airQrate line of calibrators

Slides:



Advertisements
Similar presentations
Pocket PC – DSP Integrated System Gliwice February 13 th, 2009.
Advertisements

SARAtronic charging solution
Catalyst Chemical Injection Systems. Catalyst System Family.
Micro Control Solutions Stability System II rev. 6.4
Issues with low concentration gas detection in ambient air: Sub-ppm and ppb detection are not just business as usual.
Ljupcho Grozdanovski Division for air quality monitoring Ministry of environment and physical planning Prizren, July 2013 Air Quality support meeting,
Using the MiniRAE 3000.
ArbStudio Arbitrary Waveform Generators. ArbStudio Highlights  ArbStudio allows LeCroy to enter the signal generator market at the sub 5,000 € price.
Nordson Europe 3rd Generation Powder Coating Equipment
FREQUENCY CONTROL MODES OF ET 91 To learn more click on note! END to END Loss Measurement Group Delay Distortion Measurement Frequency Tracking with Sweep.
Project O.N.O.S.E. Optical Noxious Odor Sensing Electronics Capstone Preliminary Design Review Fall 2003.
Copyright Albion Devices, Inc., Demonstration of MicroComp micro-computer gaging system from Albion Devices, Inc.
Slide 1Reaction Analytics Inc. ©2011 “iFlow” Flow Analytics System Reaction Analytics Inc. Makers of the iChemExploreriChemExplorer.
EPA Precursor Gas Training Workshop NCore Calibration Issues Meeting the new QC Requirements Lewis Weinstock and Dennis Mikel EPA Office of Air Quality,
Gateplus Time Attendance and Access Control System.
Omni-Pro Software, Inc Internet Energy Systems, Inc. Load Management Advanced Automated Meter Reading SCADA & Custom System Integration Jim Enga President.
T24 Wireless Telemetry Advanced Intelligent Instrumentation.
Picarro Cavity Ring Down Spectrometry (CRDS) for High-Precision Continuous Monitoring of Atmospheric CO 2 and CH 4 Dave Lowry, Rebecca Fisher, Mathias.
The Technion Israeli Institute of Technology Intel Inc. A cooperation of:
NextPrevious CFlow+ Calibration Control Software Software upgrade for: Piston Calibrators / Provers Flow Transfer Standard - Gas & Liquid Bell Provers.
Call Center – What Really Makes Sense? Call Center – ce este cu adevarat important?
Distributed Control Systems Emad Ali Chemical Engineering Department King SAUD University.
Pocket Multi-channel Signal Analyzer IIntroduction Key Features Applications Key Specifications Hardware Connections.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
Ensuring of Traceability
Viking Pump Flow Manager - Phase 2 Senior Design May
Copyright by Silca S.p.A Unocode 399 EVO. Copyright by Silca S.p.A Unocode 399 Evo Unocode 399 Evo is quicker,quiter, easier to use and extremely.
Air conditioning: new IR emitter item WDS DIVISION Main advantage Permit to control air conditioning IR splitter from My Home touch screens Bus.
Gaseous Pollutants mini-course TAMS Center February 2009 Creating a Test Atmosphere.
1 9/10/2015 PanelDog DC Graphical LCD Meter Series.
8000 SERIES INTEGRATED THE INTEGRATED REFERENCE SOLUTION PRECISION DIGITAL MULTIMETERS.
Application Introduction APAC-5000 in AOI Equipment
Confidential. Smart Metering Solutions PRI has a complete portfolio of interoperable smart metering solutions to provide benefits to both the consumer.
Lab Bot 800 Dual Arm Fully Automated Liquid Handling Workstation.
Protocol Architectures. Simple Protocol Architecture Not an actual architecture, but a model for how they work Similar to “pseudocode,” used for teaching.
Training Learning to Work Efficiently and Accurately.
1 Dec. 8, 1997 LEADS Quality Assurance Summary Robert Brewer (512) Monitoring Operations Division Network QA Manager.
Physical Interoperability
DAQ Cards, or Instruments The purpose of this presentation is to familiarize new Lab View users to the different computer aided test recourses available.
WaveSurfer 3000 Oscilloscopes Public Release – July 1 st, 2014.
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
1 Advanced topics in OpenCIM 1.CIM: The need and the solution.CIM: The need and the solution. 2.Architecture overview.Architecture overview. 3.How Open.
1 Saxony-Anhalt EU Twinning RO 04/IB/EN/09 State Environmental Protection Agency Wolfgang GarcheWorkshop European Standards Requirements of.
HOME AUTOMATION HMI DEMO Michigan State University College of Engineering Team 3.
Ultima ® X Gas Monitor with HART Display Version.
INDRIYA TECHNOLOGIES PRIVATE LIMITED BELEIVING IN A SMARTER AND GREENER WORLD.
University of Bergen public domain software: Systems for seismic data-acquisition and processing T.Utheim 1, J.Havskov 1, Ø.Natvik 1, J.Å.Ojeda 1 and L.Ottemoeller.
FeaturesBenefits MagniVu™ acquisitionAvoid missing events completely in either timing or state acquisition mode with higher sampling resolution (up to.
Hardware Analyser vs Software Analyser
Defect Classes and the defect repository
Lighting Technologies YOUR PARTNER FOR LIGHT MENTOR/XT.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
Water. What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured application software.
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
Gas Mass Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees.
All-in-One Analog, AHD and TVI DVR
World Leaders in Combustion Management Solutions Module Gas Setup Introduction The Mk7 E.G.A Cell Status Further Information.
FlowLevel Client, server & elements monitoring and controlling system Message Include End Dial Start.
LabSpeed ™ Data Management software LabSpeed ™ Data Management Software.
ArtioSign and Receiver V5.2 Partner Webinar – 23 rd May 2016.
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
High Voltage Power Supply for RPC Suvendu Nath Bose, Satyajit Saha, Sudeb Bhattacharya, Saha Institute of Nuclear Physics, Kolkata,, Description Presently.
1 Chapter No. 9 Measurements and Detection of Radiation, Nicholas Tsolfanadis, 2010, McGRAW-HILL BOOK INTRODUCTION TO SPECTROSCOPY.
Written by : Oren Frenkel Intel Confidential ® C CD SDS.
LIAISON®: Instrument Overview
N4L Ltd. (UK) EMC IEC61000 COMPLIANT TEST SOLUTIONS
DELLSOFT Technologies Pvt. Ltd.
August 23, 2000 R.N. Dubois Dow Chemical
Instrumentation and control
Presentation transcript:

airQrate line of calibrators

Advantages of a dilution calibrator variation of concentrations out of one cylinder increased life time of calibration gas higher concentrations are more stable lower total gas consumption, long test sequences are possible ppm gas is cheaper than ppb gas ppm gas is better available

Advantages airQrate High precision multi gas (multi channel) calibrators with advanced capabilities Modular design: Ozone generator module with Photometer - Permeation system module - Dilution module - GPT module - Zero air supply

Unique features High quality calibration modules Direct communication with analyzer Storage of analyzer and calibrator data simultaneously Remote access Large touch screen display digital control of the MFC

Unique features Advanced programming capabilities Access to functions based on user level Build in solution for test sequences standardized (e.g. lack of fit) customized individual Sophisticated user interface Transfer or absolute mode

Preview Graphical User Interface

Two models Stationary calibrator 90-240V powered for up to 4 modules high precision mass flow controllers external zero air supply (1-2 bar) external calibration gas supply Mobile calibrator 12V/115V/230V powered for 1 module high precision mass flow meter and controller internal zero air supply internal and external calibration gas bottle and dilution internal gas pumps

airQrate mobile

Hand-on demonstration of the airQrate hardware

Distributor’s Inputs Inputs required: What is the calibration philosophy in your country QA procedures intervals calibration in station or in laboratory mobile calibration What are the requirements for multigas and multichannel laboratory calibrator mobile calibrator station calibrator

Availability Q2 2012: Hardware for all versions Q2 2012: Simple Software Q4 2012: Advanced Software designed user interface automatic sequences Q2 2013: more advanced SW automatic instrument communication automatic calibration reports

Thank you for your cooperation!