DayCor ® Technology Distribution. DayCor® Technology is used to detect Corona Particle Discharge and Arcing on electric grid components. It offers you:

Slides:



Advertisements
Similar presentations
An Introduction to On-line Partial Discharge Surveys
Advertisements

Condition Monitoring Of High Voltage Machines By The Analysis of
OVERHEAD LINE INSULATORS
Preventing Equipment Failures
April 27, 2012 Presented by: Andy Justice SWEDE Southwest Electric Distribution Exchange “The Evolution of Distribution Switchgear”
Presented by Malcolm Seltzer-Grant, HVPD Ltd
Fault location and Diagnosis
Ofil’s proprietary material Cannot be used without Ofil's explicit permission.
Competitors. Available PdM Technologies technology Characteristic Ultra VioletInfra RedUltra Sonic PD Visual  Pinpoint  Voltages  N/A Current.
Circuit Analysis and Troubleshooting A Six Step Procedure Created by Jimmie Fouts Houston County Career Academy for.
S8910U1000 Universal Electronic Ignition Modules Training Module
IGNITION SYSTEM SERVICE. TESTING AND REPAIR l Evaluate the symptoms –Narrow down possibilities l Pinpoint to a specific engine system –Compression –Fuel.
Definitions Dielectric—an insulating material placed between plates of a capacitor to increase capacitance. Dielectric constant—a dimensionless factor.
Electricity and Magnetism. Flashlight Why do the batteries have to be facing the same way in order for the flashlight to work?
Flanders Electric – Engineering Division Welcomes Youto an Overview of Reconditioned Switchgear.
©2008 The McGraw-Hill Companies, Inc. All rights reserved. Electronics Principles & Applications Seventh Edition Arc Fault Circuit Interrupters Charles.
Charging System Service
Ofil’s UVollé vs. CoroCAM 504
Iris Range : «Unconventional» conventional detectors.
1 Entergy Transmission Asset Preservation Department 2004 Objectives Entergy Transmission Planning Summit New Orleans, LA July 10, 2003.
Electrical Safety.
AFCI Reaction to Utility Events. CenterPoint Energy 35 KV Distribution Capacitor Bank – Switched through an automated system.
Electrical Safety INSTRUCTOR’S NOTES:
Enea Detectors Range.
Motor Testing (Motor Only)
- Corona Interpretation -
Arc Fault Circuit Interrupters. Residential fires caused by electricity occur more than 40,000 times each year in the U.S. alone. 40% are due to arcing.
Mrs. Brinston. a. Electrical malfunction is the second leading cause of fires in hospitals. b. Fortunately, electricity is also the most manageable of.
Frankfurt (Germany), 6-9 June 2011 EL-HADIDY – EG – S5 – 0690 Mohamed EL-HADIDY Dalal HELMI Egyptian Electricity Transmission Company Egypt EXAMPLES OF.
Electricity & Magnetism Chapter 19 and 20 Review for Test April 19, 2005.
Brookhaven Science Associates Accelerator Safety Workshop Lessons Learned at C-AD Accelerators E. Lessard August 7-9, 2007.
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
Conditioned-Based Maintenance
Secondary Ignition Will need crossfire demo 11/2001VHS Auto2.
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
UV-IR complimentary technologies. TOC “A picture is worth thousand words” No corona on IR picture Live End Corona Dead End Corona Corona spots using.
Utility Engineers, PC.  Generation  Transmission  Distribution.
23,000 students trained since 1980 Electrical maintenance, troubleshooting and safety courses Safety programs, procedures and arc flash studies Leadership.
52 RCACS Ground School Engines PO 407 EO 4 “Fuel Problems, Ignition, and Basic Electrical System”
Comparison of OFIL’s Corona Camera & Ultrasonic instruments.
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Modern Maintenance. Management
Capacitance The potential of a conductor and the charge on it are directly proportional to eachother.
Gary Rees UE Systems Europe Ultrasound for Preventative and Predictive maintenance.
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Bad case of Installation RAC-B-A07.
TECHNOLOGIES ESO 4 UNIT 1: ELECTRICITY AND ELECTRONICS ANALOGIC ELECTRONICS (PART 1)
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
MAYA .Y.PAI (1VA09EE024) PAVITHRA N. (1VA09EE031)
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Generator Condition Assessment through EMI Diagnostics Doble Power Services.
1 2 Introducing Acoustic Inspection Technology for Improving Network Reliability Goran Stojadinovic, Innovation and Technologies Manager Northpower,
Electrical Safety and Safe Work Practices
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Hipot Testing 101.
Doble Power Factor Bushing Test
Automotive Engines Theory and Servicing
LAV HV repair plans Matthew Moulson
Predictive-Based Maintenance Strategy
Clinical engineering Lecture (7).
How The Damaged Spark Plugs Affect Your Car
Circuit Breakers & Reclosers
PD Detection on Metal Enclosed Switchgear Panels
Why does any Car Catch Fire Suddenly.
Reasons Behind Electrical Issues in Cars
Overhead Conductors.
ELECTRICAL POWER-II Electrical engineering sixth semester
Bushings.
Incompatibility between MV Switchgear conforming TO the international standards and their use in DNO’s substations M. Arens – Y Tits – Belgium – Session.
Automotive Engines Theory and Servicing
Presentation transcript:

DayCor ® Technology Distribution

DayCor® Technology is used to detect Corona Particle Discharge and Arcing on electric grid components. It offers you: Early warnings of potential future failures. Pinpointing & Visualizing the corona effect. Decision ability to determines the health of your critical systems components Prioritize your particle discharge maintenance challenges Day time work DayCor® Technology saves you by avoiding costly unscheduled outages and failures DayCor ® Technology

E field e e + e e + e e e + -V e UV Ph Corona is a luminous partial discharge due air ionization. The DayCor® camera pinpoints the exact source’s location by visualizing the UV photons, coming out of it. Corona Effect Corona Source Free Electron, coming out from the source Natural Air molecule UV Photon

Combined mode Visible only display UV only mode Bi-Spectral Imaging Pinpointing the exact corona’s location

UV-IR complimentary technologies No corona on IR picture Corona spots using UV technology Live End Corona Dead End Corona

It Causes Degradation of polymer (NCI) insulators Ceramic Insulator Defects Physical damage to component. Cracks the cement of pins and metal caps of porcelain insulators. Wood Pole Fires Audio noise (AN) Corona is a concern because:

Degradation of polymer (NCI) insulators To get to that point is to waste your time & money Detect this failure in advance, to take the right action at the right time Corona Spot The outcome

Polymer Termination - 33KV

Physical damaged to component Left string- OutcomeRight string - Outcome Corona spots

Cracks on 11kv insulator

Cement problem indication -11kv

Wood Pole Fire The leakage currents can generate enough localized heat to ignite the wood at the point of contact between wood and metal surfaces and start a pole fire Insulators near or at the end of their service life can cause to pole fire 25kv

Audio noise - few reasons

It indicates: Possible Faults Sealing defects Shorted bells Gap discharge Loose hardware Contamination Corrosion or erosion Bad ground connections Corona is a concern because:

Possible Faults “This is not normally a serious issue but the broken wire was running down the side of the insulator, therefore reducing the insulating value from 6 sheds down to just one. The cause of there intermittent fault over 12 months has now been found in just 2 hours with the use of the corona camera" 22kV

Possible reasons Flash burn on the top shed from lightning Slight fracture on pin hole defect 33kv Possible Faults

Corona on the connection between the bushing and the capacitor. Losing Energy it to lose Money !

Possible Faults Leaking Current Dead End Corona

Sealing Defects IndicationThe problem Hollow core insulator. The core should be sealed at the bottom with a cork/rubber plug. The cork/rubber plug was cracked compromising the seal. Without the seal, moist air was introduced into the hollow core. The dielectric properties of the insulator were changed affecting the electric field. The condition would eventually lead to insulator failure. Ameren

play Sealing Defects

Shorted Bells

Gap discharge

Contamination agricultural pollution Salt contamination Agricultural pollution Polluted conductor

Corrosion - Erosion

Bad ground connections-22kv insulator

Switchgear Corona

AN, RI, TVI concern? Decision Chart Photons per Minute Can it be damaged by corona? Corona- where? Critical component? Material type Critical location? Corona intensity? No Yes High> <Medium<5000 Low<1000 Monitor for additional signs Schedule repair or replacement Repair or replace ASAP No Yes Repair or replace ASAP

Condition D Equipment fails to perform as expected Functionally failed High Counting Rate Equipment broken Outage Potential Failure C Medium Counting Rate Failure Process Failure starts here Low Counting Rate B Equipment at Normal conditions No Corona A

“…Attempting to measure and trend levels of observed ultrasonic activity and trying to relate them to the potential seriousness of surface partial discharge or end of life is not valid and could potentially lead to misleading conclusions…” “Testing Distribution Switchgear for Partial Discharge in the Laboratory and the Field”, by EA Technology, IEEE2008 Ultrasonic