is the absorption path, or the distance the light travels as it is being absorbed. C is the concentration of the absorbing gas. In the case of the Model 400E, Ozone (O3). α is the absorption coefficient that tells how well O3 absorbs light at the specific wavelength of interest.

O3 Ozone Analyzer – Model 400E

O3 Ozone Analyzer – Model 400E UV Absorption Analyzer E P A APPROVAL EQOA - 0 9 9 2 - 0 8 7 Ranges: 0-100 ppb to 0-10 ppm, user selectable. Dual ranges and auto-ranging supported Units: ppb, ppm, μg/m3, mg/m3 Zero Noise: < 0.3 ppb (RMS) Span Noise: < 0.5% of reading above 100 ppb (RMS) Lower Detectable Limit (LDL):< 0.6 ppb (RMS) Zero Drift: < 1.0 ppb/24 hours, <1.0 ppb/7 days Span Drift: <1% of reading/7 days ozone present Lag Time: <10 seconds Linearity: 1% of full scale Flow Rate 800 cm3/min Sample Flow Rate: 800 cm3/min ±10% Temperature Range 5 - 40C Humidity Range 0-90% RH, Non-Condensing A 254 nm UV light signal is passed through the sample cell where it is absorbed in proportion to the amount of O3 present in Air.

400E O3 - Schematic

400E O3 - Schematic

400E O3 - Schematic

O3 Ozone Analyzer – Model 400E INTERNAL ZERO SPAN (IZS) OPTION (OPT 51A) The Model 400E photometric ozone analyzer can also be equipped with an internal zero air and span gas generator. This option includes an ozone scrubber for producing zero air, a variable ozone generator for producing calibration span gas and a valve for switching between the sample gas inlet and the output of the scrubber/generator. A reference detector monitors the operating level of the IZS’ ozone generator. The detector senses the intensity of the UV lamp internal to the IZS generator and coverts this into a DC voltage. This voltage is used by the CPU as part of a feedback loop to directly adjust the brightness of the lamp producing a more accurate and stable ozone concentration. The ozone output level of the generator is directly controllable by the user via the front panel of the instrument or remotely via the analyzer’s RS-232 Serial I/O ports.

O3 Ozone Analyzer – Model 400E THE DATA ACQUISITION SYSTEM (IDAS) The M400E analyzer contains a flexible and powerful, internal data acquisition system (iDAS) that enables the analyzer to store concentration and calibration data as well as a host of diagnostic parameters. The iDAS can store up to about one million data points, which can cover days, weeks or months of valuable measurements. The iDAS is designed to be flexible, users have full control over the type, length and reporting time of the data. The iDAS permits users to access stored data through the instrument’s front panel or its communication ports. The principal use of the iDAS is logging data for trend analysis and predictive diagnostics, which can assist in identifying possible problems before they affect the functionality of the analyzer. To support the iDAS functionality, Teledyne API offers APICOM, a program that provides a visual interface for remote or local setup, configuration and data retrieval of the iDAS

O3 Ozone Analyzer – Model 400E APICOM is very helpful for initial setup, data analysis, maintenance and trouble-shooting. The Figure below shows examples of APICOM’s main interface, which emulates the look and functionality of the instruments actual front pane

O3 Ozone Analyzer – Model 400E LEVEL 1 ZERO AND SPAN CALIBRATION A Level 1 zero and span calibration is a simplified, two point analyzer calibration used when analyzer linearity does not need to be checked or verified. Since most analyzers have a reliably linear or near-linear output response with concentration, they can be adequately calibrated with only two concentration standards (two-point concentration). Furthermore, one of the standards may be zero concentration, which is relatively easily obtained and need not be certified. Hence, only one certified concentration standard is needed for the two-point (Level 1) zero and span calibration. Although lacking the advantages of the multipoint calibration, the two- point zero and span calibration--because of its simplicity—can be (and should be) carried out much more frequently. Also, two-point calibrations are easily automated. Frequency checks or updating of the calibration relationship with a two-point zero and span calibration improves the quality of the monitoring data by helping to keep the calibration relationship more closely matched to any changes (drifts) in the analyzer response. (Linearity :The amount of error change throughout an instrument's measurement range. Linearity is also the amount of deviation from an instrument's ideal straight-line performance) 

O3 Ozone Analyzer – Model 400E LEVEL 2 ZERO AND SPAN CHECK A Level 2 zero and span check is an "unofficial" check of an analyzer's response. Artificial stimulation of the analyzer's detector, electronic or other types of checks of a portion of the analyzer, etc. Level 2 zero and span checks are not to be used as a basis for analyzer zero or span adjustments, calibration updates, or adjustment of ambient data. They are intended as quick, convenient checks to be used between zero and span calibrations to check for possible analyzer malfunction or calibration drift. Whenever a Level 2 zero or span check indicates a possible calibration problem, a Level 1 zero and span (or multipoint) calibration should be carried out before any corrective action is taken. Subsequent Level 2 check responses should then be compared to the most recent reference response to determine if a change in response has occurred. For automatic Level 2 zero and span checks, the first scheduled check following the calibration should be used for the reference response. It should be kept in mind that any Level 2 check that involves only part of the analyzer's system cannot provide information about the portions of the system not checked and therefore cannot be used as a verification of the overall analyzer calibration.

O3 Ozone Analyzer – Model 400E ELECTRO-STATIC DISCHARGE Modern electronic devices such as the types used in the various electronic assemblies of your analyzer, are very small, require very little power and operate very quickly. Unfortunately, the same characteristics that allow them to do these things also make them very susceptible to damage from the discharge of static electricity. Damage to components occurs when these static charges come into contact with an electronic device. Temporary anti-ESD work area Always wear an Anti-ESD wrist strap when working on the electronic assemblies of your analyzer. Simply touching a grounded piece of metal is insufficient. While this may temporarily bleed off static Always store sensitive components and assemblies in anti-ESD storage bags or bins

TELEYNE Team Thank you All Company Confidential TELEYNE Team Thank you All Company Headquarters: City of Industry, California USA Facility: 60,000 sq. ft. / ISO-9001:2008 Founded: 1945 Core Capabilities: Manufacturer of high quality measurement and control instrumentation. Website: www.teledyne-ai.com