Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate.

Similar presentations


Presentation on theme: "Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate."— Presentation transcript:

1 Bloodhound™ Logging System Infrared™ Hydrocarbon Analyzer System 0-100% auto ranging Total gas with Chromatograph model- C1-C4 iso and C4 normal Accurate and Sensitive with Auto Ranging Low end +/ -.0001% = one unit (on 10,000 unit full range) High end +/- 1 % full scale Reliability –No filament, flame or pellistor to fail –No saturation –No in field calibration (set and stable for 18 months) –No drift from filament degradation –No drift from carbonization CO2 - included O2 - included H2S - included DATA Triple redundant data records Real time (6 second new data capture cycle) data viewing at rig site or anywhere world wide via web site WITS compatible (can output or collect and display incoming drilling data) AUTOMATION Remote systems diagnostic capabilities Multiple function alarm system Automatically generated real time mudlog (just add lithology) Automatic sample flow monitor and adjustment COMMUNICATION Hardwire and wireless communication capabilities Built in GPRS data modem eliminates satellite dish and rental costs Alarm notification via cell phone text message world wide POWER Low operating current design (DC low voltage extends life and eliminates shock danger) Functional from 12v car electrical system Up to 120 min on board backup power supply (with monitor) MONITORING Remote diagnostics on sample flow, sample line vacuum pressure, total hydrocarbons and other functions Multiple function automatic alarms based on custom high low parameters Automatic alarm notification via cell text message 24/7 remote manned alarm monitoring service packages http://www.bloodhoundrentals.com

2 Bloodhound™ Logging System Side View Sample Gas inlet Port has regulated flow and vacuum pressure Exhaust port. ½” size keeps the line from freezing in cold weather Geolograph switch input GPRS Radio antenna Ethernet RJ-45 to Internet Audio Alarm Positive Pressure vent air supply. Inside case under positive pressure with filtered air. Analog Out Relay contacts for Depth & Alarms DC power in/out Runs from DC car adaptor or powers DC devices e.g. iBall Cavitator Universal AC power From 90-250VAC power and 45-65 Hz WITS Pason compatible RS422 interface WITS Null Modem Connection (9-pin FtoF) RS232 Straight-thru Personal Computer or External Data logger USB-B Serial (COM) PC connection (PC Driver Req’d)

3 Gas Charting Functions Calculates Lag Set PC Alarms Edit Depth Zoom on Chromats Data File Export Communication Network http://www.bloodhoundrentals.com Internet 64.19.xx.xx:xxxx Bloodhound ™ Data Archive Web Remote Gas Chart Web Browser Well Status via Mobile Device Access e.g. Voice Response – Text - Email GPRS Cell Radio AT&T Data Service Field Data Network Ethernet connection (e.g. Sat. Internet) Bloodhound™ Logging System Total Gas Gas Chromatography CO2 O2 H2S Local Instrument Alarms Serial Connection Instrument to PC At Well Site WITS WITs to EDR Gas Chart - Local Well Site PC Gas Chart - Remote Remote PC Gas Chart - Remote Remote PC

4 Data Logger Software Used both for Local & Remote Logging Application Logging software used Locally or Remotely Real-Time Data –Table (6 sec update) –Flexible Charting capability Configuration –Lag –Depth editing –Scale adjustments –Export LAS and XLS data file for importing to any Mudlogging software http://www.bloodhoundrentals.com

5 Web Remote Data Logger Accessible from any Internet connected browser Real-Time Data –Table 10 sec update –Chart Image 1 min update Comment Editing Capable http://www.bloodhoundrentals.com

6 Mobile Device Access Mobile Phones based on Windows Mobile http://www.bloodhoundrentals.com IPhone

7 Real-Time Data Viewer Sample Line Vacuum Pressure Great for troubleshooting leaks, blockages etc. Flow Rate Automatically controlled Variable Speed Sample Pump controls Flow Rate to Set Point RSSI Received Signal Strength Indicator Monitors Cell network signal http://www.bloodhoundrentals.com

8 Real-Time Data Viewer with WITS Stream Viewer

9 Multiple Well Real-Time Data Viewer

10 Website Multiple Instrument Viewer http://www.iballmultiview.com Accessible from any Internet connected browser Multiple Well Snapshot View –Real-Time Data –Table 10 sec update

11 24/7 Call Center Support (303-459-4660) Technical Support –Tier 1 call center agents available 24 hours a day, 7 days a week Interactive Voice Response (IVR) w/Text & Email –Voice Response - Available 24/7 for retrieving a voice response that recites individual Bloodhound Hole Depth, Bit Depth and Total Gas –Text Message - Available 24/7 for retrieving Hole Depth, Bit Depth, Total Gas, Sample line flow rate, Vacuum pressure and ROP in min/ft and ft/hr –Email – Available 24/7 by request with all Bloodhound diagnostic information Sales –Agents available during business hours