HASCO Hotrunner controllers Perfectly suiting your control task  A wide variety of hotrunner controllers ranging from the competitively priced single.

Slides:



Advertisements
Similar presentations
To develop a interactive electronics control system and fabrication support to design a next generation Co2 incubator. Existing product with heater, solenoid,
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
Welcome to the Introduction of SPICE Flex
Engineering Redefined
Multi-Loop PID Controllers All Watlow® multi-loop time/temperature controllers offer auto-tuning which automatically sets PID control parameter for optimum.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
“NEFTOGAZ TECH” LLC President of the Group of companies “ND” Leonid Pashkevych, 2014 Specialized presentation about the System of complex automation of.
C-Bus Now and in the Future
4 key operations UP/ DOWN 、 Esc and Enter Only 3 keys are needed for the rator to adjust all the parameters Simple Esc key Chips Programmable Intelsteer.
Security Systems BU Communication Systems Slide 1 Plena Voice Alarm System Commercial Presentation.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
COMPUTER APPLICATIONS Mr. Toscano Computer Concepts Lesson Objectives Students are introduced to the differences between computer software and computer.
Unit 1: Getting Started. What is a network?? A group of two or more computers that are linked together. Network Interface Card (NIC), basic network software.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Efficient flexibility in room management with SAUTER EY-modulo.
User interface design Designing effective interfaces for software systems Objectives To suggest some general design principles for user interface design.
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
Phaseo Power Supplies ACE Expert Training Presentation 2009.
Cross Strait Quad-Regional Radio Science and Wireless Technology Conference, Vol. 2, p.p. 980 – 984, July 2011 Cross Strait Quad-Regional Radio Science.
Monitoring systems COMET types MS55 & MS6 MS55/MS6 Configuration.
PLC: Programmable Logical Controller
1 TOUCH SCREEN PRESENTED BY NAINA Overview Introduction How does touch screen monitor know where you are touching? Basic working Principle.
G650 Generator Protection & Control System
Hardware -Computer Organization. Hardware & Software A computer system consists of A computer system consists of –Hardware: anything you can touch, smell,
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
FG Wilson Access 4000 Control Panel
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
RO400FC Forced convection hot air reflow oven. In a flexible production, what do you need for soldering of  Complex PCB’s  Soldering of fine pitch on.
What is Sure BDCs? BDC stands for Batch Data Communication and is also known as Batch Input. It is a technique for mass input of data into SAP by simulating.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
SFT 2841 IN CONNECTED MODE Prepare setting files.
High Sensitivity Smoke Detection
11.10 Human Computer Interface www. ICT-Teacher.com.
HP900 (ESP Protocol) Analogue Addressable Control Panels
Improve Control Room Monitoring…
Scope To develop a interactive electronics control system and fabrication support to design a next Constant Climate Chambers. Existing product with heater,
Toda una gama de proyectos domóticos listos para instalar Home Automation proyects ready to install.
All rights reserved, property and © CAD Computer GmbH & Co.KG 2009 Cover page.
INTER REGIONAL PROCESSOR. DESIGN PHILOSOPHY n Based on industry standard pc hardware. n Industrial specification IBM compatible computer running Fylde.
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
All rights reserved, property and © CAD Computer GmbH & Co.KG 2009 Cover page.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
Scope To convert panel meter based B lood Bank Refrigerator to a dedicated and customized control unit with enhanced feature and automation. Existing product.
Computer Networks. Data & Communication When we communicate we share information  Local Communication, if Face to Face  Remote, if through Telephone.
Capabilities of Software. Object Linking & Embedding (OLE) OLE allows information to be shared between different programs For example, a spreadsheet created.
Scope To convert panel meter based BOD incubator to a dedicated and customized control unit with enhanced feature and automation. Existing product with.
PTS 2.3 C Portable Test System Page 1 March 2009.
C OMPUTING E SSENTIALS Timothy J. O’Leary Linda I. O’Leary Presentations by: Fred Bounds.
CEA DSM Irfu SIS LDISC 18/04/2012 Paul Lotrus 1 Control Command Overview GBAR Collaboration Meeting Paul Lotrus CEA/DSM/Irfu/SIS.
August Video Management Software ViconNet Enterprise Video Management Software Hybrid DVR Kollector Strike Kollector Force Plug & Play NVR HDExpress.
IT323 - Software Engineering 2 1 Tutorial 3.  Suggest ways in which the user interface to an e-commerce system such as an online stores might be adapted.
Systems and User Interface Software. Types of Operating System  Single User  Multi User  Multi-tasking  Batch Processing  Interactive  Real Time.
An operating system (OS) is a collection of system programs that together control the operation of a computer system.
The Quality Control Company Quanti TM product series “Simplicity is the ultimate sophistication” - Leonardo da Vinci.
DOCUMENTATION REF: Essentials of IT (Hamilton et al) Chapter 1.
Overview Presentation MKT-DSRV-P- 001E. Product Overview Network based video transmission product with on-board digital recording Allows analogue fixed/PTZ.
Programmable Logic Devices
Operating Systems What an Operating System is.
Text آشنایی بیشتر با کنترلر هوشمند زیمنس
How SCADA Systems Work?.
Some Simple Definitions for Testing
Programmable Logic Controllers (PLCs) An Overview.
Cover page.
TEMPERATURE Logging Systems
Application Stories.
Rapid Automation Design
Presentation transcript:

HASCO Hotrunner controllers Perfectly suiting your control task  A wide variety of hotrunner controllers ranging from the competitively priced single zone controller for single shot nozzles to high tech multi zone controllers with PID² and touch screen displays  Within this range it is always possible to find the best balance between a multitude of control parameters and ease of use in the production environment at a competitive price per control zone

HASCO Hotrunner controllers Perfectly suiting your control task, Z125/...  Single zone controller Z125/2/..., developed to control standard heating elements, heater tubes and single nozzles  Very simple operation. Adjustment of the set value via potentiometer  Fix programmed soft start function  50% temperature down function  Indicates T/C defects and wrong wiring  Power output 10A/2300W  Excess temperature alarm  Actual and set temperature at a glance

HASCO Hotrunner controllers Perfectly suiting your control task, Z126/...  Multi zone controller Z126/... with modular design from 1 to 24 zones  Simple adjustment of set values via decade switch  Excellent price- performance ratio  Clear error messages in digital display  Automatically switching to actuator-control in case of T/C defect  Alarm interface with potential-free connection to moulding machine  Self optimized control performance

HASCO Hotrunner controllers Perfectly suiting your control task, Z126/...  Programmable soft start function and limits for temperature alarm  Programmable temperature-down function  3600 W power per control circuit  Standard interfaces for communication with moulding machine, e.g automatic temperature-down in case of production interruption  Additional functions like “boost” (short time temperature increase to opening gates or colour change)  Temperature fall activation at production stop by a single key

HASCO Hotrunner controllers Perfectly suiting your control task, Z122/...  For demanding control tasks with with quick control processes and hotrunner nozzles with small inertia  PID Control action  Designed in modular plug-in technology  Two digital displays for set temperature and controlling actual temperature  Easy-to-operate adjustment  Individual optimization of almost each control situation  Soft start, temperature fall, alarm- settings free adjustable

HASCO Hotrunner controllers Perfectly suiting your control task, Z122/...  Short-term temperature increase setings (boost-function) programmable  Memory settings can be changed  Z122/... comprises 10 memory locations per control unit to save the optimized data sets  3600 W per control circuit  Optional RS 485-Interface for data exchange with a PC and the moulding machine

HASCO Hotrunner controllers Perfectly suiting your control task, Z1293/...  The Z1293/... offers the best combination between elaborate functionality and advantegous price per control circuit  Controlling of multicavity applications with control moduls of 6 ciruits  Unit sizes with 6, 12, 18, 24, 30, and 36 Control circuits  Power output per circuit 3600 W  Soft start, temperature fall, alarm- settings, boost function, alarm diagnosis and parameters of alarm interfaces individually adjustable  Sensor monitoring and interconnected heat-up  Performance diaplay in Ampere and %

HASCO Hotrunner controllers Perfectly suiting your control task, Z1230/...  Excellent price/performance ratio  Extensive diagnostic and protocol functions provide advantages testing and running in complex hotrunner systems up to 144 control circuits  Highest level of control accuracy for consistent product quality  Long-term storage of the data for optimum process monitoring /process protocols  Rapid targeted fault diagnosis by clear listing and documentation oferror messages and faulty

HASCO Hotrunner controllers Perfectly suiting your control task, Z1230/...  Comfortable PC operation with touch-sreen provides optimum comfort with optimum clarity and user guidance  Clear presentation and monitoring of all process factors  Drawings and photos of the hotrunner can be displayed for intuitive operating

HASCO Hotrunner controllers Perfectly suiting your control task, Z123/...  The economic panel with membrane keyboard in sturdy layout for practical applications. As an optional extra, software is available which can be installed on any PC or laptop running the WINDOWS operating system  This option offers the user all the range of application of the touch-screen unit

HASCO Hotrunner controllers Perfectly suiting your control task, Z1230/...  The control unit without operator unit, together with the software which can be installed on any PC or laptop running the WINDOWS operating system  The control unit can be easily and rapidly connected to the PC or laptop for setting up or for process monitoring. It is possible to use one PC to operate and monitor several control units

HASCO Hotrunner controllers Perfectly suiting your control task, Z12931/...  Data readout unit for Z1293/... Control unit  Can be integrated in PPS systems  Optimum process monitoring and documentation  Read out ASCII files can be processed in Windows appications or databases  Error messages in clear text  Ethernet interface for network connection  Time intervals of the temperature protocols freely selectable  Cost-effective facility, Z12931/... upgrade controller with process data capture

HASCO Hotrunner controllers  Our application engineers are welcome to advise you in selecting the optimal choice for your control task  With consistent use of HASCO hotrunner, HASCO wirings and HASCO control units warrenty times can be exeeded far beyond the usual terms  An intesnive communication between customer and appplication engineer, starting from the project planning ensures failure-free operation and maximum productivity Perfectly suiting your control task