EKAS Flexible cords and plugs to 250 V

Slides:



Advertisements
Similar presentations
Introducing Electricity and Electrical Safety
Advertisements

Educatory Electro Services t/a EE Services
(Adapted from:D.T. Hall:Practical Marine Electrical Knowledge)
Electrical Installation
Today’s Meeting There are approximately 25 people killed by electricity per year in Australia (average for the last 7 years), 700 people are hospitalised.
EKAS Flexible cords and plugs to 1000 V UEE31307 Certificate III in Refrigeration and Air Conditioning Stage 2A Units: UEENEEPOO3B Chris Hungerford.
Inspection & Test Overview suite412.
30th Nov 2005Imnot50 Question 1 State the necessary action that should be taken by an inspector on discovering a damaged socket outlet with exposed live.
CIRCUIT ARRANGEMENT (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation Handbook,
EKAS Power cable and conductor terminations UEE31307 Certificate III in Refrigeration and Air Conditioning Stage 2A Units: UEENEEPOO1B Chris Hungerford.
EKAS Fault find- General Principles
Electrical Safety Testing of Electrical Installations and the verification of Electricians Test Tools Michael Bailey Transmille Ltd NCSLi 2014Transmille.
Hazard - Inadequate Wiring
Noadswood Science, 2012 Electrical Safety. Electricity Safety To be able identify safety features with electrical components Tuesday, August 11, 2015.
Lesson.5: Fuses and Safe Plugs
Underground Cables Chapter 11 V K MEHTA.
EKAS Disconnect & Reconnect UEE31307 Certificate III in Refrigeration and Air Conditioning Stage 2A Units: UEENEEPOO1B Chris Hungerford Sunday,
Health and Safety. The Health and Safety at Work Act 1974 An Act to make further provision for securing the health, safety and welfare of persons at work,
Professional competence in electrotechnics according to Act 50/1978 Coll. Workers instructed - §4 (without professional training or experience, only within.
Electricity at Work.
Unit 201: Health and safety in building services engineering
MINIMUM ACCEPTABLE LEVELS OF SAFETY & RELIABILITY
Electrical Installation 2
8.9 Household Electricity
Mains electricity Revise the following Direct and alternating current 3-pin plugs and electrical cable Safety – fuses and earth wire Period and frequency.
1 Cables A large portion of electrical signals are transmitted through solid electrical solid electrical conductors. A wire is a single conductor. A cable.
Electrical Safety.
IP The plug © Oxford University Press 2011 The plug.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
MAINS ELECTRICITY. Specification Electricity Mains electricity understand and identify the hazards of electricity including frayed cables, long cables,
Practical Electricity. Recap…  5 important formulae: Q = Charge (Coulomb) I = Current (Ampere) t = time (second) V = Voltage or potential.
1a.  Exposed part  Live or energized part  De-energized part 1a.
NGfL CYMRU GCaD ELECTRICAL WORKS DISCLAIMER Neither WJEC or NGfL accepts any responsibility whatsoever for any injury, however caused,
Physics Module 2 Mains Electricity. What do you need to know Voltage and frequency of UK mains electricity Wiring of a 3-pin plug Properties of materials.
The 13 Amp PLUG Fuse Insulating Casing Live Wire Neutral Cable grip Flexible Copper conductors Earth.
PORTABLE & TRANSPORTABLE ELECTRICAL EQUIPMENT. Legal Requirement and References Abu Dhabi RSB Electrical Regulations - makes reference to the need to.
UNDERGROUND CABLE.
Testing of Low Voltage Installations
Cables, Plugs and Fuses Additional Physics. Learning Outcomes Most students should be able to: –Describe the design and function of a three-pin mains.
PHYSICS – Dangers of electricity. LEARNING OBJECTIVES Core State the hazards of: – damaged insulation – overheating of cables – damp conditions State.
DOMESTIC ELECTRICAL CIRCUITS National Diploma Mechanical and Electrical Services Construction.
Starting Residential Wiring.  The most important element in wiring. Safety is proper grounding.  Grounding is the connection of all parts of a wiring.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
What is wrong with these plugs? L N E L N E L N E.
Electrical symbols Plug problems Earthing Circuit breakers Electrical safety a.c. theory.
Electrical Safety.
4.0 DOMESTIC ELECTRICITY Domestic electricity is that electricity which is supplied to homes under specific conditions of current and voltage. Voltage,
Electric Wiring & Illumination
“Success in Safety”.
AS3000:2017 Changes Alterations Additions and Repairs
Receptacle Classifications
Agricultural Systems Technology II
Hazardous Areas & Hazards of Electricity
Practical electricity
Personal Protective Equipment
Electrical Safety in the Home
Engineering Project Cable Management.
Electrical Safety.
Mains Plug Wiring: Brown lead Live Blue Lead Neutral
Domestic Electricity AIM: To understand the use of domestic electricity and safety features such as fuses, circuit breakers and the earth circuit
MAINS ELECTRICITY.
Electrical components and systems
Electrical components and systems
PHYSICS – Dangers of electricity. LEARNING OBJECTIVES Core State the hazards of: – damaged insulation – overheating of cables – damp conditions State.
Level 2 Electrical and Electronic 3
Presentation transcript:

EKAS 2.19.30 Flexible cords and plugs to 250 V UEE31307 Certificate III in Refrigeration and Air Conditioning Stage 2A Units: UEENEEPOO2B Chris Hungerford Wednesday, April 19, 2017

Flexible cords Ordinary Duty Light Duty Heavy Duty 2.19.30.A

How is a flexible cord different from other cables? The conductors in a flexible cord are made up of many more strands of finer wire than an ordinary cable (0.3mm). This allows the cord to flex without breaking the conductors. The maximum cross-sectional area (CSA) of a conductor in a flexible cord is 4mm2. Finally, the maximum number of insulated conductors (or cores) in a single cord is five. 2.19.30.A

Maximum length of flexible cords

Maximum current rating of flexible cords NOTES: 1 Where a flexible cord is wound on a drum, multiply current-carrying capacity by the appropriate factor, as follows: Number of layers: 1 2 3 4 Derating factor: 0.76 0.58 0.47 0.40 2 Flexible cords having tinsel conductors with a nominal cross-sectional area of 0.5 mm2 have a current carrying capacity of 0.5 A. 3 The current-carrying capacity is based on a cable maximum conductor operating temperature of 60°C in order to limit the surface temperatures for the expected use of such cables. Where flexible cords are used as fixed wiring, the current ratings are given in Tables 4 to 15 and 17. (Refer to Clause 3.3.2). 4 To determine the three-phase voltage drop, refer to the appropriate value in Table 46, Table 47 or Table 48. To determine the single-phase voltage drop, multiply the three-phase value by 1.155.

Electrical cables Conductor Strand 3 Core & Earth Circular An electrical cable is identified by its: Conductor material e.g. copper or aluminium Conductor size e.g. 1.5mm² CSA Insulation material e.g. rubber, glass, PVC Number of cable cores e.g. 7/0.50 – i.e. 7 strands of 0.50mm circular diameter Voltage grading e.g. 0.6 / 1 KV; 250V / 440V Sheathing Protection Conductor Strand 2.19.30.A Steel Wire Armoured SWA

Ratings of cables Voltage rating, all cables have a maximum operating voltage. This is directly related to the type and thickness of the insulation material. Temperature rating, table 3.2 AS 3000: 2007. Cables are NOT rated in Current Carrying Capacity. A cable's current carrying capacity is determined buy how it is installed as per AS/NZS 3008.1.1 (Australian). 2.19.30.A

Selecting a cord Operating conditions; Current carrying capacity of the cable. Operating conditions; temperature voltage installation factors such as in direct sunlight, mechanical protection, & thermal installation. Number of conductors. 2.19.30.A

Plugs and sockets There are many types of plug tops, the most common being the 10A three-pin plug. 2.19.30.A

2.19.30.A

2.19.30.A

2.19.30.A

International Protection Numbers

AS/NZS-3000:2007 SAA Wiring Rules 3.7.2.8 Flexible cords Joints shall not be made in flexible cords. Exceptions: Joint in flexible cords may be made - Where used as installation wiring By means of suitable cable couplers Any flexible cord shall be installed so that undue stress on its connections due to a pull on the cord is alleviated by a pillar, post, grip, tortuous path, or other effective means. Knotting of the flexible cord shall not be acceptable for this purpose. 2.19.30.C

2.19.30.C

Accessories All accessories must be suitable and as per Australian standards . All accessories must be suitable for the application. Wide variety of accessories can be accessed via suppliers catalogues. 2.19.30.C

A=Excellent B=Good C=Fair D=Poor

AS/NZS-3000:2007, SAA Wiring Rules 3.7 ELECTRICAL CONNECTIONS 3.7.1 General Connections between conductors and between conductors and other electrical equipment shall provide electrical continuity and adequate mechanical strength. Solder less lugs Crimps Compression terminals Soldered connections 2.19.30.C

AS/NZS-3000:2007 SAA Wiring Rules 3.7.2.2 Preparation for connection The insulation on a conductor shall not be removed any further than is necessary to make the connection. For connections between insulated conductors the connection shall be insulated to provide a degree of insulation not inferior to that of the conductors. Any damaged insulation shall be reinstated. 2.19.30.C

Insulation of conductors Masking tape packing tape sticky tape silicon mastic Yes Electrical insulation tape Epoxy kits Heat shrink 2.19.30.C

Conductor colouring AS/NZS 3000 Table 3.4 Function Colour Earth/bonding Green/yellow Neutral Black Light blue Active Red Brown, dark Blue, Grey, White, any colour other than green/yellow, green, black, yellow or light blue 2.19.30.C

Terminations and connections Connections must not be soft soldered before compression terminations. Must be seated correctly. Free of dirt and oxides. Use a suitable lug or connector. Insulated to the equivalent of the original insulation. Earth connection must be painted if exposed to weather 2.19.30.C

AS/NZS-3000:2007 SAA Wiring Rules 3.7.2.6 Mechanical stress All cables and conductors shall be installed so that there is no undue mechanical stress on any connection. 3.7.2.3.1 Loosening of connections Connections shall be made so that no loosening is likely because of vibration, alteration of materials or temperature variations to which the connections are likely to be subjected in normal service. 2.19.30.C

The eight visual checks recommended are: Check for obvious damage or defects. Check that flexible cords are properly anchored Check for any damage to flexible cords. Check that maximum load warning labels are intact. Check that any controls such as switches are in working order. Check that covers and guards are properly secured as intended. Check that any safety devices are in good working order. Check that vents or exhausts are unobstructed. 2.19.30.D

Earth Continuity Test Any Class I equipment with exposed metal parts must have its protective earth checked to ensure it is continuous from the earth pin of the plug to any exposed metal. The resistance must not be greater than 1Ω. Instrument Low reading ohmmeter. 2.19.30.D

Earth Continuity Earth Pin To Earth Socket 1 What is the value of earth continuity? Instrument Low reading ohmmeter. 2.19.30.D

Earth Continuity “Class 1” 1 Earth Pin To Exposed Metal 1 What is the value of earth continuity? Instrument Low reading ohmmeter. 2.19.30.D

Insulation Resistance Test: All equipment must be tested to ensure the integrity of the insulation, no electricity must be allowed to escape from the conductors or the appliance. 2.19.30.D

Insulation Resistance “Class 1” Switch ON Active & Neutral To Exposed Metal 1M 1 Q What is the value of insulation resistance? Megohmmeter 2.19.30.D

Insulation Resistance “Class 2” Switch ON Active & Neutral To Exposed Metal 1M 1M 1 Q What is the value of insulation resistance? Megohmmeter 2.19.30.D

Insulation Resistance “extension lead” 1M Active & Neutral To Earth Pin 1M 1 Q What is the value of insulation resistance? Megohmmeter 2.19.30.D

Polarity Active Pin To Active Socket 1 low What is the value of continuity? Instrument Low reading ohmmeter. 2.19.30.D

Polarity 1M Neutral Pin To Neutral Socket low 1 What is the value of continuity? 2.19.30.D Instrument Low reading ohmmeter.

2.19.30.D Is this correct? V1 240v V2 240v V3 0v Is this correct? What should the voltage be? Is this correct? V2=? 240v V1 240v V2 240v V3 0v V3=? V1=? 240v 0v Is this correct? 0v Reversed polarity A-N 0v 0v No Supply Is this correct? Is this correct? 0v 240v 240v 0v 240v 240v Correct Reversed polarity A-E

Minimum records that should be completed and maintained A record of the inspection and test results. A record of faulty electrical equipment (has it been repaired or destroyed). Date of inspection Appliance Visual inspection Earth continuity W Insulation resistance MW Polaritya = Correct RCD test current 30 MA trip time Milliseconds 0h 180h Test butt 2/7/09 Refrigerator ( LG model R100020 Serial 1004039832) O.K 0.3 75M N/A Safetypac (Clipsal mod 56B, serial 9987987) o.K. 0.8 187M a 22 18 2.19.30.D

2.19.30.D

Energising supply Only after the visual inspections and safety testing as per AS/NZS 3000:2007 has proven that the circuit is fit for purpose are you to energise the circuit. Remove only your Danger tag. If another worker has their danger tag on the isolated point then you can not energise. If clear: Energise the circuit. Test for the correct and safe operation of the circuit, i.e. rotation, system performance, current draw, voltage, etc. Prepare all your safety and performance documentation. 2.19.30.D