E VERY L IFE H AS A P URPOSE… ULTIMA ® OPIR-5 Open Path Gas Detector E VERY L IFE H AS A P URPOSE…

Slides:



Advertisements
Similar presentations
Copyright© 2014 Austin Analytics Group, LLC. Stand Alone System High Temperature System Hazardous Area System Universal/Remote Display System Copyright©
Advertisements

SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Open-Path Gas Detection - Philosophy of Use or The Story of Clouds.
… for Combustible Gas Detection S4000C Intelligent Sensors..
Sensor Operating Theory
DP-IR Detecto-Pak Infrared
MAGNA3 – “built on a proven foundation”
ModCon® 75 Controller.
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
You Can Measure the Benefits… Solid Applied Technologies Sewer Level Monitoring.
Photoelectric Beam Detector NRTM Series. 2 1. Outline Dual beam detector NRTM series is a part of Red Barrier series. * 30m 60m 90m (Outdoor) range *Selectable.
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
Introducing… HVS4000 & HVS400 Toxic Gas Detectors from Halogen Valve Systems.
E VERY L IFE H AS A P URPOSE… Ultima ® MOS-5 Hydrogen Sulfide Intelligent Sensor E VERY L IFE H AS A P URPOSE… Introduction to a HART Enabled Detector.
THE LATEST DETECTION TOOLS FOR LEAK / ODOR RESPONSE, CARBON MONOXIDE AND CONFINED SPACE ENTRY Paul D. Wehnert Vice President – Sales & Marketing Heath.
Basic Air Monitoring Concepts And Use Of The Altair 4 Gas Meter
Protecting life, environment and property… 1 AutroFlame Detectors ID: AFLAME_X33_1_intro
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
MSA - ALTAIR 4X Gas Meter.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
Air Monitoring Presented By: Etech Environmental & Safety Solutions, Inc.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
You Can Measure the Benefits… Training Course Introduction to SmartScan.
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
Gas Sensor and Transmitter
ITX 4-Gas Detector Quick Reference Guide. Case:Type 304 Stainless Steel,.024" (.61mm) thick Dimensions:4.75" X 3.2" X 1.68" (121mm X 81mm X 43mm) Weight:18.5.
Ultima® X Series Gas Monitors
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Ron Helson HART Communication Foundation Austin, TX
2-Wire vs. 3-Wire Transmitters
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
GAS DETECTOR BY : SELAMAT SURIYADI.
GasGard® XL Monitor.
Features: ERTL TESTED  Displays distance to leak location in meters.  Indicates Cable break condition.  Modbus Output for BMS Monitoring.  Operates.
Smart transmitters.
High Sensitivity Smoke Detection
Nanotechnology Metal Oxide Semiconductor (NTMOS) H2S Gas Sensor
Solid Applied Technologies Gauger Compact, continuous, non-contact, loop- powered, ultrasonic level meter: Simple installation and configuration.
MAGNETO OPTICAL CURRENT TRANSFORMER Presented By: Shivankit Bansal Final Year Electrical Deptt.
TRANSMITTERS OLCT80. OLCT 80 d or id (with intrinsic safety sensor block) n II2GD n For combustible and toxic gases and oxygen n Fitted with pre-calibrated.
IN PARTNERSHIP WITH EVRIKA. IN PARTNERSHIP WITH EVRIKA.
E VERY L IFE H AS A P URPOSE… ULTIMA ® OPIR-5 Open Path Gas Detector E VERY L IFE H AS A P URPOSE…
What is TechStar … TechStar is a manufacturers representative dedicated to serving various Texas industries with process control instrumentation and analytics.
Made in United States of America ZVM Solo EMIT ZVM Solo the most complete monitoring solution on the market.
E VERY L IFE H AS A P URPOSE… FlameGard 5 MSIR Flame Detector.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Embedded Design Using ARM For Strong Room Security System
Virtual Analyser What is it Have you ever faced an analyser failure that requires a plant shut down to repair & wished that there.
Ultrasonic Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
The Theory of Near Light Scatter
Utility Engineers, PC.  Generation  Transmission  Distribution.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
New Product Developments World Leaders in Combustion Management Solutions C.E.M.S., MCERTs & E.P.A. Exhaust Gas Analysers C.E.M.S., MCERTs.
Small Telco Facility Protection Small, business-critical spaces where business interruption cannot be tolerated.
E VERY L IFE H AS A P URPOSE… Ultima ® XI Gas Monitor.
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
Introduction of Laser Evaluating Technology to Street Leak Surveys Ashraf Salha APA Group Gas Speak Colloquium September 2015.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
FIDEGAS Gas detection systems.
Gas Detection in Water Treatment
THE LINEAR BARRIER SAFE EYE The gas linear detection
HX-40/40AM 3.0m high mount outdoor detector HX-40: standard model
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Magnetostrictive Liquid Level Transmitter
Analog Room Command Module
Independent solar power PIR motion sensor
ANALYSERS & INSTRUMENTS DEPT. OPASTOP GP2001H
Total Solution for Flue Gas Analyzer Series
Presentation transcript:

E VERY L IFE H AS A P URPOSE… ULTIMA ® OPIR-5 Open Path Gas Detector E VERY L IFE H AS A P URPOSE…

Contents 1.Product Overview 2.False Alarm Immunity 3.Detector Placement 4.Installation 5.Split Concentration Range 6.Maintenance 7.Fault Conditions 8.HART 9.AMS Device Manager 10.Applications 11.Summary

ULTIMA OPIR-5 Detector  Description –Open path infrared hydrocarbon gas monitoring system  Expected Customer Benefits –Low power consumption –Dual analog outputs, ppm M and LEL M –Light and compact design –Resilient to solar radiation and fog –Long detection range –Available with HART and Modbus –Stainless steel construction –Integral display

Performance Specifications SpecificationsUltima OPIR-5 Response time (T90, s)< 5 Repeatability <  5% Linearity   5% FS or  10% Path length, max (m)150 Operating temperature range (  C) -55 to +65 Solar blindAll conditions Fog immunity 90% blockage,  10% acc. Combined weight, receiver and source (kg)11.13 (SS only) Supply power, nominal (W)23 Bidirectional communicationHART, Modbus Event logging and AMS Device ManagerAvailable

Solar Radiation Rejection  The ULTIMA OPIR-5 has superior immunity to solar radiation and other external IR radiation sources.

Performance Certifications  The ULTIMA OPIR-5 is the world’s first and only open path detector to meet agency performance requirements on both LEL m and ppm m scales

Detector Placement  Open path detectors should be installed based on several considerations: –Hazard conditions within the installation area covered –Ventilation rates, direction, and presence of recirculation and dead zones –Sensitivity to low (geometric) sunlight, fog, and reflections –Powerful sources of electromagnetic emissions like high powered electrical towers –Structures that may interfere with line of sight * Health and Safety Executive, Offshore Division,” Fire and Explosion Strategy, Issue 1,” 2004.

Installation  When installing an ULTIMA OPIR-5 detector, it is useful to consider the following: –Vibration can create issues –Solid foundation improves alignment integrity –The longer the line of sight path, the more solid the foundation required –Maintain a 6” to 12” radius around the line of site beam to avoid reflective interference from piping and supports –For outdoor installations, consider maximum snow levels –Good immunity to fog, steam, and rain but immunity degrades over longer distances –Avoid pedestrian traffic or overhead cranes –Keep beam low and down wind for heavy gases like propane and high for light gases like methane

Wiring 8 MOD1-Modbus 1-Modbus 2- MOD MOD1 + Modbus1+Modbus 2+ MOD A2Alarm NO/NC Fault NOFLT ACAlarm CFault CFLTC 20 4 A1Alarm NC/NO Fault NCFLT W2 LWarn NO/NC Warn NC/NO W2 P 22 2 WC LWarn C WC P 23 1 W1 LWarn NC/NO W1 P V COM 0 – 20 mA L COM 0 – 20 mA P COM RST COM Ultima OPIR-5 Receiver

Split Concentration Range  With the split range function, users can monitor the entire span of gas concentration with a single analog signal –Reduces wiring and commissioning costs LEL m 5,000 ppm-m (0.1 LELm) AO (mA) Methane Gas Concentration (ppm-m) Methane Gas Concentration (LEL m)

Alignment  Simple alignment process –Arm or base mounts available  Display –Menus activated by magnet –Enables easy alignment, setup & diagnostics

Maintenance  As with other combustible sensors, the ULTIMA OPIR-5 should be included in the plant maintenance schedule* –Gas check frequency depends on operating conditions (ex. dusty, corrosive, or damp environment) –Before repair or maintenance, the gas detector should be removed to a safe place outside the area being protected  If the hazard is still potentially present, it will be necessary to use a replacement gas detector in the area until the original detector is reinstated * BS EN 50073:1999 “Guide for the selection, installation, use and maintenance of apparatus for the detection and measurement of combustible gases or oxygen.”

Diagnostics  The ULTIMA OPIR-5 has self-diagnostics that inform users when certain types of device failures have occurred Fault Code Description F0Excessive negative drift or high IR F1Partial beam block or dirty lens F2Alignment F3Beam block F5Setup menu not exited F6Low supply voltage F7Heater error F8Failed zeroing F9Gas left (timeout) F10Reset short F11Unit overheating tF7Source internal error

HART  The ULTIMA OPIR-5 is available with HART for better efficiency with remote communication –Only the primary scale, LEL m or split range, connects through HART  Benefits of the HART-equipped ULTIMA OPIR-5: –Better diagnostics –Improved management of maintenance history and event logging –Flexible and accurate digital transmission –Effective cost control of devices in the field –Installation savings due to fewer wires

HART –Analog Signal for Faults Because HART requires a minimum current for operation, the ULTIMA OPIR-5’s fault conditions use 3.5 mA as minimum analog output FunctionCurrent Level (mA) Analog Output (Standard) ModbusHART (Default) HART-modified Analog Output Fault Test Gas Setup Mode Beam Block Startup Zero Reading4.04 Gas Concentration4 – 20 Over-range21.7 On HART-equipped unit, user must select the HART-modified AO in order use AO values below 3.5 mA

AMS Device Manager  Asset management and process improvement –Check compliance to calibration schedule –Coordinate calibrations so as to reduce labor cost –Aggregate calibration to a control room –Track gas level remotely –Read fault conditions from control room; before sending technician to the field

Ultima OPIR-5 Summary  Ultima OPIR-5 Open Path IR Detector –Detects ppm Meter & LEL Meter –Path Length up to 150 M –Wide Temperature range –Global Approvals –Integral Display - Easy alignment, diagnostics and maintenance